An interface for the direct coupling of small liquid samples to AMS

We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14 C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targets for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14 C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.

14C↗

Optical Diagnostics of Discharges in and in Contact With Liquids

Discharges in liquids have been the subject of intensive investigations for a broad range of applications and involve highly coupled and complex phenomena with timescales ranging from picoseconds to seconds and length scales from micrometers to centimeters. This review focuses on some of the challenges in optical diagnostics of discharges in and in contact with liquids; this includes the interpretation of optical emission spectra, the inherently stochastic nature of many discharge phenomena including the initial stages of plasma ignition, and the large gradients in species and plasma properties interfacing with a dynamic liquid interface. We report recent notable advances, controversies in interpretations of diagnostics, and remaining opportunities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of defects and solid/liquid interfacial interactions on controlling anisotropic growth of novel two-dimensional materials

Atomic-scale understanding about how interfacial properties are modified in the presence of defects and how they are correlated to the properties of nucleation and growth is critical for controlled materials growth on solid/liquid interfaces. The goal of this proposal is to establish preliminary data on the critical role of surface defects and chemical compositions of solvent on the structure, dynamics, reactivity, and free energetics at graphene/ionic liquid (IL) interfaces and their impact on two-dimensional (2D) growth of transition metal oxides on the surface. This study aims to develop generalized physical/chemical principles for directional growth at solid/liquid interfaces to achieve atomic-level control of two-dimensional materials synthesis. The proposed study of the effects of surface defects on the interfacial structure and reactivity will improve our understanding of the critical roles of heterogeneity, disorder, and solvents on 2D materials synthesis and lead to better control of directional growth of materials at solid/liquid interfaces.

36 MATERIALS SCIENCE↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

On Pulsating and Cellular Forms of Hydrodynamic Instability in Liquid-Propellant Combustion

An extended Landau-Levich model of liquid-propellant combustion, one that allows for a local dependence of the burning rate on the (gas) pressure at the liquid-gas interface, exhibits not only the classical hydrodynamic cellular instability attributed to Landau but also a pulsating hydrodynamic instability associated with sufficiently negative pressure sensitivities. Exploiting the realistic limit of small values of the gas-to-liquid density ratio p, analytical formulas for both neutral stability boundaries may be obtained by expanding all quantities in appropriate powers of p in each of three distinguished wave-number regimes. In particular, composite analytical expressions are derived for the neutral stability boundaries A(sub p)(k), where A, is the pressure sensitivity of the burning rate and k is the wave number of the disturbance. For the cellular boundary, the results demonstrate explicitly the stabilizing effect of gravity on long-wave disturbances, the stabilizing effect of viscosity (both liquid and gas) and surface tension on short-wave perturbations, and the instability associated with intermediate wave numbers for negative values of A(sub p), which is characteristic of many hydroxylammonium nitrate-based liquid propellants over certain pressure ranges. In contrast, the pulsating hydrodynamic stability boundary is insensitive to gravitational and surface-tension effects but is more sensitive to the effects of liquid viscosity because, for typical nonzero values of the latter, the pulsating boundary decreases to larger negative values of A(sub p) as k increases through O(l) values. Thus, liquid-propellant combustion is predicted to be stable (that is, steady and planar) only for a range of negative pressure sensitivities that lie below the cellular boundary that exists for sufficiently small negative values of A(sub p) and above the pulsating boundary that exists for larger negative values of this parameter.

Margolis, Stephen B.↗

An optical method for determining level in two-phase cryogenic fluids

A method was evaluated to measure the liquid-gas and the liquid-slush interfaces in two-phase cryogen systems using optical means. This method makes use of the attenuation of a directed light beam caused by the difference in the index of refraction between the solid particles and the surrounding liquid. Preliminary experimental results obtained in slush nitrogen are shown. The possibility of extending this technique to include a measure of solid fraction is also discussed.

Oberle, Lawrence G.↗

Review of nucleation and incipient boiling under pool and forced convection conditions

An overview of liquid-vapor nucleation is given. The result of thermodynamic equilibrium across curved liquid-vapor interfaces is presented. The extension of this to include the interaction with idealizations of surface cavities is made to demonstrate how superheat requirements for nucleation will be affected by surface roughness, flow velocity and buoyancy. Experimental measurements of high liquid superheats and nucleation delay times are presented as examples of homogeneous nucleation. Examples of nucleation and boiling on smooth glass substrates and on metal surfaces with various surface roughnesses are presented.

