Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

2021 Small Turbine Certification Awardee: Intergrid LLC

Currently, there are no U.S., fully certified inverters for wind turbines in the 10-15-kilowatt (kW) range. The federal government's Competitiveness Improvement Project (CIP) and Small Business Innovation Research programs present the most viable paths for manufacturers in the distributed wind energy industry to conduct research, develop their products, and, ultimately, commercialize them. Through CIP, Intergrid LLC is reducing the cost, size, and weight of its legacy inverter for distributed wind turbines while increasing efficiency, reliability, and serviceability. To accomplish this, Intergrid will address three areas related to power electronics for distributed wind turbines: (1) Software verification and functional safety certification; (2) Simulation for grid-interconnecting testing; (3) Component alternatives that reduce cost and improve reliability and serviceability. The first two areas relate to long-term management of inverter software, which, for grid-connected inverters, must comply with three standards - one issued by Underwriters Laboratories (UL) and two issued by the Institute of Electrical and Electronics Engineers.

CIP↗

Sustainable Port Operations: Powered by NREL

Seaports are vital economic hubs that allow the United States to compete on a global scale. But the heavy vehicles and cargo equipment that enable their operations also emit harmful air pollutants and greenhouse gas emissions. For nearly two decades, National Renewable Energy Laboratory (NREL) researchers have worked toward comprehensive seaport decarbonization. They fuse world-class analysis with deep vehicle and transportation systems knowledge to guide strategic deployment of low- and zero-emissions vehicles, charging and refueling infrastructure, and grid improvements. Together, these capabilities can enable sustainable port operations. This fact sheet outlines major seaport and airport decarbonization capabilities across the laboratory, including: fleet research, energy data, and insights for decarbonization; comprehensive hydrogen infrastructure deployment; optimized charging through grid integration; strategic blueprinting for clean, optimized technology deployment; and integrating diversity, equity, inclusion, and accessibility considerations into decarbonization efforts.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Economic evaluation of variable renewable energy participation in U.S. ancillary services markets

Variable renewable energy (VRE) is not yet meaningfully participating in U.S. ancillary services (AS) markets. VRE participation in AS markets could provide a new source of revenue for VRE resource owners to offset declining energy and capacity values and a new tool for power system operators to address emerging system constraints. This paper uses a price-taker dispatch model and historical prices to estimate the economic value of standalone and hybrid (battery-paired) VRE participation in AS markets, from the resource owner and electricity system perspectives, in each of the seven U.S. independent system operator and regional transmission organization (ISO/RTO) markets where ancillary service prices are set. Across ISO/RTO markets, average (2015–2019) simulated incremental revenues from power regulation market participation were 0.0–2.9 USD/MWh (+0–15% of revenue without participation) for standalone VRE owners and 1–33 USD/MWh (+1–69%) for hybrid VRE owners. However, ISO/RTO reserve markets are relatively thin and have the potential to become saturated by energy storage projects that are currently in ISO/RTO interconnection queues. In most markets, standalone and hybrid VRE could provide power regulation reserves during periods with high power regulation prices, suggesting that VRE participation in AS markets could have high system value. The analysis highlights the relevance of separate upward and downward power regulation products and indicates that ISOs/RTOs might consider initially focusing on enabling hybrid VRE provision of AS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interconnection of thermal parameters, microstructure and mechanical properties in directionally solidified Sn–Sb lead-free solder alloys

Considerable effort is being made to develop lead-free solders for assembling in environmental-conscious electronics, due to the inherent toxicity of Pb. The search for substitute alloys of Pb–Sn solders has increased in order to comply with different soldering purposes. The solder must not only meet the expected levels of electrical performance but may also have appropriate mechanical strength, with the absence of cracks in the solder joints. The Sn–Sb alloy system has a range of compositions that can be potentially included in the class of high temperature solders. This study aims to establish interrelations of solidification thermal parameters, microstructure and mechanical properties of Sn–Sb alloys (2 wt.%Sb and 5.5 wt.%Sb) samples, which were directionally solidified under cooling rates similar to those of reflow procedures in industrial practice. A complete high-cooling rate cellular growth is shown to be associated with the Sn–2.0 wt.%Sb alloy and a reverse dendrite-to-cell transition is observed for the Sn–5.5 wt.%Sb alloy. Strength and ductility of the Sn–2.0 wt.%Sb alloy are shown not to be affected by the cellular spacing. On the other hand, a considerable variation in these properties is associated with the cellular region of the Sn–5.5 wt.%Sb alloy casting. - Graphical abstract: Display Omitted - Highlights: • The microstructure of the Sn–2 wt.%Sb alloy is characterized by high-cooling rates cells. • Reverse dendrite > cell transition occurs for Sn–5.5 wt.%Sb alloy: cells prevail for cooling rates > 1.2 K/s. • Sn–5.5 wt.%Sb alloy: the dendritic region occurs for cooling rates < 0.9 K/s. • Sn–5.5 wt.%Sb alloy: tensile properties are improved with decreasing cellular spacing.

