Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Stark spectroscopy of a probe lithium beam excited with two dye lasers as a technique to study a high-power ion-beam diode

A non-disturbing measurement of electric field distributions is a subject of special interest in plasma physics and high-voltage devices. In this paper we describe a diagnostic technique for remote sensing of electric fields via injection of a probe beam of lithium atoms and cascade excitation of resonance fluorescence with two broadband dye lasers. The fluorescence spectrum was recorded using a monochromator equipped with an optical multi-channel analyser. The magnitude of the local electric field was retrieved from the Stark-shifted components of the 3d-2plithium spectral line. The technique was applied to measurements of the electric field in the applied-B-field high-voltage diode of the 1 TW KALIF ion-beam accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid-phase mega-electron-volt ultrafast electron diffraction

The conversion of light into usable chemical and mechanical energy is pivotal to several biological and chemical processes, many of which occur in solution. To understand the structure–function relationships mediating these processes, a technique with high spatial and temporal resolutions is required. Here, we report on the design and commissioning of a liquid-phase mega-electron-volt (MeV) ultrafast electron diffraction instrument for the study of structural dynamics in solution. Limitations posed by the shallow penetration depth of electrons and the resulting information loss due to multiple scattering and the technical challenge of delivering liquids to vacuum were overcome through the use of MeV electrons and a gas-accelerated thin liquid sheet jet. To demonstrate the capabilities of this instrument, the structure of water and its network were resolved up to the 3rd hydration shell with a spatial resolution of 0.6 Å; preliminary time-resolved experiments demonstrated a temporal resolution of 200 fs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All the fun of the FAIR: fundamental physics at the facility for antiproton and ion research

The Facility for Antiproton and Ion Research (FAIR) will be the accelerator-based flagship research facility in many basic sciences and their applications in Europe for the coming decades. FAIR will open up unprecedented research opportunities in hadron and nuclear physics, in atomic physics and nuclear astrophysics as well as in applied sciences like materials research, plasma physics and radiation biophysics with applications towards novel medical treatments and space science. FAIR is currently under construction as an international facility at the campus of the GSI Helmholtzzentrum for Heavy-Ion Research in Darmstadt, Germany. While the full science potential of FAIR can only be harvested once the new suite of accelerators and storage rings is completed and operational, some of the experimental detectors and instrumentation are already available and will be used starting in summer 2018 in a dedicated research program at GSI, exploiting also the significantly upgraded GSI accelerator chain. In conclusion, the current manuscript summarizes how FAIR will advance our knowledge in various research fields ranging from a deeper understanding of the fundamental interactions and symmetries in nature to a better understanding of the evolution of the Universe and the objects within.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large Adaptive Optics Survey for Substellar Objects around Young, Nearby, Low-mass Stars with Robo-AO

We present results from the Large Adaptive optics Survey for Substellar Objects, where the goal is to directly image new substellar companions (<70 M {sub Jup}) at wide orbital separations (≳50 au) around young (≲300 Myr), nearby (<100 pc), low-mass (≈0.1–0.8 M{sub ⊙}) stars. We report on 427 young stars imaged in the visible (i') and near-infrared (J or H ) simultaneously with Robo-AO on the Kitt Peak 2.1 m telescope and later the Maunakea University of Hawaii 2.2 m telescope. To undertake the observations, we commissioned a new infrared camera for Robo-AO that uses a low-noise high-speed SAPHIRA avalanche photodiode detector. We detected 121 companion candidates around 111 stars, of which 62 companions are physically associated based on Gaia DR2 parallaxes and proper motions, another 45 require follow-up observations to confirm physical association, and 14 are background objects. The companion separations range from 2 to 1101 au and reach contrast ratios of 7.7 mag in the near-infrared compared to the primary. The majority of confirmed and pending candidates are stellar companions, with ~5 being potentially substellar and requiring follow-up observations for confirmation. We also detected a 43 ± 9 M {sub Jup} and an 81 ± 5 M {sub Jup} companion that were previously reported. We found 34 of our targets have acceleration measurements detected using Hipparcos–Gaia proper motions. Of those, 58{sub -14}{sup +12}% of the 12 stars with imaged companion candidates have significant accelerations (χ{sup 2}>11.8), while only 23{sub -6}{sup +11}% of the remaining 22 stars with no detected companion have significant accelerations. The significance of the acceleration decreases with increasing companion separation. These young accelerating low-mass stars with companions will eventually yield dynamical masses with future orbit monitoring.

47 OTHER INSTRUMENTATION↗

Advances in in situ/operando techniques for catalysis research: enhancing insights and discoveries

Abstract Catalysis research has witnessed remarkable progress with the advent of in situ and operando techniques. These methods enable the study of catalysts under actual operating conditions, providing unprecedented insights into catalytic mechanisms and dynamic catalyst behavior. This review discusses key in situ techniques and their applications in catalysis research. Advances in in situ electron microscopy allow direct visualization of catalysts at the atomic scale under reaction conditions. In situ spectroscopy techniques like X-ray absorption spectroscopy and nuclear magnetic resonance spectroscopy can track chemical states and reveal transient intermediates. Synchrotron-based techniques offer enhanced capabilities for in situ studies. The integration of in situ methods with machine learning and computational modeling provides a powerful approach to accelerate catalyst optimization. However, challenges remain regarding radiation damage, instrumentation limitations, and data interpretation. Overall, continued development of multi-modal in situ techniques is pivotal for addressing emerging challenges and opportunities in catalysis research and technology.

