Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Effects of Granular Control on Customers’ Perspective and Behavior with Automated Demand Response Systems

Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.

Schetrit, Oren↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dry Sliding Behavior of a TiZr-Based Alloy under Air and Vacuum Conditions

In this study, dry sliding tribological properties of a TiZr-based alloy with the chemical composition Ti-20Zr-6.5Al-4V (wt.%) were tested in air and vacuum under different normal loads (10, 20, and 30 N) at various sliding velocities. Results showed that the coefficient of friction in air was lower than that in vacuum, whereas the wear volume at sliding velocity presented an opposite trend. The surfaces and cross-sectional morphology of wear scar on the TiZrAlV alloy was analyzed through scanning electron microscopy to determine the wear mechanisms. The observations showed that abrasive wear and delamination wear were dominant in air. In vacuum, the main wear mechanism changed from slightly abrasive and adhesive wear to severe adhesive wear and delamination wear as the normal load increased. Wear mechanism maps were also constructed and compared. The comparison showed that severe wear (including delamination wear) was prevalent in air.

36 MATERIALS SCIENCE↗

Experimental Demonstration of Wakefield Acceleration in a Tunable Dielectric Loaded Accelerating Structure

We report on a collinear wakefield experiment using the first tunable dielectric loaded accelerating structure. By introducing an extra layer of nonlinear ferroelectric, which has a dielectric constant sensitive to temperature and dc bias, the frequency of a dielectric loaded accelerating structure can be tuned. During the experiment, the energy of a witness bunch at a fixed delay with respect to the drive beam was measured while the temperature of the structure was scanned over a 50 deg. C range. The energy change corresponded to a change of more than half of the nominal structure wavelength.

43 PARTICLE ACCELERATORS↗

EM structure of a helicase-loader complex depicting a 6:2 binding sub-stoichiometry from Geobacillus kaustophilus HTA426

During DNA replication, bacterial helicase is recruited as a complex in association with loader proteins to unwind the parental duplex. Previous structural studies have reported saturated 6:6 helicase-loader complexes with different conformations. However, structural information on the sub-stoichiometric conformations of these previously-documented helicase-loader complexes remains elusive. Here, with the aid of single particle electron-microscopy (EM) image reconstruction, we present the Geobacillus kaustophilus HTA426 helicase-loader (DnaC-DnaI) complex with a 6:2 binding stoichiometry in the presence of ATPγS. In the 19 Å resolution EM map, the undistorted and unopened helicase ring holds a robust loader density above the C-terminal RecA-like domain. Meanwhile, the path of the central DNA binding channel appears to be obstructed by the reconstructed loader density, implying its potential role as a checkpoint conformation to prevent the loading of immature complex onto DNA. Our data also reveals that the bound nucleotides and the consequently induced conformational changes in the helicase hexamer are essential for active association with loader proteins. These observations provide fundamental insights into the formation of the helicase-loader complex in bacteria that regulates the DNA replication process. - Highlights: • Helicase-loader complex structure with 6:2 sub-stoichiometry is resolved by EM. • Helicase hexamer in 6:2 sub-stoichiometry is constricted and un-opened. • 6:2 binding ratio of helicase-loader complex could act as a DNA loading checkpoint. • Nucleotides stabilize helicase-loader complex at low protein concentrations.

60 APPLIED LIFE SCIENCES↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Climate-Induced Tradeoffs in Planning and Operating Costs of a Regional Electricity System

Electricity grid planners design the system in order to supply electricity to end users reliably and affordably. Climate change threatens both objectives through potentially compounding supply- and demand-side climate-induced impacts. Uncertainty surrounds each of these future potential impacts. Given long planning horizons, system planners must weigh investment costs against operational costs under this uncertainty. Here, we developed a comprehensive and coherent integrated modeling framework combining physically-based models with cost-minimizing optimization models in the power system. We applied this modeling framework to analyze potential tradeoffs in planning and operating costs in the power grid due to climate change in the Southeast U.S. in 2050. We find that planning decisions that do not account for climate-induced impacts would result in a substantial increase in social costs associated with loss of load. These social costs are a result of under-investment in new capacity and capacity deratings of thermal generators when we included climate change impacts in the operation stage. Finally, these results highlight the importance of including climate change effects in the planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination of deformations as a result of seismic loadings on two-dimensional reinforced concrete frame via terrestrial laser scanners

Parallel to the technological developments, methods of defining locational data are changing. Laser scanners bring new advantages to engineering measurements and geodesy. Terrestrial laser scanners, which have previously been used in map engineering, have become an alternative method of measurement, especially for terrestrial applications. A common characteristic of deformation measurements is the requirement to measure the location of sufficient reference and object points established on the monitored structure. The number of reference and object points is limited when using classical methods, but not when using a laser scanner. Due to the limitations of classical geodetic survey methods, such as difficulty of application, high costs and low production speed, the present study applied ground laser scanners to deformation monitoring. A two-dimensional (2D) deformation survey was made of a concrete frame placed on a loading wall. Cartesian coordinates, derived from survey and evaluations, were converted into a standard coordinate system using the Molodensky–Badekas 3D similarity transformation. Student’s t test has been used to determine whether it was significant with the difference of coordinates or not. The deformation amounts and directions obtained from the electronic tachymeter and ground laser scanners were found to be very similar.

