Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Status of the Design of 650 MHz Elliptical Cavities for Project X

Project X is a proposed high-intensity proton accelerator complex that could provide beam to create a high-intensity neutrino beam, feed protons to kaon- and muon-based precision experiments, and for other applications still under investigation. The present configuration of the proton accelerator foresees a section with 650 MHz β = 0.6 and β = 0.9 elliptical cavities. Prototypes of single-cell 650 MHz cavities and five-cell β = 0.9 650 MHz cavities are being designed and fabricated at Fermilab in the R&D process for Project X. This paper summarizes the design status of the β = 0.6 and β = 0.9 single-cell prototype cavities, and also addresses the design effort focused on the five-cell β = 0.9 cavities.

43 PARTICLE ACCELERATORS↗

R & D on Very-High-Current Superconducting Proton Linac, Final Report

The aim of this R&D project was to develop a superconducting cavity for a very-­ high-current proton accelerator. The particular application motivating the proposal was a LHC upgrade called the Superconducting Proton Linac, or SPL. Under the grant awarded to Stony Brook University the cavity was designed, a prototype copper cavity, followed by the niobium cavity, were built. A new set of HOM dampers was developed. The cavity has outstanding RF performance parameters – low surface fields, low power loss and all HOMs are fully damped. In fact, it is a “universal cavity” in the sense that it is suited for the acceleration of high-­current protons and well as high current electrons. Its damping of HOM modes is so good that it can see service in a multi-pass linac or an Energy Recovery Linac in addition to the easier service in a single-pass linac. Extensive measurements were made on the cavities and couplers, with the exception of the cold test of the niobium cavity. At the time of this report the cavity has been chemically processed and is ready for vertical testing which will be carried out shortly.

43 PARTICLE ACCELERATORS↗

SIMULATIONS OF A MUON LINAC FOR A NEUTRINO FACTORY

The Neutrino Factory baseline design involves a complex chain of accelerators including a single-pass linac, two recirculating linacs and an FFAG. The first linac follows the capture and bunching section and accelerates the muons from about 244 to 900 MeV. It must accept a high emittance beam about 30 cm wide with a 10% energy spread. This linac uses counterwound, shielded superconducting solenoids and 201 MHz superconducting cavities. Simulations have been carried out using several codes including Zgoubi, OptiM, GPT, Elegant and G4beamline, both to determine the optics and to estimate the radiation loads on the elements due to beam loss and muon decay.

43 PARTICLE ACCELERATORS↗

Cosmic ray acceleration by stellar wind. Simulation for heliosphere

The solar wind deceleration by the interstellar medium may result in the existence of the solar wind terminal shock. In this case a certain fraction of thermal particles after being heated at the shock would obtain enough energy to be injected to the regular acceleration process. An analytical solution for the spectrum in the frame of a simplified model that includes particle acceleration at the shock front and adiabatic cooling inside the stellar wind cavity has been derived. It is shown that the acceleration of the solar wind particles at the solar wind terminal shock is capable of providing the total flux, spectrum and radial gradients of the low-energy protons close to one observed in the interplanetary space.

Petukhov, S. I.↗

STATUS AND TEST RESULTS OF HIGH CURRENT 5-CELL SRF CAVITIES DEVELOPED AT JLAB

The development of a new compact CW cryomodule for use in future Energy Recovery Linacs (ERLs) and Free Electron Lasers (FELs) is underway at JLab with the objective of transporting beam current up to Ampere-levels. Design goals include broadband cavity Higher Order Mode (HOM) damping, HOMs tuned to safe frequencies to minimize the power extracted from the beam, good real-estate gradient and cryogenic efficiency and consideration of cost and maintainability. Two 1497 MHz high current niobium five-cell cavities with waveguide end groups have been manufactured recently. We report on the latest results including high field tests in a vertical Dewar at 2K and a detailed assessment of the impedance budget for beam breakup (BBU) instability. The general cryomodule and cavity concept is described as well.