Merte, Herman, Jr.↗

Instabilities of Shallow Dynamic Thermocapillary Liquid Layers

In the experiments reported here, correlation measurements with three fixed thermocouples and direct optical observations of the dynamically deformed liquid-gas interface were used to study the spatiotemporal structure of stable and unstable thermocapillary flows. The frequency, wavelength, phase speed, angle of propagation, and stability limits are reported for two geometrically different configurations of thermocapillary flow in side-heated thin liquid layers. A theoretical interpretation of the results is presented.

Schwabe, D.↗

Seeing through walls at the nanoscale: Microwave microscopy of enclosed objects and processes in liquids

Here, noninvasive in situ nanoscale imaging in liquid environments is a current imperative in the analysis of delicate biomedical objects and electrochemical processes at reactive liquid–solid interfaces. Microwaves of a few gigahertz frequencies offer photons with energies of ≈10 μeV, which can affect neither electronic states nor chemical bonds in condensed matter. Here, we describe an implementation of scanning near-field microwave microscopy for imaging in liquids using ultrathin molecular impermeable membranes separating scanning probes from samples enclosed in environmental cells. We imaged a model electroplating reaction as well as individual live cells. Through a side-by-side comparison of the microwave imaging with scanning electron microscopy, we demonstrate the advantage of microwaves for artifact-free imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Parallel Grand Canonical Monte Carlo (ParaGrandMC) Simulation Code

This report provides an overview of the Parallel Grand Canonical Monte Carlo (ParaGrandMC) simulation code. This is a highly scalable parallel FORTRAN code for simulating the thermodynamic evolution of metal alloy systems at the atomic level, and predicting the thermodynamic state, phase diagram, chemical composition and mechanical properties. The code is designed to simulate multi-component alloy systems, predict solid-state phase transformations such as austenite-martensite transformations, precipitate formation, recrystallization, capillary effects at interfaces, surface absorption, etc., which can aid the design of novel metallic alloys. While the software is mainly tailored for modeling metal alloys, it can also be used for other types of solid-state systems, and to some degree for liquid or gaseous systems, including multiphase systems forming solid-liquid-gas interfaces.

Vesselin I Yamakov↗

Parallel Grand-Canonical Monte Carlo (ParaGrandMC) User’s Manual Version 2.0

This manual describes the commands and command line options for the Parallel Grand Canonical Monte Carlo version 2.0 (ParaGrandMC.2.0) simulation code. This is a highly scalable parallel FORTRAN 2003 code for simulating the thermodynamic evolution of materials at the atomic level, and predicting their thermodynamic state, phase diagram, chemical composition and mechanical properties. The code is specifically designed to simulate multi-component alloy systems, predict solid-state phase transformations such as austenite-martensite transformations, precipitate formation, recrystallization, capillary effects at interfaces, surface absorption, etc., which can aid the design of novel metallic alloys. While the software is mainly tailored for modeling metal alloys, it can also be used for other types of solid-state systems, and to some degree for liquid or gaseous systems, including multiphase systems forming solid-liquid-gas interfaces. In addition to performing Monte Carlo (MC) simulations, the code can also perform Molecular Dynamics (MD) and Langevin Dynamics (LD) simulations, which can be combined and interchanged with MC for faster and more efficient system evolution. A detailed description of the MC part of the code is provided in the NASA ParaGrandMC report: NASA/CR–2016-219202; http://www.sti.nasa.gov.

High performance computing↗

Mixing-induced fluid destratification and ullage condensation

In many applications, on-orbit storage and transfer of cryogens will require forced mixing to control tank pressure without direct venting to space. During a no-vent transfer or during operation of a thermodynamic vent system in a cryogen storage tank, pressure control is achieved by circulating cool liquid to the liquid-vapor interface to condense some of the ullage vapor. To measure the pressure and temperature response rates in mixing-induced condensation, an experiment has been developed using Freon 11 to simulate the two-phase behavior of a cryogen. A thin layer at the liquid surface is heated to raise the tank pressure, and then a jet mixer is turned on to circulate the liquid, cool the surface, and reduce the pressure. Many nozzle configurations and flow rates are used. Tank pressure and the temperature profiles in the ullage and the liquid are measured. Initial data from this ground test are shown correlated with normal-gravity and drop-tower dye-mixing data. Pressure collapse times are comparable to the dye-mixing times, whereas the times needed for complete thermal mixing are much longer than the dye-mixing times.

