Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Effect of brachytherapy technique and patient characteristics on cervical cancer implant dosimetry

Our purpose was to evaluate the relationship between brachytherapy technique and patient characteristics on dose to organs-at-risk (OARs) in patients undergoing high dose rate (HDR) brachytherapy for cervical cancer. From 1998 to 2008, 31 patients with cervical cancer with full dosimetric data were identified who received definitive external-beam radiation and HDR brachytherapy with tandem and ovoid applicators. Doses were recorded at point A, the International Commission on Radiation Units and Measurements (ICRU)-38 rectal point, the ICRU-38 bladder point, the vaginal surface, and the pelvic sidewall. Generalized estimating equations were used to determine the significance of changes in OAR to point A dose ratios with differences in brachytherapy technique or patient characteristics. Patients underwent a median of 5 brachytherapy procedures (range, 3 to 5), with a total of 179 procedures for 31 patients. For all brachytherapy treatments, the average ratios between the doses for the rectal, bladder, vaginal surface, and pelvic sidewall reference points to those at point A were 0.49, 0.59, 1.15, and 0.17, respectively. In general, decreased OAR dose was associated with a lower stage, younger age, increased ovoid size, increased tandem length, and earlier implant number. Increased tandem curvature significantly increased bladder dose and decreased rectal dose. Intravenous anesthesia usage was not correlated with improved dosimetry. This study allowed identification of patient and procedure characteristics influencing OAR dosing. Although the advent of 3-dimensional (3D) image-guided brachytherapy will bring new advances in treatment optimization, the actual technique involved at the time of the brachytherapy implant procedure will remain important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low–dose rate delivery techniques

Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatment planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. The volume receiving an 18-Gy (V{sub 18}) dose for the left and right kidneys was reduced by 10.6% and 12.5%, respectively, for the pancreatic plans. The volume receiving a 45-Gy (V{sub 45}) dose for the small bowel decreased from 65.3% to 45.5%. For the cases with prostate cancer, the volume receiving a 40-Gy (V{sub 40}) dose for the bladder and the rectum was reduced significantly by 25.1% and 51.2%, respectively. When compared with the RapidArc technique, the volume receiving a 30-Gy (V{sub 30}) dose for the left and the right kidneys was lower in the IMRT plans. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. These results clearly demonstrated that the PLDR-IMRT plan was suitable for PLDR pancreatic and prostate cancer treatments in terms of the overall plan quality. A significant reduction in the OAR dose was achieved with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. When compared with the PLDR-3DCRT plan, the PLDR-IMRT plan could provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent pancreatic and prostate cancers. The PLDR-IMRT plan is an effective treatment choice for recurrent cancers in most cancer centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technique for comprehensive head and neck irradiation using 3-dimensional conformal proton therapy

Owing to the technical and logistical complexities of matching photon and proton treatment modalities, we developed and implemented a technique of comprehensive head and neck radiation using 3-dimensional (3D) conformal proton therapy. A monoisocentric technique was used with a 30-cm snout. Cervical lymphatics were treated with 3 fields: a posterior-anterior field with a midline block and a right and a left posterior oblique field. The matchline of the 3 cervical nodal fields with the primary tumor site fields was staggered by 0.5 cm. Comparative intensity-modulated photon plans were later developed for 12 previously treated patients to provide equivalent target coverage, while matching or improving on the proton plans' sparing of organs at risk (OARs). Dosimetry to OARs was evaluated and compared by treatment modality. Comprehensive head and neck irradiation using proton therapy yielded treatment plans with significant dose avoidance of the oral cavity and midline neck structures. When compared with the generated intensity-modulated radiation therapy (IMRT) plans, the proton treatment plans yielded statistically significant reductions in the mean and integral radiation dose to the oral cavity, larynx, esophagus, and the maximally spared parotid gland. There was no significant difference in mean dose to the lesser-spared parotid gland by treatment modality or in mean or integral dose to the spared submandibular glands. A technique for cervical nodal irradiation using 3D conformal proton therapy with uniform scanning was developed and clinically implemented. Use of proton therapy for cervical nodal irradiation resulted in large volume of dose avoidance to the oral cavity and low dose exposure to midline structures of the larynx and the esophagus, with lower mean and integral dose to assessed OARs when compared with competing IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT

