Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Experimental and analytical comparison of flowfields in a 110 N (25 Lbf) H2/O2 rocket

A gaseous hydrogen/gaseous oxygen 110 N (25 lbf) rocket has been examined through the RPLUS code using the full Navier-Stokes equations with finite-rate chemistry. Performance tests were conducted on the rocket in an altitude test facility. Preliminary parametric analyses have been performed for a range of mixture ratios and fuel film cooling percentages. It is shown that the computed values of specific impulse and characteristic exhaust velocity follow the trend of the experimental data. Specific impulse computed by the code is lower than the comparable test values by about two to three percent. The computed characteristic exhaust velocity values are lower than the comparable test values by three to four percent. Thrust coefficients computed by the code are found to be within two percent of the measured values. It is concluded that the discrepancy between computed and experimental performance values could not be attributed to experimental uncertainty.

Reed, Brian D.↗

Heat Loads Due to Small Penetrations in Multilayer Insulation Blankets

The main penetrations (supports and piping) through multilayer insulation systems for cryogenic tanks have been previously addressed by heat flow measurements. Smaller penetrations due to fasteners and attachments are now experimentally investigated. The use of small pins or plastic garment tag fasteners to each the handling and construction of multilayer insulation (MLI) blankets goes back many years. While it has long been understood that penetrations and other discontinuities degrade the performance of the MLI blanket, quantification of this degradation has generally been lumped into gross performance multipliers (often called degradation factors or scale factors). Small penetrations contribute both solid conduction and radiation heat transfer paths through the blanket. The conduction is down the stem of the structural element itself while the radiation is through the hole formed during installation of the pin or fastener. Analytical models were developed in conjunction with MLI perforation theory and Fouriers Law. Results of the analytical models are compared to experimental testing performed on a 10 layer MLI blanket with approximately 50 small plastic pins penetrating the test specimen. The pins were installed at 76-mm spacing inches in both directions to minimize the compounding of thermal effects due to localized compression or lateral heat transfer. The testing was performed using a liquid nitrogen boil-off calorimeter (Cryostat-100) with the standard boundary temperatures of 293 K and 78 K. Results show that the added radiation through the holes is much more significant than the conduction down the fastener. The results are shown to be in agreement with radiation theory for perforated films.

Structural attachments↗

The second generation Singapore high resolution proton beam writing facility

A new proton beam focusing facility, designed for proton beam writing (PBW) applications has been tested. PBW allows for proximity free structuring of high aspect ratio, high-density 3D nanostructures. The new facility is designed around OM52 compact quadrupole lenses capable of operating in a variety of high demagnification configurations. Performance tests show that proton beams can be focused down to 19.0 x 29.9 nm{sup 2} and single line scans show a beam width of 12.6 nm. The ultimate goal of sub 10 nm structuring with MeV protons will be discussed.

43 PARTICLE ACCELERATORS↗

Validation of a fault-tolerant multiprocessor: Baseline experiments and workload implementation

In the future, aircraft must employ highly reliable multiprocessors in order to achieve flight safety. Such computers must be experimentally validated before they are deployed. This project outlines a methodology for validating reliable multiprocessors. The methodology begins with baseline experiments, which tests a single phenomenon. As experiments progress, tools for performance testing are developed. The methodology is used, in part, on the Fault Tolerant Multiprocessor (FTMP) at NASA-Langley's AIRLAB facility. Experiments are designed to evaluate the fault-free performance of the system. Presented are the results of interrupt baseline experiments performed on FTMP. Interrupt causing exception conditions were tested, and several were found to have unimplemented interrupt handling software while one had an unimplemented interrupt vector. A synthetic workload model for realtime multiprocessors is then developed as an application level performance analysis tool. Details of the workload implementation and calibration are presented. Both the experimental methodology and the synthetic workload model are general enough to be applicable to reliable multiprocessors beside FTMP.

Feather, Frank↗

Elastomer mounted rotors - An alternative for smoother running turbomachinery

This paper describes the design of elastomeric bearing supports for a rotor built to simulate the power turbine of an advanced gas turbine engine which traverses two bending critical speeds. The elastomer dampers were constructed so as to minimize rotor dynamic response at the critical speeds. Results are presented of unbalance response tests performed with two different elastomer materials. These results showed that the resonances on the elastomer-mounted rotor were well damped for both elastomer materials and showed linear response to the unbalance weights used for response testing. Additional tests were performed using solid steel supports at either end (hand-mounted), which resulted in drastically increased sensitivity and nonlinear response, and with steel supports in one end of the rotor and the elastomer at the other, which yielded results which were between the soft- and hard-mounted cases. It is concluded that elastomeric supports are a viable alternative to other methods of mounting flexible rotors, that damping was well in excess of predictions and that elastomeric supports are tolerant of small rotor misalignments.

