Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Hot spot-derived shock initiation phenomena in heterogeneous nitromethane

The addition of solid silica particles to gelled nitromethane offers a tractable model system for interrogating the role of impedance mismatches as one type of hot spot 'seed' on the initiation behaviors of explosive formulations. Gas gun-driven plate impact experiments are used to produce well-defined shock inputs into nitromethane-silica mixtures containing size-selected silica beads at 6 wt%. The Pop-plots or relationships between shock input pressure and rundistance (or time)-to-detonation for mixtures containing small (1-4 {micro}m) and large (40 {micro}m) beads are presented. Overall, the addition of beads was found to influence the shock sensitivity of the mixtures, with the smaller beads being more sensitizing than the larger beads, lowering the shock initiation threshold for the same run distance to detonation compared with neat nitromethane. In addition, the use of embedded electromagnetic gauges provides detailed information pertaining to the mechanism of the build-up to detonation and associated reactive flow. Of note, an initiation mechanism characteristic of homogeneous liquid explosives, such as nitromethane, was observed in the nitromethane-40 {micro}m diameter silica samples at high shock input pressures, indicating that the influence of hot spots on the initiation process was minimal under these conditions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors

Purpose: The performance is studied of two newly introduced and previously suggested methods that incorporate priors into inversion schemes associated with data from a recently developed hybrid x-ray computed tomography and fluorescence molecular tomography system, the latter based on CCD camera photon detection. The unique data set studied attains accurately registered data of high spatially sampled photon fields propagating through tissue along 360 deg. projections. Methods: Approaches that incorporate structural prior information were included in the inverse problem by adding a penalty term to the minimization function utilized for image reconstructions. Results were compared as to their performance with simulated and experimental data from a lung inflammation animal model and against the inversions achieved when not using priors. Results: The importance of using priors over stand-alone inversions is also showcased with high spatial sampling simulated and experimental data. The approach of optimal performance in resolving fluorescent biodistribution in small animals is also discussed. Conclusions: Inclusion of prior information from x-ray CT data in the reconstruction of the fluorescence biodistribution leads to improved agreement between the reconstruction and validation images for both simulated and experimental data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of closed cycle sample cooling stage for angle resolved photoemission spectroscopy capable of reaching temperatures below 2 K

We have designed, constructed, and tested a unique cold finger suitable for angle resolved photoemission spectroscopy. This design is based on in situ helium reliquification and utilizes pulse tube cryocooler. The pulse tube can be removed for baking without breaking Ultra High Vacuum (UHV). This design also allows the use of non-UHV heater that can be replaced without the need to vent the system. The cold finger has minimal vibration, operates over a temperature range of 1.7 K–400 K, and has no measurable residual magnetization. Finally, in continuous mode, it can maintain a sample temperature of 2.6 K, while in single shot mode (by pumping on liquid helium), it can reach temperatures down to 1.8 K for a period of several hours.

47 OTHER INSTRUMENTATION↗

Phase Diagrams of Alloys and Their Hydrides via On-Lattice Graph Neural Networks and Limited Training Data

Efficient prediction of sampling-intensive thermodynamic properties is needed to evaluate material performance and permit high-throughput materials modeling for a diverse array of technology applications. To alleviate the prohibitive computational expense of high-throughput configurational sampling with density functional theory (DFT), surrogate modeling strategies like cluster expansion are many orders of magnitude more efficient but can be difficult to construct in systems with high compositional complexity. We therefore employ minimal-complexity graph neural network models that accurately predict and can even extrapolate to out-of-train distribution formation energies of DFT-relaxed structures from an ideal (unrelaxed) crystallographic representation. This enables the large-scale sampling necessary for various thermodynamic property predictions that may otherwise be intractable and can be achieved with small training data sets. Two exemplars, optimizing the thermodynamic stability of low-density high-entropy alloys and modulating the plateau pressure of hydrogen in metal alloys, demonstrate the power of this approach, which can be extended to a variety of materials discovery and modeling problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asbestos Exposure Assessment Database