Chen, Linfeng↗

SPIRAL2 at GANIL: Status and Perspectives

To pursue the investigation of a new territory of nuclei with extreme N/Z called 'terra incognita' several projects, all aiming at the increase by several orders of magnitude of the RIB intensities are now under discussions worldwide. In Europe, two major new projects have been approved recently FAIR-GSI using the so-called 'in-flight' method and SPIRAL2-GANIL, based on the ISOL method. Both projects were selected in the European Strategic Roadmap For research Infrastructures (ESFRI). The main goal of SPIRAL2 is clearly to extend our knowledge of the limit of existence and the structure of nuclei deeply in the medium and heavy mass region (A = 60 to 140) which is to day an almost unexplored continent. SPIRAL 2 is based on a high power, CW, superconducting driver LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 10{sup 13} fissions/s. The expected radioactive beams intensities for exotic species in the mass range from A = 60 to A = 140, of the order of 10{sup 6} to 10{sup 10} pps will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100 {mu}A to 1 mA), heavier ions up to Ar at 14 MeV/n producing also proton rich exotic nuclei. In applied areas SPIRAL2 is considered as a powerful variable energy neutron source, a must to study the impact of nuclear fission and fusion on materials. The intensities of these unstable species are excellent opportunities for new tracers and diagnostics either for solid state, material or for radiobiological science and medicine. The 'Go' decision has been taken in May 2005. The investments and personnel costs amount to 190 Meuro, for the construction period 2006-2012. Construction of the SPIRAL2 facility is shared by ten French laboratories and a network of international partners. Under the 7FP program of European Union called 'Preparatory phase for the construction of new facilities', the SPIRAL2 project has been granted a budget of about 4Meuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and technical R and D programs for physics instrumentation (detectors, spectrometers) in collaboration with EU and International partners will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

World lays groundwork for future linear collider

With the Large Hadron Collider at CERN finally working, the particle-physics community can now afford to divide its attention between achieving LHC results and preparing for the next machine on its wish list, an electron-positron linear collider. The preparations involve developing and deciding on the technology for such a machine, the mode of its governance, and how to balance regional and global particle- and accelerator-physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Experimental analysis of general ion recombination in a liquid-filled ionization chamber in high-energy photon beams

Purpose: To study experimentally the general ion recombination effect in a liquid-filled ionization chamber (LIC) in high-energy photon beams. Methods: The general ion recombination effect on the response of a micro liquid ion chamber (microLion) was investigated with a 6 MV photon beam in normal and SRS modes produced from a Varian{sup Registered-Sign} Novalis Tx{sup TM} linear accelerator. Dose rates of the linear accelerator were set to 100, 400, and 1000 MU/min, which correspond to pulse repetition frequencies of 60, 240, and 600 Hz, respectively. Polarization voltages applied to the microLion were +800 and +400 V. The relative collection efficiency of the microLion response as a function of dose per pulse was experimentally measured with changing polarization voltage and pulse repetition frequencies and was compared with the theoretically calculated value. Results: For the 60 Hz pulse repetition frequency, the experimental relative collection efficiency was not different from the theoretical one for a pulsed beam more than 0.3% for both polarization voltages. For a pulsed radiation beam with a higher pulse repetition frequency, the experimental relative collection efficiency converged to the theoretically calculated efficiency for continuous beams. This result indicates that the response of the microLion tends toward the response to a continuous beam with increasing pulse repetition frequency of a pulsed beam because of low ion mobility in the liquid. Conclusions: This work suggests an empirical method to correct for differences in general ion recombination of a LIC between different radiation fields. More work is needed to quantitatively explain the LIC general ion recombination behavior in pulsed beams generated from linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Radiation Testing for Nuclear Inspection Systems (Final CRADA Report)

Higher-radiation hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems has developed a radiation-hardened vision system for Nuclear Energy applications. The high-radiation hardness testing of this vision system was conducted using the Argonne Low-Energy Accelerator Facility (LEAF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concepts Rookie Book

This book begins with the basic accelerator knowledge required to understand the latter chapters. This is followed by topics from Fermilab accelerator specifics to general accelerator physics concepts. These chapters are accompanied by descriptions of the instrumentation and utilities required to operate a high-energy physics laboratory. Last, we discuss the role of operators in safety at the lab.

43 PARTICLE ACCELERATORS↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

Systems and methods of varying charged particle beam spot size

Methods and devices enable shaping of a charged particle beam. A modified dielectric wall accelerator includes a high gradient lens section and a main section. The high gradient lens section can be dynamically adjusted to establish the desired electric fields to minimize undesirable transverse defocusing fields at the entrance to the dielectric wall accelerator. Once a baseline setting with desirable output beam characteristic is established, the output beam can be dynamically modified to vary the output beam characteristics. The output beam can be modified by slightly adjusting the electric fields established across different sections of the modified dielectric wall accelerator. Additional control over the shape of the output beam can be excreted by introducing intentional timing de-synchronization offsets and producing an injected beam that is not fully matched to the entrance of the modified dielectric accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