Meserole, Jere S.↗

Effect of baffle on the asymmetric gravity jitter excited slosh waves in microgravity

The paper investigates the dynamical behavior of fluids affected by asymmetric gravity jitter oscillations, in particular, the effect of surface tension on partially filled rotating fluids in a full-scale Gravity Probe-B Spacecraft dewar tank, with and without the installation of the baffle-board, imposed by time-dependent directions of background gravity. The time-sequence evolution of the 3D behavior of the liquid-vapor interface oscillations resulting in the excitation of large amplitude slosh waves exerted by gravity jitter disturbances are examined. It is shown that the damping effect provided by baffle reduces the amplitude of slosh wave excitation and lowers the degree of asymmetry in the liquid-vapor distribution.

Hung, R. J.↗

Iodination of PEGylated Polymers Counteracts the Inhibition of Fibrinogen Adsorption by PEG

Poly(ethylene glycol), PEG, known to inhibit protein adsorption, is widely used on the surfaces of biomedical devices when biofilm formation is undesirable. Poly(desaminotyrosyl-tyrosine ethyl ester carbonate), PDTEC, PC for short, has been a promising coating polymer for insertion devices, and it has been anticipated that PEG plays a similar role if it is copolymerized with PC. Earlier studies show that no fibrinogen (Fg) is adsorbed onto PC polymers with PEG beyond the threshold weight percentage. This is attributed to the phase separation of PEG. Further, iodination of the PC units in the PC polymer, (I 2 PC), has been found to counteract this Fg-repulsive effect by PEG. Here, in this study, we employ surface-sensitive X-ray techniques to demonstrate the surface affinity of Fg toward the air–water interface, particularly in the presence of self-assembled PC-based film, in which its constituent polymer units are assumed to be much more mobile as a free-standing film. Fg is found to form a Gibbs monolayer with its long axis parallel to the aqueous surface, thus maximizing its interactions with hydrophobic interfaces. It influences the amount of insoluble, surface-bound I 2 PC likely due to the desorption of the formed Fg–I 2 PC complex and/or the penetration of Fg onto the I 2 PC film. The results show that the phase behavior at the liquid–polymer interface shall be taken into account for the surface behavior of bulk polymers surrounded by tissue. The ability of PEG units rearranging into a protein-blocking layer, rather than its mere presence in the polymer, is the key to antifouling characteristics desired for polymeric coating on insertion devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined soft and hard X-ray ambient pressure photoelectron spectroscopy studies of semiconductor/electrolyte interfaces

The development of solar fuel generating materials would greatly benefit from a molecular level understanding of the semiconductor/electrolyte interface and changes in the interface induced by an applied potential and illumination by solar light. Ambient pressure photoelectron spectroscopy techniques with both soft and hard X-rays, AP-XPS and AP-HAXPES respectively, have the potential to markedly contribute to this understanding. In this paper we initially provide two examples of current challenges in solar fuels material development that AP-XPS and AP-HAXPES can directly a ddress. This will be followed by a brief description of the distinguishing and complementary characteristics of soft and hard X-ray AP-XPS and AP-HAXPES and best approaches to achieving monolayer sensitivity in solid/aqueous electrolyte studies. In particular we focus on the detection of surface adsorbed hydroxyl groups in the presence of aqueous hydroxide anions in the electrolyte, a common situation when investigating photoanodes for solar fuel generating applications. Finally, the article concludes by providing an example of a combined AP-XPS and AP-HAXPES study of a semiconductor/aqueous electrolyte interface currently used in water splitting devices specifically the BiVO 4 /aqueous potassium phosphate electrolyte interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opportunities and new developments for the study of surfaces and interfaces in soft condensed matter at the SIRIUS beamline of Synchrotron SOLEIL

The SIRIUS beamline of Synchrotron SOLEIL is dedicated to X-ray scattering and spectroscopy of surfaces and interfaces, covering the tender to mid-hard X-ray range (1.1–13 keV). The beamline has hosted a wide range of experiments in the field of soft interfaces and beyond, providing various grazing-incidence techniques such as diffraction and wide-angle scattering (GIXD/GIWAXS), small-angle scattering (GISAXS) and X-ray fluorescence in total reflection (TXRF). SIRIUS also offers specific sample environments tailored for in situ complementary experiments on solid and liquid surfaces. Recently, the beamline has added compound refractive lenses associated with a transfocator, allowing for the X-ray beam to be focused down to 10 µm × 10 µm while maintaining a reasonable flux on the sample. This new feature opens up new possibilities for faster GIXD measurements at the liquid–air interface and for measurements on samples with narrow geometries.