Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Wind Turbine/Radar Interference: Offshore Test Options

This paper attempts to describe the options to expand the scope of the current Interagency Field Test & Evaluation (IFT&E) objectives to include wind turbine encroachment on agency missions for offshore wind development in the United States. The options described here build on the recently completed IFT&E test campaigns that took place in 2012 and 2013. Those tests, which looked at the CARSR, ASR-11, ARSR-4, and eight proposed mitigation technologies, found that wind turbines can significantly impact the ability of radars to detect aircraft and meet mission requirements above and near wind farms. One of the more immediate successes of the IF&E Program is that today, several of the infill radar technologies which were tested, took the results of their IF&TE performance to move well beyond Technology Readiness Level 6/7 and some have been deployed and are operating at airports in the United Kingdom (UK). As well, the UK Ministry of Defense (MOD) has deployed the replacement radar which was tested to address specific concerns with especially concerning offshore wind farms. The UK MOD continues to test and hopes to refine these systems so that identified shortfalls in surveillance capability and operations which remain can be addressed. Wind energy has been steadily growing in the U.S. With a current capacity of over 60 GW today and the expectation that this capacity will need to grow to 300 GW to meet the U.S. Department of Energy's (DOE) goal of 20% wind energy in the future, offshore wind farms are gaining more attention. The specific impacts of wind turbine interference on maritime radars have not been determined at this time. However, the DOE did fund a study conducted by the University of Texas at Austin entitled, "Assessment of Offshore Wind Farm Effects on Sea Surface, Subsurface and Airborne Electronic Systems," that focused on identifying the broader Wind-Turbine/Radar Interference: Offshore Test Options SAND2014-17870 effects of electromagnetic interference expected to be caused by offshore wind farms.' A review of that study would be worth the reader's time. And while no comprehensive field studies have been accomplished, it is worth noting that many mitigation solutions that were tested I the IFT&E Program are derived from short-range maritime radar systems. The Wind and Water Power Technologies Office (WWPTO), within the DOE Office of Energy Efficiency and Renewable Energy, supports the development, deployment, and commercialization of wind and water power technologies. This report is funded by the WWPTO.

17 WIND ENERGY↗

Operational flow visualization techniques in the Langley Unitary Plan Wind Tunnel

The unitary plan wind tunnel (UPWT) uses in daily operation are shown. New ideas for improving the quality of established flow visualization methods are developed and programs on promising new flow visualization techniques are pursued. The unitary plan wind tunnel is a supersonic facility, referred to as a production facility, although the majority of tests are inhouse basic research investigations. The facility has two 4 ft. by 4 ft. test sections which span a Mach range from 1.5 to 4.6. The cost of operation is about $10 per minute. Problems are the time required for a flow visualization test setup and investigation costs and the ability to obtain consistently repeatable results. Examples of sublimation, vapor screen, oil flow, minitufts, schlieren, and shadowgraphs taken in UPWT are presented. All tests in UPWT employ one or more of the flow visualization techniques.

Corlett, W. A.↗

A Comparison of the Automated Meteorological Profiling System High Resolution Flight Element to the Kennedy Space Center 50 MHz Doppler Wind Profiler

Wind profile measurement and the simulation of aerodynamic loads on a launch vehicle play an important role in determining launch capability and post launch assessment of the vehicle's performance. To date, all United States range certified wind profile measurement systems have been based on balloon tracking. Since the 1960's, the standard used by the National Aeronautics and Space Administration and the Air Force at the Cape Canaveral Air Station (CCAS) for detailed wind profile measurements has been the radar tracked, aerodynamically stabilized Jimsphere balloon system. Currently, the Air Force is nearing certification and operational implementation of the Automated Meteorological Profiling System (AMPS) at CCAS and Vandenburg Air Force Base (VAFB). AMPS uses the Global Positioning System for tracking the Jimsphere balloon. It is anticipated that the AMPS/Jimsphere, named the High Resolution Flight Element (HRFE), will have equivalent, or better resolution than the radar tracked Jimsphere, especially when the balloon is far downrange, at a low elevation angle. By the 1980's, the development of Doppler Wind Profilers (DWP) had become sufficiently advanced to justify an experimental measurement program at Kennedy Space Center (KSC). In 1989 a 50 MHz DWP was installed at KSC. In principal, the 50 MHz DWP has the capability to track the evolution of wind profile dynamics within 5 minutes of a launch. Because of fundamental differences in the measurement technique, there is a significant time and space differential between 50 MHz DWP and HRFE wind profiles. This paper describes a study to quantify these differences from a sample of 50 MHz DWP/HRFE pairs obtained during the AMPS certification test program.

