Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Halo Properties and Mass Functions of Groups/Clusters from the DESI Legacy Imaging Surveys DR9

Abstract Based on a large group/cluster catalog recently constructed from the DESI Legacy Imaging Surveys DR9 using an extended halo-based group finder, we measure and model the group–galaxy weak-lensing signals for groups/clusters in a few redshift bins within redshift range 0.1 ≤ z < 0.6. Here, the background shear signals are obtained based on the DECaLS survey shape catalog, derived with the F ourier _Q uad method. We divide the lens samples into five equispaced redshift bins and seven mass bins, which allow us to probe the redshift and mass dependence of the lensing signals, and hence the resulting halo properties. In addition to these sample selections, we also check the signals around different group centers, e.g., the brightest central galaxy, the luminosity-weighted center, and the number-weighted center. We use a lensing model that includes off-centering to describe the lensing signals that we measure for all mass and redshift bins. The results demonstrate that our model predictions for the halo masses, biases, and concentrations are stable and self-consistent among different samples for different group centers. Taking advantage of the very large and complete sample of groups/clusters, as well as the reliable estimations of their halo masses, we provide measurements of the cumulative halo mass functions up to redshift z = 0.6, with a mass precision at 0.03 ∼ 0.09 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

Perceptual Image Compression in Telemedicine

The next era of space exploration, especially the "Mission to Planet Earth" will generate immense quantities of image data. For example, the Earth Observing System (EOS) is expected to generate in excess of one terabyte/day. NASA confronts a major technical challenge in managing this great flow of imagery: in collection, pre-processing, transmission to earth, archiving, and distribution to scientists at remote locations. Expected requirements in most of these areas clearly exceed current technology. Part of the solution to this problem lies in efficient image compression techniques. For much of this imagery, the ultimate consumer is the human eye. In this case image compression should be designed to match the visual capacities of the human observer. We have developed three techniques for optimizing image compression for the human viewer. The first consists of a formula, developed jointly with IBM and based on psychophysical measurements, that computes a DCT quantization matrix for any specified combination of viewing distance, display resolution, and display brightness. This DCT quantization matrix is used in most recent standards for digital image compression (JPEG, MPEG, CCITT H.261). The second technique optimizes the DCT quantization matrix for each individual image, based on the contents of the image. This is accomplished by means of a model of visual sensitivity to compression artifacts. The third technique extends the first two techniques to the realm of wavelet compression. Together these two techniques will allow systematic perceptual optimization of image compression in NASA imaging systems. Many of the image management challenges faced by NASA are mirrored in the field of telemedicine. Here too there are severe demands for transmission and archiving of large image databases, and the imagery is ultimately used primarily by human observers, such as radiologists. In this presentation I will describe some of our preliminary explorations of the applications of our technology to the special problems of telemedicine.

Watson, Andrew B.↗

Lunar and Planetary Science XXXV: Impacts: Observations and Experiments

The title in this section include: 1) Impactites of the Haughton Impact Structure, Devon Island, Nunavut, Canada; 2) Geochemical Characteristics of Impactites from the Yaxcopoil-1 ICDP Drill Core, Chicxulub Impact Structure, Mexico; 3) Investigation of the Ries Impact Crater Based upon Old and New Geophysical Data and Numerical Modeling; 4) Potential of Radar Imaging and Sounding Methods in Mapping Heavily Eroded Impact Craters: Mapping Some Structural Elements of the Hico Crater, TX; 5) From Simple to Complex Craters: The Mechanics of Late-time Crater Adjustments; 6) Impact Structures: What Does Crater Diameter Mean? 7) Early-Time Temperature Evolution of the Impact Flash and Beyond; 8) Probing Impact-Generated Vapor Plumes; 9) Non-Ballistic Vapor-Driven Ejecta; 10) Depth and Diameter of Transient Craters; 11) A Plausibility of Z-Model; 12) Experiments with Explosives and Ordnance Disposal Devices for the Simulation of Specific Processes During Shallow-Marine Impacts; 13) Collisional Fragmentation of Rotating Bodies.