36 MATERIALS SCIENCE↗

Spectral shifts and switches in random fields upon interaction with negative-phase materials

Spectral shifts in stochastic beam-like fields on interaction with layers of positive- and negative-phase materials are examined on the basis of the ABCD-matrix approach and generalized Huygens-Fresnel principle. It is found that boundaries between such materials may cause spectral switches. Effect of absorption of negative-phase materials on the beam spectrum is discussed. Our results may find applications in connection with spectrum-selection optical interconnects, spectrally encoded information transfer, image formation in systems involving negative-phase materials, and geometrically tunable metamaterials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graph Laplacian Spectrum and Primary Frequency Regulation: Preprint

We present a framework based on spectral graph theory that captures the interplay among network topology, system inertia, and generator and load damping in determining overall power grid behavior and performance. Specifically, we show that the impact of network topology on a power system can be quantified through the network Laplacian eigenvalues, and such eigenvalues determine the grid robustness against low frequency disturbances. Moreover, we can explicitly decompose the frequency signal along scaled Laplacian eigenvectors when damping-intertia ratios are uniform across buses. The insight revealed by this framework suggests why load-side participation in frequency regulation not only makes the system respond faster, but also helps lower the system nadir after disturbance. Finally, by presenting a new controller specifically tailored to suppress high frequency disturbances, we demonstrate that our results can provide useful guidelines in the controller design for load-side primary frequency regulation. We simulate the improved controller on the IEEE 39-bus New England interconnection system to illustrate its robustness against high frequency oscillation compared to both the conventional droop control and a recent controller design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Superconductivity devices: Commercial use of space

High T sub C superconducting thick film were prepared by a screen printing process. Y-based (YBa2Cu3O(7-x) superconducting thick film were printed on 211/Al2O3, SNT/Al2O3, and YSZ substrates. Because of poor adhesion of the superconductor thick films to 211/Al2O3 and SNT/Al2O3 substrates, relatively low T sub C and J sub C values were obtained from the films printed on these substrates. Critical temperatures (T sub C) of YBa2Cu3O(7-x) thick films deposited on 211/Al2O3 and SNT/Al2O3 substrates were about 80 K. The critical current densities (J sub C) of these films were less than 2 A/sq cm. Higher T sub C and J sub C YBa2Cu3O(7-x) thick films were printed on YSZ substrates. A YBa2Cu3O(7-x) thick film with T sub C=86.4 and J sub C= 50.4 A/sq cm was prepared by printing the film on YSZ substrate and firing at 990 C for 10 minutes. Multiple-lead samples were also prepared on the YSZ substrates. The multiple-lead samples showed lower T sub C and/or J sub C values than those of the plain samples. The electrical properties of YBa2Cu3O(7-x) thick films were determined by the microstructures of the films. The YBa2Cu3O(7-x) thick films printed on the YSZ substrates, which had the best properties among the films printed on the three different kinds of substrates, had the highest density and the best particle interconnection. The YBa2Cu3O(7-x) thick films with preferred orientation in (001) direction were obtained on the YSZ substrates. Cracks, which retard the properties of the films, were found from the films deposited on the YSZ substrates. Currently, a MSZ (Magnesium Stabilized Zirconia) substrate, which had higher thermal expansion coefficient than the YSZ substrate, is used as substrate for the YBa2Cu3O(7-x) thick film in order to eliminate the cracks on the film. Bi-based superconductor thick films were printed on polycrystalline MgO and YSZ substrates. Interactions between BSCCO thick films and the YSZ substrates were observed. Various buffer layer materials were applied onto the substrates in order to avoid the interactions between the BSCCO thick films and the ZrO2-based substrates. So far, a BSCCO printed on MgO substrate with T Sub C=89K was obtained. The J sub C of the film was lower than 0.1 A/sq cm by reason of poor interconnectivity of the BSCCO particles.

