Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adding Nuclear”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Deformation of Prostate and Seminal Vesicles Relative to Intraprostatic Fiducial Markers

Purpose: To quantify the residual geometric uncertainties after on-line corrections with intraprostatic fiducial markers, this study analyzed the deformation of the prostate and, in particular, the seminal vesicles relative to such markers. Patients and Methods: A planning computed tomography (CT) scan and three repeat CT scans were obtained for 21 prostate cancer patients who had had three to four cylindrical gold markers placed. The prostate and whole seminal vesicles (clinical target volume [CTV]) were delineated on each scan at a slice thickness of 1.5 mm. Rigid body transformations (translation and rotation) mapping the markers onto the planning scan positions were obtained. The translation only (T{sub only}) or both translation and rotation were applied to the delineated CTVs. Next, the residue CTV surface displacements were determined using nonrigid registration of the delineated contours. For translation and rotation of the CTV, the residues represented deformation; for T{sub only}, the residues stemmed from deformation and rotation. T{sub only} represented the residues for most currently applied on-line protocols. The patient and population statistics of the CTV surface displacements were calculated. The intraobserver delineation variation was similarly quantified using repeat delineations for all patients and corrected for. Results: The largest CTV deformations were observed at the anterior and posterior side of the seminal vesicles (population average standard deviation {<=}3 mm). Prostate deformation was small (standard deviation {<=}1 mm). The increase in these deviations when neglecting rotation (T{sub only}) was small. Conclusion: Although prostate deformation with respect to implanted fiducial markers was small, the corresponding deformation of the seminal vesicles was considerable. Adding marker-based rotational corrections to on-line translation corrections provided a limited reduction in the estimated planning margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Prospective, Phase II Study of Long-Term Androgen Ablation, Pelvic Radiotherapy, Brachytherapy Boost, and Adjuvant Docetaxel in Patients With High-Risk Prostate Cancer

Purpose: We report the long-term results of a prospective, Phase II study of long-term androgen deprivation (AD), pelvic radiotherapy (EBRT), permanent transperineal prostate brachytherapy boost (PB), and adjuvant docetaxel in patients with high-risk prostate cancer. Methods and Materials: Eligibility included biopsy-proven prostate adenocarcinoma with the following: prostate-specific antigen (PSA) > 20 ng/ml; or Gleason score of 7 and a PSA >10 ng/ml; or any Gleason score of 8 to 10; or stage T2b to T3 irrespective of Gleason score or PSA. Treatment consisted of 45 Gy of pelvic EBRT, followed 1 month later by PB with either iodine-125 or Pd-103. One month after PB, patients received three cycles of docetaxel chemotherapy (35 mg/m{sup 2} per week, Days 1, 8, and 15 every 28 days). All patients received 2 years of AD. Biochemical failure was defined as per the Phoenix definition (PSA nadir + 2). Results: From August 2000 to March 2004, 42 patients were enrolled. The median overall and active follow-ups were 5.6 years (range, 0.9-7.8 years) and 6.3 years (range, 4-7.8 years), respectively. Grade 2 and 3 acute genitourinary (GU) and gastrointestinal (GI) toxicities were 50.0% and 14.2%, respectively, with no Grade 4 toxicities noted. Grade 3 and 4 acute hematologic toxicities were 19% and 2.4%, respectively. Of the patients, 85.7% were able to complete the planned multimodality treatment. The 5- and 7-year actuarial freedom from biochemical failures rates were 89.6% and 86.5%, and corresponding rates for disease-free survival were 76.2% and 70.4%, respectively. The 5- and 7-year actuarial overall survival rates were 83.3% and 80.1%, respectively. The 5- and 7-year actuarial rates of late Grade 2 GI/GU toxicity (no Grade 3-5) was 7.7%. Conclusions: The trimodality approach of using 2 years of AD, external radiation, brachytherapy, and upfront docetaxel in high-risk prostate cancer is well tolerated, produces encouraging long-term results, and should be validated in a multi-institutional setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Jefferson Lab program: From 6 GeV operations to the 12 GeV upgrade

The Thomas Jefferson National Laboratory and the CEBAF accelerator operated for more than a decade, running a comprehensive scientific program that improved our understanding of the strong interaction. The facility is now moving toward an upgrade of the machine, from 6 to 12 GeV; a new experimental hall will be added and the equipment of the three existing halls will be enhanced. In this contribution some selected results from the rich physics program run at JLab, as well as the prospects for the near future, will be presented.

