Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Direct analysis of organic priority pollutants by IMS

Many routine methods for monitoring of trace amounts of atmospheric organic pollutants consist of several steps. Typical steps are: (1) collection of the air sample; (2) trapping of organics from the sample; (3) extraction of the trapped organics; and (4) identification of the organics in the extract by GC (gas chromatography), HPLC (High Performance Liquid Chromatography), or MS (Mass Spectrometry). These methods are often cumbersome and time consuming. A simple and fast method for monitoring atmospheric organics using an IMS (Ion Mobility Spectrometer) is proposed. This method has a short sampling time and does not require extraction of the organics since the sample is placed directly in the IMS. The purpose of this study was to determine the responses in the IMS to organic 'priority pollutants'. Priority pollutants including representative polycyclic aromatic hydrocarbons (PAHs), phthalates, phenols, chlorinated pesticides, and polychlorinated biphenyls (PCB's) were analyzed in both the positive and negative detection mode at ambient atmospheric pressure. Detection mode and amount detected are presented.

Giam, C. S.↗

Polarization Sensing in Digital Holographic Microscopy

Digital holographic microscopy is well suited to the search for microbial species due in part to its intrinsic stability, volumetric imaging capability, and sensitivity to very dilute samples. This is all done with a system having no moving parts, making it additionally attractive for flight instrumentation. Our devices have been field tested on several occasions, and have demonstrated robustness to extreme conditions. When bacteria are alive and moving, they are easy to detect. However, some measurements are subtler. Can we distinguish between a live yet nonmotile species and a mineral, for instance? To provide another method of discrimination, we have added the ability to measure object polarization. This will allow us to characterize the sample by polarization state without any sacrifice in the spatial or temporal resolution (< 1um at 15 Hz). This snapshot polarization sensing is a new method for characterizing the sample under test. In this paper, we will describe the instrument design, the laboratory tests, and demonstrate its performance with live bacteria and crystalline samples.

Wallace, James↗

An Experimental and Predictive Study of Bent-Chamber Acoustic Liners

Acoustic liner samples with rectangular, sharp chamber bends are 3D-printed and tested in the NASA Normal Incidence Tube. The angle of the bend is varied from 0 to 180 degrees. Four different methods are used to predict the impedance behavior of these samples: (1) midline-length assumption, (2) Cummings correction for curved duct bends, (3) Cummings prediction for 180 degrees sharp duct bends, and (4) Helmholtz equation via finite element method. Trends in the experimental data are discussed, predictions are compared to the experimental data, and recommendations are made on prediction method usage. Follow-on work is suggested, including capturing additional test points at higher frequencies and with different chamber geometries. Future modeling strategies are also briefly described.

chamber↗

Effects of processing and prolonged high temperature exposure on the microstructure of Nb-1Zr-C sheet

High temperature stability of the microstructure of Nb-1Zr sheet containing 0.1 and 0.06 wt. percent C was studied as affected by processing and prolonged 1350 K exposure with and without applied stress. Sheets were fabricated by cold rolling bars that were single-, double-, or triple-extruded at 1900 K. Creep samples were double-annealed (1 h at 1755 K + 2 h at 1475 K) prior to testing at 1350 K and 10,000 - 34,500 h. The microstructures of the as-cast, extruded, rolled, DA, and crept samples were characterized using various metallographic and analytical methods. The precipitates were rather coarse Nb2C initially, but transformed to finer (less than or equal to 1 micron) carbides of (Zr, Nb)C with each subsequent high temperature process. The grain size, and the relative amount and morphology of (Zr, Nb)C were found to be affected by the number of extrusions and to some extent by C-content. However, the microstructures of all the crept samples were similar with (Zr, Nb)C distributed throughout the matrix indicating that prolonged exposure to 1350 K gave rise to complete transformation of Nb2C to (Zr, Nb)C regardless of the processing history. These and other observations are presented with the emphasis on the correlation between processing, microstructure, and creep properties.

Uz, Mehmet↗

Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-102 at the Conclusion of 5A.1

The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.

