Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial Composition Influenced by Solvent in High-Entropy Alloy Nanoparticle Synthesis via Polyol Reduction

The performance of nanoparticles in catalytic reactions depends critically on their surface composition. In a multielemental system, this issue becomes even more important. Here, we report that the choice of solvent in polyol reduction synthesis of high entropy alloy (HEA) nanoparticles can have a subtle but significant influence on the elemental distribution near the surface of individual nanoparticles. Our study reveals that longchain polyethylene glycol typically produces a more uniform multielement distribution within a nanoparticle than short-chain triethylene glycol under identical experimental conditions. We performed electrochemical reduction of metal salts in both solvents to understand the reduction kinetics of metal salts, which shows that a solvent capable of improving the co-reduction of metal salts leads to the synthesis of more homogenized nanoparticles, whereas a solvent with a varying degree of reduction potency will lead to inhomogeneous elemental distribution in an HEA nanoparticle.

Catalyst↗

Influence of the contact potential and space-charge effect on the performance of a Stoffel-Johnson design electron source for inverse photoemission spectroscopy

By imaging the spatial intensity distribution of the electrons from a Stoffel-Johnson (SJ) type low energy electron source for inverse photoemission spectroscopy (IPES), we find that the focus is distorted when the beam current exceeds the limiting value due to space charge effect. The space charge effect and the contact potential difference suppress the beam current at low energies (<10 eV). In this work, we show that these limitations of the SJ source can be overcome by compensation of the contact potential difference between the cathode and the lens electrodes and an uniform well focused electron beam with the set kinetic energy can be obtained. The size of the electron beam is around 1 mm full width at half maximum over the whole energy range of 5 to 30 eV generally used for IPES. The compensation of the contact potential difference also enhances the beam current substantially at low energies (<10 eV) and uniform beam current is achieved for the whole energy range. We find that the drift in the electron beam position is sensitive to the lens electrode separation and it is about 1 mm over the whole energy range. By measuring the n = 1 image potential state on Cu(100), we show that the resolution is better when the cathode filament current is set to lower values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative assessment of selenium diffusion and passivation in CdSeTe solar cells probed by spatially resolved cathodoluminescence

The introduction of selenium in CdSeTe/CdTe solar cells has led to improved device performances attributed to the passivation of bulk defects. In this work, high-resolution cathodoluminescence experiments are performed on a series of CdSeTe/CdTe thin films with different Se concentrations to quantify the mechanisms and the passivation role of Se. We demonstrate a universal dependence between the Se concentration and the radiative efficiency and a ten-fold enhancement of the luminescence between CdTe and CdSe 0.4 Te 0.6 . Raw luminescence maps are converted into maps of the Se concentration, revealing its graded profile within the stack. We demonstrate the diffusion of Se along CdTe grain boundaries induced by the cadmium chloride annealing treatment and determine the diffusion coefficients, which are more than eight times higher at grain boundaries than in grain interiors. These results provide microscopic insights into the distribution of Se and its impact on the passivation of CdSeTe/CdTe solar cells.

14 SOLAR ENERGY↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

Development of a compact tomography camera system using a multianode photomultiplier tube for compact torus experiments

A compact tomography camera system consisting of a photomultiplier tube, a multislit optical system, and a band-pass interference filter has been developed. The viewing area and spatial resolution can be configured by the arrangement of the slit system. The camera system has been specially designed for self-organized compact torus experiments having strong magnetohydrodynamics events with a submicrosecond time-scale. The developed system has been tested on a field-reversed configuration formed by the field-reversed theta-pinch. Performance evaluation of the system has been performed by comparison to the former optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delineating the Impact of Transition‐Metal Crossover on Solid‐Electrolyte Interphase Formation with Ion Mass Spectrometry

