Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Broadband Photoconductive Sampling in Gallium Phosphide

Abstract Direct measurements of the electric field of light enable new observations of light–matter interactions. In the near‐infrared and visible spectral ranges, this typically relies on techniques that exploit nonlinearities in gases or solids, which limits their sensitivity. Here, a method for the detection of broadband near‐infrared fields spanning more than one octave from 110 to 220 THz based on linear absorption in a semiconductor is demonstrated. This technique, which avoids complex vacuum setups and works under ambient conditions, employs linear photoconductive sampling (LPS) in gallium phosphide. Simulations reveal that the response function of LPS is concerned with the intensity envelope of the gate field, in contrast to electro‐optic sampling, relaxing the stringent temporal requirements on the gate pulse.

36 MATERIALS SCIENCE↗

Distinguishing Unfolding and Functional Conformational Transitions of Calmodulin Using Ultraviolet Resonance Raman Spectroscopy

Calmodulin (CaM) is a ubiquitous moderator protein for calcium signaling in all eukaryotic cells. This small calcium-binding protein exhibits a broad range of structural transitions, including domain opening and folding-unfolding, that allow it to recognize a wide variety of binding partners in vivo. While the static structures of CaM associated with its various binding activities are fairly well known, it has been challenging to examine the dynamics of transition between these structures in real-time, due to a lack of suitable spectroscopic probes of CaM structure. In this paper, we examine the potential of ultraviolet resonance Raman (UVRR) spectroscopy for clarifying the nature of structural transitions in CaM. We find that the UVRR spectral change (with 229 nm excitation) due to thermal unfolding of CaM is qualitatively different from that associated with opening of the C-terminal domain in response to Ca2+ binding. This spectral difference is entirely due to differences in teritary contacts at the inter-domain tyrosine residue Tyr138, toward which other spectroscopic methods are not sensitive. We conclude that UVRR is ideally suited to identifying the different types of structural transitions in CaM and other proteins with conformation-sensitive tyrosine residues, opening a path to time-resolved studies of CaM dynamics using Raman spectroscopy.

Jones, Eric M.↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Singularity variables for missing energy event kinematics

We discuss singularity variables which are properly suited for analyzing the kinematics of events with missing transverse energy at the LHC. We consider six of the simplest event topologies encountered in studies of leptonic W-bosons and top quarks, as well as in SUSY-like searches for new physics with dark matter particles. In each case, we illustrate the general prescription for finding the relevant singularity variable, which in turn helps delineate the visible parameter subspace on which the singularities are located. Our results can be used in two different ways — first, as a guide for targeting the signal-rich regions of parameter space during the stage of discovery, and second, as a sensitive focus point method for measuring the particle mass spectrum after the initial discovery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Whole-Body Magnetic Resonance Angiography at 3 Tesla Using a Hybrid Protocol in Patients with Peripheral Arterial Disease

The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as well as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control of Additively Manufactured Metallic Structures with Machine Learning of Thermography Images

Additive manufacturing (AM) of high-strength metals is currently based on the laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Quality control (QC) requires nondestructive evaluation of actual AM structures. Flash thermography is a potentially promising QC technique because it is scalable to arbitrary structure size. However, the detection sensitivity of this method is limited by noise. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatial–temporal blind source separation and spatial–temporal sparse dictionary learning methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced by the LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, the ML methods with higher accuracy require a longer runtime. However, this runtime is sufficiently short to perform QC within a realistic time frame.

36 MATERIALS SCIENCE↗

Apoferritin Protein Nanoparticles Dually labeled with Aptamer and Horseradish Peroxidase as a Sensing Probe for Thrombin Detection

A sandwich-type electrochemical aptasensor has been developed for the detection of thrombin, based on dual signal-amplification using HRP and apoferritin. Aptamer1 (Apt1) loaded on core/shell Fe3O4/Au magnetic nanoparticle (AuMNP) was used as recognition elements, and apoferritin dually labeled with Aptamer2 (Apt2) and HRP was used as a detection probe. Sandwich-type complex, Apt1/thrombin/Apt2–apoferritin NPs–HRP was formed by the affinity reactions between AuMNPs–Apt1, thrombin, and Apt2–apoferritin–HRP. The complex was anchored on a screen-printed carbon electrode (SPCE). Differential pulse voltammetry (DPV) was used to monitor the electrode response. The proposed aptasensor yielded a linear current response to thrombin concentrations over a broad range of 0.5 pM to 100 pM with a detection limit of 0.07 pM (S/N = 3). The detection signal was amplified by using apoferritin and HRP. This nanoparticle-based aptasensor offers a new method for rapid, sensitive, selective, and inexpensive quantification of thrombin, and offers a promising potential in biomarker detection and disease diagnosis. --------------------------------------------------------------------------------

aptmer↗

Preparation, characterization of Fe3O4 at TiO2 magnetic nanoparticles and their application for immunoassay of biomarker of exposure to organophosphorus pesticides