Tecza, J. A.↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

Space Fission Propulsion Testing and Development Progress

Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. Testing can be divided into two categories, non-nuclear tests and nuclear tests. Full power nuclear tests of space fission systems we expensive, time consuming, and of limited use, even in the best of programmatic environments. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. Non-nuclear tests are affordable and timely, and the cause of component and system failures can be quickly and accurately identified. MSFC is leading a Safe Affordable Fission Engine (SAFE) test series whose ultimate goal is the demonstration of a 300 kW flight configuration system using non-nuclear testing. This test series is carried out in collaboration with other NASA centers, other government agencies, industry, and universities. If SAFE-related nuclear tests are desired they will have a high probability of success and can be performed at existing nuclear facilities. The paper describes the SAFE non-nuclear test series, which includes test article descriptions, test results and conclusions, and future test plans.

VanDyke, Melissa↗

A Hybrid Parachute Simulation Environment for the Orion Parachute Development Project

A parachute simulation environment (PSE) has been developed that aims to take advantage of legacy parachute simulation codes and modern object-oriented programming techniques. This hybrid simulation environment provides the parachute analyst with a natural and intuitive way to construct simulation tasks while preserving the pedigree and authority of established parachute simulations. NASA currently employs four simulation tools for developing and analyzing air-drop tests performed by the CEV Parachute Assembly System (CPAS) Project. These tools were developed at different times, in different languages, and with different capabilities in mind. As a result, each tool has a distinct interface and set of inputs and outputs. However, regardless of the simulation code that is most appropriate for the type of test, engineers typically perform similar tasks for each drop test such as prediction of loads, assessment of altitude, and sequencing of disreefs or cut-aways. An object-oriented approach to simulation configuration allows the analyst to choose models of real physical test articles (parachutes, vehicles, etc.) and sequence them to achieve the desired test conditions. Once configured, these objects are translated into traditional input lists and processed by the legacy simulation codes. This approach minimizes the number of sim inputs that the engineer must track while configuring an input file. An object oriented approach to simulation output allows a common set of post-processing functions to perform routine tasks such as plotting and timeline generation with minimal sensitivity to the simulation that generated the data. Flight test data may also be translated into the common output class to simplify test reconstruction and analysis.

Moore, James W.↗

An Overview of Facilities and Capabilities to Support the Development of Nuclear Thermal Propulsion

Abstract. The future of American space exploration depends on the ability to rapidly and economically access locations of interest throughout the solar system. There is a large body of work (both in the US and the Former Soviet Union) that show that Nuclear Thermal Propulsion (NTP) is the most technically mature, advanced propulsion system that can enable this rapid and economical access by its ability to provide a step increase above what is a feasible using a traditional chemical rocket system. For an NTP system to be deployed, the earlier measurements and recent predictions of the performance of the fuel and the reactor system need to be confirmed experimentally prior to launch. Major fuel and reactor system issues to be addressed include fuel performance at temperature, hydrogen compatibility, fission product retention, and restart capability. The prime issue to be addressed for reactor system performance testing involves finding an affordable and environmentally acceptable method to test a range of engine sizes using a combination of nuclear and non-nuclear test facilities. This paper provides an assessment of some of the capabilities and facilities that are available or will be needed to develop and test the nuclear fuel, and reactor components. It will also address briefly options to take advantage of the greatly improvement in computation/simulation and materials processing capabilities that would contribute to making the development of an NTP system more affordable. Keywords: Nuclear Thermal Propulsion (NTP), Fuel fabrication, nuclear testing, test facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shear Strength Measurement Benchmarking Tests for K Basin Sludge Simulants

Equipment development and demonstration testing for sludge retrieval is being conducted by the K Basin Sludge Treatment Project (STP) at the MASF (Maintenance and Storage Facility) using sludge simulants. In testing performed at the Pacific Northwest National Laboratory (under contract with the CH2M Hill Plateau Remediation Company), the performance of the Geovane instrument was successfully benchmarked against the M5 Haake rheometer using a series of simulants with shear strengths (τ) ranging from about 700 to 22,000 Pa (shaft corrected). Operating steps for obtaining consistent shear strength measurements with the Geovane instrument during the benchmark testing were refined and documented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A convenient miniature test platform for polyelectrolyte membrane fuel-cell research