Source record↗

Space Transportation System Liftoff Debris Mitigation Process Overview

Liftoff debris is a top risk to the Space Shuttle Vehicle. To manage the Liftoff debris risk, the Space Shuttle Program created a team with in the Propulsion Systems Engineering & Integration Office. The Shutt le Liftoff Debris Team harnesses the Systems Engineering process to i dentify, assess, mitigate, and communicate the Liftoff debris risk. T he Liftoff Debris Team leverages off the technical knowledge and expe rtise of engineering groups across multiple NASA centers to integrate total system solutions. These solutions connect the hardware and ana lyses to identify and characterize debris sources and zones contribut ing to the Liftoff debris risk. The solutions incorporate analyses sp anning: the definition and modeling of natural and induced environmen ts; material characterizations; statistical trending analyses, imager y based trajectory analyses; debris transport analyses, and risk asse ssments. The verification and validation of these analyses are bound by conservative assumptions and anchored by testing and flight data. The Liftoff debris risk mitigation is managed through vigilant collab orative work between the Liftoff Debris Team and Launch Pad Operation s personnel and through the management of requirements, interfaces, r isk documentation, configurations, and technical data. Furthermore, o n day of launch, decision analysis is used to apply the wealth of ana lyses to case specific identified risks. This presentation describes how the Liftoff Debris Team applies Systems Engineering in their proce sses to mitigate risk and improve the safety of the Space Shuttle Veh icle.

Mitchell, Michael↗

NO PLIF Visualizations of the Orion Capsule in LENS-I

Planar laser-induced fluorescence (PLIF) of nitric oxide (NO) was used to visualize the interaction of reaction-control-system (RCS) jet flows in the wake of a hypersonic capsule reentry vehicle. The tests were performed at the Calspan University at Buffalo Research Center's (CUBRC) LENS-I reflected shock tunnel facility. This was the first application of PLIF to study RCS jets in a large-scale pulsed hypersonic facility. The LENS-I facility allowed RCS jet flows to be studied while varying the flow enthalpy, Reynolds number, angle of attack and jet configuration. The interaction of pitch and roll jets with the flowfield was investigated. Additionally, thin film sensors were used to monitor heat transfer on the surface of the model to detect any localized heating resulting from the firing of the RCS jets. Tests were conducted with the model held at angles of attack of 18deg and 22deg. The nominal Mach number in all tests was 8, while Reynolds number based on model diameter ranged from 2.2x10(exp 6) - 1.5x10(exp 7). Images were processed using the Virtual Diagnostics Interface (ViDI) system developed at NASA Langley Research Center to provide a three-dimensional display of the experimental data.

Combs, C.↗

Apocenter Glow in Eccentric Debris Disks: Implications for Fomalhaut and Epsilon Eridani

Debris disks often take the form of eccentric rings with azimuthal asymmetries in surface brightness. Such disks are often described as showing pericenter glow, an enhancement of the disk brightness in regions nearest the central star. At long wavelengths, however, the disk apocenters should appear brighter than their pericenters: in the long-wavelength limit, we find that the apocenter pericenter flux ratio scales as 1 + e for disk eccentricity e. We produce new models of this apocenter glow to explore its causes and wavelength dependence and study its potential as a probe of dust grain properties. Based on our models, we argue that several far-infrared and (sub)millimeter images of the Fomalhaut and Epsilon Eridani debris rings obtained with Herschel, JCMT, SHARC II, ALMA, and ATCA should be reinterpreted as suggestions or examples of apocenter glow. This reinterpretation yields new constraints on the disks dust grain properties and size distributions.

Fomalhaut and Eridani debris rings↗

MOSAIC: a new wavefront metrology

MOSAIC is a new wavefront metrology that enables complete wavefront characterization from print or aerial image based measurements. Here we describe MOSAIC and verify its utility with a model-based proof of principle.