Novel Fe3O4 at TiO2 magnetic nanoparticles were prepared and developed for a new nanoparticle-based immunosensor for electrochemical quantification of organophosphorylated butyrylcholinesterase (BChE) in plasma, a specific biomarker of exposure to organophosphorus (OP) agents. The Fe3O4 at TiO2 nanoparticles were synthesized by hydrolysis of tetrabutyltitanate on the surface of Fe3O4 magnetic nanospheres, and characterized by attenuated total reflection Fourier-transform infrared spectra, transmission electron microscope and X-ray diffraction. The functional Fe3O4 at TiO2 nanoparticles were performed as capture antibody to selectively enrich phosphorylated moiety instead of phosphoserine antibody in the traditional sandwich immunoassays. The secondary recognition was served by quantum dots (QDs)-tagged anti-BChE antibody (QDs-anti-BChE). With the help of a magnet, the resulting sandwich-like complex, Fe3O4 at TiO2/OP-BChE/QDs-anti-BChE, was easily isolated from sample solutions and the released cadmium ions were detected on a disposable screen-printed electrode (SPE). The binding affinities were investigated by both surface plasmon resonance (SPR) and square wave voltammetry (SWV). This method not only avoids the drawback of unavailability of commercial OP-specific antibody but also amplifies detection signal by QDs-tags together with easy separation of samples by magnetic forces. The proposed immunosensor yields a linear response over a broad OP-BChE concentrations range from 0.02 to 10 nM, with detection limit of 0.01 nM. Moreover, the disposable nanoparticle-based immunosensor has been validated with human plasma samples. It offers a new method for rapid, sensitive, selective and inexpensive screening/evaluating exposure to OP pesticides.

biomarker↗

A new probe of μ Hz gravitational waves with FRB timing

We propose Fast Radio Burst (FRB) timing, which uses the precision measurements of the arrival time differences of repeated FRB signals along multiple sightlines, as a new probe of gravitational waves (GWs) around nHz to μHz frequencies, with the highest frequency limited by FRB repeating period. The anticipated experiment requires a sightline separation of tens of AU, achieved by sending radio telescopes to space. We find the signal of arrival time difference induced by GWs depends only on the local GWs in the solar system and we can correlate the measurements from different FRB sources or the same source with different repeaters, which leads to a better sensitivity with a larger number of FRB repeaters detected. Here, the projected sensitivity shows this method is a competitive probe in the nHz to μ Hz frequency range. It can fill the 'μHz gap' between pulsar timing arrays and Laser Interferometer Space Antenna (LISA) and is complementary to other proposals of GW detection in this frequency band.

79 ASTRONOMY AND ASTROPHYSICS↗

Cell-Type-Specific Profiling of Gene Expression and Chromatin Binding without Cell Isolation: Assaying RNA Pol II Occupancy in Neural Stem Cells

Cell-type-specific transcriptional profiling often requires the isolation of specific cell types from complex tissues. We have developed ‘‘TaDa,’’ a technique that enables cell-specific profiling without cell isolation. TaDa permits genome-wide profiling of DNA- or chromatin-binding proteins without cell sorting, fixation, or affinity purification. The method is simple, sensitive, highly reproducible, and transferable to any model system. We show that TaDa can be used to identify transcribed genes in a celltype-specific manner with considerable temporal precision, enabling the identification of differential gene expression between neuroblasts and the neuroepithelial cells from which they derive. We profile the genome-wide binding of RNA polymerase II in these adjacent, clonally related stem cells within intact Drosophila brains. Our data reveal expression of specific metabolic genes in neuroepithelial cells, but not in neuroblasts, and highlight gene regulatory networks that may pattern neural stem cell fates.