43 PARTICLE ACCELERATORS↗

The potential for aeration of MSW landfills to accelerate completion

Landfilling is a popular waste disposal method, but, as it is practised currently, it is fundamentally unsustainable. The low short-term financial costs belie the potential long-term environmental costs, and traditional landfill sites require long-term management in order to mitigate any possible environmental damage. Old landfill sites might require aftercare for decades or even centuries, and in some cases remediation may be necessary. Biological stabilisation of a landfill is the key issue; completion criteria provide a yardstick by which the success of any new technology may be measured. In order for a site to achieve completion it must pose no risk to human health or the environment, meaning that attenuation of any emissions from the site must occur within the local environment without causing harm. Remediation of old landfill sites by aerating the waste has been undertaken in Germany, the United States, Italy and The Netherlands, with considerable success. At a pilot scale, aeration has also been used in newly emplaced waste to accelerate stabilisation. This paper reviews the use of aerobic landfill worldwide, and assesses the ways in which the use of aerobic landfill techniques can decrease the risks associated with current landfill practices, making landfill a more sustainable waste disposal option. It focuses on assessing ways to utilise aeration to enhance stabilisation. The results demonstrated that aeration of old landfill sites may be an efficient and cost-effective method of remediation and allow the date of completion to be brought forward by decades. Similarly, aeration of newly emplaced waste can be effective in enhancing degradation, assisting with completion and reducing environmental risks. However, further research is required to establish what procedure for adding air to a landfill would be most suitable for the UK and to investigate new risks that may arise, such as the possible emission of non-methane organic compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MULTI-DIMENSIONAL MODELS FOR DOUBLE DETONATION IN SUB-CHANDRASEKHAR MASS WHITE DWARFS

Using two-dimensional and three-dimensional simulations, we study the ''robustness'' of the double detonation scenario for Type Ia supernovae, in which a detonation in the helium shell of a carbon-oxygen white dwarf induces a secondary detonation in the underlying core. We find that a helium detonation cannot easily descend into the core unless it commences (artificially) well above the hottest layer calculated for the helium shell in current presupernova models. Compressional waves induced by the sliding helium detonation, however, robustly generate hot spots which trigger a detonation in the core. Our simulations show that this is true even for non-axisymmetric initial conditions. If the helium is ignited at multiple points, then the internal waves can pass through one another or be reflected, but this added complexity does not defeat the generation of the hot spot. The ignition of very low-mass helium shells depends on whether a thermonuclear runaway can simultaneously commence in a sufficiently large region.

79 ASTRONOMY AND ASTROPHYSICS↗

Comment on 'Hadronic {sup 3}He{eta} production near threshold'

Measurements of the differential and total cross sections for the pd{yields}{sup 3}He{eta} reaction at five energies were recently reported [Phys. Rev. C 75, 014004 (2007)] and comparisons with theoretical models were made. We point out that these comparisons involved a model based on ad hoc assumptions and hence the conclusions regarding the reaction mechanism as well as the role of the higher partial waves drawn in the above work are misleading. Revised conclusions based on better model calculations are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancements to the MCNP6 background source

The particle transport code MCNP has been used to produce a background radiation data file on a worldwide grid that can easily be sampled as a source in the code. Location-dependent cosmic showers were modeled by Monte Carlo methods to produce the resulting neutron and photon background flux at 2054 locations around Earth. An improved galactic-cosmic-ray feature was used to model the source term as well as data from multiple sources to model the transport environment through atmosphere, soil, and seawater. A new elevation scaling feature was also added to the code to increase the accuracy of the cosmic neutron background for user locations with off-grid elevations. Furthermore, benchmarking has shown the neutron integral flux values to be within experimental error.