36 MATERIALS SCIENCE↗

Principal Component-Based Radiative Transfer Model (PCRTM) for Hyperspectral Sensors: Theoretical Concept - Part I

Modern infrared satellite sensors such as Atmospheric Infrared Sounder (AIRS), Cosmic Ray Isotope Spectrometer (CrIS), Thermal Emission Spectrometer (TES), Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) and Infrared Atmospheric Sounding Interferometer (IASI) are capable of providing high spatial and spectral resolution infrared spectra. To fully exploit the vast amount of spectral information from these instruments, super fast radiative transfer models are needed. This paper presents a novel radiative transfer model based on principal component analysis. Instead of predicting channel radiance or transmittance spectra directly, the Principal Component-based Radiative Transfer Model (PCRTM) predicts the Principal Component (PC) scores of these quantities. This prediction ability leads to significant savings in computational time. The parameterization of the PCRTM model is derived from properties of PC scores and instrument line shape functions. The PCRTM is very accurate and flexible. Due to its high speed and compressed spectral information format, it has great potential for super fast one-dimensional physical retrievals and for Numerical Weather Prediction (NWP) large volume radiance data assimilation applications. The model has been successfully developed for the National Polar-orbiting Operational Environmental Satellite System Airborne Sounder Testbed - Interferometer (NAST-I) and AIRS instruments. The PCRTM model performs monochromatic radiative transfer calculations and is able to include multiple scattering calculations to account for clouds and aerosols.

Liu, Xu↗

ICER-3D Hyperspectral Image Compression Software

Software has been developed to implement the ICER-3D algorithm. ICER-3D effects progressive, three-dimensional (3D), wavelet-based compression of hyperspectral images. If a compressed data stream is truncated, the progressive nature of the algorithm enables reconstruction of hyperspectral data at fidelity commensurate with the given data volume. The ICER-3D software is capable of providing either lossless or lossy compression, and incorporates an error-containment scheme to limit the effects of data loss during transmission. The compression algorithm, which was derived from the ICER image compression algorithm, includes wavelet-transform, context-modeling, and entropy coding subalgorithms. The 3D wavelet decomposition structure used by ICER-3D exploits correlations in all three dimensions of sets of hyperspectral image data, while facilitating elimination of spectral ringing artifacts, using a technique summarized in "Improving 3D Wavelet-Based Compression of Spectral Images" (NPO-41381), NASA Tech Briefs, Vol. 33, No. 3 (March 2009), page 7a. Correlation is further exploited by a context-modeling subalgorithm, which exploits spectral dependencies in the wavelet-transformed hyperspectral data, using an algorithm that is summarized in "Context Modeler for Wavelet Compression of Hyperspectral Images" (NPO-43239), which follows this article. An important feature of ICER-3D is a scheme for limiting the adverse effects of loss of data during transmission. In this scheme, as in the similar scheme used by ICER, the spatial-frequency domain is partitioned into rectangular error-containment regions. In ICER-3D, the partitions extend through all the wavelength bands. The data in each partition are compressed independently of those in the other partitions, so that loss or corruption of data from any partition does not affect the other partitions. Furthermore, because compression is progressive within each partition, when data are lost, any data from that partition received prior to the loss can be used to reconstruct that partition at lower fidelity. By virtue of the compression improvement it achieves relative to previous means of onboard data compression, this software enables (1) increased return of hyperspectral scientific data in the presence of limits on the rates of transmission of data from spacecraft to Earth via radio communication links and/or (2) reduction in spacecraft radio-communication power and/or cost through reduction in the amounts of data required to be downlinked and stored onboard prior to downlink. The software is also suitable for compressing hyperspectral images for ground storage or archival purposes.