Haertling, Gene↗

Analysis of Advanced Thermoelectric Materials and Their Functional Limits

The world's demand for energy is increasing dramatically, but the best energy conversion systems operate at approximately 30% efficiency. One way to decrease energy loss is in the recovery of waste heat using thermoelectric (TE) generators. A TE generator is device that generates electricity by exploiting heat flow across a thermal gradient. The efficiency of a TE material for power generation and cooling is determined by the dimensionless Figure of Merit (ZT): ZT = S(exp. 2)sigmaT/κ: where S is the Seebeck coefficient, sigma is the electrical conductivity, T is the absolute temperature, and κ is the thermal conductivity. The parameters are not physically independent, but intrinsically coupled since they are a function of the transport properties of electrons. Traditional research on TE materials has focused on synthesizing bulk semiconductor-type materials that have low thermal conductivity and high electrical conductivity affording ZT values of 1. The optimization of the σ/κ ratio is difficult to achieve using current material formats, as these material constants are complementary. Recent areas of research are focusing on using nanostructural artifacts that introduce specific dislocations and boundary conditions that scatter the phonons. This disrupts the physical link between thermal (phonon) and electrical (electron) transport. The result is that κ is decreased without decreasing σ. These material formats give ZT values of up to 2 which represent approximately 18% energy gain from waste heat recovery. The next challenge in developing the next generation of TE materials with superior performance is to tailor the interconnected thermoelectric physical parameters of the material system. In order to approach this problem, the fundamental physics of each parameter S, sigma, and κ need to be physically understood in their context of electron/phonon interaction for the construction of new high ZT thermoelectric devices. Is it possible to overcome the physical limit imposed by of the effect of phonon lattice oscillation and energetic electrons towards thermal conductivity? Is the Seebeck coefficient, based on the difference in voltage over temperature gradient ( deltaV/deltaT), an intrinsic parameter of each material? All these parameters were manipulated using nano-bridge and twin-lattice structural concepts at the NASA Langley Research Center. This talk will review the current trend of TE research to optimize the ZT and discuss about new approaches on increasing ZT within functional limits of each parameter.

Kim, Hyun Jung↗

100 MW e Baseload Molten Salt Plant Phase 1 & 2 Summary Report: Summary of Conceptual Design, Preliminary Design, Commercialization and Risk Reduction Activities

This document describes steps taken to develop our conceptual and preliminary designs of a modular concept for deploying a 75% capacity factor, 100-MW e solar power plant. The modular approach consists of 14 solar power towers interconnected by hot and cold salt piping leading back to a central power block where the salt storage tanks and power generation systems are located. The plant is described in several sections. First, the overall plant is described, including the general arrangement, process and heat flow diagrams, system interface definitions, and electrical description. Next, each system is described in detail following the flow of energy from incident sunlight, through the plant, to the grid. These systems include the solar collector system (SCS), solar receiver system (SRS), thermal storage system (TSS), steam generator system (SGS), and power generation system (PGS). Then, the plant control system (PCS) and balance of plant (BOP) are discussed as supporting entities. Each system of the plant is described in sufficient detail to allow for the following to be developed: material cost, erection cost, project schedule, EPC bids, detailed performance modeling, and operations and maintenance cost. Cost, schedule, and performance estimates are not described in this document. Two approaches to demonstration of the technology are presented: a single tower integrated into an existing power block and a four tower stand alone 50 MW e power plant. Various demonstration partners have expressed interested in both approaches. The process by which a detailed plant performance model was developed is described to support the development of accurate LCOE data. Information on material and instrument testing is also provided for critical materials and instruments required for molten salt service.

14 SOLAR ENERGY↗

Electric power distribution and load transfer system

A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

Bradford, Michael P.↗

Electric power distribution and load transfer system

A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

Bradford, Michael P.↗

Refueling-station costs for metal hydride storage tanks on board hydrogen fuel cell vehicles

Refueling costs account for much of the fuel cost for light-duty hydrogen fuel-cell electric vehicles. We estimate cost savings for hydrogen dispensing if metal hydride (MH) storage tanks are used on board instead of 700-bar tanks. Here, we consider a low-temperature, low-enthalpy scenario and a high-temperature, high-enthalpy scenario to bracket the design space. The refueling costs are insensitive to most uncertainties. Uncertainties associated with the cooling duty, coolant pump pressure, heat exchanger (HX) fan, and HX operating time have little effect on cost. The largest sensitivities are to tank pressure and station labor. The cost of a full-service attendant, if the refueling interconnect were to prevent self-service, is the single largest cost uncertainty. MH scenarios achieve 0.71–0.75/kg-H 2 savings by reducing compressor costs without incurring the cryogenics costs associated with cold-storage alternatives. Practical refueling station considerations are likely to affect the choice of the MH and tank design.

