Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

DESIGN OF A THIRD HARMONIC CAVITY WITH LOW R/Q FOR THE ESR IN BNL EIC

For the electron Storage Ring (ESR) of Brookhaven Na-tional Lab Electron Ion Collider (BNL EIC), beam loading is a great concern due to the high beam current together with abortion gap, especially for harmonic cavities due to higher operational frequency. There were attempts to use feedback/feedforward control, using multiple cavities with counter-phasing [1]. A straightforward way to lower beam loading effect is to design a cavity with low R/Q. In this paper, we show such a design for the 3rd harmonic cavity for BNL EIC ESR.

43 PARTICLE ACCELERATORS↗

HOM DAMPER DESIGN FOR BNL EIC 197MHZ CRAB CAVITY

For the electron Storage Ring (ESR) of Brookhaven Na-tional Lab Electron Ion Collider (BNL EIC), beam loading is a great concern due to the high beam current together with abortion gap, especially for harmonic cavities due to higher operational frequency. There were attempts to use feedback/feedforward control, using multiple cavities with counter-phasing [1]. A straightforward way to lower beam loading effect is to design a cavity with low R/Q. In this paper, we show such a design for the 3rd harmonic cavity for BNL EIC ESR.

43 PARTICLE ACCELERATORS↗

Analysis of Graphite Reinforced Cementitious Composites

This paper describes analytical methods that can be used to determine the deflections and stresses in highly compliant graphite-reinforced cementitious composites. It is demonstrated that the standard transform section fails to provide accurate results when the elastic modulus ratio exceeds 20. So an alternate approach is formulated by using the rule of mixtures to determine a set of effective material properties for the composite. Tensile tests are conducted on composite samples to verify this approach; and, when the effective material properties are used to characterize the deflections of composite beams subject to pure bending, an excellent agreement is obtained. Laminated composite plate theory is also investigated as a means for analyzing even more complex composites, consisting of multiple graphite layers oriented in different directions. In this case, composite beams are analyzed by incorporating material properties established from tensile tests. Finite element modeling is used to verity the results and, considering the complexity of the samples, a very good agreement is obtained.

Vaughan, Robert E.↗

TH-CD-207B-01: BEST IN PHYSICS (IMAGING): Development of High Brightness Multiple-Pixel X-Ray Source Using Oxide Coated Cathodes

Purpose: To develop and characterize a high brightness multiple-pixel thermionic emission x-ray (MPTEX) source. Methods: Multiple-pixel x-ray sources allow for designs of novel x-ray imaging techniques, such as fixed gantry CT, digital tomosynthesis, tetrahedron beam computed tomography, etc. We are developing a high-brightness multiple-pixel thermionic emission x-ray (MPTEX) source based on oxide coated cathodes. Oxide cathode is chosen as the electron source due to its high emission current density and low operating temperature. A MPTEX prototype has been developed which may contain up to 41 micro-rectangular oxide cathodes in 4 mm pixel spacing. Electronics hardware was developed for source control and switching. The cathode emission current was evaluated and x-ray measurements were performed to estimate the focal spot size. Results: The oxide cathodes were able to produce ∼110 mA cathode current in pulse mode which corresponds to an emission current density of 0.55 A/cm{sup 2}. The maximum kVp of the MPTEX prototype currently is limited to 100 kV due to the rating of high voltage feedthrough. Preliminary x-ray measurements estimated the focal spot size as 1.5 × 1.3 mm{sup 2}. Conclusion: A MPTEX source was developed with thermionic oxide coated cathodes and preliminary source characterization was successfully performed. The MPTEX source is able to produce an array of high brightness x-ray beams with a fast switching speed.