Exposure to particular hazardous materials in a work environment is dangerous to the employees who work directly with or around the materials as well as those who come in contact with them indirectly. In order to maintain a national standard for safe working environments and protect worker health, the Occupational Safety and Health Administration (OSHA) has set forth numerous precautionary regulations. NASA has been proactive in adhering to these regulations by implementing standards which are often stricter than regulation limits and administering frequent health risk assessments. The primary objective of this project is to create the infrastructure for an Asbestos Exposure Assessment Database specific to NASA Johnson Space Center (JSC) which will compile all of the exposure assessment data into a well-organized, navigable format. The data includes Sample Types, Samples Durations, Crafts of those from whom samples were collected, Job Performance Requirements (JPR) numbers, Phased Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM) results and qualifiers, Personal Protective Equipment (PPE), and names of industrial hygienists who performed the monitoring. This database will allow NASA to provide OSHA with specific information demonstrating that JSC s work procedures are protective enough to minimize the risk of future disease from the exposures. The data has been collected by the NASA contractors Computer Sciences Corporation (CSC) and Wyle Laboratories. The personal exposure samples were collected from devices worn by laborers working at JSC and by building occupants located in asbestos-containing buildings.

Arcot, Divya K.↗

Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscopy

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Using Unfixed, Frozen Tissues to Study Natural Mucin Distribution

Mucins are complex and heavily glycosylated O-linked glycoproteins, which contain more than 70% carbohydrate by weight1-3. Secreted mucins, produced by goblet cells and the gastric mucosa, provide the scaffold for a micrometers-thick mucus layer that lines the epithelia of the gut and respiratory tract3,4. In addition to mucins, mucus layers also contain antimicrobial peptides, cytokines, and immunoglobulins5-9. The mucus layer is an important part of host innate immunity, and forms the first line of defense against invading microorganisms 8,10-12. As such, the mucus is subject to numerous interactions with microbes, both pathogens and symbionts, and secreted mucins form an important interface for these interactions. The study of such biological interactions usually involves histological methods for tissue collection and staining. The two most commonly used histological methods for tissue collection and preservation in the clinic and in research laboratories are: formalin fixation followed by paraffin embedding, and tissue freezing, followed by embedding in cryo-protectant media. Paraffin-embedded tissue samples produce sections with optimal qualities for histological visualization including clarity and well-defined morphology. However, during the paraffin embedding process a number of epitopes become altered and in order to study these epitopes, tissue sections have to be further processed with one of many epitope retrieval methods13. Secreted mucins and lipids are extracted from the tissue during the paraffin-embedding clearing step, which requires prolong incubation with organic solvents (xylene or Citrisolv). Therefore this approach is sub-optimal for studies focusing on the nature and distribution of mucins and mucus in vivo. In contrast, freezing tissues in Optimal Cutting Temperature (OCT) embedding medium avoids dehydration and clearing of the sample, and maintains the sample hydration. This allows for better preservation of the hydrated mucus layer, and thus permits the study of the numerous roles of mucins in epithelial biology. As this method requires minimal processing of the tissue, the tissue is preserved in a more natural state. Therefore frozen tissues sections do not require any additional processing prior to staining and can be readily analyzed using immunohistochemistry methods. We demonstrate the preservation of micrometers-thick secreted mucus layer in frozen colon samples. This layer is drastically reduced when the same tissues are embedded in paraffin. We also demonstrate immunofluorescence staining of glycan epitopes presented on mucins using plant lectins. The advantage of this approach is that it does not require the use of special fixatives and allows utilizing frozen tissues that may already be preserved in the laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

The superior hydrothermal stability of Pd/SSZ-39 in low temperature passive NOx adsorption (PNA) and methane combustion

