Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Measurements at peak operational beam current in the SNS beam test facility

Work at the SNS beam test facility has focused on high dimensional and high dynamic range measurements of the medium energy (2.5 Mev) beam distribution. This is motivated by the need to understand and predict beam losses down to one-part-per-million. The initial demonstration of full-and-direct 6D phase space measurement was done at a current of 40 mA transported through the RFQ. Since that demonstration, more detailed studies have been performed at lower transported currents (in the range 30 mA and below). This is due to a hardware change - recent runs utilize the original SNS RFQ, which after a decade of service in the SNS achieves transmission significantly below design (50-60%, vs >80%). A short run in 2023 with a newly-commissioned RFQ enables maximum transmission. Preliminary results from beam distribution measurements during this run are discussed.

Ruisard, Kiersten↗

Recent progress in laser wire-based H- beam diagnostics at the SNS linac

Laser wire has been used for nonintrusive profile and emittance measurements of operational hydrogen ion (H-) beam at the SNS linac. In this talk, we will describe the following recent developments in the laser wire system. 1) An upgraded light source and laser transport line which enables novel measurement capabilities including longitudinal profile measurement and high-energy proton beam extraction over potentially an entire macropulse. 2) A dual-detector emittance measurement scheme that boosted the dynamic range by an order of magnitude. 3) Design and implementation laser-wire-based nonintrusive longitudinal phase space measurement system.

Liu, Yun↗

Fermilab Switchyard Resonant Beam Position Monitor Electronics Upgrade Results

The readout electronics for the resonant beam position monitors (BPMs) in the Fermilab Switchyard (SY) have been upgraded, utilizing a low noise amplifier transition board and Fermilab designed digitizer boards. The stripline BPMs are estimated to have an average signal output of between -110 dBm and -80 dBm, with an esti-mated peak output of -70 dBm. The external resonant circuit is tuned to the SY machine frequency of 53.10348 MHz. Both the digitizer and transition boards have vari-able gain in order to accommodate the large dynamic range and irregularity of the resonant extraction spill. These BPMs will aid in auto-tuning of the SY beamline as well as enabling operators to monitor beam position through the spill.

43 PARTICLE ACCELERATORS↗

An Exploratory Energy Analysis of Electrochromic Windows in Small and Medium Office Buildings - Simulated Results Using EnergyPlus

The Department of Energy’s (DOE) Building Technologies Program (BTP) has had an active research program in supporting the development of electrochromic (EC) windows. Electrochromic glazings used in these windows have the capability of varying the transmittance of light and heat in response to an applied voltage. This dynamic property allows these windows to reduce lighting, cooling, and heating energy in buildings where they are employed. The exploratory analysis described in this report examined three different variants of EC glazings, characterized by the amount of visible light and solar heat gain (as measured by the solar heat gain coefficients [SHGC] in their “clear” or transparent states). For these EC glazings, the dynamic range of the SHGC’s between their “dark” (or tinted) state and the clear state were: (0.22 - 0.70, termed “high” SHGC); (0.16 - 0.39, termed “low” SHGC); and (0.13 - 0.19; termed “very low” SHGC). These glazings are compared to conventional (static) glazing that meets the ASHRAE Standard 90.1-2004 energy standard for five different locations in the U.S. All analysis used the EnergyPlus building energy simulation program for modeling EC windows and alternative control strategies. The simulations were conducted for a small and a medium office building, where engineering specifications were taken from the set of Commercial Building Benchmark building models developed by BTP. On the basis of these simulations, total source-level savings in these buildings were estimated to range between 2 to 7%, depending on the amount of window area and building location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Geotech SMART24BH 20Vpp/5Vpp data acquisition system with active fortezza crypto card data signing and authentication.

Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIA crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.

99 GENERAL AND MISCELLANEOUS↗

A Laser Interferometric Miniature Sensor

This is the second year of a Phase II Small Business Innovation Research (SBIR) contract geared towards the development of a new seismic sensor. Ground-based seismic monitoring systems have proven to be very capable in identifying nuclear tests, and can provide somewhat precise information on the location and yield of the explosive device. Making these measurements, however, currently requires very expensive and bulky seismometers that are difficult to deploy in places where they are most needed. A high performance, compact device can enable rapid deployment of large scale arrays, which can in turn be used to provide higher quality data during times of critical need. The use of a laser interferometer-based device has shown considerable promise, while also presenting significant challenges. The greatest strength of this optical readout technique is the ability to decouple the mechanical design from the transducer, thus enabling a miniaturized design that is not accessible with conventional sensing techniques. However, the nonlinearity in the optical response must be accounted for in the sensor output. Previously, we had proposed using a force-feedback approach to position the sensor at a point of maximum linearity. However, it can be shown that the combined nonlinearities of the optical response and the force-feedback curve necessarily results in a significant amount of unwanted noise at low frequencies. Having realized this, we have developed a new approach that eliminates force feedback, allowing the proof mass to move freely at all times. This takes advantage of some advanced optical spatial filtering that was developed at Symphony Acoustics for other types of sensors, and was recently adapted to this work. After processing the signals in real time, the digital output of the device is intrinsically linear, and the sensor can operate at any orientation with the same level of resolution, while instantly adapting to significant changes in orientation. Ultimately, we expect the dynamic range to be up to 180 dB. Currently, we have observed the noise floor in a 0.1 Hz to 10 Hz bandwidth to be near -160 dB/Hz relative to 1 m2/s4. To meet the objectives of this program, we are finalizing the design of a 3 axis sensor for shallow borehole deployments, with a diameter of 40 mm and a length a 150 mm.

