At least 1,225 records · Page 68

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of bit-error rate

Error rate of RF digital communication link is measured at low signal-to-noise ratios using this technique. In this method, identical pseudo-random sequences of pulses are generated at transmitter and receiver of link. However, comparison of two sequences at receiver involves integration that makes bit-tracking threshold depend on length of pseudo-random sequence, rather than on actual rate of transmission of individual bits.

Fowler, J.↗

Direct Writing of X-ray Gratings Using Zone-Plate-Array Lithography (ZPAL)

With the objective of providing the synchrotron and free-electron-laser communities with rapid turnaround and low prices for the highest quality and most advanced gratings and diffractive-focusing optics, LumArray has made specific improvements to its ZP-150 maskless photolithography system, which is based on Zone-Plate-Array Lithography (ZPAL), a technology unique to Lumarray. ZPAL’s advantages include an ability to correct in software for systematic patterning errors. Emphasis was placed on interferometric measurements of various contributors to patterning errors using Fizeau interferometry and a Mireau technique that was developed specifically for measuring errors within a micron-scale area. Average line-placement error was reduced below 20 nm using both pattern-file distortion and address-grid modification. The preferred implementation, address-grid modification, is hardware-based and requires no user intervention while also correcting more types of error. With continued iteration and refinement of the error measurements, we anticipate achieving global line-placement error below10nm. In order to investigate line-edge smoothness and high-frequency line-placement errors, a scheme for inspecting micron-sized areas was invented and implemented based on Mireau interferometry. This enabled the various contributions to be separately evaluated and measured. These included: exposure-dose variation, pattern-writing strategy and errors in the positioning of the microlenses. Deleterious crosstalk between microlenses was minimized via a pattern-dependent software modification. The impact of exposure threshold was revealed and adjustment made. The impact of address-grid fineness on line-edge roughness was likewise shown. Lastly, techniques were developed to measure and correct errors in the positioning of microlenses within the array. We expect final calibration of microlens positions to within 5nm.

42 ENGINEERING↗

Measuring galaxy cluster masses with CMB lensing using a Maximum Likelihood estimator: statistical and systematic error budgets for future experiments

We develop a Maximum Likelihood estimator (MLE) to measure the masses of galaxy clusters through the impact of gravitational lensing on the temperature and polarization anisotropies of the cosmic microwave background (CMB). We show that, at low noise levels in temperature, this optimal estimator outperforms the standard quadratic estimator by a factor of two. For polarization, we show that the Stokes Q/U maps can be used instead of the traditional E- and B-mode maps without losing information. We test and quantify the bias in the recovered lensing mass for a comprehensive list of potential systematic errors. Using realistic simulations, we examine the cluster mass uncertainties from CMB-cluster lensing as a function of an experiment’s beam size and noise level. We predict the cluster mass uncertainties will be 3 - 6% for SPT-3G, AdvACT, and Simons Array experiments with 10,000 clusters and less than 1% for the CMB-S4 experiment with a sample containing 100,000 clusters. The mass constraints from CMB polarization are very sensitive to the experimental beam size and map noise level: for a factor of three reduction in either the beam size or noise level, the lensing signal-to-noise improves by roughly a factor of two.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of vibration induced error in turbulence velocity measurements from an aircraft wing tip boom

The effect of rolling motion of a wing on the magnitude of error induced due to the wing vibration when measuring atmospheric turbulence with a wind probe mounted on the wing tip was investigated. The wing considered had characteristics similar to that of a B-57 Cambera aircraft, and Von Karman's cross spectrum function was used to estimate the cross-correlation of atmospheric turbulence. Although the error calculated was found to be less than that calculated when only elastic bendings and vertical motions of the wing are considered, it is still relatively large in the frequency's range close to the natural frequencies of the wing. Therefore, it is concluded that accelerometers mounted on the wing tip are needed to correct for this error, or the atmospheric velocity data must be appropriately filtered.

Akkari, S. H.↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Measurements and Model Improvement: Insight into NWP Model Error Using Doppler Lidar and Other WFIP2 Measurement Systems

Abstract Doppler-lidar wind-profile measurements at three sites were used to evaluate NWP model errors from two versions of NOAA’s 3-km-grid HRRR model, to see whether updates in the latest version 4 reduced errors when compared against the original version 1. Nested (750-m grid) versions of each were also tested to see how grid spacing affected forecast skill. The measurements were part of the field phase of the Second Wind Forecasting Improvement Project (WFIP2), an 18-month deployment into central Oregon–Washington, a major wind-energy-producing region. This study focuses on errors in simulating marine intrusions, a summertime, 600–800-m-deep, regional sea-breeze flow found to generate large errors. HRRR errors proved to be complex and site dependent. The most prominent error resulted from a premature drop in modeled marine-intrusion wind speeds after local midnight, when lidar-measured winds of greater than 8 m s −1 persisted through the next morning. These large negative errors were offset at low levels by positive errors due to excessive mixing, complicating the interpretation of model “improvement,” such that the updates to the full-scale versions produced mixed results, sometimes enhancing but sometimes degrading model skill. Nesting consistently improved model performance, with version 1’s nest producing the smallest errors overall. HRRR’s ability to represent the stages of sea-breeze forcing was evaluated using radiation budget, surface-energy balance, and near-surface temperature measurements available during WFIP2. The significant site-to-site differences in model error and the complex nature of these errors mean that field-measurement campaigns having dense arrays of profiling sensors are necessary to properly diagnose and characterize model errors, as part of a systematic approach to NWP model improvement. Significance Statement Dramatic increases in NWP model skill will be required over the coming decades. This paper describes the role of major deployments of accurate profiling sensors in achieving that goal and presents an example from the Second Wind Forecast Improvement Program (WFIP2). Wind-profile data from scanning Doppler lidars were used to evaluate two versions of HRRR, the original and an updated version, and nested versions of each. This study focuses on the ability of updated HRRR versions to improve upon predicting a regional sea-breeze flow, which was found to generate large errors by the original HRRR. Updates to the full-scale HRRR versions produced mixed results, but the finer-mesh versions consistently reduced model errors.