43 PARTICLE ACCELERATORS↗

SURFACE ROUGHNESS REDUCTION AND PERFORMANCE OF Nb3Sn FILM FOR SRF APPLICATIONS

Nb3Sn offers better RF performance (Q and Eacc) than Nb at any given temperature because of its superior superconducting properties. The potential deployment of Nb3Sn-coated SRF cavities at 4 K, delivering similar performance to that of Nb cavities at 2 K, will be a transformational technology to enable new classes of SRF accelerator applications. A clean and smooth surface can enhance the performance of the Nb3Sn-coated cavity, typically, the attainable acceleration gradient. The reduction of surface roughness is often linked with a correlative reduction in average coating thickness and grain size. A new approach to enhance the nucleation centers using the pre-deposition of Sn on Nb is introduced for surface roughness reduction. Besides Sn supply's careful tuning, the temperature profiles were varied to engineer the coating surface with reduced roughness as low as ~40 nm in 20 µm × 20 µm AFM scans, one-third that of the typical coating. Electropolishing of coated sample shows surface a clear surface smoothening. A few sets of coating parameters were used to coat 1.3 GHz sin-gle-cell cavities to understand the effects of roughness variation on the RF performance. This presentation discusses ways to reduce surface roughness with results from a systematic analysis of the samples and Nb3Sn-coated single-cell cavities.

Pudasaini, Uttar↗

SURFACE ROUGHNESS REDUCTION AND PERFORMANCE OF Nb3Sn FILM FOR SRF APPLICATIONS

Nb3Sn offers better RF performance (Q and Eacc) than Nb at any given temperature because of its superior superconducting properties. The potential deployment of Nb3Sn-coated SRF cavities at 4 K, delivering similar performance to that of Nb cavities at 2 K, will be a transformational technology to enable new classes of SRF accelerator applications. A clean and smooth surface can enhance the performance of the Nb3Sn-coated cavity, typically, the attainable acceleration gradient. The reduction of surface roughness is often linked with a correlative reduction in average coating thickness and grain size. A new approach to enhance the nucleation centers using the pre-deposition of Sn on Nb is introduced for surface roughness reduction. Besides Sn supply's careful tuning, the temperature profiles were varied to engineer the coating surface with reduced roughness as low as ~40 nm in 20 µm × 20 µm AFM scans, one-third that of the typical coating. Electropolishing of coated sample shows surface a clear surface smoothening. A few sets of coating parameters were used to coat 1.3 GHz sin-gle-cell cavities to understand the effects of roughness variation on the RF performance. This presentation discusses ways to reduce surface roughness with results from a systematic analysis of the samples and Nb3Sn-coated single-cell cavities.

Pudasaini, Uttar↗

Visual, Optical and Replica Inspections: Surface Preparation of 650 MHz NB Cavity for PIP-II Linac

Surface preparation of niobium superconducting RF cavities is a critical step for achieving good RF performance under the superconducting state. Surface defect, roughness, and contamination affect the accelerating gradient and quality factor of the cavities. We report surface inspection methods used to control the surface processing of 650 MHz cavities designated for the pre-production and prototype cryomodules for PIP-II linac. The cavity surface was routinely inspected visually, with an optical camera, and by microscopic scanning of surface replicas. This article covers details on the surface inspection methods and surface polishing process used to repair the surface.

43 PARTICLE ACCELERATORS↗

Introduction to Superconducting RF Structures and the Effect of High Pressure Rinsing

This presentation begins by describing RF superconductivity and SRF accelerating structures. Then the use of superconducting RF structures in a number of accelerators around the world is reviewed; for example, the International Linear Collider (ILC) will use ~16,000 SRF cavities with ~2,000 cryomodules to get 500 GeV e⁺/e⁻ colliding energy. Field emission control was (and still is) a very important practical issue for SRF cavity development. It has been found that high-pressure ultrapure water rinsing as a final cleaning step after chemical surface treatment resulted in consistent performance of single- and multicell superconducting cavities.

43 PARTICLE ACCELERATORS↗

Large-acceptance linac for accelerating l9w-energy muons

We propose a high-gradient linear accelerator for accelerating low-energy muons and pions in a strong solenoidal magnetic field. The acceleration starts immediately after collection of pions from a target by solenoidal magnets and brings muons to a kinetic energy of about 200 MeV over a distance of the order of 10 m. At this energy, both an ionization cooling of the muon beam and its further acceleration in a superconducting linac become feasible. The project presents unique challenges - a very large energy spread in a highly divergent beam, as well as pion and muon decays - requiring large longitudinal and transverse acceptances. One potential solution incorporates a normal-conducting linac consisting of independently fed O-mode RF cavities with wide apertures closed by thin metal windows or grids. The guiding magnetic field is provided by external superconducting solenoids. The cavity choice, overall linac design considerations, and simulation results of muon acceleration are presented. While the primary applications of such a linac are for homeland defense and industry, it can provide muon fluxes high enough to be of interest for physics experiments.