We successfully synthesized uniform SSZ-39 with an average crystal size of about a micron. Pd (0.7 - 3 wt%) was supported on SSZ-39 with Si/Al ratio ~12. The as-synthesized materials were characterized by FTIR, XRD, Helium Ion Microscopy, HAADF-STEM imaging, 27 Al, 29 Si and H solid state NMR spectroscopic techniques. FTIR studies with CO and NO probe molecules reveal that the 0.7 wt% Pd/SSZ-39 material with Si/Al ~12 has the majority of Pd dispersed atomically as isolated Pd(II) and Pd(II)-OH centers, and thus can be used as a low-temperature passive NOx adsorber. Pd(II)-NO, Pd(II)(OH)(NO) and Pd(II)(CO)(NO) complexes form during PNA in this material. We compare this PNA material directly with the Pd/SSZ-13 system (with Si/Al ratio ~12) and show its superior hydrothermal stability. Remarkably, Pd/SSZ-39 with Si/Al ratio ~12 survives hydrothermal aging up to 815 ºC in 10% H 2 O/Air vapor for 16 hours without significant loss in activity. The SSZ-39 crystal structure remains intact during hydrothermal aging up to 1,000 ºC as we elucidate it with XRD and HAADF-STEM imaging/EDS mapping. However, changes to the framework during such harsh hydrothermal treatment significantly change the NOx release profiles during PNA as evidenced by high-field 27 Al NMR on fresh and aged Pd/SSZ-39 samples as well as PNA performance measurements. Besides PNA application, these hydrothermally very stable materials (3 wt% Pd on SSZ-39 with Si/Al ratio ~12) can be used as a robust methane combustion catalyst under industrially relevant conditions (GHSV~600,000hr -1 ). This catalyst shows minimal deactivation after both harsh hydrothermal aging at 750 and 800 ºC, and prolonged time on stream (105 hrs) at 425 °C. In contrast, both 3wt% Pd/alumina and 3wt% SSZ-13 supported samples lose a significant portion of their activity. Our study opens new avenues to prepare the most hydrothermally stable known Pd/zeolite materials with applications for adsorption and catalytic hydrocarbon combustion under industrially relevant conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing cosmological models with type Ic super luminous supernovae

The use of type Ic super luminous supernovae (SLSNe Ic) to examine the cosmological expansion introduces a new standard ruler with which to test theoretical models. The sample suitable for this kind of work now includes 11 SLSNe Ic, which have thus far been used solely in tests involving the Λ cold dark matter (ΛCDM) model. In this paper, we broaden the base of support for this new, important cosmic probe by using these observations to carry out a one-on-one comparison between the R{sub h}=ct and ΛCDM cosmologies. We individually optimize the parameters in each cosmological model by minimizing the χ{sup 2} statistic. We also carry out Monte Carlo simulations based on these current SLSNe Ic measurements to estimate how large the sample would have to be in order to rule out either model at a ∼99.7% confidence level. The currently available sample indicates a likelihood of ∼70–80% that the R{sub h}=ct universe is the correct cosmology versus ∼20–30% for the standard model. These results are suggestive, though not yet compelling, given the current limited number of SLSNe Ic. We find that if the real cosmology is ΛCDM, a sample of ∼240 SLSNe Ic would be sufficient to rule out R{sub h}=ct at this level of confidence, while ∼480 SLSNe Ic would be required to rule out ΛCDM if the real universe is instead R{sub h}=ct. This difference in required sample size reflects the greater number of free parameters available to fit the data with ΛCDM. If such SLSNe Ic are commonly detected in the future, they could be a powerful tool for constraining the dark-energy equation of state in ΛCDM, and differentiating between this model and the R{sub h}=ct universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Detailed Chemical Abundances for a Benchmark Sample of M Dwarfs from the APOGEE Survey

