Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Role of interfaces i nthe design of ultra-high strength, radiation damage tolerant nanocomposites

The combination of high strength and high radiation damage tolerance in nanolaminate composites can be achieved when the individual layers in these composites are only a few nanometers thick and contain special interfaces that act both as obstacles to slip, as well as sinks for radiation-induced defects. The morphological and phase stabilities and strength and ductility of these nano-composites under ion irradiation are explored as a function of layer thickness, temperature and interface structure. Magnetron sputtered metallic multilayers such as Cu-Nb and V-Ag with a range of individual layer thickness from approximately 2 nm to 50 nm and the corresponding 1000 nm thick single layer films were implanted with helium ions at room temperature. Cross-sectional Transmission Electron Microscopy (TEM) was used to measure the distribution of helium bubbles and correlated with the helium concentration profile measured vis ion beam analysis techniques to obtain the helium concentration at which bubbles are detected in TEM. It was found that in multilayers the minimum helium concentration to form bubbles (approximately I nm in size) that are easily resolved in through-focus TEM imaging was several atomic %, orders of magnitude higher than that in single layer metal films. This observation is consistent with an increased solubility of helium at interfaces that is predicted by atomistic modeling of the atomic structures of fcc-bcc interfaces. At helium concentrations as high as 7 at.%, a uniform distribution of I nm diameter bubbles results in negligible irradiation hardening and loss of deformability in multi layers with layer thicknesses of a few nanometers. The control of atomic structures of interfaces to produce high helium solubility at interfaces is crucial in the design of nano-composite materials that are radiation damage tolerant. Reduced radiation damage also leads to a reduction in the irradiation hardening, particularly at layer thickness of approximately 5 run and below. The strategies for design of radiation-tolerant structural materials based on the knowledge gained from this work will be discussed.

36 MATERIALS SCIENCE↗

Generation of Picosecond Electron-Bunch Trains with Variable Spacing Using a Multi-Pulse Photocathode Laser

We demonstrate the generation of a train of electron bunches with variable spacing at the Argonne Wakefield Accelerator. The photocathode ultraviolet laser pulse consists of a train of four pulses produced via polarization splitting using two alpha-BBO crystals. The photoemitted electron bunches are then manipulated in a horizontally-bending dogleg with variable longitudinal dispersion. A downstream vertically-deflecting cavity is then used to diagnose the temporal profile of the electron beam. The generation of a train composed of four bunches with tunable spacing is demonstrated. Such a train of bunch could have application to, e.g., the resonant excitation of wakefield in dielectric-lined structures. We have presented preliminary measurements on a simple technique to generate a train of electron bunches with variable separation. In the initial experiment appreciable density modulation down to wavelengths of {approx}1.8 mm (corresponding to a temporal separation of {approx}6 ps) were achieved for a total charge of 0.5 nC. Finding ways to reach smaller separations is being explored with the help of numerical simulations and will be presented elsewhere.

43 PARTICLE ACCELERATORS↗

Adjustable-beam luminaires

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaires with automatic beam controller

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaire

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaires

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Direct imaging of InSb (110)-(1x1) surface grown by molecular beam epitaxy

High-resolution transmission electron microscopy under a profile imaging condition (HR-profile TEM) was employed to determine the structural model for the InSb(110)-(1x1) relaxation surface grown by molecular beam epitaxy (MBE). HR-profile TEM analyses indicate that the chevron model, which is widely accepted for zinc-blende-type III-V(110)-(1x1) surfaces prepared by cleavage, is also applicable to the InSb(110)-(1x1) surface prepared under an Sb-rich MBE condition. The assignment of atomic species (In or Sb) of InSb(110)-(1x1) surfaces was confirmed based on a HR-profile TEM image that captures the connected facets of InSb(110)-(1x1) and InSb(111)B-(2x2). On the basis of the well-known atomic species of InSb(111)B-(2x2), the atomic species of the InSb(110)-(1x1) surface were deduced straightforwardly: the atoms shifted upward and downward at the topmost layer of the InSb(110)-(1x1) surface are Sb and In, respectively. The atomic arrangements of the InSb(110)-(1x1)-InSb(111)B-(2x2) facet determined by HR-profile TEM may represent the atomic arrangements of zinc-blende-type III-V(331)B surfaces.

36 MATERIALS SCIENCE↗

A laboratory experiment to examine the effect of auroral beams on spacecraft charging in the ionosphere

A 2.54 cm diameter conducting electrically isolated Copper sphere is suspended in a low density (10{sup 4} cm{sup -3}), low temperature (T{sub e} = 0.5 eV) Argon plasma, which mimics a spacecraft in an ionospheric plasma. An electron beam with current density of approximately 10{sup -10} A/cm{sup 2} and beam spot of 10.2 cm diameter, which mimics an auroral electron beam, is fired at the sphere while varying the beam energy from 100 eV to 2 keV. The plasma potential in the sheath around the sphere is measured using an emissive probe as the electron beam energy is varied. To observe the effects of the electron beam, the experimental sheath potential profiles are compared to a model of the plasma potential around a spherically symmetric charge distribution in the absence of electron beams. Comparison between the experimental data and the model shows that the sphere is less negative than the model predicts by up to half a volt for beam energies that produce high secondary electron emission from the surface of the sphere. It is shown that this secondary emission can account for changes in potential of spacecraft in the ionosphere as they pass through auroral beams and thus helps to improve interpretations of ionospheric thermal ion distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bunch Profiling Using a Rotating Mask

The current method for measuring profiles of proton bunches in accelerators is severely lacking. One must dedicate a great deal of time and expensive equipment to achieve meaningful results. A new method to complete this task uses a rotating mask with slots of three different orientations to collect this data. By scanning over the beam in three different directions, a complete profile for each bunch is built in just seconds, compared to the hours necessary for the previous method. This design was successfully tested using synchrotron radiation emitted by SPEAR3. The profile of the beam was measured in each of the three desired directions. Due to scheduled beam maintenance, only one set of data was completed and more are necessary to solve any remaining issues. The data collected was processed and all of the RMS sizes along the major and minor axes, as well as the tilt of the beam ellipse were measured.