We report a simple and convenient small-scale fuel-cell test platform was created from a commercial compression fitting and graphite rod current collectors and used to conduct diagnostic tests on disk-shaped membrane-electrode assemblies (MEAs) fabricated from Nafion membranes and Nafion-impregnated platinum-on-carbon-cloth anodes and cathodes. A key advantage of this test platform is that it requires very little material, perhaps just a few milligrams, to conduct a fuel-cell test on a supported catalyst. Electrochemically-active surface area (ECSA) values for supported platinum on carbon-cloth electrodes were obtained by in-situ (in the fuel cell) and ex-situ (in liquid electrolyte) cyclic voltammetry on similarly-prepared electrodes, and values obtained by these methods were compared with each other to estimate the fraction of platinum catalyst contacted by the Nafion ionomer in the fuel-cell cathode. Polarization curves were acquired under controlled-potential conditions using slow-scan cyclic and sampled-current voltammetry and potential-step amperometry methods with conventional electroanalytical instrumentation. Tests performed using this platform are complementary to rotating disk electrode (RDE) voltammetry tests which also allow for catalyst testing on small amounts of material, albeit in the presence of liquid electrolyte, and are commonly used for initial screening of new fuel-cell catalysts. They are also complementary to conventional fuel-cell testing that is commonly performed on MEAs having active areas more than 100 times larger than that in the present cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extravehicular activity compatibility evaluation of developmental hardware for assembly and repair of precision reflectors

This report presents results of tests performed in neutral buoyancy by two pressure-suited test subjects to simulate Extravehicular Activity (EVA) tasks associated with the on-orbit construction and repair of a precision reflector spacecraft. Two complete neutral buoyancy assemblies of the test article (tetrahedral truss with three attached reflector panels) were performed. Truss joint hardware, two different panel attachment hardware concepts, and a panel replacement tool were evaluated. The test subjects found the operation and size of the truss joint hardware to be acceptable. Both panel attachment concepts were found to be EVA compatible, although one concept was judged by the test subjects to be considerably easier to operate. The average time to install a panel from a position within arm's reach of the test subjects was 1 min 14 sec. The panel replacement tool was used successfully to demonstrate the removal and replacement of a damaged reflector panel in 10 min 25 sec.

Heard, Walter L., Jr.↗

Development and Capabilities of ISS Flow Boiling and Condensation Experiment

An experimental facility to perform flow boiling and condensation experiments in long duration microgravity environment is being designed for operation on the International Space Station (ISS). This work describes the design of the subsystems of the FBCE including the Fluid subsystem modules, data acquisition, controls, and diagnostics. Subsystems and components are designed within the constraints of the ISS Fluid Integrated Rack in terms of power availability, cooling capability, mass and volume, and most importantly the safety requirements. In this work we present the results of ground-based performance testing of the FBCE subsystem modules and test module which consist of the two condensation modules and the flow boiling module. During this testing, we evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, heat loss from different modules and components, and performance of the test modules. These results will be used in the refinement of the flight system design and build-up of the FBCE which is manifested for flight in late 2017-early 2018.

microgravity↗

Boundary Layer Protuberance Simulations in Channel Nozzle Arc-Jet

Two protuberance designs were modeled in the channel nozzle of the NASA Johnson Space Center Atmospheric Reentry Materials and Structures Facility with the Data-Parallel Line Relaxation computational fluid dynamics code. The heating on the protuberance was compared to nominal baseline heating at a single fixed arc-jet condition in order to obtain heating augmentation factors for flight traceability in the Boundary Layer Transition Flight Experiment on Space Shuttle Orbiter flights STS-119 and STS-128. The arc-jet simulations were performed in conjunction with the actual ground tests performed on the protuberances. The arc-jet simulations included non-uniform inflow conditions based on the current best practices methodology and used variable enthalpy and constant mass flow rate across the throat. Channel walls were modeled as fully catalytic isothermal surfaces, while the test section (consisting of Reaction Cured Glass tiles) was modeled as a partially catalytic radiative equilibrium wall. The results of the protuberance and baseline simulations were compared to the applicable ground test results, and the effects of the protuberance shock on the opposite channel wall were investigated.

Marichalar, J. J.↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Line focus systems.