59 BASIC BIOLOGICAL SCIENCES↗

Nephrotoxicity of uranium in drinking water from private drilled wells

Objectives: To investigate the association between uranium in drinking water from drilled wells and aspects of kidney function measured by sensitive urine tests. Methods: Three hundred and one of 398 eligible subjects (75.6%) aged 18-74 years with daily drinking water supplies from private drilled wells located in uranium-rich bedrock (exposed group) volunteered to participate along with 153 of 271 local controls (56.4%) who used municipal water. Participants responded to a questionnaire on their water consumption and general health, and provided a morning urine sample and drinking water for analysis. Results: The uranium content of well water samples (n=153) varied considerably (range <0.20-470 {mu}g/l, median 6.7 {mu}g/l, 5% >100 {mu}g/l), while uranium levels in all samples of municipal water (n=14) were below the limit of quantification (0.2 {mu}g/l). Urinary levels of uranium were more than eight times higher in exposed subjects than in controls (geometric means 38 and 4.3 ng/l, respectively; p<0.001), but their mean urine lead levels were not significantly different. There was a strong curvilinear correlation between uranium in drinking water and in urine (r{sup 2}=0.66). Levels of albumin, {beta}{sub 2}-microglobulin, protein HC as well as kappa and lambda immunoglobulin chains in urine from exposed and controls were similar. The N-acetyl-{beta}-D-glucosaminidase (NAG) activity was significantly lower in the exposed group vs. controls, possibly secondary to differential storage duration of samples from the two groups. Even in regression models adjusting for gender, age and smoking no association of uranium in water and the kidney function parameters was observed. Using uranium in urine in the entire study group as a marker of exposure, however, a tendency of exposure-related increases of {beta}{sub 2}-microglobulin, protein HC and kappa chains were noted. This tendency was enhanced after exclusion of subjects with diabetes mellitus from the analysis. Conclusions: Uranium levels in urine were strongly correlated to levels in drinking water from drilled wells. There were no clear signs of nephrotoxicity from uranium in drinking water at levels recorded in this study, but some indications of an effect were observed using uranium in urine as a measure of overall uranium exposure. The clinical relevance of these findings remains unclear.

60 APPLIED LIFE SCIENCES↗

Biomass-derived carbon dots as emerging visual platforms for fluorescent sensing

Biomass-derived carbon dots (CDs) are non-toxic and fluorescently stable, making them suitable for extensive application in fluorescence sensing. The use of cheap and renewable materials not only improves the utilization rate of waste resources, but it is also drawing increasing attention to and interest in the production of biomass-derived CDs. Visual fluorescence detection based on CDs is the focus of current research. This method offers high sensitivity and accuracy and can be used for rapid and accurate determination under complex conditions. Here, this paper describes the biomass precursors of CDs, including plants, animal remains and microorganisms. The factors affecting the use of CDs as fluorescent probes are also discussed, and a brief overview of enhancements made to the preparation process of CDs is provided. In addition, the application prospects and challenges related to biomass-derived CDs are demonstrated.

54 ENVIRONMENTAL SCIENCES↗

The impacts of convex piecewise linear cost formulations on AC optimal power flow

Despite strong connections through shared application areas, research efforts on power market optimization (e.g., unit commitment) and power network optimization (e.g., optimal power flow) remain largely independent. A notable illustration of this is the treatment of power generation cost functions, where nonlinear network optimization has largely used polynomial representations and market optimization has adopted piecewise linear encodings. This work combines state-of-the-art results from both lines of research to understand the best mathematical formulations of the nonlinear AC optimal power flow problem with piecewise linear generation cost functions. An extensive numerical analysis of non-convex models, linear approximations, and convex relaxations across fifty-four realistic test cases illustrates that nonlinear optimization methods are surprisingly sensitive to the mathematical formulation of piecewise linear functions. The results indicate that a poor formulation choice can slow down algorithm performance by a factor of ten, increasing the runtime from seconds to minutes. Furthermore, these results provide valuable insights into the best formulations of nonlinear optimal power flow problems with piecewise linear cost functions, an important step towards building a new generation of energy markets that incorporate the nonlinear AC power flow model.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of trichloroacetimidate-mediated benzylation to the detection of pinacolyl methylphosphonic acid in standardised proficiency test matrices

Here, a procedure for the qualitative analysis of pinacolyl methylphosphonic acid (PMPA), a degradation product from the nerve agent Soman (GD), is presented. The protocol involves the derivatization of PMPA with benzyl trichloroacetimidate resulting in its benzylation under neutral conditions, a desirable attribute in the presence of other base-sensitive analytes. The method was found to perform well in the detection of this Schedule 2 chemical, spiked at low concentrations, in three different test matrices, two soils and one liquid, featured in different Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests.

Chemistry↗

Small Bowel Dose Parameters Predicting Grade ≥3 Acute Toxicity in Rectal Cancer Patients Treated With Neoadjuvant Chemoradiation: An Independent Validation Study Comparing Peritoneal Space Versus Small Bowel Loop Contouring Techniques