Xie, Hua↗

Stereotactic Body Radiotherapy for Lesions of the Spine and Paraspinal Regions

Purpose: To describe our experience and clinical strategy for stereotactic body radiotherapy (SBRT) of spinal lesions. Methods and Materials: Thirty-two patients with 33 spinal lesions underwent computed tomography-based simulation while free breathing. Gross/clinical target volumes included involved portions of the vertebral body and paravertebral/epidural tumor. Planning target volume (PTV) expansion was 6 mm axially and 3 mm radially; the cord was excluded from the PTV. Biologic equivalent dose was calculated using the linear quadratic model with {alpha}/{beta} = 3 Gy. Treatment was linear accelerator based with on-board imaging; dose was adjusted to maintain cord dose within tolerance. Survival, local control, pain, and neurologic status were monitored. Results: Twenty-one patients are alive at 1 year (median survival, 14 months). Median follow-up is 6 months for all patients (7 months for survivors). Mean previous radiotherapy dose to 22 patients was 35 Gy, and median interval was 17 months. Renal (31%), breast, and lung (19% each) were the most common histologic sites. Three SBRT fractions (range, one to four fractions) of 7 Gy (range, 5-16 Gy) were delivered. Median cord and target biologic equivalent doses were 70 Gy{sub 3} and 34.3 Gy{sub 10}, respectively. Thirteen patients reported complete and 17 patients reported partial pain relief at 1 month. There were four failures (mean, 5.8 months) with magnetic resonance imaging evidence of in-field progression. No dosimetric parameters predictive of failure were identified. No treatment-related toxicity was seen. Conclusions: Spinal SBRT is effective in the palliative/re-treatment setting. Volume expansion must ensure optimal PTV coverage while avoiding spinal cord toxicity. The long-term safety of spinal SBRT and the applicability of the linear-quadratic model in this setting remain to be determined, particularly the time-adjusted impact of prior radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AutoPhaseNN: unsupervised physics-aware deep learning of 3D nanoscale Bragg coherent diffraction imaging

Abstract The problem of phase retrieval underlies various imaging methods from astronomy to nanoscale imaging. Traditional phase retrieval methods are iterative and are therefore computationally expensive. Deep learning (DL) models have been developed to either provide learned priors or completely replace phase retrieval. However, such models require vast amounts of labeled data, which can only be obtained through simulation or performing computationally prohibitive phase retrieval on experimental datasets. Using 3D X-ray Bragg coherent diffraction imaging (BCDI) as a representative technique, we demonstrate AutoPhaseNN, a DL-based approach which learns to solve the phase problem without labeled data. By incorporating the imaging physics into the DL model during training, AutoPhaseNN learns to invert 3D BCDI data in a single shot without ever being shown real space images. Once trained, AutoPhaseNN can be effectively used in the 3D BCDI data inversion about 100× faster than iterative phase retrieval methods while providing comparable image quality.

36 MATERIALS SCIENCE↗

A solar type II radio burst from coronal mass ejection-coronal ray interaction: Simultaneous radio and extreme ultraviolet imaging

Simultaneous radio and extreme ultraviolet (EUV)/white-light imaging data are examined for a solar type II radio burst occurring on 2010 March 18 to deduce its source location. Using a bow-shock model, we reconstruct the three-dimensional EUV wave front (presumably the type-II-emitting shock) based on the imaging data of the two Solar TErrestrial RElations Observatory spacecraft. It is then combined with the Nançay radio imaging data to infer the three-dimensional position of the type II source. It is found that the type II source coincides with the interface between the coronal mass ejection (CME) EUV wave front and a nearby coronal ray structure, providing evidence that the type II emission is physically related to the CME-ray interaction. This result, consistent with those of previous studies, is based on simultaneous radio and EUV imaging data for the first time.