Roberts, Barry C.↗

Defining Wind Energy Experience

Since 2015, the U.S. wind installed capacity has grown from 73 to over 120 gigawatts, creating jobs across many sectors and educational levels. The growth of the wind workforce will need to continue to meet the goal of 20% wind by 2030, as well as the Biden administration's goals to reduce greenhouse gas pollution by 2030, reach 100% carbon-free electricity by 2035, and achieve net-zero greenhouse gas emissions no later than 2050. Despite the needed and anticipated growth, there are challenges to meeting this demand. Research has consistently shown that it has been a challenge finding qualified applicants for open wind industry jobs. Between 2012 and 2018, the difficulty of finding qualified applicants increased from 62% to 68% according to industry respondents. In 2017, educational institutions and training programs reported that 67% of their students did not enter the wind energy industry. Research conducted in 2020 showed that 83% of interested workers had some or great difficulty finding job opportunities. In exploring reasons for this gap, the researchers found that challenges were primarily influenced by education, experience, and geography. This difficulty for wind industry employers, educational institutions, and the potential workforce is known as the "wind energy workforce gap." This report further investigates the experience aspect of this gap.

17 WIND ENERGY↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Understanding the Global Structure and Evolution of Coronal Mass Ejections in the Solar Wind

This report summarizes the technical progress made during the first six months of the second year of the NASA Living with a Star program contract Understanding the global structure and evolution of coronal mass ejections in the solar wind, between NASA and Science Applications International Corporation, and covers the period November 18, 2003 - May 17,2004. Under this contract SAIC has conducted numerical and data analysis related to fundamental issues concerning the origin, intrinsic properties, global structure, and evolution of coronal mass ejections in the solar wind. During this working period we have focused on a quantitative assessment of 5 flux rope fitting techniques. In the following sections we summarize the main aspects of this work and our proposed investigation plan for the next reporting period. Thus far, our investigation has resulted in 6 refereed scientific publications and we have presented the results at a number of scientific meetings and workshops.

Riley, Pete↗

Comparison of nozzle and afterbody surface pressures from wind tunnel and flight test of the YF-17 aircraft

Results are reported from the initial phase of an effort to provide an adequate technical capability to accurately predict the full scale, flight vehicle, nozzle-afterbody performance of future aircraft based on partial scale, wind tunnel testing. The primary emphasis of this initial effort is to assess the current capability and identify the cause of limitations on this capability. A direct comparison of surface pressure data is made between the results from an 0.1-scale model wind tunnel investigation and a full-scale flight test program to evaluate the current subscale testing techniques. These data were acquired at Mach numbers 0.6, 0.8, 0.9, 1.2, and 1.5 on four nozzle configurations at various vehicle pitch attitudes. Support system interference increments were also documented during the wind tunnel investigation. In general, the results presented indicate a good agreement in trend and level of the surface pressures when corrective increments are applied for known effects and surface differences between the two articles under investigation.

Lucas, E. J.↗

Pressure-Sensitive Paint and Video Model Deformation Systems at the NASA Langley Unitary Plan Wind Tunnel

Pressure-sensitive paint (PSP) and video model deformation (VMD) systems have been installed in the Unitary Plan Wind Tunnel at the NASA Langley Research Center to support the supersonic wind tunnel testing requirements of the High Speed Research (HSR) program. The PSP and VMD systems have been operational since early 1996 and provide the capabilities of measuring global surface static pressures and wing local twist angles and deflections (bending). These techniques have been successfully applied to several HSR wind tunnel models for wide ranges of the Mach number, Reynolds number, and angle of attack. A review of the UPWT PSP and VMD systems is provided, and representative results obtained on selected HSR models are shown. A promising technique to streamline the wind tunnel testing process, Modern Experimental Design, is also discussed in conjunction with recently-completed wing deformation measurements at UPWT.