43 PARTICLE ACCELERATORS↗

A Linac Simulation Code for Macro-particles Tracking and Steering Algorithm Implementation

n this paper, a linac simulation code written in Fortran90 is presented and several simu lation examples are given. This code is optimized to implement linac alignment and steering algorithms, and evaluate the accelerator errors such as RF phase and acceleration gradient, quadrupole and BPM misalignment. It can track a single particle or a bunch of particles through normal linear accelerator elements such as quadrupole, RF cavity, dipole corrector and drift space. One-to-one steering algorithm and a global alignment (steering) algorithm are implemented in this code.

Accelerators↗

Effects of Crab Cavities' Multipole Content in an Electron-Ion Collider

The impact on the beam dynamics of the Medium Energy Electron-Ion Colider (MEIC) due to the multipole content of the 750 MHz crab cavity was studied using thin multipole elements for 6D phase space particle tracking in ELEGANT. Target values of the sextupole component for the cavity’s field expansion were used to perform preliminary studies on the proton beam stability when compared to the case of pure dipole content of the rf kicks. Finally, important effects on the beam sizes due to non-linear components of the crab cavities’ fields were identified, and some criteria for their future study were proposed.

43 PARTICLE ACCELERATORS↗

RECENT RESULTS FROM Nb3Sn COATED SINGLE-CELL CAVITIES COMBINED WITH SAMPLE STUDIES AT JEFFERSON LAB

The critical temperature (~ 18 K) and superheating field (~ 425 mT) of Nb3Sn are almost twice that of niobium, thereby promising the higher quality factor and accelerating gradient at any given temperature compared to traditional SRF cavities made of niobium. It can enable higher temperature for cavity operation (4 K Vs. 2 K), resulting in significant reduction in both capital and operating cost for the cryoplant. Several single-cell cavities along with witness samples were coated with Nb3Sn to explore, understand and improve the coating process for betterment of cavity performance. RF measurements of coated cavities combined with material characterization of witness samples were employed to update the coating process. Following some modifications to the existing coating process, we were able to produce Nb3Sn cavity with quality factor ? 2.1010 for accelerating gradient up to 15 MV/m at 4 K, without any significant Q-slope. In this article, we will discuss recent results from several Nb3Sn coated single-cell cavities combined with material studies of witness samples.

Eremeev, G. V.↗

Multidose Stereotactic Radiosurgery (9 Gy × 3) of the Postoperative Resection Cavity for Treatment of Large Brain Metastases

Purpose: To evaluate the clinical outcomes with linear accelerator-based multidose stereotactic radiosurgery (SRS) to large postoperative resection cavities in patients with large brain metastases. Methods and Materials: Between March 2005 to May 2012, 101 patients with a single brain metastasis were treated with surgery and multidose SRS (9 Gy × 3) for large resection cavities (>3 cm). The target volume was the resection cavity with the inclusion of a 2-mm margin. The median cavity volume was 17.5 cm{sup 3} (range, 12.6-35.7 cm{sup 3}). The primary endpoint was local control. Secondary endpoints were survival and distant failure rates, cause of death, performance measurements, and toxicity of treatment. Results: With a median follow-up of 16 months (range, 6-44 months), the 1-year and 2-year actuarial survival rates were 69% and 34%, respectively. The 1-year and 2-year local control rates were 93% and 84%, with respective incidences of new distant brain metastases of 50% and 66%. Local control was similar for radiosensitive (non-small cell lung cancer and breast cancer) and radioresistant (melanoma and renal cell cancer) brain metastases. On multivariate Cox analysis stable extracranial disease, breast cancer histology, and Karnofsky performance status >70 were associated with significant survival benefit. Brain radionecrosis occurred in 9 patients (9%), being symptomatic in 5 patients (5%). Conclusions: Adjuvant multidose SRS to resection cavity represents an effective treatment option that achieves excellent local control and defers the use of whole-brain radiation therapy in selected patients with large brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of Single Crystal Niobium Cavities

We have fabricated and tested a total of six single cell niobium cavities, made from single crystal, high purity niobium. Two of the three cavities of the TESLA shape (1300 MHz) were made from Heraeus niobium by extending a smaller single crystal by rolling and annealing steps; the third cavity was made by spinning from CBMM material. The three other cavities of the scaled "Low Loss" (LL) shape (two) and "High Gradient" (HG) shape (one) resonated at 2.3 GHz and were fabricated from "as received" single crystals, both from Heraeus and CBMM niobium. After appropriate surface treatments by buffered chemical polishing and electropolishing most cavities performed quite nicely and peak surface magnetic fields of ~ 160 mT or above corresponding to accelerating gradients between 38 MV/m and 45 MV/m were reached. This paper reports about the performance of these cavities.

43 PARTICLE ACCELERATORS↗