79 ASTRONOMY AND ASTROPHYSICS↗

ThermoPore: Predicting part porosity based on thermal images using deep learning

Part qualification is often a critical and labor-intensive process in additive manufacturing, particularly in the detection of defects such as porosity, which stands to benefit significantly from advancements in machine learning. We present a deep learning approach for quantifying and localizing ex-situ porosity within Laser Powder Bed Fusion fabricated samples utilizing in-situ thermal image monitoring data. Our goal is to build the real time porosity map of parts based on thermal images acquired during the build. The quantification task builds upon the established Convolutional Neural Network model architecture to predict pore count and the localization task leverages the spatial and temporal attention mechanisms of the novel Video Vision Transformer model to indicate areas of expected porosity. Our model for porosity quantification achieved a R 2 score of 0.57 and our model for porosity localization produced an average Intersection over Union (IoU) score of 0.32 and a maximum of 1.0. This work is setting the foundations of part porosity “Digital Twins” based on additive manufacturing monitoring data and can be applied downstream to reduce time-intensive post-inspection and testing activities during part qualification and certification. In addition, we seek to accelerate the acquisition of crucial insights normally only available through ex-situ part evaluation by means of machine learning analysis of in-situ process monitoring data.

Deep learning↗

Photon Sieve Design and Fabrication for Imaging Characteristics Using UAV Flight

The Photon Sieve (PS) team at NASA Langley Research Center (LaRC) began receiving support for the development and characterization of PS devices through the NASA Internal Research & Development Program (IRAD) in 2015. The project involves ascertaining the imaging characteristics of various PS devices. These devices hold the potential to significantly reduce mission costs and improve imaging quality by replacing traditional reflector telescopes. The photon sieve essentially acts as a lens to diffract light to a concentrated point on the focal plane like a Fresnel Zone Plate (FZP). PS’s have the potential to focus light to a very small spot which is not limited by the width of the outermost zone as for the FZP and offers a promising solution for high resolution imaging. In the fields of astronomy, remote sensing, and other applications that require imaging of distant objects both on the ground and in the sky, it is often necessary to perform post-process filtering in order to separate noise signals that arise from multiple scattering events near the collection optic. The PS exhibits a novel filtering technique that rejects the unwanted noise without the need for time consuming post processing of the images. This project leverages key Langley resources to design, manufacture, and characterize a series of photon sieve specimens. After a prototype was developed and characterized in the Langley ISO5 optical cleanroom and laboratory, outside testing was conducted via the capture of images of the moon by using a telescopic setup. This next goal of the project is to design and develop a telescope and image capture system as a drone-based instrument payload. The vehicle utilized for the initial demonstration was a NASA hive model 1200 XE-8 research Unmanned Aerial Vehicle (UAV), capable of handling a 20-pound maximum payload with a 25-minute flight time. This NASA Technical Memorandum (NASA-TM) introduces preliminary results obtained using a PS-based imaging system on the UAV. The next version of the telescope structure will be designed around diffractive optical components and commercially available camera electronics to create a lightweight payload.

Kim, Hyun Jung↗

Enhancing Remote Sensing Based Yield Forecasting: Application to Winter Wheat in United States

Accurate and timely crop yield forecasts are critical for making informed agricultural policies and investments, as well as increasing market efficiency and stability. In Becker-Reshef et al. (2010) and Franch et al. (2015) we developed an empirical generalized model for forecasting winter wheat yield. In this study we present a new model based on the extrapolation of the pure wheat signal (100 percent of wheat within the pixel) from MODIS (Moderate-resolution Imaging Spectroradiometer) data at 1-kilometer resolution and using the Difference Vegetation Index (DVI). The model has been applied to monitor the national and state level yield of winter wheat in the United States from 2001 to 2016.

Agriculture↗

Ephemerides of the Uranian satellites determined from earth-based astrometric and Voyager imaging observations

Uranian satellite ephemerides were needed by the Voyager project to support both navigation and acquisition of scientific data. This paper outlines the mathematical modeling approach taken to generate those ephemerides and discusses their pre-encounter development, real time updating, and post-encounter refinement. The results presented include the final set of model parameters which generate the ephemerides that best fit the Voyager optical data as well as the earth based observations of the satellites.