Individual chemical abundances for 14 elements (C, O, Na, Mg, Al, Si, K, Ca, Ti, V, Cr, Mn, Fe, and Ni) are derived for a sample of M dwarfs using high-resolution, near-infrared H-band spectra from the Sloan Digital Sky Survey-IV/Apache Point Observatory Galactic Evolution Experiment (APOGEE) survey. The quantitative analysis included synthetic spectra computed with 1D LTE plane-parallel MARCS models using the APOGEE Data Release 17 line list to determine chemical abundances. The sample consists of 11 M dwarfs in binary systems with warmer FGK dwarf primaries and 10 measured interferometric angular diameters. To minimize atomic diffusion effects, [X/Fe] ratios are used to compare M dwarfs in binary systems and literature results for their warmer primary stars, indicating good agreement (<0.08 dex) for all studied elements. The mean abundance difference in primaries minus this work's M dwarfs is –0.05 ± 0.03 dex. It indicates that M dwarfs in binary systems are a reliable way to calibrate empirical relationships. A comparison with abundance, effective temperature, and surface gravity results from the APOGEE Stellar Parameter and Chemical Abundances Pipeline (ASPCAP) Data Release 16 finds a systematic offset of [M/H], T eff , log g = +0.21 dex, –50 K, and 0.30 dex, respectively, although ASPCAP [X/Fe] ratios are generally consistent with this study. The metallicities of the M dwarfs cover the range of [Fe/H] = –0.9 to +0.4 and are used to investigate Galactic chemical evolution via trends of [X/Fe] as a function of [Fe/H]. The behavior of the various elemental abundances [X/Fe] versus [Fe/H] agrees well with the corresponding trends derived from warmer FGK dwarfs, demonstrating that the APOGEE spectra can be used to examine Galactic chemical evolution using large samples of selected M dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Misaligned Disks as Obscurers in Active Galaxies

We review critically the evidence concerning the fraction of Active Galactic Nuclei (AGN) which appear as Type 2 AGN, carefully distinguishing strict Type 2 AGN from both more lightly reddened Type 1 AGN, and from low excitation narrow line AGN, which may represent a different mode of activity. Low excitation AGN occur predominantly at low luminosities; after removing these, true Type 2 AGN represent 58{-+}5% of all AGN, and lightly reddened Type 1 AGN a further {approx}15%. Radio, IR, and volume-limited samples all agree in showing no change of Type 2 fraction with luminosity. X-ray samples do show a change with luminosity; we discuss possible reasons for this discrepancy. We test a very simple picture which produces this Type 2 fraction with minimal assumptions. In this picture, infall from large scales occurs in random directions, but must eventually align with the inner accretion flow, producing a severely warped disk on parsec scales. If the re-alignment is dominated by tilt, with minimal twist, a wide range of covering factors is predicted in individual objects, but with an expected mean fraction of Type 2 AGN of exactly 50%. This 'tilted disc' picture predicts reasonable alignment of observed nuclear structures on average, but with distinct misalignments in individual cases. Initial case studies of the few well resolved objects show that such misalignments are indeed present.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of microarrays in microbial ecology

Microarrays have proven to be a useful and high-throughput method to provide targeted DNA sequence information for up to many thousands of specific genetic regions in a single test. A microarray consists of multiple DNA oligonucleotide probes that, under high stringency conditions, hybridize only to specific complementary nucleic acid sequences (targets). A fluorescent signal indicates the presence and, in many cases, the abundance of genetic regions of interest. In this chapter we will look at how microarrays are used in microbial ecology, especially with the recent increase in microbial community DNA sequence data. Of particular interest to microbial ecologists, phylogenetic microarrays are used for the analysis of phylotypes in a community and functional gene arrays are used for the analysis of functional genes, and, by inference, phylotypes in environmental samples. A phylogenetic microarray that has been developed by the Andersen laboratory, the PhyloChip, will be discussed as an example of a microarray that targets the known diversity within the 16S rRNA gene to determine microbial community composition. Using multiple, confirmatory probes to increase the confidence of detection and a mismatch probe for every perfect match probe to minimize the effect of cross-hybridization by non-target regions, the PhyloChip is able to simultaneously identify any of thousands of taxa present in an environmental sample. The PhyloChip is shown to reveal greater diversity within a community than rRNA gene sequencing due to the placement of the entire gene product on the microarray compared with the analysis of up to thousands of individual molecules by traditional sequencing methods. A functional gene array that has been developed by the Zhou laboratory, the GeoChip, will be discussed as an example of a microarray that dynamically identifies functional activities of multiple members within a community. The recent version of GeoChip contains more than 24,000 50mer oligonucleotide probes and covers more than 10,000 gene sequences in 150 gene categories involved in carbon, nitrogen, sulfur, and phosphorus cycling, metal resistance and reduction, and organic contaminant degradation. GeoChip can be used as a generic tool for microbial community analysis, and also link microbial community structure to ecosystem functioning. Examples of the application of both arrays in different environmental samples will be described in the two subsequent sections.

