Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Investigation of thermal resistance and power consumption in Ga-doped indium oxide (In{sub 2}O{sub 3}) nanowire phase change random access memory

The resistance stability and thermal resistance of phase change memory devices using ∼40 nm diameter Ga-doped In{sub 2}O{sub 3} nanowires (Ga:In{sub 2}O{sub 3} NW) with different Ga-doping concentrations have been investigated. The estimated resistance stability (R(t)/R{sub 0} ratio) improves with higher Ga concentration and is dependent on annealing temperature. The extracted thermal resistance (R{sub th}) increases with higher Ga-concentration and thus the power consumption can be reduced by ∼90% for the 11.5% Ga:In{sub 2}O{sub 3} NW, compared to the 2.1% Ga:In{sub 2}O{sub 3} NW. The excellent characteristics of Ga-doped In{sub 2}O{sub 3} nanowire devices offer an avenue to develop low power and reliable phase change random access memory applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication and long-wavelength characterization of neat and chemically modified graphene

Graphene, a single- or several layer-thick carbon, attracts significant research activity because of its exceptional material properties. Graphene is a promising material for optoelectronic applications. Neat graphene demonstrates potential as a material for long wavelength photodetectors working at elevated temperatures. Chemical modification of graphene opens up many new applications of this material in electronics, in new composite materials, and in new catalysts for different chemical processes. Chemical vapor deposition-grown large-area graphene can be successfully modified with the creation of benzyne attachments. The investigation of microwave properties is an important part of graphene research. Two variants of near-field long wavelength microscopy were found efficient with graphene. Measurements with a probe formed by an electrically open end of a 4 GHz half-lambda parallel-strip transmission line resonator allow the implementation of an electrodynamic model of graphene microwave impedance. The results of near-field scanning superconducting quantum interference device (SQUID) RF microscopy of graphite and graphene at 200 MHz shed light on mechanisms of AC graphene response: screening currents induced in graphene by an external RF magnetic field tend to localize near structural defects.

36 MATERIALS SCIENCE↗

Probing the thiol-gold planar interface by spin polarized tunneling

Reports of induced magnetism at thiol-gold interface have generated considerable recent interest. In these studies, the sample magnetization was generally measured by superconducting quantum interference device magnetometry which has limitation in determining surface and interface magnetism. In this work, we have fabricated planar tunnel junctions incorporating a thiol-gold interface. An observed room temperature humidity effect together with low temperature inelastic electron tunneling spectroscopy confirmed the existence of a thiol-gold interface in the organic-inorganic hybrid heterostructure. Spin polarized tunneling measurements were performed to probe the spin polarization at the thiol-gold interface; however, the obtained spin polarized tunneling spectra indicate no measurable spin polarization at the thiol-gold interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication and characterization of shunted μ-SQUID

In order to eliminate hysteresis, we have fabricated and characterized niobium based shunted micron size superconducting quantum interference devices (μ-SQUIDs). We find a wide temperature range where these μ-SQUIDs are non-hysteretic in nature and show a very good I{sub c} vs. B oscillations in hysteretic regime and V vs. B oscillations in non-hysteretic regime. Here we report the characteristics of a shunted- μ-SQUID (Wf38LS72D5). In this device we have achieved a large voltage modulation, in non-hysteretic regime, at various temperatures including such as 1.1 mV at 6.62 K with a transfer function V{sub Φ} = 7.2mV/Φ{sub 0}. The figures within the original article PDF file, as supplied to AIP Publishing, were affected by a PDF-processing error. Consequently, the article re-flowed and pagination increased from 3 to 4 pages. This article was updated on 14 May 2014 to correct the PDF-processing error, with the scientific content remaining unchanged. Readers are advised that the replacement article PDF file contains an additional blank page to preserve the original pagination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Storage and on-demand release of microwaves using superconducting resonators with tunable coupling

We present a system which allows to tune the coupling between a superconducting resonator and a transmission line. This storage resonator is addressed through a second, coupling resonator, which is frequency-tunable and controlled by a magnetic flux applied to a superconducting quantum interference device. We experimentally demonstrate that the lifetime of the storage resonator can be tuned by more than three orders of magnitude. A field can be stored for 18 μs when the coupling resonator is tuned off resonance and it can be released in 14 ns when the coupling resonator is tuned on resonance. The device allows capture, storage, and on-demand release of microwaves at a tunable rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural, optical, and magnetic properties of highly-resistive Sm-implanted GaN thin films

Samarium ions of 200 keV in energy were implanted into highly-resistive molecular-beam-epitaxy grown GaN thin films with a focused-ion-beam implanter at room temperature. The implantation doses range from 1 × 10{sup 14} to 1 × 10{sup 16 }cm{sup −2}. Structural properties studied by x-ray diffraction and Raman-scattering spectroscopy revealed Sm incorporation into GaN matrix without secondary phase. The optical measurements showed that the band gap and optical constants changed very slightly by the implantation. Photoluminescence measurements showed emission spectra similar to p-type GaN for all samples. Magnetic investigations with a superconducting quantum interference device identified magnetic ordering for Sm dose of and above 1 × 10{sup 15 }cm{sup −2} before thermal annealing, while ferromagnetism was only observed after thermal annealing from the sample with highest Sm dose. The long-range magnetic ordering can be attributed to interaction of Sm ions through the implantation-induced Ga vacancy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic anisotropy in ultrathin Fe films on GaAs, ZnSe, and Ge (001) substrates