James, John T.↗

Measurement of Creep Properties of Ultra-High-Temperature Materials by a Novel Non-Contact Technique

A non-contact technique for measuring the creep properties of materials has been developed and validated as part of a collaboration among the University of Massachusetts, NASA Marshall Space Flight Center Electrostatic Levitation Facility (ESL), and the University of Tennessee. This novel method has several advantages over conventional creep testing. The sample is deformed by the centripetal acceleration from the rapid rotation, and the deformed shapes are analyzed to determine the strain. Since there is no contact with grips, there is no theoretical maximum temperature and no concern about chemical compatibility. Materials may be tested at the service temperature even for extreme environments such as rocket nozzles, or above the service temperature for accelerated testing of materials for applications such as jet engines or turbopumps for liquid-fueled engines. The creep measurements have been demonstrated to 2400 C with niobium, while the test facility, the NASA MSFC ESL, has processed materials up to 3400 C. Furthermore, the ESL creep method employs a distribution of stress to determine the stress exponent from a single test, versus the many tests required by conventional methods. Determination of the stress exponent from the ESL creep tests requires very precise measurement of the surface shape of the deformed sample for comparison to deformations predicted by finite element models for different stress exponents. An error analysis shows that the stress exponent can be determined to about 1% accuracy with the current methods and apparatus. The creep properties of single-crystal niobium at 1985 C showed excellent agreement with conventional tests performed according to ASTM Standard E-139. Tests on other metals, ceramics, and composites relevant to rocket propulsion and turbine engines are underway.

Hyers, Robert W.↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

Conductivity of materials made of aluminum nitride and silicon nitride mixtures

To establish the possible mechanism for conductivity in aluminum nitride a study was made of the electric conductivity of pure AlN and its mixtures with silicon nitride at different temperatures and partial pressures of nitrogen in the gas phase. The thermoelectromotive force was also measured. The experiments used polycrystalline samples of cylindrical shape 18 mm in diameter made of powders by hot pressing in graphite press molds at a temperature of 1973-2273 K and pressure 1,470,000 n/sqm. The items obtained by this method had porosity not over 5%. After pressing, the samples were machined to remove carbon from the surface, and were annealed in a stream of dry ammonia for 10 h at a temperature of 1273-1373 K. Electric conductivity was measured according to the bridge scheme on an alternating current of frequency 10 kHz. In order to guarantee close contact of the platinum electrodes with the surface of the samples, a thin layer of platinum was sprayed on them. Experiments were conducted in the temperature interval 1273-1573 K with a half hour delay at each assigned temperature with heating and cooling.

Gorbatov, A. G.↗

STS 119 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-119) and International Space Station (15A)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 106, 106, and 101 %,respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

Developing lake sampling strategies with existing Landsat data

On the basis of the assumptions that Landsat image densities relate to water quality, that lake densities can be modeled, and that homogeneous water quality areas can therefore be predicted, a method is developed for the selection of optimum water quality sampling locations on Oneida Lake in central New York. Patterns of Oneida Lake density on 24 Landsat band 5 images were traced from the screen of a density slicer, and the lake was gridded into 161 1.25 X 1.25-km cells, with image density levels encoded for each cell. Cell density levels were then employed as the dependent variable in correlations and multiple regression equations with degree days, resultant wind speed, and resultant direction. Cell density levels were averaged over two-week periods, and the averages were correlated with water quality measurements.

Philipson, W. R.↗

Grain size analysis and high frequency electrical properties of Apollo 15 and 16 samples

The particle size distribution of eleven surface fines samples collected by Apollo 15 and 16 was determined by the method of measuring the sedimentation rate in a column of water. The fact that the grain size distribution in the core samples shows significant differences within a few centimeters variation of depth is important for the understanding of the surface transportation processes which are responsible for the deposition of thin layers of different physical and/or chemical origin. The variation with density of the absorption length is plotted, and results would indicate that for the case of meter wavelength radar waves, reflections from depths of more than 100 meters generally contribute significantly to the radar echoes obtained.