Abstract Lithium‐metal batteries (LMB) employing cobalt‐free layered‐oxide cathodes are a sustainable path forward to achieving high energy densities, but these cathodes exhibit substantial transition‐metal dissolution during high‐voltage cycling. While transition‐metal crossover is recognized to disrupt solid‐electrolyte interphase (SEI) formation on graphite anodes, experimental evidence is necessary to demonstrate this for lithium‐metal anodes. In this work, advanced high‐resolution 3D chemical analysis is conducted with time‐of‐flight secondary‐ion mass spectrometry (TOF‐SIMS) to establish spatial correlations between the transition metals and electrolyte decomposition products found on cycled lithium‐metal anodes. Insights into the localization of various chemistries linked to crucial processes that define LMB performance, such as lithium deposition, SEI growth, and transition‐metal deposition are deduced from a precise elemental and spatial analysis of the SEI. Heterogenous transition‐metal deposition is found to perpetuate both heterogeneous SEI growth and lithium deposition on lithium‐metal anodes. These correlations are confirmed across various lithium‐metal anodes that are cycled with different cobalt‐free cathodes and electrolytes. An advanced electrolyte that is stable to higher voltages is shown to minimize transition‐metal crossover and its effects on lithium‐metal anodes. Overall, these results highlight the importance of maintaining uniform SEI coverage on lithium‐metal anodes, which is disrupted by transition‐metal crossover during operation at high voltages.

Chemistry↗

Performance measurements for the PET/CT Discovery-600 using NEMA NU 2-2007 standards

Purpose: The aim of this study was to assess the performance measurements of the new PET/CT system Discovery-600 (D-600, GEMS, Milwaukee, WI). Methods: Performance measures were obtained with the National Electrical Manufacturers Association (NEMA) NU 2-2007 procedures. Results: The transverse (axial) spatial resolution FWHMs were 4.9 (5.6) mm and 5.6 (6.4) mm at 1 and 10 cm off axis, respectively. The sensitivity (average at 0 and 10 cm) was 9.6 cps/kBq. The scatter fraction was 36.6% (low energy threshold: 425 keV). The NEC peak rate (k=1) was 75.2 kcps at 12.9 kBq/cc. The hot contrasts for 10, 13, 17, and 22 mm spheres were 41%, 51%, 62%, and 73% and the cold contrasts for 28 and 37 mm spheres were 68% and 72%. Conclusions: The Discovery-600 has good performance for the NEMA NU 2-2007 parameters, particularly in improved sensitivity compared to the scanners of the same Discovery family, D-ST and D-STE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tusas: A fully implicit parallel approach for coupled phase-field equations

In this study, we develop a fully-coupled, fully-implicit approach for phase-field modeling of solidification in metals and alloys. Predictive simulation of solidification in pure metals and metal alloys remains a significant challenge in the field of materials science, as microstructure formation during the solidification process plays a critical role in the properties and performance of the solid material. Our simulation approach consists of a finite element spatial discretization of the fully-coupled nonlinear system of partial differential equations at the microscale, which is treated implicitly in time with a preconditioned Jacobian-free Newton-Krylov method. The approach is algorithmically scalable as well as efficient due to an effective preconditioning strategy based on algebraic multigrid and block factorization. We implement this approach in the open-source Tusas framework, which is a general, flexible tool developed in C++ for solving coupled systems of nonlinear partial differential equations. The performance of our approach is analyzed in terms of algorithmic scalability and efficiency, while the computational performance of Tusas is presented in terms of parallel scalability and efficiency on emerging heterogeneous architectures. We demonstrate that modern algorithms, discretizations, and computational science, and heterogeneous hardware provide a robust route for predictive phase-field simulation of microstructure evolution during additive manufacturing.