Purpose: To determine whether volumes based on contours of the peritoneal space can be used instead of individual small bowel loops to predict for grade ≥3 acute small bowel toxicity in patients with rectal cancer treated with neoadjuvant chemoradiation therapy. Methods and Materials: A standardized contouring method was developed for the peritoneal space and retrospectively applied to the radiation treatment plans of 67 patients treated with neoadjuvant chemoradiation therapy for rectal cancer. Dose-volume histogram (DVH) data were extracted and analyzed against patient toxicity. Receiver operating characteristic analysis and logistic regression were carried out for both contouring methods. Results: Grade ≥3 small bowel toxicity occurred in 16% (11/67) of patients in the study. A highly significant dose-volume relationship between small bowel irradiation and acute small bowel toxicity was supported by the use of both small bowel loop and peritoneal space contouring techniques. Receiver operating characteristic analysis demonstrated that, for both contouring methods, the greatest sensitivity for predicting toxicity was associated with the volume receiving between 15 and 25 Gy. Conclusion: DVH analysis of peritoneal space volumes accurately predicts grade ≥3 small bowel toxicity in patients with rectal cancer receiving neoadjuvant chemoradiation therapy, suggesting that the contours of the peritoneal space provide a reasonable surrogate for the contours of individual small bowel loops. The study finds that a small bowel V15 less than 275 cc and a peritoneal space V15 less than 830 cc are associated with a less than 10% risk of grade ≥3 acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Course Treatment With Gefitinib Enhances Curative Potential of Radiation Therapy in a Mouse Model of Human Non-Small Cell Lung Cancer

Purpose: To evaluate the combination of radiation and an epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) in preclinical models of human non-small cell lung cancer. Methods and Materials: Sensitivity to an EGFR TKI (gefitinib) or radiation was assessed using proliferation assays and clonogenic survival assays. Effects on receptor signal transduction pathways (pEGFR, pAKT, pMAPK) and apoptosis (percentage of cleaved PARP Poly (ADP-ribose) polymerase (PARP)) were assessed by Western blotting. Radiation-induced DNA damage was assessed by γH2AX immunofluorescence. Established (≥100 mm{sup 3}) EGFR-mutated (HCC287) or EGFR wild-type (A549) subcutaneous xenografts were treated with radiation (10 Gy, day 1) or gefitinib (50 mg/kg, orally, on days 1-3) or both. Results: In non-small cell lung cancer (NSCLC) cell lines with activating EGFR mutations (PC9 or HCC827), gefitinib treatment markedly reduced pEGFR, pAKT, and pMAPK levels and was associated with an increase in cleaved PARP but not in γH2AX foci. Radiation treatment increased the mean number of γH2AX foci per cell but did not significantly affect EGFR signaling. In contrast, NSCLC cell lines with EGFR T790M (H1975) or wild-type EGFR (A549) were insensitive to gefitinib treatment. The combination of gefitinib and radiation treatment in cell culture produced additive cell killing with no evidence of synergy. In xenograft models, a short course of gefitinib (3 days) did not significantly increase the activity of radiation treatment in wild-type EGFR (A549) tumors (P=.27), whereas this combination markedly increased the activity of radiation (P<.001) or gefitinib alone (P=.002) in EGFR-mutated HCC827 tumors, producing sustained tumor regressions. Conclusions: Gefitinib treatment increases clonogenic cell killing by radiation but only in cell lines sensitive to gefitinib alone. Our data suggest additive rather than synergistic interactions between gefitinib and radiation and that a combination of short-course gefitinib and high-dose/-fraction radiation may have the greatest potential against the subsets of lung cancers harboring activating mutations in the EGFR gene.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Involvement of Mitochondrial Membrane Potential in Cross-Resistance Between Radiation and Docetaxel

Purpose: To understand the molecular mechanisms underlying cancer cell radioresistance, clinically relevant radioresistant (CRR) cells that continue to proliferate during exposure to 2 Gy/day X-rays for more than 30 days were established. A modified high-density survival assay for anticancer drug screening revealed that CRR cells were resistant to an antimicrotubule agent, docetaxel (DTX). The involvement of reactive oxygen species (ROS) from mitochondria (mtROS) in the cross-resistance to X-rays and DTX was studied. Methods and Materials: Sensitivity to anticancer agents was determined by a modified high-density cell survival or water-soluble tetrazolium salt assay. DTX-induced mtROS generation was determined by MitoSOX red staining. JC-1 staining was used to visualize mitochondrial membrane potential. DTX-induced DNA double-strand breaks were determined by γ-H2AX staining. To obtain mitochondrial DNA-lacking (ρ{sup 0}) cells, the cells were cultured for 3 to 4 weeks in medium containing ethidium bromide. Results: Treatment with DTX increased mtROS in parental cells but not in CRR cells. DTX induced DNA double-strand breaks in parental cells. The mitochondrial membrane potential of CRR cells was lower in CRR cells than in parental cells. Depletion of mtDNA induced DTX resistance in parental cells. Treatment with dimethyl sulfoxide also induced DTX resistance in parental cells. Conclusions: The mitochondrial dysfunction observed in CRR cells contributes to X-ray and DTX cross-resistance. The activation of oxidative phosphorylation in CRR cells may represent an effective approach to overcome radioresistant cancers. In general, the overexpression of β-tubulin or multidrug efflux pumps is thought to be involved in DTX resistance. In the present study, we discovered another DTX resistant mechanism by investigating CRR cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