Gold, T.↗

Raman Spectroscopy for Mineral Identification and Quantification for in situ Planetary Surface Analysis: A Point Count Method

Quantification of mineral proportions in rocks and soils by Raman spectroscopy on a planetary surface is best done by taking many narrow-beam spectra from different locations on the rock or soil, with each spectrum yielding peaks from only one or two minerals. The proportion of each mineral in the rock or soil can then be determined from the fraction of the spectra that contain its peaks, in analogy with the standard petrographic technique of point counting. The method can also be used for nondestructive laboratory characterization of rock samples. Although Raman peaks for different minerals seldom overlap each other, it is impractical to obtain proportions of constituent minerals by Raman spectroscopy through analysis of peak intensities in a spectrum obtained by broad-beam sensing of a representative area of the target material. That is because the Raman signal strength produced by a mineral in a rock or soil is not related in a simple way through the Raman scattering cross section of that mineral to its proportion in the rock, and the signal-to-noise ratio of a Raman spectrum is poor when a sample is stimulated by a low-power laser beam of broad diameter. Results obtained by the Raman point-count method are demonstrated for a lunar thin section (14161,7062) and a rock fragment (15273,7039). Major minerals (plagioclase and pyroxene), minor minerals (cristobalite and K-feldspar), and accessory minerals (whitlockite, apatite, and baddeleyite) were easily identified. Identification of the rock types, KREEP basalt or melt rock, from the 100-location spectra was straightforward.

Haskin, Larry A.↗

Live/Dead Bacterial Spore Assay Using DPA-Triggered Tb Luminescence

A method of measuring the fraction of bacterial spores in a sample that remain viable exploits DPA-triggered luminescence of Tb(3+) and is based partly on the same principles as those described earlier. Unlike prior methods for performing such live/dead assays of bacterial spores, this method does not involve counting colonies formed by cultivation (which can take days), or counting of spores under a microscope, and works whether or not bacterial spores are attached to other small particles (i.e., dust), and can be implemented on a time scale of about 20 minutes.

Ponce, Adrian↗

Development of Ion Mobility Spectrometry for Exobiology Flight Experiments

Ion Mobility Spectrometry (IMS) can provide gas chromatography with sample identification independent of sample retention time, with minimal interface. Initial commercial methods of IMS however, did not possess sufficient analytical capabilities and presented operational parameters which were unsuitable for exobiology missions. Subsequent development of IMS technology, with the focus on exobiology analytical requirements and mission imposed operational limitations, has produced an IMS interfaced with a GC capable of fulfilling the analytical requirements of several exobiology missions. Future exobiology missions will require further development of the IMS, particularly in the areas of overall instrument miniaturization and complex sample identification. The evolution of the exobiology focused IMS will be presented up to the current prototype design, which is a component of several proposed exobiology instruments. Areas of future development will also be discussed.

Kojiro, Daniel R.↗

STS 132 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-132) and International Space Station (ULF4)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (13C-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 93, 85%, and 88%, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 7 GSCs from the ISS is also shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 78, 96 and 90%, respectively. Recovery from formaldehyde control badges ranged from 90 to 112%.

James. John T.↗

A sample holding technique for study of crystal growth in silicate melts

A thin platinum wire loop is an effective way to hold silicate melts during experimentation in a gas-mixing furnace. This method results in a minimum of physical and chemical interaction between the sample and container but maximum interaction between sample and gas mixture. However, volatilization of sodium occurs while the silicate is molten. By minimizing the chance of heterogeneous nucleation, the method is ideal for experimental investigation of the origin of rock textures.

Donaldson, C. H.↗

Geostatistical Approaches for Spatial Estimation of Vegetation Quantities Using Ground and Image Data

A major challenge in the study of the earth system is the mapping of vegetation quantities over large regions. Geostatistical methods, such as cokriging and stochastic simulation, have the potential to exploit more fully both remotely sensed data and ground information and improve the spatial estimation of vegetation variables over traditional regression methods. A synthetic example constructed from imaging spectrometer data allows a useful comparison among regression, cokriging and a simple probability-field method. A range of linear relationships between direct (sampled) and ancillary images is used. The lowest root-mean-square-error is achieved with cokriging until the correlation between direct and ancillary data exceeds .89, at which point regression is the superior estimator. Probability-field simulation gives a range of possible realizations, most more precise than those from regression. The relationship between ground measurements and image data is thus demonstrated to be one of the critical factors in the choice of a spatial estimation method.

Dungan, Jennifer L.↗