61 RADIATION PROTECTION AND DOSIMETRY↗

SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 4 TANK 21H QUALIFICATION SAMPLES

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H to qualify them for use in the Integrated Salt Disposition Program (ISDP) Batch 4 processing. All sample results agree with expectations based on prior analyses where available. No issues with the projected Salt Batch 4 strategy are identified. This revision includes additional data points that were not available in the original issue of the document, such as additional plutonium results, the results of the monosodium titanate (MST) sorption test and the extraction, scrub strip (ESS) test. This report covers the revision to the Tank 21H qualification sample results for Macrobatch (Salt Batch) 4 of the Integrated Salt Disposition Program (ISDP). A previous document covers initial characterization which includes results for a number of non-radiological analytes. These results were used to perform aluminum solubility modeling to determine the hydroxide needs for Salt Batch 4 to prevent the precipitation of solids. Sodium hydroxide was then added to Tank 21 and additional samples were pulled for the analyses discussed in this report. This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-14-259/260/261 AND MCU-14-315/316/317: APRIL AND MAY 2014 MONTHLY SAMPLES

SRNL received two sets of SHT samples (MCU-14-259/260/261 in April 2014 and MCU-14- 315/316/317 in May 2014) for analysis. The samples were analyzed for composition. Both samples have similar chemical composition. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar® L trimming at this time. Since an addition of TiDG and MaxCalix to the SHT was added in early July 2014, the solvent does not require TiDG addition at this time. The current TiDG level (1.5 mM) is above the minimum recommended operating level of 1 mM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a laser Doppler displacement encoder system with ultra-low-noise-level for linear displacement measurement with subnanometer resolution - Final CRADA Report

An U.S. DOE Cooperative Research and Development Agreement (CRADA) between ANL and Optodyne, Inc. has been established to develop a prototype laser Doppler displacement encoder system with ultra-low noise level for linear measurements to sub-nanometer resolution for synchrotron radiation applications. We have improved the heterodyne efficiency and reduced the detector shot noises by proper shielding and adding a low-pass filter. The laser Doppler displacement encoder system prototype demonstrated a ~ 1 nm system output noise floor with single reflection optics. With multiple-pass optical arrangement, 0.1 nm scale closed-loop feedback control is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY19 L2 MRT 6744 Milestone Completion: Digital Time-Resolved Spot Diagnostic (D-TRSD)

This milestone report describes development of the Digital Time-Resolved Spot Diagnostic (D-TRSD) into a functioning diagnostic that has been proven in the laboratory. Laboratory tests complete the MRT 6744 exit criteria with the recording and analysis of a spot size measurement for two consecutive pulses on a two-pulse source. Additional channels will be added in the near future to provide an 84-channel measurement capability. The new modular design is more portable than the previous generations and will be much easier to set up at radiographic facilities across the complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U.S. Domestic Small Modular Reactor Security by Design

U.S. nuclear power facilities face increasing challenges in meeting evolving security requirements caused by evolving and expanding threats while keeping cost reasonable to make nuclear energy competitive. The addition of security features after a facility has been designed and without attention to optimization (the past approach) can lead to cost overruns. Incorporating security in the design process can provide robust, cost effective, and sufficient physical protection systems. The purpose of this work is to develop a framework for the integration of security into the design phase of Small Modular Reactors (SMRs) and the use of modeling and simulation tools to optimize the design of physical protection systems. This effort will intend to integrate security into the design phase of a model SMR that meets current NRC physical protection requirements and provide advanced solutions to improve physical protection and decrease costs. A suite of tools, including SCRIBE3D, PATHTRACE and Blender were used to model a hypothetical generic domestic SMR facility. Physical protection elements such as sensors, cameras, portal monitors, barriers, and guard forces were added to the model based on best practices for physical protection systems. One outsider sabotage scenario was examined with 4-8 adversaries to determine security metrics. This work will influence physical protection system designs and facility designs for U.S. domestic SMRs. The purpose of this project is to demonstrate how a series of experimental and modeling capabilities across the Department of Energy Complex can impact the design of U.S. domestic SMRs and the complete Safeguards and Security by Design (SSBD) for SMRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermodynamic Modeling of Complex Solid Solutions in the Lu-H-N System via Graph Neural Network Accelerated Monte Carlo Simulations