60 APPLIED LIFE SCIENCES↗

Doubling Beam Intensity Unlocks Rare Opportunities for Discovery at Fermi National Accelerator Laboratory

Particle accelerators such as the Booster synchrotron at the Fermi National Accelerator Laboratory (FNAL) produce high-intensity proton beams for particle physics experiments that can ultimately reveal the secrets of the universe. High-intensity proton beams are required by experiments at the “intensity frontier” of particle physics research, where the availability of more particles improves the chances of observing extremely rare physical processes. In addition to their central role in particle physics experiments, particle accelerators have found widespread use in industrial, nuclear, environmental, and medical applications. RF cavities are essential components of particle accelerators that, depending on the design, can perform multiple functions, including bunching, focusing, decelerating, and accelerating a beam of charged particles. Engineers are working to model the RF cavities required for upgrading the 40-year old Booster synchrotron. It is a rather complicated process to refurbish, test, and qualify the upgraded RF cavities to sustain an increased repetition rate of the RF field required to produce proton beams at double the current intensity. Both multiphysics simulation and physical measurements are used to evaluate the RF, thermal, and mechanical properties of the Booster RF cavities.

43 PARTICLE ACCELERATORS↗

Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams

Purpose: Laser plasma acceleration can potentially replace large and expensive cyclotrons or synchrotrons for radiotherapy with protons and ions. On the way toward a clinical implementation, various challenges such as the maximum obtainable energy still remain to be solved. In any case, laser accelerated particles exhibit differences compared to particles from conventional accelerators. They typically have a wide energy spread and the beam is extremely pulsed (i.e., quantized) due to the pulsed nature of the employed lasers. The energy spread leads to depth dose curves that do not show a pristine Bragg peak but a wide high dose area, making precise radiotherapy impossible without an additional energy selection system. Problems with the beam quantization include the limited repetition rate and the number of accelerated particles per laser shot. This number might be too low, which requires a high repetition rate, or it might be too high, which requires an additional fluence selection system to reduce the number of particles. Trying to use laser accelerated particles in a conventional way such as spot scanning leads to long treatment times and a high amount of secondary radiation produced when blocking unwanted particles. Methods: The authors present methods of beam delivery and treatment planning that are specifically adapted to laser accelerated particles. In general, it is not necessary to fully utilize the energy selection system to create monoenergetic beams for the whole treatment plan. Instead, within wide parts of the target volume, beams with broader energy spectra can be used to simultaneously cover multiple axially adjacent spots of a conventional dose delivery grid as applied in intensity modulated particle therapy. If one laser shot produces too many particles, they can be distributed over a wider area with the help of a scattering foil and a multileaf collimator to cover multiple lateral spot positions at the same time. These methods are called axial and lateral clustering and reduce the number of particles that have to be blocked in the beam delivery system. Furthermore, the optimization routine can be adjusted to reduce the number of dose spots and laser shots. The authors implemented these methods into a research treatment planning system for laser accelerated particles. Results: The authors' proposed methods can decrease the amount of secondary radiation produced when blocking particles with wrong energies or when reducing the total number of particles from one laser shot. Additionally, caused by the efficient use of the beam, the treatment time is reduced considerably. Both improvements can be achieved without extensively changing the quality of the treatment plan since conventional intensity modulated particle therapy usually includes a certain amount of unused degrees of freedom which can be used to adapt to laser specific properties. Conclusions: The advanced beam delivery and treatment planning methods reduce the need to have a perfect laser-based accelerator reproducing the properties of conventional accelerators that might not be possible without increasing treatment time and secondary radiation to the patient. The authors show how some of the differences to conventional beams can be overcome and efficiently used for radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple delivery cesium oven system for negative ion sources

Distribution of cesium in large negative ion beam sources to be operational in ITER, is presently based on the use of three or more cesium ovens, which operate simultaneously and are controlled remotely. However, use of multiple Cs ovens simultaneously is likely to pose difficulties in operation and maintenance of the ovens. An alternate method of Cs delivery, based on a single oven distribution system is proposed as one which could reduce the need of simultaneous operation of many ovens. A proof of principle experiment verifying the concept of a multinozzle distributor based Cs oven has been carried out at Institute for Plasma Research. It is also observed that the Cs flux is not controlled by Cs reservoir temperature after few hours of operation but by the temperature of the distributor which starts behaving as a Cs reservoir.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of fragment production for fragment charge numbers between one and eight versus the degree of excitation of the fragmenting nucleus in {sup 16}Op collisions at a momentum of 3.25 GeV/c per nucleon