Jacobson, R. A.↗

Toward in vivo lung's tissue incompressibility characterization for tumor motion modeling in radiation therapy

Purpose: A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Estimating lung tissue incompressibility parameter variations resulting from air content variation throughout respiration is critical for computer assisted tumor motion tracking. Continuous tumor motion is a major challenge in lung cancer radiotherapy, especially with external beam radiotherapy. If not accounted for, this motion may lead to areas of radiation overdosage for normal tissue. Given the unavailability of imaging modality that can be used effectively for real-time lung tumor tracking, computer assisted approach based on tissue deformation estimation can be a good alternative. This approach involves lung biomechanical model where its fidelity depends on input tissue properties. This investigation shows that considering variable tissue incompressibility parameter is very important for predicting tumor motion accurately, hence improving the lung radiotherapy outcome. Methods: First, an in silico lung phantom study was conducted to demonstrate the importance of employing variable Poisson's ratio for tumor motion predication. After it was established that modeling this variability is critical for accurate tumor motion prediction, an optimization based technique was developed to estimate lung tissue Poisson's ratio as a function of respiration cycle time. In this technique, the Poisson's ratio and lung pressure value were varied systematically until optimal values were obtained, leading to maximum similarity between acquired and simulated 4D CT lung images. This technique was applied in an ex vivo porcine lung study where simulated images were constructed using the end exhale CT image and deformation fields obtained from the lung's FE modeling of each respiration time increment. To model the tissue, linear elastic and Marlow hyperelastic material models in conjunction with variable Poisson's ratio were used. Results: The phantom study showed that the tumor motion trajectory and its final locations obtained from simulations with and without considering tissue incompressibility variation were very different. For example, tumor displacements in the z direction were -11.23 and -38.10 mm obtained with the Marlow hyperelastic material model in conjunction with constant and variable Poisson's ratio, respectively. By comparing the acquired 4D-CT image sequence of the porcine lung with their image sequence counterparts obtained from the hyperelastic model with constant and variable Poisson's ratio, it was shown that using variable tissue incompressibility reduced errors significantly in tumor motion prediction. Conclusions: This investigation demonstrates the importance of incompressibility variation estimation and utilization for accurate tumor tracking in computer assisted lung external beam radiation therapy. An optimization framework was developed to estimate a Poisson's ratio function in terms of respiration cycle time using experimental image data of the lung. Utilizing this function along with respiratory system FE modeling may lead to more effective tumor targeting, hence potentially improving the outcome of lung external beam radiation therapy techniques. This is particularly true for stereotactic body radiation therapy where only one or a few fraction treatments are applied, precluding the possibility of averaging out dosimetric deviations introduced by the respiratory motion.

60 APPLIED LIFE SCIENCES↗

SU-E-J-69: Iterative Deconvolution of the Initial Photon Fluence for EPID Dosimetry: A Monte Carlo Based Study

Purpose: Developing a fast and accurate calculation model to reconstruct the applied photon fluence from an external photon radiation therapy treatment based on an image recorded by an electronic portal image device (EPID). Methods: To reconstruct the initial photon fluence the 2D EPID image was corrected for scatter from the patient/phantom and EPID to generate the transmitted primary photon fluence. This was done by an iterative deconvolution using precalculated point spread functions (PSF). The transmitted primary photon fluence was then backprojected through the patient/phantom geometry considering linear attenuation to receive the initial photon fluence applied for the treatment.The calculation model was verified using Monte Carlo simulations performed with the EGSnrc code system. EPID images were produced by calculating the dose deposition in the EPID from a 6 MV photon beam irradiating a water phantom with air and bone inhomogeneities and the ICRP anthropomorphic voxel phantom. Results: The initial photon fluence was reconstructed using a single PSF and position dependent PSFs which depend on the radiological thickness of the irradiated object. Appling position dependent point spread functions the mean uncertainty of the reconstructed initial photon fluence could be reduced from 1.13 % to 0.13 %. Conclusion: This study presents a calculation model for fluence reconstruction from EPID images. The{sup Result} show a clear advantage when position dependent PSF are used for the iterative reconstruction. The basic work of a reconstruction method was established and further evaluations must be made in an experimental study.

60 APPLIED LIFE SCIENCES↗