Meteorology & Atmospheric Sciences↗

Neutron multiplication error in TRU waste measurements

Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Volumetric apparatus for hydrogen adsorption and diffusion measurements: Sources of systematic error and impact of their experimental resolutions

The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic testing of the Kearfott 2401 accelerometer

A Kearfott pendulous accelerometer was integrated with a United Aircraft pulse torque servo assembly (PTSA) forced binary loop. The test objective was to measure dynamic errors due to anisoinertia and OA coupling effects. The instrument and its torque loop are described, and the technique for isolating the anisoinertia error from centripetal acceleration effects is discussed in detail. The measured anisoinertia error coefficient was 3.0 cm, and the testing confirmed that no rectified OA coupling error was present.

Katz, B.↗

A Novel Method for Phasor Measurement Unit Sampling Time Error Compensation

This paper focuses on a novel method for successive approximation register analog to digital converter control in synchronized phasor measurement units (PMUs). To compensate for the sampling time error caused by the division remainder between the desirable sampling rate and the oscillator frequency, a variable sampling interval control method is presented by interlacing two integers under a proposed criterion. The frequency of the onboard oscillator is monitored in real-time using the pulse per second (PPS) timing reference from global positioning system. The sampling control is adaptively adjusted each second according to the latest estimated oscillator frequency. The “saw tooth” in phasor angle error and DC offset and spikes in frequency error can be effectively eliminated by applying the proposed method. The simulation and experiment results validate the effectiveness and accuracy of the proposed method, which is believed to be able to greatly improve the performance of PPS-disciplined synchronous sampling methods in PMUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploiting Measurement Uncertainty Estimation in Evaluation of GOES-R ABI Image Navigation Accuracy Using Image Registration Techniques

In evaluating GOES-R Advanced Baseline Imager (ABI) image navigation quality, upsampled sub-images of ABI images are translated against downsampled Landsat 8 images of localized, high contrast earth scenes to determine the translations in the East-West and North-South directions that provide maximum correlation. The native Landsat resolution is much finer than that of ABI, and Landsat navigation accuracy is much better than ABI required navigation accuracy and expected performance. Therefore, Landsat images are considered to provide ground truth for comparison with ABI images, and the translations of ABI sub-images that produce maximum correlation with Landsat localized images are interpreted as ABI navigation errors. The measured local navigation errors from registration of numerous sub-images with the Landsat images are averaged to provide a statistically reliable measurement of the overall navigation error of the ABI image. The dispersion of the local navigation errors is also of great interest, since ABI navigation requirements are specified as bounds on the 99.73rd percentile of the magnitudes of per pixel navigation errors. However, the measurement uncertainty inherent in the use of image registration techniques tends to broaden the dispersion in measured local navigation errors, masking the true navigation performance of the ABI system. We have devised a novel and simple method for estimating the magnitude of the measurement uncertainty in registration error for any pair of images of the same earth scene. We use these measurement uncertainty estimates to filter out the higher quality measurements of local navigation error for inclusion in statistics. In so doing, we substantially reduce the dispersion in measured local navigation errors, thereby better approximating the true navigation performance of the ABI system.

navigation performance↗

Measuring Pixel-Position Errors On CCD Imagers

Deviations of positions of pixels on charge-coupled-device (CCD) image detector from nominal rectangular grid pattern measured by method in which coherent-light interference fringes used as reference pattern. Conceived for use in determining pixel-position errors in astrometric cameras flown aboard spacecraft. Also applied to determination of similar errors in (and calibration of) terrestrial CCD cameras used as position sensors; for example, position-measuring cameras that are parts of robotic systems.

Shaklan, Stuart B.↗

Comparison of Transmission Error Predictions with Noise Measurements for Several Spur and Helical Gears

Measured sound power data from eight different spur, single and double helical gear designs are compared with predictions of transmission error by the Load Distribution Program. The sound power data was taken from the recent Army-funded Advanced Rotorcraft Transmission project. Tests were conducted in the NASA gear noise rig. Results of both test data and transmission error predictions are made for each harmonic of mesh frequency at several operating conditions. In general, the transmission error predictions compare favorably with the measured noise levels.

Houser, Donald R.↗