54 ENVIRONMENTAL SCIENCES↗

The stacked thermal Sunyaev–Zel’Dovich signal of locally brightest galaxies in Planck full mission data: Evidence for galaxy feedback?

We use the Planck full mission temperature maps to examine the stacked thermal Sunyaev–Zel’dovich (tSZ) signal of 188,042 “locally brightest galaxies” (LBGs) selected from the Sloan Digital Sky Survey Data Release 7. Our LBG sample closely matches that of Planck Collaboration XI (PCXI), but our analysis differs in several ways. We work directly in terms of physically observable quantities, requiring minimal assumptions about the gas pressure profile. We explicitly model the dust emission from each LBG and simultaneously measure both the stacked tSZ and dust signals as a function of stellar mass M{sub ∗}. There is a small residual bias in stacked tSZ measurements; we measure this bias and subtract it from our results, finding that the effects are non-negligible at the lowest masses in the LBG sample. Finally, we compare our measurements with two pressure profile models, finding that the profile from Battaglia et al. provides a better fit to the results than the Arnaud et al. “universal pressure profile.” However, within the uncertainties, we find that the data are consistent with a self-similar scaling with mass—more precise measurements are needed to detect the relatively small deviations from self-similarity predicted by these models. Consistent with PCXI, we measure the stacked tSZ signal from LBGs with stellar masses down to log{sub 10}(M{sub ∗}/M{sub ⊙}) ∼ 11.1–11.3. For lower stellar masses, however, we do not see evidence for a stacked tSZ signal. We note that the stacked dust emission is comparable to, or larger than, the stacked tSZ signal for log{sub 10}(M{sub ∗}/M{sub ⊙})≲11.3. Future tSZ analyses with larger samples and lower noise levels should be able to probe deviations from self-similarity and thus provide constraints on models of feedback and the evolution of hot halo gas over cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Mars sample return through parking orbit

A Mars surface sample return mission using Mars direct entry and Mars parking orbit return is described. The mission is designed for a minimum energy requirement and is relatively simple in comparison to the alternative Mars orbital rendezvous mode. The design calls for minimal science, and uses a single Titan IIIE/Centaur launch vehicle. The primary science areas included are biology, biochemistry, geochemistry, and petrology, for detecting life, age dating, and determining chemical compositions and rock types. The total minimum sample requirement would be 30 g. Sampling conditions and recommended measurements are discussed. Maximum use of hardware and experience from the Mariner, Pioneer, and Viking missions is contemplated. The profile for a 1979 conjunction-class mission would include a total time of 1025 days, including one year in Mars parking orbit after sampling. The lander structure, components, and recovery alternatives are explained.