There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle{sup 3} with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D{sub 2cc}, D{sub mean}, D{sub max}, and dose fall-off parameters. For the organs at risk (OARs), D{sub 2cc}, D{sub 15cc}, D{sub 0.01cc}, V{sub 20}, V{sub 40}, V{sub 50}, V{sub 60}, and V{sub 80} were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p 3-arc , as compared with IMRT. VMAT{sub 3-arc} improved the bladder V{sub 40}, V{sub 50}, and V{sub 60}, and the bowel V{sub 20} and V{sub 50}. All fitted regressions had an R{sup 2} ≥ 0.98. For cervical SBRT plans, a VMAT{sub 3-arc} approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These improvements are further pronounced with the use of 10-MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid macrovoid characterization in membranes prepared via nonsolvent-induced phase separation: A comparison between 2D and 3D techniques

Optimizing the performance of asymmetric membranes prepared via nonsolvent-induced phase separation (NIPS) requires a quantitative understanding of how processing variables influence membrane morphology. Presently, the most useful structural quantification techniques require 3D visualization of the membrane structure and are best suited for studies seeking detailed information on small datasets. This study proposes and validates a rapid and accurate technique for quantifying macroporosity (i.e., D m ), a simple descriptor of sublayer macrovoid content in asymmetric membranes D m . values measured from segmented cross-sectional imaging performed via X-ray computed tomography (XCT) and scanning electron microscopy (SEM) are presented and compared for three asymmetric membranes prepared from commercial polymers. Importantly, analyses of 3D XCT membrane reconstructions reveal that D m is described by a single, centralized mean, which demonstrates that macrovoid content is spatially homogenous. Thus, D m can be approximated from limited sampling of the 2D cross-sectional membrane structure via SEM. A proposed 2D SEM sampling method provides D m estimates within ±6% of corresponding 3D XCT values with 30 independent measurements for the three membranes. Further sensitivity is achieved using complementary descriptors such as macrovoid count density (i.e., C m ). This technique is thus a useful tool for characterizing macroporosity from a broad selection of membrane samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A consistent path for phase determination based on transmission electron microscopy techniques and supporting simulations

Here this work addresses aspects for the analysis of industrial relevant materials via transmission electron microscopy (TEM). The complex phase chemistry and structural diversity of these materials require several characterization techniques to be employed simultaneously; unfortunately, different characterization techniques often lack connection to yield a complete and consistent picture. This paper describes a continuous path, starting with the acquisition of 3D diffraction data – alongside classical high-resolution imaging techniques – and linking the structural characterization of hard metal industrial samples with energy-loss fine-structure simulations, quantitative electron energy-loss (EEL) and energy-dispersive X-ray (EDX) spectroscopy. Thereby, the compositional analysis of a MAX phase indicated an offset of the hydrogenic, theoretical sensitivity factors, originating from poorly-adjusted screening factors. In a next step, these results were matched against quantitative compositions and parameters obtained from X-ray spectroscopy data, carried out synchronously with EELS.

36 MATERIALS SCIENCE↗

A New Mass Reconstruction Technique for Resonances Decaying to di-tau

Accurate reconstruction of the mass of a resonance decaying to a pair of $\tau$ leptons is challenging because of the presence of multiple neutrinos from $\tau$ decays. The existing methods rely on either a partially reconstructed mass, which has a broad spectrum that reduces sensitivity, or the collinear approximation, which is applicable only to the relatively small fraction of events. We describe a new technique, which provides an accurate mass reconstruction of the original resonance and does not suffer from the limitations of the collinear approximation. The major improvement comes from replacing assumptions of the collinear approximation by a requirement that mutual orientations of the neutrinos and other decay products are consistent with the mass and decay kinematics of a $\tau$ lepton. This is achieved by minimizing a likelihood function defined in the kinematically allowed phase space region. In this paper we describe the technique and illustrate its performance using $Z/\gamma^{*}\to\tau\tau$ and $H\to\tau\tau$ events simulated with the realistic detector resolution. The method is also tested on a clean sample of data $Z/\gamma^{*}\to\tau\tau$ events collected by the CDF experiment at the Tevatron. We expect that this new technique will allow for a major improvement in searches for the Higgs boson at both the LHC and the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