97 MATHEMATICS AND COMPUTING↗

Application of a field-based method to spatially varying thermal transport problems in molecular dynamics

This paper derives a methodology to enable spatial and temporal control of thermally inhomogeneous molecular dynamics (MD) simulations. The primary goal is to perform non-equilibrium MD of thermal transport analogous to continuum solutions of heat flow which have complex initial and boundary conditions, moving MD beyond quasi-equilibrium simulations using periodic boundary conditions. In our paradigm, the entire spatial domain is filled with atoms and overlaid with a finite element (FE) mesh. The representation of continuous variables on this mesh allows fixed temperature and fixed heat flux boundary conditions to be applied, non-equilibrium initial conditions to be imposed and source terms to be added to the atomistic system. In effect, the FE mesh defines a large length scale over which atomic quantities can be locally averaged to derive continuous fields. Unlike coupling methods which require a surrogate model of thermal transport like Fourier's law, in this work the FE grid is only employed for its projection, averaging and interpolation properties. Inherent in this approach is the assumption that MD observables of interest, e.g. temperature, can be mapped to a continuous representation in a non-equilibrium setting. This assumption is taken advantage of to derive a single, unified set of control forces based on Gaussian isokinetic thermostats to regulate the temperature and heat flux locally in the MD. Example problems are used to illustrate potential applications. In addition to the physical results, data relevant to understanding the numerical effects of the method on these systems are also presented.

36 MATERIALS SCIENCE↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Simulating county-level crop yields in the Conterminous United States using the Community Land Model: The effects of optimizing irrigation and fertilization

Representing agricultural systems explicitly in Earth system models is important for understanding the water-energy-food nexus under climate change. In this study, we applied Version 4.5 of the Community Land Model (CLM) at a 0.125 degree resolution to provide the first county-scale validation of the model in simulating crop yields over the Conterminous United States (CONUS). We focused on corn and soybean that are both important grain crops and biofuel feedstocks (corn for bioethanol; soybean for biodiesel). We find that the default model substantially under- or over-estimate yields of corn and soybean as compared to the US Department of Agriculture (USDA) census data, with corresponding county-level root-mean square error (RMSE) of 45.3 Bu/acre and 12.9 Bu/acre, or 42% and 38% of the US mean yields for these crops, respectively. Based on the numerical experiments, the lack of proper representation of agricultural management practices, such as irrigation and fertilization, was identified as a major cause for the model's poor performance. After implementing an irrigation management scheme calibrated against county-level US Geological Survey (USGS) census data, the county-level RMSE for corn yields reduced to 42.6 Bu/acre. We then incorporated an optimized fertilizer scheme in rate and timing, which is achieved by the constraining annual total fertilizer amount against the USDA data, considering the dynamics between fertilizer demand and supply and adopting a calibrated fertilizer scheduling map. The proposed approach is shown to be effective in increasing the fertilizer use efficiency for corn yields, with county-level RMSE reduced to 23.8 Bu/acre (or 22% of the US mean yield). In regions with similar annual fertilizer applied as in the default, the improvements in corn yield simulations are mainly attributed to application of longer fertilization periods and consideration of the dynamics between fertilizer demand and supply. For soybean which is capable of fixing nitrogen to meet nitrogen demand, the reduced positive bias to 6.9 Bu/acre (or 21% of the country mean) was mainly attributed to consideration of the dynamic interactions between fertilizer demand and supply. Although large bias remains in terms of the spatial pattern (i.e. high county-level RMSE), mainly due to limited performance over the Western US, our results show that optimizing irrigation and fertilization can lead to promising improvement in crop and soybean yield simulations in terms of the mean and variability especially over the Mid-west corn belt, and subsequent evapotranspiration (ET) estimates. Finally, this study demonstrates the CLM4.5 capability for predicting crop yields and their interactions with climate, and highlights the value of continued model improvements and development to understand biogeophysical and biogeochemical impacts of land use and land cover change using an Earth system modeling framework.