Erickson, G. E.↗

Pressure-Sensitive Paint and Video Model Deformation Systems at the NASA Langley Unitary Plan Wind Tunnel

Pressure-sensitive paint (PSP) and video model deformation (VMD) systems have been installed in the Unitary Plan Wind Tunnel at the NASA Langley Research Center to support the supersonic wind tunnel testing requirements of the High Speed Research (HSR) program. The PSP and VMD systems have been operational since early 1996 and provide the capabilities of measuring global surface static pressures and wing local twist angles and deflections (bending). These techniques have been successfully applied to several HSR wind tunnel models for wide ranges of the Mach number, Reynolds number, and angle of attack. A review of the UPWT PSP and VMD systems is provided, and representative results obtained on selected HSR models are shown. A promising technique to streamline the wind tunnel testing process, Modern Experimental Design, is also discussed in conjunction with recently-completed wing deformation measurements at UPWT.

Erickson, G. E.↗

Computational Math Problems for a Clean Energy Future

Cutting edge computational mathematics are ubiquitous in renewable energy research. Problems in resilient and reliable electric grid operations, infrastructure planning, wind farm yaw control, and more demand sophisticated and scalable computational tools that enable the transition of renewable energy technologies from proof of concept to deployment into our energy system. The mission of the Computational Science Center at NREL is to lead the lab's efforts to solve energy challenges using high-performance computing (HPC), computational science, applied mathematics, scientific data management, visualization, and informatics. In this poster, we provide a short overview of three areas of computational mathematics research at NREL: wind power scenario generation for stochastic grid operations and infrastructure planning, improved rational function approximations for electromagnetic transients codes, and wind farm yaw control using a combination of the Alternating Direction Method of Multipliers (ADMM) and reinforcement learning (RL). Increasing penetrations of renewable energy into power grids motivate the investigation of new approaches to characterizing uncertainty for five-minute economic dispatch problems. Similarly, as the penetration of distributed energy resources on power grids increases, it becomes important to revisit our methods of modelling transient phenomena, i.e. electromagnetic transients programs. Finally, the combination of ADMM and RL for wind farm yaw control presented here can potentially increase the efficiency of the deployed distributed controllers by orders of magnitude.

ADMM↗

The George C. Marshall Space Flight Center's 14 X 14-Inch Trisonic Wind Tunnel: A Historical Perspective

A history of the National Aeronautics and Space Administration (NASA) George C. Marshall Space Flight Center's (MSFC) 14 x 14-Inch Trisonic Wind Tunnel is presented. Its early and continuing role in the United States space program is shown through highlights of the tunnel's history and the major programs tested in the tunnel over the past 40 years. The 14-Inch Tunnel has its beginning with the Army in the late 1950's under the Army Ballistic Missile Agency (ABMA). Such programs as the Redstone, Jupiter, Pershing, and early Saturn were tested in the 14-Inch Tunnel in the late 1950's. America's first launch vehicle, the Jupiter C, was designed and developed using the 14-Inch Wind Tunnel. Under NASA, the 14-Inch Wind Tunnel has made large contributions to the Saturn, Space Transportation System, and future launch vehicle programs such as Shuttle-C and the National Launch System. A technical description of the tunnel is presented for background information on the type and capabilities of the 14-Inch Wind Tunnel. The report concludes in stating: the 14-Inch Wind Tunnel as in speed of sound; transonic, at or near the speed of sound the past, will continue to play a large but unseen role in he development of America's space program.

A. Springer↗

Enabling Marine Energy Integration for Ocean Observing: Functional Requirements

Marine renewable energy (i.e., wave, tidal or ocean current, thermal gradient, and salinity gradient) or MRE can revolutionize ocean observing capabilities. Five use cases representing a range of ocean observing platforms were developed based on end-user feedback. Drawing from these use cases, common needs or functional requirements were developed to help guide the integration of MRE power delivery for ocean observation structures and functions. The functional requirements were determined from descriptions of the use cases, specifications of hardware that are used or closely associated with existing ocean observation platforms, and direct feedback from ocean observation sensor/platform developers and users. Twenty types of functional requirements were identified, including those associated with power and energy use; physical system requirements; temperature and depth; electrical, acoustic, and motion interference; and reliability. Each set of functional requirements is illustrated as features of the use cases. By defining functional requirements for MRE technology integration in ocean observing platforms, and focusing on end-user requirements, barriers to developing MRE-driven ocean observation missions can be reduced.