A new double time-of- ight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency- corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. As a result, this method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a model based reconstruction technique for neutron tomography at the PULSTAR reactor

Herein, a model based neutron computed tomography (CT) reconstruction technique is developed and implemented to improve the spatial resolution of the reconstructed images. The spatial resolution of a scintillator and a charge-coupled device (CCD) based digital neutron imaging system is quantified and used as the system response function in the iterative reconstruction process. The response function is included in the forward projection model to provide better estimation of the actual projection, thus improving the spatial resolution of the reconstructed images. Experiments were performed at the neutron imaging facility of the PULSTAR research reactor to corroborate the performance of the developed algorithm with a 50 μm and 250 μa m 6 LiF:ZnS thick scintillator. The reconstruction results of the model based technique have shown an improvement of nearly 40% in achievable spatial resolution as compared to the standard filtered back projection (FBP) technique.

47 OTHER INSTRUMENTATION↗

The ORNL analysis technique for extracting β -delayed multi-neutron branching ratios with BRIKEN

Here, many choices are available in order to evaluate large radioactive decay networks. There are many parameters that influence the calculated -decay delayed single and multi-neutron emission branching fractions. We describe assumptions about the decay model, background, and other parameters and their influence on β-decay delayed multi-neutron emission analysis. An analysis technique, the ORNL BRIKEN analysis procedure, for determining -delayed multi-neutron branching ratios in β-neutron precursors produced by means of heavy-ion fragmentation is presented. The technique is based on estimating the initial activities of zero, one, and two neutrons occurring in coincidence with an ion-implant and β trigger. The technique allows one to extract β-delayed multi-neutron decay branching ratios measured with the 3 He BRIKEN neutron counter. As an example, two analyses of the -neutron emitter 77 Cu based on different a priori assumptions are presented along with comparisons to literature values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas stopping and reacceleration techniques at the Facility for Rare Isotope Beams (FRIB)

The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a wide range of beams and energies for science with fast, stopped and reaccelerated rare-isotope beams. FRIB was commissioned in 2022 with the science program beginning in May 2022. Here, the combination of fast beams followed by gas stopping of rare-isotope beams together with reacceleration is unique to FRIB. Stopping techniques and beam manipulation at very-low energies are important to slow down fast beams for use in either stopped-beam experimental devices, or subsequent injection in the reaccelerator for experiments at energies ranging from 0.3 MeV/u to 12 MeV/u, depending on the Q/A of the ion. Innovative stopped-beam techniques to optimize the stopping and extraction efficiencies across a wide range of atomic numbers, as well as to reduce contamination and increase extraction speed, were developed. Reacceleration of those beams involve cooling, bunching, charge breeding and acceleration by a state-of-the-art superconducting reaccelerator, ReA. In this contribution we present the latest results of various gas stoppers and techniques to eliminate contaminants after reacceleration by the ReA.

43 PARTICLE ACCELERATORS↗

An adaptive knowledge-based data-driven approach for turbulence modeling using ensemble learning technique under complex flow configuration: 3D PWR sub-channel with DNS data

This work describes a new approach to increase the accuracy of Reynolds-averaged Navier–Stokes (RANS) in modeling turbulence flow leveraging the machine learning technique. Traditionally, different turbulence models for Reynolds stress are developed for different flow patterns based on human knowledge. Each turbulence model has a certain application domain and prediction uncertainty. In recent years, with the rapid improvements of machine learning techniques, researchers start to develop an approach to compensate for the prediction discrepancy of traditional turbulence models with statistical models and data. However, the approach has deficiencies in several aspects. For example, the amount of human knowledge introduced to the statistical model couldn’t be controlled, which makes the statistical model learn from a very naïve stage and limits its application. In this work, a new approach is developed to address those deficiencies. Here, the new approach uses the “ensemble learning” technique to control the amount of human knowledge introduced into the statistical model. Therefore, the new approach could be adaptive to the multiple application domains. In conclusion, according to the results of case study, the new approach shows higher accuracy than both traditional turbulence models and the previous machine learning approach.

