Search NASA⌕ Search

SEARCH · Search NASA

Results for “study design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Development of Pneumatic Channel Wing Powered-Lift Advanced Super-STOL Aircraft

The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. A preliminary design study of this pneumatic vehicle based on previous wind-tunnel and flight-test data for the two technologies integrated into a simple Pneumatic Channel Wing (PCW) configuration showed very strong Super-STOL potential. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (C(sub L) values of 8.5 to 9.0). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg-45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. This paper presents these experimental results, discusses variations in the configuration geometry under development, and extends this integrated technology to advanced design studies of PCW-type vehicles.

Englar, Robert J.↗

A traits-based approach for prioritizing species for monitoring and surrogacy selection

The bar for justifying the use of vertebrate animals for study is being increasingly raised, thus requiring increased rigor for species selection and study design. Although we have power analyses to provide quantitative backing for the numbers of organisms used, quantitative backing for selection of study species is not frequently employed. This can be especially important when measuring the impacts of ecosystem alteration, when study species must be chosen that are both sensitive to the alteration and of sufficient abundance for study. Just as important is providing justification for designation of surrogate species for study, especially when the species of interest is rare or of conservation concern and selection of an appropriate surrogate can have legal implications. In this study, we use a combination of GIS, a fish traits database and multivariate statistical analyses to quantitatively prioritize species for study and to determine potential study surrogate species. We provide two case studies to illustrate our quantitative, traits-based approach for designating study species and surrogate species. In the first case study, we select broadly representative fish species to understand the effects of turbine passage on adult fishes based on traits that suggest sensitivity to turbine passage. In our second case study, we present a framework for selecting a surrogate species for an endangered species. Lastly, we suggest that our traits-based framework can provide quantitative backing and added justification to selection of study species while expanding the inference space of study results.

54 ENVIRONMENTAL SCIENCES↗

Self Assembling Mars Transfer Vehicles: The Preferred Concept of the Space Transfer Concepts and Analysis for Explorations Missions Study

Recently, one of the most comprehensive design studies of conceptual manned Mars vehicles, conducted since the Apollo era Mars mission studies of the 1960's, was completed. One of the tasks of the study involved the analysis of nuclear thermal propulsion spacecraft for Manned Mars exploration missions. This paper describes the specific effort aimed at vehicle configuration design. Over the course of the four year study, three configuration baselines were developed, each reflecting trade study cycle results of sequential phases of the study. Favorable attributes incorporated into the final concept, including a capability for on-orbit self-assembly and ease of launch vehicle packability, represent design solutions to configuration deficiencies plaguing nuclear propulsion Mars spacecraft design since the vehicle archetype originated in the 1950's. This paper contains a narrative summary of significant milestones in the effort, describes the evolution to the preferred configuration, and set forth the benefits derived from its utilization.

Donahue, Benjamin↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II Ground Vibration Stability Studies and Design Implementation

We report that next-generation synchrotron accelerator facilities pushing the envelope of resolution to just a few nanometers and possibly atomic scale (~1 nm) require extreme stability of their experimental setting. Such stability is greatly influenced by the background micro-seismic activity and natural disturbance sources that are present throughout the globe and the cultural, man-made noise stemming from traffic on nearby highways and railways, operating machinery, and other activities. Defenses against such negatively impacting environment include smart conventional design of facilities, isolation of experiments, careful consideration of the selected site by providing ample distance from sources or protection by depth and, most importantly, qualification/quantification of the ground vibration environment both in terms of amplitude and spectral characteristics. Qualification and quantification of the site-specific noise environment may be utilized in the implementation of defense features in the design of the facility and high-sensitivity experiments. The performance is measured by the adherence to specific stability criteria that are ever-demanding, given the nature of the experiments that are sought where resolution down to a few nanometers is required. Furthermore, the selection of the optimal site and the quantification of the unavoidable background noise are important aspects to be considered in assessing the performance of such facilities.

