Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

14 SOLAR ENERGY↗

Resilience and economics of microgrids with PV, battery storage, and networked diesel generators

Current designs and assessments of microgrids have ignored component reliability, leading to significant errors in predicting a microgrid’s performance while islanded. Existing life cycle cost studies on hybrid microgrids—which combine photovoltaics (PV), battery storage and networked emergency diesel generators—also have not identified all the potential economic opportunities. Reducing the number of emergency diesel generators through reliance on PV and battery, retail bill savings, and demand response and wholesale market revenue streams are all important. This paper provides a new statistical methodology that calculates the impact of distributed energy reliability and variability on a microgrid’s performance and a novel use of the optimization platform REopt to explore multiple cost savings and revenue streams. We examine the impacts for microgrids in California, Maryland, and New Mexico and show that a hybrid microgrid is a more resilient and cost-effective solution than a diesel-only system. Under realistic conditions, a hybrid microgrid can provide higher system reliability when islanded and have a lower life cycle cost under multiple market conditions than a traditional diesel generator-based system. The improved performance of the hybrid system is resilient to conditions experienced over the last 20 years in solar irradiance and sees little degradation in performance immediately after a hurricane. The cost savings to provide this more resilient backup power system as compared to a diesel-only microgrid are significant. The net present cost for a hybrid microgrid is 19% lower in New Mexico and 35% lower in Maryland than a diesel-only microgrid. In California, the net present cost of the hybrid microgrid is negative because, unlike a diesel-only microgrid, a hybrid microgrid has lower life cycle costs than the power costs without a microgrid.

25 ENERGY STORAGE↗

Technology and Climate Trends in PV Module Degradation: Preprint

To sustain the commercial success of photovoltaic (PV) technology it is vital to know how power output decreases with time. Unfortunately, it can take years to accurately measure the long-term degradation of new products, but past experience on older products can provide a basis for prediction of degradation rates of new products. An extensive search resulted in more than 2000 reported degradation rates with more than 1100 reported rates that include some or all IV parameters. In this paper we discuss how the details of the degradation data give clues about the degradation mechanisms and how they depend on technology and climate zones as well as how they affect current and voltage differently. The largest contributor to maximum power decline for crystalline Si technologies is short circuit current (or maximum current) degradation and to a lesser degree loss in fill factor. Thin-film technologies are characterized by a much higher contribution from fill factor particularly for humid climates. Crystalline Si technologies in hot & humid climates also display a higher probability to show a mixture of losses (not just short circuit current losses) compared to other climates. The distribution for the module I-V parameters (electrical mismatch) was found to change with field exposure. The distributions not only widened but also developed a tail at the lower end, skewing the distribution.

14 SOLAR ENERGY↗

Optimal Load Ensemble Control in Chance-Constrained Optimal Power Flow

Distribution system operators (DSOs) world-wide foresee a rapid roll-out of distributed energy resources. From the system perspective, their reliable and cost effective integration requires accounting for their physical properties in operating tools used by the DSO. This work describes an decomposable approach to leverage the dispatch flexibility of thermostatically controlled loads (TCLs) for operating distribution systems with a high penetration level of photovoltaic resources. Each TCL ensemble is modeled using the Markov Decision Process (MDP). The MDP model is then integrated with a chance constrained optimal power flow that accounts for the uncertainty of PV resources. Since the integrated optimization model cannot be solved efficiently by existing dynamic programming methods or off-the-shelf solvers, this paper proposes an iterative Spatio-Temporal Dual Decomposition algorithm (ST-D2). Finally, we demonstrate the merits of the proposed integrated optimization and ST-D2 algorithm on the IEEE 33-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Development of an AC Module System: Final Technical Report

The GreenRay Inc. program focused on simplifying solar electricity and making it affordable and accessible to the mainstream population. This was accomplished by integrating a solar module, micro-inverter, mounting and monitoring into a reliable, 'plug and play' AC system for residential rooftops, offering the following advantages: (1) Reduced Cost: Reduction in installation labor with fewer components, faster mounting, faster wiring. (2) Maximized Energy Production: Each AC Module operates at its maximum, reducing overall losses from shading, mismatch, or module downtime. (3) Increased Safety. Electrical and fire safety experts agree that AC Modules have significant benefits, with no energized wiring or live connections during installation, maintenance or emergency conditions. (4) Simplified PV for a Broader Group of Installers. Dramatic simplification of design and installation of a solar power system, enabling faster and more efficient delivery of the product into the market through well-established, mainstream channels. This makes solar more accessible to the public. (5) Broadened the Rooftop Market: AC Modules enable solar for many homes that have shading, split roofs, or obstructions. In addition, due to the smaller building block size of 200W vs. 1000W, homeowners with budget limitations can start small and add to their systems over time. Through this DOE program GreenRay developed the all-in-one AC Module system with an integrated PV Module and microinverter, custom residential mounting and performance monitoring. Development efforts took the product from its initial concept, through prototypes, to a commercial product sold and deployed in the residential market. This pilot deployment has demonstrated the technical effectiveness of the AC Module system in meeting the needs and solving the problems of the residential market. While more expensive than the traditional central inverter systems at the pilot scale, the economics of AC Modules become more and more favorable as the product matures and is made in high volumes. GreenRay's early customers have been highly enthusiastic about the AC Module system benefits.