42 ENGINEERING↗

Modeling simultaneous particle shrinkage, dissolution and breakage using the modified moving grid technique

Simultaneous shrinkage, dissolution and breakage are important particle size reduction phenomena that characterize processes like the reactive degradation of solid chemicals. The dynamics of the particle size distribution (PSD) for such processes are non-trivial to model due to the number expending processes brought about by the eventual dissolution of particles. To this end, Population Balance Model (PBM) resolved through the sectional techniques is the natural approach. Here, we introduce a modified Moving Grid technique (m-MGT) to accurately resolve the particle size reduction phenomena. Our technique mimics the perpetual particle shrinkage through a continuously left-moving size grid and incorporates a strategic grid removal routine to capture the disappearance of particles. Coupled with the Fixed Pivot (FP) discretization for breakage, our m-MGT not only preserves the moment-related properties, but also benchmarked very well against the analytical number densities and exhibited a minimum of first-order convergence in all assessed case studies.

97 MATHEMATICS AND COMPUTING↗

Formation and degradation mechanism of methylammonium lead iodide perovskite thin film fabricated by electrospray technique

Electrospray deposition technique has been reported previously for fabricating effective and stable perovskite thin film, leading to efficient perovskite solar cells. Here, in this work, a comprehensive investigation of the formation mechanism of methylammonium lead iodide perovskite (CH 3 NH 3 PbI 3 ) film by electrospray technique is demonstrated and compared to the formation mechanism through the conventional spin coating technique. In the electrospray process, charged MAI nanoparticles are gradually introduced onto the PbI 2 film, intercalating within the PbI 2 structure to produce the perovskite film. In contrast, the spin-coating method involves supplying the MAI solution in bulk, leading to perovskite crystal formation through the dissolution of the PbI 2 layer by the MAI solution, followed by recrystallization into perovskite oriented in the [110] direction, 30° inclined to the substrate. The impact of charge and the electric field on the formation of perovskite film using the electrospray is explored. Furthermore, the intrinsic stability of perovskite films is monitored in real-time in a highly humid environment (≥80 % relative humidity (RH)) using in-situ Grazing Incidence Wide Angle X-ray Scattering (GIWAXS), and a degradation mechanism is proposed to enhance the durability of the perovskite-based devices. The study further delves into the comparison of the stability of electrosprayed and spin-coated perovskite film, and the impact of humidity level and the presence of a hole-transporting layer on the stability of the perovskite layer. Overall, this work provides a detailed understanding of the formation and humidity-induced degradation mechanism of electrosprayed perovskite films, offering insights that can extend to various applications of perovskite materials.

14 SOLAR ENERGY↗

A Deep Learning-Driven Sampling Technique to Explore the Phase Space of an RNA Stem-Loop

The folding and unfolding of RNA stem-loops are critical biological processes; however, their computational studies are often hampered by the ruggedness of their folding landscape, necessitating long simulation times at the atomistic scale. Here, we adapted DeepDriveMD (DDMD), an advanced deep learning-driven sampling technique originally developed for protein folding, to address the challenges of RNA stem-loop folding. Although tempering- and order parameter-based techniques are commonly used for similar rare-event problems, the computational costs or the need for a priori knowledge about the system often present a challenge in their effective use. DDMD overcomes these challenges by adaptively learning from an ensemble of running MD simulations using generic contact maps as the raw input. DeepDriveMD enables on-the-fly learning of a low-dimensional latent representation and guides the simulation toward the undersampled regions while optimizing the resources to explore the relevant parts of the phase space. We showed that DDMD estimates the free energy landscape of the RNA stem-loop reasonably well at room temperature. Our simulation framework runs at a constant temperature without external biasing potential, hence preserving the information on transition rates, with a computational cost much lower than that of the simulations performed with external biasing potentials. Here, we also introduced a reweighting strategy for obtaining unbiased free energy surfaces and presented a qualitative analysis of the latent space. This analysis showed that the latent space captures the relevant slow degrees of freedom for the RNA folding problem of interest. Finally, throughout the manuscript, we outlined how different parameters are selected and optimized to adapt DDMD for this system. We believe this compendium of decision-making processes will help new users adapt this technique for the rare-event sampling problems of their interest.

Gupta, Ayush↗