08 HYDROGEN↗

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Utility Solar Generation Valuation Methods

Tucson Electric Power (TEP) developed, tested and verified the results of a new and appropriate method for accurately evaluating the capacity credit of time variant solar generating sources and reviewed new methods to appropriately and fairly evaluate the value of solar generation to electric utilities. The project also reviewed general integrated approaches for adequately compensating owners of solar generation for their benefits to utilities. However, given the limited funding support and time duration of this project combined with the significant differences between utilities regarding rate structures, solar resource availability and coincidence of solar generation with peak load periods, it is well beyond the scope of this project to develop specific rate, rebate, and interconnection approaches to capture utility benefits for all possible utilities. The project developed computer software based evaluation method models to compare solar generation production data measured in very short term time increments called Sample Intervals over a typical utility Dispatch Cycle during an Evaluation Period against utility system load data. Ten second resolution generation production data from the SGSSS and actual one minute resolution TEP system load data for 2006 and 2007, along with data from the Pennington Street Garage 60 kW DC capacity solar unit installed in downtown Tucson will be applied to the model for testing and verification of the evaluation method. Data was provided by other utilities, but critical time periods of data were missing making results derived from that data inaccurate. The algorithms are based on previous analysis and review of specific 2005 and 2006 SGSSS production data. The model was built, tested and verified by in house TEP personnel. For this phase of the project, TEP communicated with, shared solar production data with and collaborated on the development of solar generation valuation tools with other utilities, including Arizona Public Service, Salt River Project, Xcel and Nevada Power Company as well as the Arizona electric cooperatives. In the second phase of the project, three years of 10 second power output data of the SGSSS was used to evaluate the effectiveness of frequency domain analysis, normal statistical distribution analysis and finally maximum/minimum differential output analysis to test the applicability of these mathematic methods in accurately modeling the output variations produced by clouds passing over the SGSSS array.

14 SOLAR ENERGY↗

Catalina Repower Feasibility Study: NREL Phases I & II Summary Report

Engineers at the National Renewable Energy Laboratory (NREL) supported Southern California Edison (SCE) and the United States Environmental Protection Agency (EPA) by conducting technical and economic analyses for energy systems at Santa Catalina (Catalina) Island, which is located 22 miles off the coast of Long Beach, California. This effort was part of a broader Repower Catalina Feasibility Study that was also supported by NV5, an engineering consulting firm and project partner to NREL for this analysis. This document describes NREL’s techno-economic modeling and optimization analysis for the first two phases of this project which focus on supply-side generation and energy storage options for Catalina. SCE’s goal for this analysis is to determine a strategy for electricity generation on Catalina Island that results in lower energy costs, improved energy resiliency, and reduced air emissions. EPA goals for this effort are to reduce emissions of air pollution and encourage renewable energy development on contaminated and formerly contaminated lands when such development is aligned with the community’s vision for the site. Currently, an on-island SCE power plant serves the Catalina Island electrical load with 6 reciprocating diesel generators totaling 9.4 MW; 23 propane-fueled microturbines totaling 1.5 MW; and a 1-MW, 7.2-MWh sodium sulfur battery energy storage system (BESS). In 2017, the electricity consumption on the island was 29.1 GWh, with an average load of 3.3 MW and peak load of approximately 5.5 MW. Considering new environmental standards on diesel generator emissions from California’s South Coast Air Quality Management District, a 60% renewable energy target for 2030 laid out in California’s Senate Bill 100, SCE’s Clean Power Electrification Pathway, and the characteristics of the island’s existing diesel generators, SCE is seeking to evaluate the technical and economic implications of different energy technology options to determine a path forward. Phases I and II of the Repower Catalina Feasibility Study, summarized in this document, evaluated the following: Interconnection with the mainland via an undersea cable; On-island fossil fuel generation, including diesel, propane, and/or liquified natural gas (LNG); On-island renewable energy (RE) technologies, including solar photovoltaics (PV), wind turbines, and wave energy devices; BESS to support the above generation technologies; Initial analysis of the potential impacts of implementing energy efficiency measures. Results indicate strong techno-economic potential for a mix of on-island diesel and/or propane generators, solar PV, BESS, and energy efficiency measures to help SCE and Catalina achieve their goals compliant with California’s emissions and clean energy standards while minimizing electricity life cycle costs (LCC) over the 30-year analysis period. This document summarizes the considerations and findings of Phases I and II, focusing on high-level takeaways from Phase I and more detailed results from Phase II, and discusses a potential path forward for Phase III.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Compliant alkali silicate sealing glass for solid oxide fuel cell applications: thermal cycle stability and chemical compatibility