Improving the thermal performance of a trough plant will lower the LCOE: (1) Improve mirror alignment using the TOPCAT system - Current - increase optical intercept of existing trough solar power plants, Future - allows larger apertures with same receiver size in new trough solar power plants, and Increased concentration ratios/collection efficiencies & economies of scale; and (2) Improve tracking using a closed loop tracking system - Open loop tracking currently used own experience and from industry show need for a improved method. Performance testing of a Trough module and/or receiver on the rotating platform: (1) Installed costs of a trough plant are high. A significant portion of this is the material and assembly cost of the trough module. These costs need to be reduced without sacrificing performance; and (2) New receiver coatings with lower heat loss and higher absorbtivity. TOPCAT system is an optical evaluation tool for parabolic trough solar collectors. Aspects of the TOPCAT system are: (1) Practical, rapid, and cost effective; (2) Inherently aligns mirrors to the receiver of an entire solar collector array (SCA); (3) Can be used for existing installations -no equivalent tool exits; (4) Can be used during production; (5) Currently can be used on LS-2 or LS-3 configurations, but can be easily modified for any configuration; and (6)Generally, one time use.

14 SOLAR ENERGY↗

Cementitious Waste Form Development for Treatment of EMF Evaporator Bottoms - 18611

Direct Feed Low-Activity Waste operations at the Hanford Site (Washington State, USA) involve concentrating the Hanford low-activity waste (LAW) melter off-gas condensate waste stream by evaporation at the Effluent Management Facility (EMF) followed by recycle back to the melter feed. The EMF evaporator bottoms waste stream is expected to contain variable, high levels of halides and sulfate that could strain LAW melter performance and co-mingled radionuclides, technetium-99 ({sup 99}Tc) and iodine-129 ({sup 129}I), that readily volatilize in the LAW melter and are expected to accumulate during recycle. To this end, there is a need for alternative disposition paths for the EMF evaporator bottoms waste stream that bypass recycling to the LAW melter. One such alternative is solidification in low-temperature cementitious waste forms (CWFs) that meet disposal facility acceptance criteria. The work herein addresses recent waste form development and testing performed to identify CWF candidates that meet off-site disposal acceptance criteria and/or on-site Hanford Integrated Disposal Facility waste acceptance criteria. Phase one testing activities included the production and evaporation of simulated EMF evaporator feed from the Hanford Waste Treatment and Immobilization Plant melter offgas effluent liquid secondary waste stream, which was then analyzed to demonstrate the behavior and fate of contaminants of concern (COCs). Based on analyses from these preliminary tests, a simulant for the EMF evaporator bottoms waste stream was formulated and used to evaluate several dry material compositions proposed for CWF development and testing. In particular, dry ingredient recipes used in early testing efforts contained a combination of ordinary Portland cement (OPC), Class F fly ash (FA), blast furnace slag (BFS), Aquaset{sup R} II-H, and/or Aquaset{sup R} II-GH to generate CWFs at various water-to-dry material ratios. CWFs were then tested according to the Toxicity Characteristic Leaching Procedure (TCLP) for COCs, such as Cr, Zn, As, and Se, to determine which specimens comply with land disposal restrictions (40 CFR 268). The results of TCLP testing showed that chromium leaching was a persistent challenge, except when using the original Cast Stone dry ingredient recipe (8% OPC, 47% BFS, 45% FA) to immobilize the EMF evaporator bottoms simulant. Improving Cr immobilization and evaluating leaching behavior for COC Hg were identified as objectives for the second phase of testing. During second phase testing efforts, a screening test was performed to determine whether the bulk EMF waste composition is a factor in producing an acceptable solidified waste form. A series of eight simulants with varying concentrations of major salts of boron, chloride, nitrite, and sulfate were prepared and immobilized using three dry ingredient recipes. Each dry ingredient recipe contained two to three of the following: BFS, OPC, FA, and Aquaset{sup R} II-GH. All eight simulants were spiked with Zn, Cr, As, Se, and Hg prior to production of the CWFs, similar to previous tests, and used to test for residual free liquids and TCLP analysis. The TCLP results indicate that all phase two formulated CWFs meet land disposal requirements when compared to Universal Treatment Standards (40 CFR 268) for hazardous wastes, regardless of simulant composition. Furthermore, re-absorption of residual free liquids is most quickly achieved for nearly all simulant compositions using the original Cast Stone recipe; however, replicas analysis is required to corroborate these findings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