New experimental data on the mean-multiplicity distribution of fragments whose charge number ranges between one and eight and on the distribution of the mean kinetic energy of few-nucleon fragments (A = 1-3) are presented versus the 4-momentum transfer from the target proton to the oxygen nucleus in {sup 16}Op collisions at a momentum of 3.25 GeV/c per nucleon. These data are systematically compared with the predictions of the cascade-fragmentation-evaporation model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal characterization of the build chamber in electron beam melting

Electron beam powder bed fusion, commonly termed electron beam melting (EBM), offers great versatility in multiple-part processes and can produce high quality as-built components due to low residual stresses. The EBM process is complex and requires careful thermal management, including uniform and consistent preheating of the powder bed, in order to ensure quality and consistency of the product. However, most of the simulations in the literature focus on the selective melting stage of the process. As of today, optimal conditions for initial pre-heating temperatures are only available for specific materials. Thus, in order to extend the EBM technology to other desired build materials, a much better understanding of the pre-heating stages is required. In this work, numerical and experimental approaches are combined in order to investigate the effects and sensitivities of heat removal from the build plate during EBM pre-heating stages. For this purpose, a carefully reconstructed numerical model of the build chamber of an ARCAM Q20 + machine is developed. It includes all main parts of the chamber and all relevant heat transfer mechanisms, whereas special attention is paid to radiation heat exchange between various bodies. In order to validate the model, dedicated experiments are performed, in which a system of thermocouples is installed in the build chamber, allowing direct measurement of the local temperatures of the start-plate and heat shields. A good agreement between the simulation and experimental findings is achieved, leading to a better understanding of the thermal processes characteristic to the pre-heating stages. This basic analysis is followed by a representative pre-heating case, where a powder bed is also considered. The energy required to obtain the desired pre-heating temperatures is evaluated, and the role of the powder bed in heat transfer within the chamber is assessed. The pre-heating stage, simulated in the present work, is supposed to create proper conditions for sintering and consequent melting of the powder, which are highly dependent on the local temperatures and heat transfer features. Thus, the findings of the reported work present a step towards a better understanding of the thermal processes that characterize EBM. The reported model can be further used to provide realistic boundary condition inputs for other meso- or macro-scale models as a function of time and geometry. The model can serve also for verification of machine settings, i.e., jump-safe and melt-safe ones which actually provide desired preheat, and for development of settings for new powders.

36 MATERIALS SCIENCE↗

Critical Appraisal of Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Metastases to Abdominal Lymph Nodes

Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose{sub min} >95%, Dose{sub max} <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V{sub 15Gy} <35% for both kidneys, V{sub 36Gy} <1% for duodenum, V{sub 36Gy} <3% for stomach and small bowel, V{sub 15Gy} <(total liver volume - 700 cm{sup 3}) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V{sub 95%} = 90.2% +- 5.2% for RA compared with 82.5% +- 9.6% and 84.5% +- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +- 211 for RA, 2583 +- 699 for IM, and 1554 +- 153 for CRT. Effective treatment time resulted as follows: 3.7 +- 0.4 min for RA, 10.6 +- 1.2 min for IM, and 6.3 +- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the initial state and QGP medium from a combined Bayesian analysis of LHC data at 2.76 and 5.02 TeV

Here, we perform a global Bayesian analysis of a modern event-by-event heavy-ion collision model and LHC data at √s = 2.76 and 5.02 TeV. After calibration, the model simultaneously describes multiplicity, transverse momentum, and flow data at both beam energies. We report new constraints on the scaling of initial-state entropy deposition and QGP transport coefficients, including a quantitative estimate of the temperature-dependent shear viscosity (η/s)( T ).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM↗

A first generation compact microbeam radiation therapy system based on carbon nanotube X-ray technology

We have developed a compact microbeam radiation therapy device using carbon nanotube cathodes to create a linear array of narrow focal line segments on a tungsten anode and a custom collimator assembly to select a slice of the resulting wedge-shaped radiation pattern. Effective focal line width was measured to be 131 μm, resulting in a microbeam width of ∼300 μm. The instantaneous dose rate was projected to be 2 Gy/s at full-power. Peak to valley dose ratio was measured to be >17 when a 1.4 mm microbeam separation was employed. Finally, multiple microbeams were delivered to a mouse with beam paths verified through histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CERN and 60 years of science for peace