Metal hydrides are important across diverse applications, such as hydrogen storage, batteries, gas sensors, nuclear reactions, and high-temperature superconductivity. Previous computational studies of metal hydrides under extreme pressures, e.g., 𝑂⁡(10 2 ) ⁢GPa, usually treat them as stoichiometric compounds without considering interstitial lattice disorder. As pressures become more moderate in the 𝑂⁡(10 0 ) ⁢GPa and below range, hydrogen disorder at interstitial lattice sites becomes prominent, e.g., in the N-doped Lu hydride that was recently claimed superconducting near 1 GPa. Further adding compositional complexity from alloying and/or multielement interstitial occupation makes elucidating pressure- and temperature-dependent observables intractable by first-principles calculations alone. We therefore propose a lattice graph neural-network surrogate modeling approach to predict configuration- and pressure-dependent equation-of-state properties. Their efficiency permits Monte Carlo simulations to calculate Gibbs energies and pressure-dependent phase diagrams, thereby revealing insights into the synthesis conditions required for achieving desired phase equilibria. We demonstrate this concept for the compositionally complex cubic Lu(H,N,Va) 3 system where three constituents (hydrogen, nitrogen and vacancy) have disordered multielement interstitial occupancies and insights into pressure-dependent phase equilibria are critically needed, e.g., N-doping levels can significantly lower dehydrogenation temperatures and provide a new strategy to optimize hydrogen-storage alloys. This work can improve the thermodynamic understanding of the Lu-H-N system and help rational synthesis of N-doped Lu hydrides, but more generally demonstrates an efficient approach to model pressure-dependent thermodynamics of multicomponent solid solutions.

Monte Carlo methods↗

Assessing the Impurities in Neptunium Metal

A mass scan was previously run in the Q-ICP-MS for the Np metal dissolved samples. Peaks for Ti, Nb, I, Au, Tl, Na, Al, Sn, Ni, Zn, Y, Cr, Pb, K, Fe, Ca, Ta, Th, V, U and Pu were observed. Those elements were isotopically quantified using the HR-ICP-MS. For these determinations, the elements were split in 7 different sets, accordingly to its concentration in the sample and/or possible interferences. For each set of elements, Internal Standard (IS) was added in a similar concentration for the sample. Samples and standards were run both in 300 resolution power (RP) and 4000 RP, in order to evaluate possible interferences (except for actinides, that were run only in 300 RP). It was possible to identify the main sources of impurities, with great precision and accuracy. As the HR-ICP-MS is considered a recent instrument, specially when applied for the analysis of nuclear materials, the method development can be published in peer-reviewed journals. Np metal produced did not achieve the desired purity (which was 99.758% for the elements analyzed). The main impurities were Ta, Fe, Th, U and Pu. This information will help modify the casting process to achieve a higher purity. The maximum achievable purity with our current method is 99.990%. This is being constantly improved, now that we have enough information about the interferences on these elements analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Does Axillary Boost Increase Lymphedema Compared With Supraclavicular Radiation Alone After Breast Conservation?

Purpose: To determine independent predictors of lymphedema (LE) after breast radiotherapy and to quantify added risks of LE from regional node irradiation (RNI). Materials and Methods: A total of 2,579 women with T1-2, N 0-3, M0 breast cancer treated with breast conservation between 1970 and 2005 were studied. A total of 2,169 patients (84%) received radiation to the breast (B), 226 (8.8%) to the breast and supraclavicular LNs (B+SC), and 184 (7.1%) to the breast, supraclavicular LNs, and a posterior axillary boost (B+SC+PAB). Median follow-up was 81 months (range, 3-271). Results: Eighteen percent of patients developed LE. LE risks were as follows: 16% (B), 23% (B+SC), and 31% (B+SC+PAB) (p < 0.0001). LE severity was greater in patients who had RNI (p = 0.0002). On multivariate analysis, RT field (p < 0.0001), obesity index (p = 0.0157), systemic therapy (p = 0.0013), and number of LNs dissected (p < 0.0001) independently predicted for LE. In N1 patients, the addition of a SC to tangents (p < 0.0001) and the addition of a PAB to tangents (p = 0.0017) conferred greater risks of LE, but adding a PAB to B+SC RT did not (p = 0.8002). In the N2 patients, adding a PAB increased the risk of LE 4.5-fold over B+SC RT (p = 0.0011). Conclusions: LE predictors included number of LNs dissected, RNI, obesity index, and systemic therapy. LE risk increased when a SC or PAB were added in the N1 subgroup. In the N2 patients, a PAB increased the risk over B+SC. The decision to boost the axilla must be weighed against the increased risk of LE that it imposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A low phase noise microwave source for atomic spin squeezing experiments in {sup 87}Rb