We discuss magnetic anisotropy parameters of ferromagnetic body-centered cubic (bcc) Fe films grown by molecular beam epitaxy (MBE) on (001) substrates of face-centered cubic (fcc) GaAs, ZnSe, and Ge. High-quality MBE growth of these metal/semiconductor combinations is made possible by the fortuitous atomic relationship between the bcc Fe and the underlying fcc semiconductor surfaces, resulting in excellent lattice match. Magnetization measurements by superconducting quantum interference device (SQUID) indicate that the Fe films grown on (001) GaAs surfaces are characterized by a very strong uniaxial in-plane anisotropy; those grown on (001) Ge surfaces have a fully cubic anisotropy; and Fe films grown on ZnSe represent an intermediate case between the preceding two combinations. Ferromagnetic resonance measurements carried out on these three systems provide a strikingly clear quantitative picture of the anisotropy parameters, in excellent agreement with the SQUID results. Based on these results, we propose that the observed anisotropy of cubic Fe films grown in this way results from the surface reconstruction of the specific semiconductor substrate on which the Fe film is deposited. These results suggest that, by controlling surface reconstruction of the substrate during the MBE growth, one may be able to engineer the magnetic anisotropy in Fe, and possibly also in other MBE-grown ferromagnetic films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconductive quantum interference magnetometer with high sensitivity achieved by an induced resonance

A fully integrated low noise superconducting quantum interference device (SQUID) in a magnetometer configuration is presented. An intrinsic high voltage responsivity as high as 500 μV/Φ{sub 0} has been obtained by introducing a resonance in the voltage – magnetic flux characteristic. This resonance is induced by an integrated superconducting coil surrounding the pick-up coil and connected to one end of the SQUID output. The SQUID magnetometer exhibits a spectral density of magnetic field noise as low as 3 fT/Hz{sup 1/2}. In order to verify the suitability of the magnetometer, measurements of bandwidth and slew rate have been performed and compared with those of the same device without the resonance and with additional positive feedback. Due to their good characteristics such devices can be employed in a large number of applications including biomagnetism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} intrinsic Josephson junction stacks with improved cooling: Coherent emission above 1 THz

We report on Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} (BSCCO) intrinsic Josephson junction stacks with improved cooling, allowing for a remarkable increase in emission frequency compared to the previous designs. We started with a BSCCO stack embedded between two gold layers. When mounted in the standard way to a single substrate, the stack emits in the range of 0.43–0.82 THz. We then glued a second, thermally anchored substrate onto the sample surface. The maximum voltage of this better cooled and dimension-unchanged sample was increased and, accordingly, both the emission frequencies and the tunable frequency range were significantly increased up to 1.05 THz and to 0.71 THz, respectively. This double sided cooling may also be useful for other “hot” devices, e.g., quantum cascade lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The atomic magnetometer: A new era in biomagnetism

The high cost and impracticality of SQUID (Superconducting QUantum Interference Device) magnetometers has limited the expansion of magnetoencephalography (MEG) and magnetocardiography (MCG), especially in countries where the cost of liquid helium is high. A recent breakthrough, however, has the potential to radically change this situation. In 2003, a group at Princeton University demonstrated an atomic magnetometer, known as the SERF (spin-exchange free relaxation) magnetometer, with unprecedented sensitivity. Since then, several research groups have utilized SERF magnetometers to record MEG, MCG, and fetal MCG signals. Despite some modest drawbacks, it now seems almost certain that SERF magnetometers can replace SQUIDs for many applications. With a price tag that is likely to be far less than that of SQUIDs, SERF magnetometers can propel the next wave of growth in biomagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Optical receiver system for 152-channel magnetoencephalography

An optical receiver system composing 13 serial data restore/synchronizer modules and a single module combiner converted optical 32-bit serial data into 32-bit synchronous parallel data for a computer to acquire 152-channel magnetoencephalography (MEG) signals. A serial data restore/synchronizer module identified 32-bit channel-voltage bits from 48-bit streaming serial data, and then consecutively reproduced 13 times of 32-bit serial data, acting in a synchronous clock. After selecting a single among 13 reproduced data in each module, a module combiner converted it into 32-bit parallel data, which were carried to 32-port digital input board in a computer. When the receiver system together with optical transmitters were applied to 152-channel superconducting quantum interference device sensors, this MEG system maintained a field noise level of 3 fT/√Hz @ 100 Hz at a sample rate of 1 kSample/s per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simplified HTc rf SQUID to analyze the human cardiac magnetic field