36 MATERIALS SCIENCE↗

Enabling Smart Grid Cosimulation Studies: Rapid Design and Development of the Technologies and Controls

The 21st century electric power grid is transforming with an unprecedented increase in demand and increase in new technologies. In the United States Energy Independence and Security Act of 2007, Title XIII sets the tenets for modernizing the electricity grid through what is known as the 'Smart Grid Initiative.' This initiative calls for increased design, deployment, and integration of distributed energy resources, smart technologies and appliances, and advanced storage devices. The deployment of these new technologies requires rethinking and re-engineering the traditional boundaries between different electric power system domains.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

Predicting Postoperative Injury and Military Discharge Status After Knee Surgery in the US Army

Background: Researchers have assessed postoperative injury or disability predictors in the military setting but typically focused on 1 type of surgical procedure at a time, used relatively small sample sizes, or investigated mixed cohorts with civilian populations. Purpose: To identify the relationship between baseline variables and injury incidence or military discharge status in US Army soldiers after knee surgery. Study Design: Case-control study; Level of evidence, 3. Methods: Data were obtained from a repository containing personnel, performance, and medical records for all active-duty US Army soldiers. Multivariate logistic regressions were used to estimate the effects of numerous variables on postoperative injury or on medical discharge. Variable selection and model validation were conducted using the k-fold method. Results: A total of 7567 soldiers underwent knee surgery between 2017 and 2019. Meniscal procedures were the most common type of surgery (39%), and approximately 71% of the cohort had a postoperative injury. Significant predictors for sustaining a postoperative injury included having a previous nonknee injury (odds ratio [OR], 1.5), female sex (OR, 1.3), and Black race (OR, 1.2). Within 4 years after surgery, 17% of soldiers were discharged from the military because of knee-related disability. Significant predictors for discharge from duty included enlisted rank (OR, 2.3), recent fitness test failure (OR, 1.9), number of previous knee surgeries (OR, 1.7), and having a previous nonknee injury (OR, 1.6). Conclusion: After knee surgery, nearly three-fourths of the soldiers in this cohort sustained a postoperative injury and almost one-fifth of soldiers were medically discharged from the military within 4 years. This study identified variables that indicate statistically increased risk for these postoperative outcomes and highlighted potentially modifiable factors.

Orthopedics↗

Adjuvant Hepatic Arterial Infusion Pump Chemotherapy After Resection of Colorectal Liver Metastases: Results of a Safety and Feasibility Study in The Netherlands

Background: The 10-year overall survival with adjuvant hepatic arterial infusion pump (HAIP) chemotherapy after resection of colorectal liver metastases (CRLMs) was 61% in clinical trials from Memorial Sloan Kettering Cancer Center. A pilot study was performed to evaluate the safety and feasibility of adjuvant HAIP chemotherapy in patients with resectable CRLMs. Study Design: A phase II study was performed in two centers in The Netherlands. Patients with resectable CRLM without extrahepatic disease were eligible. All patients underwent complete resection and/or ablation of CRLMs and pump implantation. Safety was determined by the 90-day HAIP-related postoperative complications from the day of pump placement (Clavien–Dindo classification, grade III or higher) and feasibility by the successful administration of the first cycle of HAIP chemotherapy. Results: A total of 20 patients, with a median age of 57 years (interquartile range [IQR] 51–64) were included. Grade III or higher HAIP-related postoperative complications were found in two patients (10%), both of whom had a reoperation (without laparotomy) to replace a pump with a slow flow rate or to reposition a flipped pump. No arterial bleeding, arterial dissection, arterial thrombosis, extrahepatic perfusion, pump pocket hematoma, or pump pocket infections were found within 90 days after surgery. After a median of 43 days (IQR 29–52) following surgery, all patients received the first dose of HAIP chemotherapy, which was completed uneventfully in all patients. Conclusion: Pump implantation is safe, and administration of HAIP chemotherapy is feasible, in patients with resectable CRLMs, after training of a dedicated multidisciplinary team.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Pressure, High-Temperature Thermal Hydraulic Test Facility for Nuclear-Renewable Hybrid Energy System Studies; Facility Design Description and Status Report