We describe and characterize a simple, low cost, low phase noise microwave source that operates near 6.800 GHz for agile, coherent manipulation of ensembles of {sup 87}Rb. Low phase noise is achieved by directly multiplying a low phase noise 100 MHz crystal to 6.8 GHz using a nonlinear transmission line and filtering the output with custom band-pass filters. The fixed frequency signal is single sideband modulated with a direct digital synthesis frequency source to provide the desired phase, amplitude, and frequency control. Before modulation, the source has a single sideband phase noise near -140 dBc/Hz in the range of 10 kHz-1 MHz offset from the carrier frequency and -130 dBc/Hz after modulation. The resulting source is estimated to contribute added spin-noise variance 16 dB below the quantum projection noise level during quantum nondemolition measurements of the clock transition in an ensemble 7 x 10{sup 5} {sup 87}Rb atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New X-Ray Spectrometer Developed

X-ray absorption spectroscopy (XAS) and X-ray emission spectroscopy (XES) are useful tools for characterizing numerous properties of a given material. They can give elemental composition, metal oxidation states, spin state, orbital occupancy, and more. A drawback is that these types of measurements have historically needed synchrotron light sources to generate high flux X-ray beams and high-resolution monochromators to provide a monoenergetic excitation source. Synchrotrons are building-sized facilities (often operated in the U.S. by the DOE) and have the scheduling complexities and logistical issues that accompany any large-scale research facility. There are added challenges for scientists wishing to analyze radioactive samples such as plutonium or other actinides. These limitations are now mitigated by a small, “portable” X-ray emission and absorption spectrometers developed by Los Alamos scientists and the University of Washington.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Test Reactor National Scientific User Facility Partnerships

In 2007, the United States Department of Energy designated the Advanced Test Reactor (ATR), located at Idaho National Laboratory, as a National Scientific User Facility (NSUF). This designation made test space within the ATR and post-irradiation examination (PIE) equipment at INL available for use by researchers via a proposal and peer review process. The goal of the ATR NSUF is to provide researchers with the best ideas access to the most advanced test capability, regardless of the proposer's physical location. Since 2007, the ATR NSUF has expanded its available reactor test space, and obtained access to additional PIE equipment. Recognizing that INL may not have all the desired PIE equipment, or that some equipment may become oversubscribed, the ATR NSUF established a Partnership Program. This program enables and facilitates user access to several university and national laboratories. So far, seven universities and one national laboratory have been added to the ATR NSUF with capability that includes reactor-testing space, PIE equipment, and ion beam irradiation facilities. With the addition of these universities, irradiation can occur in multiple reactors and post-irradiation exams can be performed at multiple universities. In each case, the choice of facilities is based on the user's technical needs. Universities and laboratories included in the ATR NSUF partnership program are as follows: (1) Nuclear Services Laboratories at North Carolina State University; (2) PULSTAR Reactor Facility at North Carolina State University; (3) Michigan Ion Beam Laboratory (1.7 MV Tandetron accelerator) at the University of Michigan; (4) Irradiated Materials at the University of Michigan; (5) Harry Reid Center Radiochemistry Laboratories at University of Nevada, Las Vegas; (6) Characterization Laboratory for Irradiated Materials at the University of Wisconsin-Madison; (7) Tandem Accelerator Ion Beam. (1.7 MV terminal voltage tandem ion accelerator) at the University of Wisconsin-Madison; (8) Illinois Institute of Technology (IIT) Materials Research Collaborative Access Team (MRCAT) beamline at Argonne National Laboratory's Advanced Photon Source; and (9) Nanoindenter in the University of California at Berkeley (UCB) Nuclear Engineering laboratory Materials have been analyzed for ATR NSUF users at the Advanced Photon Source at the MRCAT beam, the NIST Center for Neutron Research in Gaithersburg, MD, the Los Alamos Neutron Science Center, and the SHaRE user facility at Oak Ridge National Laboratory (ORNL). Additionally, ORNL has been accepted as a partner facility to enable ATR NSUF users to access the facilities at the High Flux Isotope Reactor and related facilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