14 SOLAR ENERGY↗

Electrolytic Renewable Fuel Production Optimal Operation Investigation - H2@Scale: Cooperative Research and Development Final Report, CRADA Number CRD-19-00818

This work explored the optimal design and operation of electrolytic hydrogen production from renewable power. While there are many financial incentives for renewable hydrogen, this work investigated the effects of Low Carbon Fuel Standards (LCFS) on the hydrogen breakeven cost. To this end, this project developed optimized operational strategies for electrolytic hydrogen facilities in the California. Four specific model projects were used as the basis for the analysis. Three model projects will be located in California and one in Texas or the Midwest to be determined during the project. All projects include interconnection to the natural gas grid as a method of transport for the product fuel and the hydrogen cases will also consider alternative modes of transport. The operational optimization will maximize project return through fuel production and grid services based on future scenarios for the value of each. The effort will rely on modeling tools developed by NREL and the UCI for grid modeling as well as the integrated resource planning tool (IRP), RESOLVE, which is the official IRP tool used by the California Public Utility Commission (CPUC). The development of this project can help to inform future hydrogen deployment, policy and regulation makers, research and development decisions, and private and public investment.

08 HYDROGEN↗

Integration of DER Adoption Forecasting into Distribution Planning: Cooperative Research and Development Final Report, CRADA Number CRD-11-00430 (Project H)

The objective of this project is to improve distributed energy resources (DER) technology, time, and locational impact analysis by incorporating customer adoption intentions and preferences into distribution planning and operations. The National Renewable Energy Laboratory (NREL) shall collaborate with EPRI staff to contribute to the development of methodology, literature review, analysis, and write-up for two sections of a report "Identification and Overview of Methods for Mapping DER Adoption Forecasts” and “Comparative Analysis of Methods for Mapping DER Adoption Forecasts."

14 SOLAR ENERGY↗

Modular, Multifunction, Multiport and Medium Voltage Utility Scale SiC PV Inverter (Final Report)

This project is to develop and demonstrate a Modular, Multi-function, Multiport and Medium Voltage utility scale SiC solar inverter (M4 Inverter). The M4 Inverter is a next generation utility scale PV + storage inverter that can substantially reduce the levelized cost of energy (LCOE) while providing grid friendly ancillary services. Conventional utility scale solar inverters includes three parts, a megawatt rated solar inverter, a low frequency transformer (LFT) and a medium voltage switch gear. The proposed M4 Inverter directly converts the DC output of solar panels to medium voltage AC, eliminating the bulky and costly LFT. The M4 Inverter also has a DC port to interface with an additional energy storage device. This plus its bidirectional power flow capability, allows multiple functions in addition to PV maximum power tracking be achieved. These additional functionalities include but not limited to reactive power support, peak shaving, fast frequency regulation and synthetic inertia. Predicted LCOE reductions with these added functionalities, improved efficiency and longer lifetime time are more than 30% compared with the 2017 utility scale solar LCOE. A 1MVA SiC M4 Inverter was developed and tested at high power level. The project has also advanced the state of the art in controller hardware in the loop simulation capability. Power electronic innovations introduced in the M4 Inverter includes 1700V SiC MOSFET application in 1500V PV system, soft switching three-port power converters and modular converter architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building America Case Study: Photovoltaic Systems with Module-Level Power Electronics

Direct current (DC) power optimizers and microinverters (together known as module-level power electronics, or MLPE) are one of the fastest growing market segments in the solar industry. According to GTM Research in The Global PV Inverter Landscape 2015, over 55% of all residential photovoltaic (PV) installations in the United States used some form of MLPE in 2014.

14 SOLAR ENERGY↗

MN Solar Pathways: Enhanced Hosting Capacity Analysis

As part of the Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, Smarter Grid Solutions (SGS) completed an evaluation of emerging technologies as non-wires alternatives to integrate solar PV. SGS evaluated stand-alone smart inverters, centrally coordinated smart inverters, thermal load shifting, energy storage, and a combined technology scenario to compare and contrast the benefits at four distribution feeders. The analysis showed that there is not a “one size fits all” answer to increasing hosting capacity beyond a feeder’s static limit, since each feeder faces different constraints.

14 SOLAR ENERGY↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Technical Sessions

This presentation provides summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward a technical audience. A companion policy presentation provides higher-level summaries of the same material.

distributed energy resource↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Policy Sessions

This presentation provides high-level summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward policy decision makers. A companion technical presentation provides more in-depth summaries of the same material.

distributed energy resource↗