An alkali silicate glass (SCN-1) is currently being evaluated as a candidate sealing glass for solid oxide fuel (SOFC) applications. The glass containing ~17 mole% alkalis (K2O and Na2O) remains vitreous and compliant during SOFC operation, unlike conventional SOFC sealing glasses, which experience substantial devitrification after the sealing process. The non-crystallizing compliant sealing glass has lower glass transition and softening temperatures since the microstructure remains glassy without significant crystallite formation, and hence can relieve or reduce residual stresses and also has the potential for crack healing. Sealing approaches based on compliant glass will also need to satisfy all the mechanical, thermal, chemical, physical, and electrical requirements for SOFC applications, not only in bulk properties but also at sealing interfaces. In this first of a series of papers we will report the thermal cycle stability of the glass when sealed between two SOFC components, i.e., a NiO/YSZ anode supported YSZ bilayer and a coated ferritic stainless steel interconnect material. High temperature leak rates were monitored versus thermal cycles between 700-850oC using back pressures ranging from 0.2 psi to 1.0 psi. Isothermal stability was also evaluated in a dual environment consisting of flowing dilute H2 fuel versus ambient air. In addition, chemical compatibility at the alumina and YSZ interfaces was examined with scanning electron microscopy and energy dispersive spectroscopy. The results shed new light on the topic of SOFC glass seal development.

30 DIRECT ENERGY CONVERSION↗

Performance degradation in proton-conducting ceramic fuel cell and electrolyzer stacks

Proton-conducting ceramics are emerging as enabling materials for efficient electrochemical electricity generation, energy storage, and fuels synthesis. In this work, we present longer-term degradation results for protonic-ceramic fuel cells and electrolyzers based on a BaCe 0.4 Zr 0.4 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) electrolyte. The cells are packaged within unit-cell stacks, including metallic interconnects, current collectors, sealing glasses and gaskets. Durability is found to be superior in protonic-ceramic electrolyzers in comparison to fuel cells. Operating conditions have a large impact on degradation rates; better stability is found at fuel-cell operating temperatures above 600 °C, and electrolyzer steam feeds below 20%. Here, we find that both fuel-cell and electrolyzer degradation is greatly reduced via the introduction of a gadolinium-doped ceria interlayer between the electrolyte and the air–steam electrode. Fuel-cell degradation falls to 1.2% khr –1 under methane fuel at 600 °C; electrolyzer degradation is reduced to 1% khr –1 at 550 °C and 50% steam. Further analyses of electrochemical impedance spectroscopy and distribution of relaxation times provide insight to root processes and degradation phenomena in protonic electroceramics.

25 ENERGY STORAGE↗

Navigating Integration: Key Challenges for Data Centers, Nuclear Stakeholders, and Utility Operators

The rapid expansion of data centers, driven by the exponential growth in data-processing and storage needs, presents significant challenges and opportunities for various stakeholders, including data center developers, nuclear energy providers, and utility companies. Data centers are projected to consume 6.7–12% of United States (U.S.) electricity by 2028, driven by artificial intelligence (AI) and cloud-computing demands. Nuclear energy offers reliability and dispatchable baseload power, but data centers need power now while nuclear still needs time to address siting, fast power ramping, and regulatory hurdles. Utilities must keep pace with the unprecedented acceleration of large load interconnection requests and urgently adapt to high-density loads while maintaining grid stability, reliability, and accelerating interconnection timelines. This report dives into these challenges and proposes key collaboration strategies to streamline data center integration that aligns with recent federal initiatives like America’s AI Action Plan and related executive orders that emphasize the importance of data center growth, nuclear energy expansion, and maintaining a competitive edge in the global AI race.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