47 OTHER INSTRUMENTATION↗

UNAP DCM Theory of Operations

The UNAP DCM board is capable of measuring currents with a dynamic range of 3 x 10 -14 A to 3 x 10 -4 A. The design of the DCM closely matches the proven N-1 minigrand family DCM design. The most significant difference is the replacement of the Actel FPGA with an SPI I/O expander. The original DCM design used an Actel FPGA to communicate with the processor over the expansion bus controling the DCM gain and filtering. The UNAP processor communicates with the UDA FPGA over the cPCI bus. The UNAP DCM control functions are accomplished in the UDA FPGA and communicated to the DCM board via an SPI bus.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Digital attenuator design

This document describes the design and operation of a electronic digital step attenuator. This attenuator was designed with a 1 dB step resolution and 0.1 dB accuracy with a bandwidth from 1 to 10 MHz. The attenuator dynamic range provides attenuation of input signals from zero to 63 dB in 1 dB steps using a rotary control. A linear array of LEDs is used to display the attenuation value as a 6-bit binary value.

Robertson, Perry J.↗

Development, Manufacturing, and Preparation for Serial Production of Low Noise Seismometers (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Refraction Technology, Inc. (REF TEK), to collaborate on the development of a broadband, competitive low-noise seismometer, rugged and easy to use for field deployments. The work involved collaborative work between LLNL, REF TEK and a group led by Federal State Unitary Enterprise, Research Institute of Pulse Technique (RIPT), Moscow, Russia. The proposed work focused on bringing an improved version of the Russian SDSE seismometer from development phase to production in two versions. The first was a very low cost, rugged, broadband seismometer for field deployment that would achieve noise levels comparable to the standard earth low noise model (LNM) of the USGS. All three components were integrated into one case, and have sensitivity near 2000 v/m/s, and analog output with bandwidth of .01 to 40 Hz with high coherence. The second phase of development combined the results of previous instruments and these tests, and lowered the internal noise according to class A of standard Advanced National Seismic System (ANSS) within the band of 0.01 to 50 Hz for a dynamic range 143 - 128 dB. The second phase extended the development using improved electronics and modifications suggested by these tests of the earlier prototypes. These sensors would also be very competitive and aimed towards major improvements in their ruggedness compared to existing sensors from other manufacturers. Prototypes would undergo extensive testing at low-noise field sites for durability and functionality. The development would yield production prototypes capable of serial production at RPZ in Moscow. The collaboration between the Russian and US partners would improve the availability of rugged, broadband seismometers for commercial applications, research applications, seismic networks operated by our government and international organizations, and a spur collaboration on the development of additional types of seismometers.

Vergino, Eileen S.↗

Adaptive Liquid Crystal Windows

Energy consumption by private and commercial sectors in the U.S. has steadily grown over the last decade. The uncertainty in future availability of imported oil, on which the energy consumption relies strongly, resulted in a dramatic increase in the cost of energy. About 20% of this consumption are used to heat and cool houses and commercial buildings. To reduce dependence on the foreign oil and cut down emission of greenhouse gases, it is necessary to eliminate losses and reduce total energy consumption by buildings. To achieve this goal it is necessary to redefine the role of the conventional windows. At a minimum, windows should stop being a source for energy loss. Ideally, windows should become a source of energy, providing net gain to reduce energy used to heat and cool homes. It is possible to have a net energy gain from a window if its light transmission can be dynamically altered, ideally electronically without the need of operator assistance, providing optimal control of the solar gain that varies with season and climate in the U.S. In addition, the window must not require power from the building for operation. Resolution of this problem is a societal challenge and of national interest and will have a broad global impact. For this purpose, the year-round, all-climate window solution to provide an electronically variable solar heat gain coefficient (SHGC) with a wide dynamic range is needed. AlphaMicron, Inc. (AMI) developed and manufactured 1ft × 1ft prototype panels for the world’s first auto-adjusting Adaptive Liquid Crystal Windows (ALCWs) that can operate from sunlight without the need for external power source and demonstrate an electronically adjustable SHGC. This novel windows are based on AlphaMicron’s patented e-Tint ® technology, a guest-host liquid crystal system implemented on flexible, optically clear plastic films. This technology is suitable both for OEM and aftermarket (retro-fitting) lamination to new and existing windows. Low level of power consumption by ALCWs allows for on-board power electronics for automatic matching of transmission through windows to varying climate conditions without drawing the power from the power grid. ALCWs are capable of transmitting more sunlight in winters to assist in heating and less sunlight in summers to minimize overheating. As such, they can change the window from being a source of energy loss to a source of energy gain. In addition, the scalable AMI’s roll-to-roll process, proved by making 1ft × 1ftALCW prototype panels, allows for cost-effective production of large-scale window panels along with capability to change easily their color and shape. In addition to architectural glazing in houses and commercial buildings, ALCWs can be used in other applications where control of sunlight is needed, such as green houses, used by commercial produce growers and botanical gardens, cars, aircrafts, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Requirements Document for the Redesign of the DIM-based Diagnostics Transport and Handling System at the National Ignition Facility (NIF)