42 ENGINEERING↗

Effect of occupant behavior and air-conditioner controls on humidity in typical and high-efficiency homes

Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity, and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IMPLEMENTING PRIMARY CREEP CALCULATIONS DURING STRESS CHANGES AND REVERSALS IN THE FUEL PERFORMANCE CODE FRAPCON-3

Recently, the creep models in FRAPCON-3.4 were used to model the creep tests performed in IFA-699 up through cycle 4. IFA-699 is an instrumented test rig in the Halden Boiling Water Reactor that is being used to perform in-reactor creep experiments under changing stress conditions. The cladding creep tests in IFA-699 were on four fresh fuel segments with Zircaloy-4, E110, M-MDA, and M5™ cladding. These fuel segments were loaded in a test rig and placed in a PWR loop and operated under PWR conditions. Each of the test fuel rods were connected to gas lines in order to apply tensile and compressive stresses to the cladding. Diameters of the cladding were measured by diameter gages at several intervals to measure the creep behavior of the cladding as a function of time. The creep tests were performed at a temperature of around 360°C and fast neutron flux of 1.8 to 2.4×1017 n/m²-s (depends on specimen location). During the four cycles of operation, hoop stresses of -75, -50, +30, and +110 MPa were applied to the specimens. In addition to providing assessment of the FRAPCON-3.4 creep modeling, the creep model comparisons were also used to provide insight into the nature of primary creep following stress changes, whether creep behavior is symmetric under tensile and compressive loading, and the effect of fast fluence on creep rate. It was determined that creep strain should be calculated as a function of effective stress rather than hoop stress. This accounts for the observed difference between creep under compressive and tensile stress for the same hoop stress. It was also determined that the primary creep changes in proportion to the change in stress following stress change or stress reversal. Finally, it was observed that the irradiation creep rate decreases somewhat with increasing fluence. The creep model in FRAPCON-3.4 has already been developed to be a function of effective stress and includes a term that decreases the irradiation creep rate with increasing fluence. A new mathematical formulation has been developed that is suitable for a fuel performance code to calculate the primary creep strain under conditions of changing stress and stress reversal. The creep model in FRAPCON-3.4 and the formulation for calculating primary creep under changing stress conditions will be described in this paper. Comparisons to data will also be provided.

Geelhood, Kenneth J.↗

SINGLE-SHELL TANK INTEGRITY PROJECT ANALYSIS OF RECORD-PRELIMINARY MODELING PLAN FOR THERMAL AND OPERATING LOADS

This document is a Phase I deliverable for the Single-Shell Tank Analysis of Record effort. This document is not the Analysis of Record. The intent of this document is to guide the Phase II detailed modeling effort. Preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. The preliminary analysis document reviews and preliminary modeling analysis results are reported herein. In addition, this report provides recommendations for the next phase of the SST AOR project, SST detailed modeling. Efforts and results discussed in this report do not include seismic modeling as seismic modeling is covered by a separate report. The combined results of both static and seismic models are required to complete this effort. The SST AOR project supports the US Department of Energy's (DOE) Office of River Protection (ORP) mission for obtaining a better understanding of the structural integrity of Hanford's SSTs. The 149 SSTs, with six different geometries, have experienced a range of operating histories which would require a large number of unique analyses to fully characterize their individual structural integrity. Preliminary modeling evaluations were conducted to determine the number of analyses required for adequate bounding of each of the SST tank types in the Detailed Modeling Phase of the SST AOR Project. The preliminary modeling was conducted in conjunction with the Evaluation Criteria report, Johnson et al. (2010). Reviews of existing documents were conducted at the initial stage of preliminary modeling. These reviews guided the topics that were explored in the SST preliminary modeling. The reviews determined the level of detail necessary to perform the analyses of the SSTs. To guide the Phase II detailed modeling effort, preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. Conclusions were derived from case studies on one of the tank types when no additional runs of similar cases on other types of tanks were found necessary to derive those conclusions. The document reviews provided relatively complete temperature histories for Type IV tanks. The temperature history data for Type I, II, and III tanks was almost nonexistent for years prior to 1975. Document reviews indicate that there might be additional useful data in the US Department of Energy, Richland Operations Office (DOE-RL) records in Seattle, WA, and these records need to be reviewed to extract data that might have been disregarded during previous reviews. Thermal stress analyses were conducted using different temperature distribution scenarios on Type IV tanks. Such studies could not be carried out for other tank types due to lack of temperature history data. The results from Type IV tank analyses indicate that factors such as temperature distribution in the tank waste and rate of rise in waste temperature have a significant impact on the thermal stresses in the tank structures. Overall, the conclusion that can drawn from the thermal stress analyses is that these studies should be carried out for all tank types during the detailed analysis phase with temperature values that are reasonably close to the typical temperature histories of the respective tank types. If and/or when additional waste temperature data is acquired for tank Type I, II, and III tanks, additional cases need to be considered as tank structural integrity is sensitive to thermal loads. A few case studies were also performed using Type IV-b models to comprehend the effects of excavation boundaries, change in soil stratigraphy (layer thickness and properties), and radial extent of soil in the finite element models. The result from the case studies indicates that the slight variation in soil stratigraphy has little effects on the tank sections force and moment demands under mechanical loads. The case study for excavation slope or backfill transition boundary indicated that inclusion of such boundary yields conservative demands in the wall region while demands at other locations remain unaffected. Hence this excavation slope will be modeled in the detailed analysis of SSTs.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fiber from DDGS and Corn Grain as Alternative Fillers in Polymer Composites with High Density Polyethylene from Bio-based and Petroleum Sources