Weaver, W. L.↗

Fatigue performance of laser powder bed fusion hydride-dehydride Ti-6Al-4V powder

We report hydride-dehydride (HDH) Ti-6Al-4V alloy with particle size distribution of 50–120 µm is laser powder bed fusion (L-PBF) processed using optimum processing parameters and a near-fully dense structure with a density of 99.9 % is achieved. Microstructural observations and phase analyses indicate formation of columnar β grains with acicular α/α' phases in as-built condition. The roughness of the as-fabricated samples is significant with an average roughness of R a = 15.71 ± 3.96 µm and a root mean square roughness of R rms = 108.4 ± 24.9 µm, however, both values are reduced to R a = 0.19 ± 0.04 µm and R rms = 4.9 ± 0.6 µm after mechanical grinding. Mechanical tests are carried out on as-fabricated specimens followed by stress relief treatment. All samples are tested to failure in fatigue, under fully-reversed tension-compression conditions of R = –1. The as-built samples failed from the surface with crack initiation mainly at micro-notches, whereas after mechanically grinding, crack initiation changed to subsurface defects such as pores. Minimizing surface roughness by mechanically grinding eliminates surface micro-notches which improves fatigue strength in the high cycle fatigue region. Fatigue notch factor calculations showed that the effect of surface roughness was significantly lower when HDH powder is used compared to standard spherical powder. X-ray diffraction analysis revealed an in-plane compressive stress, micro-strain and grain refinement on the surface of the mechanically ground samples. Fractography observations (macroscale) revealed a fully brittle fracture in the first stage of crack growth with a transition to a dominantly ductile fracture in the third stage of crack growth. On the other hand, at the micro scale, even the brittle fracture regions showed evidence of ductile fracture within the α' martensite laths.

36 MATERIALS SCIENCE↗

Comet nucleus sample return mission

A comet nucleus sample return mission in terms of its relevant science objectives, candidate mission concepts, key design/technology requirements, and programmatic issues is discussed. The primary objective was to collect a sample of undisturbed comet material from beneath the surface of an active comet and to preserve its chemical and, if possible, its physical integrity and return it to Earth in a minimally altered state. The secondary objectives are to: (1) characterize the comet to a level consistent with a rendezvous mission; (2) monitor the comet dynamics through perihelion and aphelion with a long lived lander; and (3) determine the subsurface properties of the nucleus in an area local to the sampled core. A set of candidate comets is discussed. The hazards which the spacecraft would encounter in the vicinity of the comet are also discussed. The encounter strategy, the sampling hardware, the thermal control of the pristine comet material during the return to Earth, and the flight performance of various spacecraft systems and the cost estimates of such a mission are presented.

Source record↗

On the variability of the Priestley‐Taylor coefficient over water bodies

Abstract Deviations in the Priestley‐Taylor (PT) coefficient α PT from its accepted 1.26 value are analyzed over large lakes, reservoirs, and wetlands where stomatal or soil controls are minimal or absent. The data sets feature wide variations in water body sizes and climatic conditions. Neither surface temperature nor sensible heat flux variations alone, which proved successful in characterizing α PT variations over some crops, explain measured deviations in α PT over water. It is shown that the relative transport efficiency of turbulent heat and water vapor is key to explaining variations in α PT over water surfaces, thereby offering a new perspective over the concept of minimal advection or entrainment introduced by PT. Methods that allow the determination of α PT based on low‐frequency sampling (i.e., 0.1 Hz) are then developed and tested, which are usable with standard meteorological sensors that filter some but not all turbulent fluctuations. Using approximations to the Gram determinant inequality, the relative transport efficiency is derived as a function of the correlation coefficient between temperature and water vapor concentration fluctuations ( R Tq ). The proposed approach reasonably explains the measured deviations from the conventional α PT = 1.26 value even when R Tq is determined from air temperature and water vapor concentration time series that are Gaussian‐filtered and subsampled to a cutoff frequency of 0.1 Hz. Because over water bodies, R Tq deviations from unity are often associated with advection and/or entrainment, linkages between α PT and R Tq offer both a diagnostic approach to assess their significance and a prognostic approach to correct the 1.26 value when using routine meteorological measurements of temperature and humidity.

Assouline, Shmuel↗