50 EE - Wind and Water Power Program - Water (EE-4↗

Economic Comparison Between Battery and Supercapacitor for Hourly Dispatching Wave Energy Converter Power

This paper demonstrates a dispatching scheme of slider-crank wave energy converter (WEC) power generation using two different kinds of energy storage components, namely, Lithium-ion (Li-ion) battery and Supercapacitors (SC). The performance of the two energy storage components has been compared in order to develop the most economical energy storage system for WEC hourly dispatching scheme. The cost optimization of the energy storage system considering both cycling and calendar aging expenses is made based on its usage of depth of discharge. In this study, extensive simulation is conducted in MATLAB/Simulink platform, and it is found that SC is a better solution than Li-ion battery in terms of economic assessment for hourly dispatching WEC power.

50 EE - Wind and Water Power Program - Water (EE-4↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid

Legacy energy management systems for distribution system or microgrids are typically driven by economics. During extreme events, resiliency can be defined as ability of the system to keep supplying critical loads. Resilient operation during extreme events (e.g. avalanche in Alaska) may require decision variables to be different and conflicting with economic operation. Operational objectives are driven by a complex consideration of the economic, reliable and resilient operation of the system: economic and reliable in normal operating state and resilient during extreme events. Challenge is to move between economic and resilient operation in optimal manner and setting up problem formulation and constraints specially with Distributed Energy Resources (DERs). In this paper, we focus on striking a balance between optimal economic and resilient operation using novel formulation and developed tool called Resiliency Enabled Energy System Operation Toolbox (RE-ESOT). Simulation results are provided for a real islanded grid in Alaska with battery energy systems.

50 EE - Wind and Water Power Program - Water (EE-4↗

Revisiting Theoretical Limits for One-Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one-degree-of-freedom wave energy converters. This paper considers the floating sphere used in the Ocean Energy Systems Task 10 Wave Energy Converter modeling and verification effort for analysis. Analytical equations are derived to determine bounds on the motion amplitude, time-averaged power, and power-take-off (PTO) force. A unique result was found that shows the time-averaged power absorbed by a wave energy converter can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force amplitude was derived that has provided upper and lower bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression can only provide a lower bound, as there is theoretically no upper bound. These bounds are used to compare the performance of a floating sphere if it were to extract energy using surge or heave motion. The analysis shows that because of the differences in hydrodynamic coefficients of each oscillating mode, there will be different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on power absorption while also utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate the time-averaged power with a nonideal PTO is modified by the mechanical-to-electrical efficiency and the ratio of the PTO spring and damping coefficients. The PTO spring and damping coefficients were separated in the expression, which allows for limits to be set on the possible values of PTO coefficients to ensure a net flow of power to the grid.

50 EE - Wind and Water Power Program - Water (EE-4↗

Implementation and Verification of Cable Bending Stiffness in MoorDyn

The relatively large motions experienced by floating wind turbines and wave energy converters pose a challenge for power cables, whose internal components provide significant bending resistance and are sensitive to deformation. The behavior and associated design considerations of power cables in these highly dynamic applications make coupled analysis relevant for design. Bending stiffness capabilities have recently been added to the lumped-mass mooring dynamics model MoorDyn to enable simulation of dynamic power cables. MoorDyn is a common modeling choice for floating wind energy simulation (often coupled with OpenFAST) and floating wave energy converter simulation (often coupled with WEC-Sim) but the model’s previous line elasticity formulation only considered axial stiffness. To properly capture the dynamics of power cables, a bending stiffness model has been added that approximates cable curvature based on the difference in tangent vectors of adjacent elements. The resulting bending moment is realized by applying forces on adjacent nodes, enabling cable modeling while leaving the underlying lumped-mass formulation unchanged. In this paper, the new bending stiffness implementation is verified in static conditions against analytical solutions and then in a dynamic power cable scenario in comparison with the commercial simulator OrcaFlex. The dynamic scenario uses prescribed motions and includes wave loadings on the cable. Results indicate correct implementation of bending stiffness and show close agreement with OrcaFlex.

50 EE - Wind and Water Power Program - Water (EE-4↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