54 ENVIRONMENTAL SCIENCES↗

MCNP6 Study of Spatial Fidelity Required for ROC Curve Convergence

The detection of special nuclear material at ports and borders is one of the primary missions of the Department of Homeland Security's (DHS) Domestic Nuclear Detection Office (DNDO). In support of this mission a large-scale modeling and simulation effort has been undertaken with the goal of providing a comprehensive tool-kit that addresses the complexity of problems involved with developing and maintaining technologies deployed to global nuclear detection architecture (GNDA) nodes. An important objective of DNDO's mission is to characterize detector system performance before deployment. In the effort to support this mission, the latest version of MCNP has been used to perform detectability studies of highly enriched uranium (HEU) to populate a database that will be used for the tool-kit. The characterization method used in the implementation of the database is the receiver operating characteristic (ROC). A ROC curve shows the limits of detectability of a given system as well as an overall metric of the efficacy of a detection system. This is accomplished by comparing total detector count distributions to the count distribution produced by background alone. For an in-depth explanation of the theory behind the MCNP production of ROC curves please refer to the paper, 'How To Use The Receiver Operating Characteristic Tally Option in MCNP6'. Building a useful database requires an expansive parameter space. The current tool-kit use nine parameters, which if varied with just 5 options each, results in nearly two million simulations to run. Depending on the set of parameters these simulations can take a few hours or a few weeks to complete. This computational cost necessitates the use of scaling algorithms to interpolate between the data contained in the database. The tool-kit employs a discrete event method to simulate the movement and detector response of special nuclear material (SNM) through a GNDA node. Given the nature of a discrete event simulation, constant motion of SNM must be split up in to discrete spatial detection points. The fidelity required of the spatial splitting to achieve a properly converged answer is investigated here for a neutron detection system. The detector used was a SNAP-3 neutron detector in front of a sphere of SNM in the presence of background radiation. A parameter study has been performed to determine the spatial fidelity required for ROC curve convergence for moving objects in a discrete event simulator. It appears that 5 points is the minimum number of detection points with 7 points needed for one of the parameter sets. The convergence worsens with increases to detection length but appears to improve with increasing detector distance. These results will help future work involving quantifying the accuracy based on given tolerances and parameters. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high spatial resolution Stokes polarimeter for motional Stark effect imaging

We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A mesh partitioning algorithm for preserving spatial locality in arbitrary geometries

Highlights: •An algorithm for partitioning computational meshes is proposed. •The Morton order space-filling curve is modified to achieve improved locality. •A spatial locality metric is defined to compare results with existing approaches. •Results indicate improved performance of the algorithm in complex geometries. -- Abstract: A space-filling curve (SFC) is a proximity preserving linear mapping of any multi-dimensional space and is widely used as a clustering tool. Equi-sized partitioning of an SFC ignores the loss in clustering quality that occurs due to inaccuracies in the mapping. Often, this results in poor locality within partitions, especially for the conceptually simple, Morton order curves. We present a heuristic that improves partition locality in arbitrary geometries by slicing a Morton order curve at points where spatial locality is sacrificed. In addition, we develop algorithms that evenly distribute points to the extent possible while maintaining spatial locality. A metric is defined to estimate relative inter-partition contact as an indicator of communication in parallel computing architectures. Domain partitioning tests have been conducted on geometries relevant to turbulent reactive flow simulations. The results obtained highlight the performance of our method as an unsupervised and computationally inexpensive domain partitioning tool.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron characterization of UN/U-Si accident tolerant fuel prior to irradiation

Neutron imaging and tomographic reconstructions provide non-destructive three-dimensional characterization of nuclear fuel pellets that are typically about a cubic centimeter in volume with energy-resolved neutron imaging at a pulsed neutron source offering unique characterization not possible at a reactor source. Recent measurements at the Los Alamos Neutrons Science Center (LANSCE) studied a series of uranium nitride / uranium silicide ceramic composite pellets. This paper provides examples of spatially resolved measurements of cracks, isotopic enrichment and density with a (current) spatial resolution of approximately 75 microns. Phase and texture measurements were also performed but are not discussed in this paper. The UN/U-Si systems are under consideration as candidate systems for accident tolerant fuel. The examples are taken from measurements on a total of 9 pellets of differing UN/U-Si formulations (2 enrichment levels), U{sub 3}Si{sub 5} reference formulations (two enrichment levels) and pellets with known flaws. The {sup 235}U enrichments ranged from 0.2 to 8.8 wt.%. Pellets of the same composition are scheduled for irradiation in the Advanced Test Reactor this year. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