This paper presents CERN as it celebrates its 60{sup th} Anniversary since its founding. The presentation first discusses the mission of CERN and its role as an inter-governmental Organization. The paper also reviews aspects of the particle physics research programme, looking at both current and future accelerator-based facilities at the high-energy and intensity frontiers. Finally, the paper considers issues beyond fundamental research, such as capacity-building and the interface between Art and Science.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Invited article: Broadband highly-efficient dielectric metadevices for polarization control

Metadevices based on dielectric nanostructured surfaces with both electric and magnetic Mie-type resonances have resulted in the best efficiency to date for functional flat optics with only one disadvantage: a narrow operational bandwidth. Here we experimentally demonstrate broadband transparent all-dielectric metasurfaces for highly efficient polarization manipulation. We utilize the generalized Huygens principle , with a superposition of the scattering contributions from several electric and magnetic multipolar modes of the constituent meta-atoms, to achieve destructive interference in reflection over a large spectral bandwidth. Furthermore, by employing this novel concept, we demonstrate reflectionless (~90% transmission) half-wave plates, quarter-wave plates, and vector beam q-plates that can operate across multiple telecom bands with ~99% polarization conversion efficiency.

36 MATERIALS SCIENCE↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

HERSCHEL OBSERVATIONS OF INTERSTELLAR CHLORONIUM

Using the Herschel Space Observatory's Heterodyne Instrument for the Far-Infrared, we have observed para-chloronium (H{sub 2}Cl{sup +}) toward six sources in the Galaxy. We detected interstellar chloronium absorption in foreground molecular clouds along the sight lines to the bright submillimeter continuum sources Sgr A (+50 km s{sup -1} cloud) and W31C. Both the para-H{sup 35}{sub 2}Cl{sup +} and para-H{sup 37}{sub 2}Cl{sup +} isotopologues were detected, through observations of their 1{sub 11}-0{sub 00} transitions at rest frequencies of 485.42 and 484.23 GHz, respectively. For an assumed ortho-to-para ratio (OPR) of 3, the observed optical depths imply that chloronium accounts for {approx}4%-12% of chlorine nuclei in the gas phase. We detected interstellar chloronium emission from two sources in the Orion Molecular Cloud 1: the Orion Bar photodissociation region and the Orion South condensation. For an assumed OPR of 3 for chloronium, the observed emission line fluxes imply total beam-averaged column densities of {approx}2 Multiplication-Sign 10{sup 13} cm{sup -2} and {approx}1.2 Multiplication-Sign 10{sup 13} cm{sup -2}, respectively, for chloronium in these two sources. We obtained upper limits on the para-H{sup 35}{sub 2}Cl{sup +} line strengths toward H{sub 2} Peak 1 in the Orion Molecular cloud and toward the massive young star AFGL 2591. The chloronium abundances inferred in this study are typically at least a factor {approx}10 larger than the predictions of steady-state theoretical models for the chemistry of interstellar molecules containing chlorine. Several explanations for this discrepancy were investigated, but none has proven satisfactory, and thus the large observed abundances of chloronium remain puzzling.

79 ASTRONOMY AND ASTROPHYSICS↗

Wilson Prize article: Reflections on our experiences with developing the theory of intrabeam scattering

We discuss our experiences with developing detailed theoretical descriptions of intrabeam scattering in particle accelerators. We focus on the historical importance of understanding intrabeam scattering for the successful operation of a variety of accelerators around the world. In doing so, we highlight the fact that the theoretical understanding of intrabeam scattering played a crucial role in the discovery of the top quark at Fermilab, intermediate vector bosons W ± , Z and the Higgs particle at CERN, and the perfect liquid quark-gluon plasma at Brookhaven’s Relativistic Heavy Ion Collider. We describe several useful high energy approximations to intrabeam scattering, including those that utilize a Modified Piwinski high energy approximation by Karl Bane that has gained wide usage in applications to electron damping rings and advanced light sources. Finally, we comment on the fact that a detailed understanding of intrabeam scattering at synchrotron-based advanced light sources is empowering many transformational discoveries in a myriad of disciplines.

43 PARTICLE ACCELERATORS↗