The steady increase in production of corn based ethanol fuel has dramatically increased the supply of its major co-product known as distiller’s dried grain with solubles (DDGS). Large amount of DDGS and corn flour are used as an animal feed. The elusieve process can separate DDGS or corn flour into two fractions: DDGS fraction with enhanced protein and oil content or corn flour fraction with high starch content, and hull fiber. This study investigated the feasibility of using fiber from DDGS and corn grain as alternative fillers to wood fiber in high density polyethylene (HDPE) composites made with two different sources of polymers. Two fiber loading rates of 30 and 50% were evaluated for fiber from DDGS, corn, and oak wood (control) to assess changes in various physical and mechanical properties of the composite materials. Two HDPE polymers, a bio-based HDPE made from sugarcane (Braskem), and a petroleum based HDPE (Marlex) were also compared as substrates. The biobased polymer composites with DDGS and corn fibers showed significantly lower water absorption than the Marlex composite samples. The Braskem composite with 30% DDGS fiber loading showed the highest impact resistance (80 J/m) among all the samples. The flexural properties showed no significant difference between the two HDPE composites.

36 MATERIALS SCIENCE↗

OC6 phase I: Improvements to the OpenFAST predictions of nonlinear, low-frequency responses of a floating offshore wind turbine platform

We report in the OC5 and OC6 projects, the authors observed a persistent underprediction of the nonlinear, low-frequency responses of an offshore wind semisubmersible with many mid-fidelity engineering models, including the OpenFAST tool developed by the National Renewable Energy Laboratory. Both the low-frequency wave excitation in surge and pitch and the resulting resonance motions were severely underpredicted. In response, we developed several modifications to the OpenFAST model from the OC5/6 projects to improve the predictions of the low-frequency wave loads and responses. All modifications are in the modeling of the viscous drag forces. Efforts were made to provide physical justifications to the changes and to limit the number of additional parameters requiring tuning, so that the modified model can be applied to other floating wind systems. With the proposed modifications, the predictions of the low-frequency surge and pitch wave loads on a fixed floater and the resonance responses of a floating structure are both significantly improved with a single set of model coefficients, which leads to good agreement with the measurements from the OC6 wave-basin experimental campaign.

17 WIND ENERGY↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Dynamic response of phenolic resin and its carbon-nanotube composites to shock wave loading

We investigate with nonreactive molecular dynamics simulations the dynamic response of phenolic resin and its carbon-nanotube (CNT) composites to shock wave compression. For phenolic resin, our simulations yield shock states in agreement with experiments on similar polymers except the “phase change” observed in experiments, indicating that such phase change is chemical in nature. The elastic–plastic transition is characterized by shear stress relaxation and atomic-level slip, and phenolic resin shows strong strain hardening. Shock loading of the CNT-resin composites is applied parallel or perpendicular to the CNT axis, and the composites demonstrate anisotropy in wave propagation, yield and CNT deformation. The CNTs induce stress concentrations in the composites and may increase the yield strength. Our simulations indicate that the bulk shock response of the composites depends on the volume fraction, length ratio, impact cross-section, and geometry of the CNT components; the short CNTs in current simulations have insignificant effect on the bulk response of resin polymer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Residual-stress-induced grain growth of twinned grains and its effect on formability of magnesium alloy sheet at room temperature

A magnesium alloy sheet was subjected to in-plane compression along with a vertical load to avoid buckling during compression. Pre-compressed specimens machined from the sheet were annealed at different temperatures and the changes in microstructure and texture were observed using electron back scattered diffraction (EBSD). Twinned grains preferentially grew during annealing at 300 °C, so that a strong texture with the < 0001 > direction parallel to the transverse direction developed. EBSD analysis confirmed that the friction caused by the vertical load induced inhomogeneous distribution of residual stress, which acted as an additional driving force for preferential grain growth of twinned grain during annealing. The annealed specimen showed excellent formability. - Highlights: • A magnesium alloy sheet subjected to in-plane compression under a vertical load • The vertical load induced inhomogeneous distribution of the residual stress. • The residual stress acted as an additional driving force for grain growth. • The annealed specimen with strong non-basal texture showed excellent formability.

36 MATERIALS SCIENCE↗