The National Ignition Facility (NIF, Figure 1) is the world’s leading user research facility for inertial confinement fusion. Diagnostic instruments that collect data from the experiment shots are transported around the facility using a series of disjointed, suboptimal transport and handling (T&H) subsystems that compromise user efficiency and ergonomics. Significant time savings and improvements to the diagnostic exchange process could be realized by designing a new transport and handling system that minimizes the hand-offs between T&H subsystems, reduces operator hassle and ergonomic strain, and improves the long-term maintainability of the system. In contrast to the current system – which employs several manually-operated carts and containers to transport the diagnostic, dock it to its destination, and install it – the new diagnostic transporter integrates the contamination container with the transport cart and provides a dynamic range of adjustability to interface with its destination. This single transporter has the requisite maneuverability, height adjustability, and fine adjustment capabilities without any rigging transactions to support contaminated diagnostic transport and handling at the alignment station and Equatorial and Polar DIMs. A remote-controlled user interface device allows operators a more hands-off experience that reduces ergonomic strain and improves safety. Assuming the cost is not prohibitive, diagnostic storage will be accomplished by simply stowing the transporter in its lowest position in the designated area of NIF. This concept for a new diagnostic transport and handling system would be better aligned with the core values of NIF: safety, quality, and reliability.

42 ENGINEERING↗

MB3a Infrasound Sensor Evaluation.

Sandia National Laboratories has tested and evaluated a new infrasound sensor, the MB3a, manufactured by Seismo Wave. These infrasound sensors measure pressure output by a methodology developed by researchers at the French Alternative Energies and Atomic Energy Commission (CEA) and the technology was recently licensed to Seismo Wave for production and sales. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, seismic sensitivity, and self- calibration ability. The MB3a infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

Merchant, Bion J.↗

UT-NE Radiation Instrumentation Research Group Meeting: An Update on Progress

The purpose of this project is to design a system to image large and/or thick objects with high dynamic ranges using an intensified, charge coupled device (CCD) camera and a fast-pulsed, high energy neutron source; Improve image resolution by reducing scatter; and Design ultra-fast scintillator using nanotechnology to allow for better timing (and thus better scatter rejection).

07 ISOTOPE AND RADIATION SOURCES↗

A High Temperature-Tolerant and Radiation-Resistant In-Core Neutron Sensor for Advanced Reactors. Final report

The objectives of this project are to develop a small and reliable gallium nitride (GaN) neutron sensor that is capable of withstanding high neutron fluence and high temperature, isolating gamma background, and operating in a wide dynamic range. The first objective will be the understanding of the fundamental materials properties and electronic response of a GaN semiconductor materials and device in an environment of high temperature and intense neutron field. To achieve such goal, an in-situ study of electronic properties of GaN device such as I-V, leakage current, and charge collection efficiency (CCE) in high temperature using an external neutron beam will be designed and implemented. We will also perform in-core irradiation of GaN up to the highest yet fast neutron fluence and an off-line performance evaluation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of three refurbished Guralp CMG-3TB seismometers.

The overall objective of testing the Guralp CMG-3TB refurbished seismometers is to determine whether or not the refurbished sensors exhibit better data quality and require less maintenance when deployed than the original Guralp CMG-3TBs. SNL will test these 3 refurbished Guralps to verify performance specifications. The specifications that will be evaluated are sensitivity, bandwidth, self-noise, output impedance, clip-level, dynamic range over application passband, verify mathematical response and calibration response parameters for amplitude and phase.

58 GEOSCIENCES↗

Hyperion 5113/GP Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/GP manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, and seismic sensitivity. These sensors are being evaluated prior to deployment by the U.S. Air Force.

47 OTHER INSTRUMENTATION↗

Hyperion 5113/A Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Intermediate Energies for Nuclear Astrophysics and the Development of a Position Sensitive Microstrip Detector System

The chemical elements are made at astrophysical sites through a sequence of nuclear reactions often involving unstable nuclei. The overarching aim of this project is to construct a system that allows for the inverse process of nucleosynthesis (i.e. breakup of heavier nuclei into lighter ones) to be studied in high efficiency. The specific problem to be overcome with this grant is inadequate dynamic range and (triggering) threshold to detect the products of the breakup which include both heavy ions (with large energy and large deposited energy in a detector system) and protons (with little energy and deposited energy.) Early on in the grant we provided both TAMU and RIKEN (the site of the eventual experiments) with working systems based on the existing technology. This technology could be used with either an external preamplifier that was to be designed and fabricated by our RIKEN collaborators or upgraded by replacing the existing chip with one we designed. The RIKEN external preamplifier project never can to completion but our revised chip was designed, fabricated, used in a test experiment and performs as required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