We have developed a four-channel high temperature radio-frequency superconducting quantum interference device (HT{sub c} rf SQUID) in a simple magnetically shielded room (MSR) that can be used to analyze the cardiac magnetic field. It is more robust and compact than existing systems. To achieve the high-quality magnetocardiographic signal, we explored new adaptive software gradiometry technology constructed by the first-order axial gradiometer with a baseline of 80mm, which can adjust its performance timely with the surrounding conditions. The magnetic field sensitivity of each channel was less than 100fT/√Hz in the white noise region. Especially, in the analysis of MCG signal data, we proposed the total transient mapping (TTM) technique to visualize current density map (CDM), then we focused to observe the time-varying behavior of excitation propagation and estimated the underlying currents at T wave. According to the clear 3D imaging, isomagnetic field and CDM, the position and distribution of a current source in the heart can be visualized. It is believed that our four-channel HT{sub c} rf SQUID magnetometer based on biomagnetic system is available to detect MCG signals with sufficient signal-to-noise (SNR) ratio. In addition, the CDM showed the macroscopic current activation pattern, in a way, it has established strong underpinnings for researching the cardiac microscopic movement mechanism and opening the way for its use in clinical diagnosis.

36 MATERIALS SCIENCE↗

Effect of particle size distribution on the structure, hyperfine, and magnetic properties of Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nanopowders

Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nano powders were synthesized by an auto combustion method and then heat treated at different temperatures in air for a fixed time. As a consequence, a distribution in particle size and strain was incorporated within the specimens, as estimated from the Rietveld refinement analysis of the powder x-ray diffraction data. The changes in the microstructure and crystal structure parameters were carefully extracted through the refinement analysis. Thermal annealing causes increment in the dispersion and mean of the size distribution. Reallocation of cations in the lattice sites occur as a consequence of the heat treatment which was manifested in their altered unit cell length (a), r.m.s. strain (〈ε{sup 2}〉{sup 1/2}), oxygen positional parameter (u), metal-oxygen bond lengths (R{sub OA} and R{sub OB}), and the band positions (ν{sub 1}and ν{sub 2}) in the vibrational spectroscopy. We also investigate the hyperfine and magnetic properties of the samples using different instrumental techniques (with different operating time scales) like Mössbauer spectroscopy, electron paramagnetic resonance spectroscopy, and superconducting quantum interference device magnetometry. Results show that the effect of particle size distribution was manifested in their hyperfine field distribution profile, paramagnetic resonance spectra, and magnetic anisotropy energy distribution profile. Co-existence of superparamagnetic and ferrimagnetic phase was recorded at room temperature in the samples when annealed at lower temperature. However, with increase in annealing temperature, the nature of the size distribution changes and ferrimagnetic ordering predominates for the larger size nanoparticles. Thus, the effect of particle size distribution on the structural, hyperfine, and magnetic properties of various Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} nanoparticles was investigated herein which hitherto has not been discussed in the literature.

36 MATERIALS SCIENCE↗

Purity analyses of high-purity organic compounds with nitroxyl radicals based on the Curie–Weiss law

This work reports an attempt to quantify the purities of powders of high-purity organic compounds with stable nitroxyl radicals (namely, 2,2,6,6-tetramethylpiperidine 1-oxyl (TEMPO), 1-oxyl-2,2,6,6-tetramethyl-4-hydroxypiperidine (TEMPOL), and 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl benzoate (4-hydroxy-TEMPO benzoate)) in terms of mass fractions by using our “effective magnetic moment method,” which is based on both the Curie–Weiss law and a fundamental equation of electron paramagnetic resonance (ESR). The temperature dependence of the magnetic moment resulting from the radicals was measured with a superconducting quantum interference device magnetometer. The g value for each compound was measured with an X-band ESR spectrometer. The results of the purities were (0.998 ± 0.064) kg kg{sup −1} for TEMPO, (1.019 ± 0.040) kg kg{sup −1} for TEMPOL, and (1.001 ± 0.048) kg kg{sup −1} for 4-hydroxy-TEMPO benzoate. These results demonstrate that this analytical method as a future candidate of potential primary direct method can measure the purities with expanded uncertainties of approximately 5%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic modification at sub-surface of FeRh bulk by energetic ion beam irradiation

Ferromagnetic layered structure has been made at sub-surface of the antiferromagnetic FeRh bulk samples by high energy He ion beam irradiation. In accordance with the Transport of Ions in Matter simulation, such ion beam can effectively deposit the elastic collision energy in several μm regions in the depth from the surface. Measurement with a superconducting quantum interference device reveals the irradiated samples to be ferromagnetic. Assuming that only the part the energy deposited can be modified to be ferromagnetic, the corresponding irradiation induced magnetization is consistent with the data that we previously reported. On the other hand, the X-ray magnetic circular dichroism (XMCD) spectra for the irradiated samples are totally unchanged as those for the unirradiated samples. Since XMCD signal in total emission yield method is considered to be surface sensitive with a typical probing depth of several nm, the surface magnetic state is maintained to be antiferromagnetic. By utilizing these phenomena, three-dimensional magnetic patterning of FeRh can be realized, which may potentially be used for future magnetic exchange device application such as nano-scale sensors and memories.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