A high-pressure, high-temperature water flow loop has been designed at Idaho National Laboratory (INL) for deployment in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL) within the Energy Systems Laboratory (ESL) D100 northwest high bay. This loop is the first of three thermally coupled flow loops that will comprise the Advanced Reactor Technology Integral System Test (ARTIST) facility. The ARTIST facility will ultimately include a high temperature helium loop and a liquid salt loop, in addition to the PWR loop. The high-pressure water loop will operate at Pressurized Water Reactor (PWR) conditions. It will support experimental research on nuclear-renewable hybrid energy systems as well as advanced reactor technology topics. Within DETAIL, the water flow loop will also serve as a thermal energy source, emulating a reactor system. The loop will be thermally integrated with co-located energy systems including a thermal energy transport loop, thermal energy storage system, and a 25 kW high-temperature electrolysis system for hydrogen production. DETAIL will include additional energy systems such as an integrated microgrid and renewable energy systems including solar photovoltaics. The electrically heated flow loop will be dynamically controlled to simulate nuclear fuel behavior under normal and off-normal operating conditions. DETAIL will be designed for characterization of complex system dynamics. The various components will be interfaced with Digital Real-Time Simulators for supervisory control and dynamic simulation of complete systems. The design and assembly of the high-pressure water flow loop and supporting systems has been subdivided into two Phases. Phase 1, which will be completed by the end of FY17, includes installation of cable trays and supports, electrical conduit, DI water system, drain lift station and the concrete pad for the chiller located outside of the laboratory. Phase 2 includes the detailed design and final assembly of the flow loop, supporting structures and personnel platforms, the chiller and associated piping. As of September, 2017, the final detailed design of the flow loop is complete. Funding for Phase 2 procurement, assembly, system operability checkout, shakedown testing and initial operation of the flow loop is requested for FY18.

42 ENGINEERING↗

Gamma mirrors Quarterly Progress Report Y1Q4 FY2019

During the fourth quarter of FY19, we completed task 1.2 of Phase 1, the data analysis of the experimental campaign conducted at the Irradiated Fuel Examination Laboratory (IFEL) at ORNL. The best part of the analysis was conducted during the third quarter and the relevant findings can be found in the FY19 Q3 report. Phase II of the project was started during the month of September, more specifically Task 2. All experiments so far were conducted with ultrasmooth flat optics with a periodic multilayer coating with reflectivity of >80% in the 100 keV range. We have been determining the best available simulation tools to model X-ray focusing optics, typically made of quadratic surfaces, in order to survey the relevant parameter space and conduct the design study. Candidate focusing optics designs are Wolter I optics, Kirkpatrick-Baez or KB optics and Schmidt optics. Informed by the IFEL results, we are also considering a single-reflection concentrator design to attempt to quantify possible trade-off between bandpass multilayers overall reflectivity, multiple reflections and energy selectivity.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Front-end engineering design (FEED) studies: a quantitative analysis

NETL has devised a methodology for normalizing FEED study metrics of interest and allowing cautious quantitative comparison across FEED studies. This presentation introduces the novel quantitative comparison methodology and presents results from utilizing this methodology to examine data presented in recent FEED study reports. The quantitative methodology developed for the examination of FEED study performance and cost also allows comparison of real-world performance and costs against NETL TEA model predicted performance and cost. Learnings from examining NETL model predicted performance and cost versus real world reported values are highlighted. These learnings provide insight into NETL TEA model uncertainty and highlight opportunities for further model development.

FEED Studies↗

EIC ESR beam position monitors thermal and thermomechanical study preliminary design

The Electron Ion Collider (EIC) Electron Storage Ring (ESR) Beam Position Monitors (BPM) are designed to monitor the electron beam orbit position on a turn-by-turn and bunch-by-bunch basis in the vacuum chamber. Large variations in ESR fill pattern and bunch intensity imposes a large dynamic range on the BPM system design. And given the large ESR beam current - up to 2.5 A with 1160 x 20 nC bunches – the heating by synchrotron radiation (SR) and beam impedance is a significant concern. The high energy of the electrons – up to 18 GeV – leads to scat tering of the SR that produces high radiation doses and as sociated heating of structures away from the SR impact area. Because of this intense heating, and stringent position stability requirements, an in-depth engineering analysis was carried out. This paper will review the analysis made of the preliminary design and its main outcomes.

43 PARTICLE ACCELERATORS↗