43 PARTICLE ACCELERATORS↗

TH-C-12A-04: Dosimetric Evaluation of a Modulated Arc Technique for Total Body Irradiation

Purpose: A simplified Total Body Irradiation (TBI) was developed to work with minimal requirements in a compact linac room without custom motorized TBI couch. Results were compared to our existing fixed-gantry double 4 MV linac TBI system with prone patient and simultaneous AP/PA irradiation. Methods: Modulated arc irradiates patient positioned in prone/supine positions along the craniocaudal axis. A simplified inverse planning method developed to optimize dose rate as a function of gantry angle for various patient sizes without the need of graphical 3D treatment planning system. This method can be easily adapted and used with minimal resources. Fixed maximum field size (40×40 cm2) is used to decrease radiation delivery time. Dose rate as a function of gantry angle is optimized to result in uniform dose inside rectangular phantoms of various sizes and a custom VMAT DICOM plans were generated using a DICOM editor tool. Monte Carlo simulations, film and ionization chamber dosimetry for various setups were used to derive and test an extended SSD beam model based on PDD/OAR profiles for Varian 6EX/ TX. Measurements were obtained using solid water phantoms. Dose rate modulation function was determined for various size patients (100cm − 200cm). Depending on the size of the patient arc range varied from 100° to 120°. Results: A PDD/OAR based beam model for modulated arc TBI therapy was developed. Lateral dose profiles produced were similar to profiles of our existing TBI facility. Calculated delivery time and full arc depended on the size of the patient (∼8min/ 100° − 10min/ 120°, 100 cGy). Dose heterogeneity varied by about ±5% − ±10% depending on the patient size and distance to the surface (buildup region). Conclusion: TBI using simplified modulated arc along craniocaudal axis of different size patients positioned on the floor can be achieved without graphical / inverse 3D planning.

60 APPLIED LIFE SCIENCES↗

Ion propulsion system design and throttling strategies for planetary missions

This paper describes recent advances in ion propulsion system design which promise to increase the propulsion system reliability by reducing the overall system complexity. The greatest simplification in the overall propulsion system operation is accomplished through a change in the ion engine throttling strategy. By using three grid optics it is possible to effect engine throttling at a constant beam curent over at least a 3.8 to 1 variation in input power. Throttling at a constant beam current results in a single discharge chamber operating point and eliminates the need for active propellant flow controllers and complex engine throttling software. Detailed mission analysis calculations for a CNSR mission performed using this constant beam current throttling strategy indicate only a small reduction in delivered payload and increase in required propellant relative to a conventional throttling profile based on varying the beam curent.

Garner, Charles E.↗

Radio metric errors due to mismatch and offset between a DSN antenna beam and the beam of a troposphere calibration instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10(exp -14) with a 4-deg beam and 1.3 x 10(exp -l5) for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10(exp -14) over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield↗

Threshold criterion for a space simulation beam-plasma discharge

An experimental and theoretical study of the threshold characteristics of a space simulation beam-plasma discharge with emphasis on density profiles and a density-dependent ignition criterion. The study included various beam-plasma conditions covering beam currents from 8 to 85 mA, beam energies from 0.8 to 2.0 keV, and magnetic fields at 0.9 and 1.5 G. The study included experimental determinations of radial profiles of electron density for each of the selected conditions extending from a low-density, pre-beam-plasma discharge state to a strong beam-plasma discharge condition. The experimental results are shown to agree with detailed model calculations, which consider the beam-plasma discharge to be produced by large-amplitude electron plasma waves resulting from the beam-plasma interaction.

Szuszczewicz, E. P.↗

Comparison of collisional radiative models for edge electron density reconstruction from Li I (2s-2p) emission profiles

Four collisional radiative models (CRMs) for reconstruction of the edge electron density profile from the measured Li I (2s-2p) emission profile of an accelerated lithium beam are compared using experimental data from DIII-D. It is shown for both L- and H-mode plasmas that edge density profiles reconstructed with the CRMs DDD2, ABSOLUT, [Sasaki et al. Rev. Sci. Instrum. 64, 1699 (1993)] and a new model developed at DIII-D agree in a density scan from n{sub e}{sup ped}= (2.0-6.5) Multiplication-Sign 10{sup 19} m{sup -3} within 20%, 20%, <5%, and 40%, respectively, of the pedestal density measured with Thomson scattering. Profile shape and absolute density vary in a scan of the effective ion charge Z{sub eff}= 1-6 up to a factor of two but agree with Thomson data for Z{sub eff}= 1-2 within the error bars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-491: Photon Beam Matching Analysis at Multiple Sites Up to Twelve Years Post Installation

Purpose: To determine if the photon beams associated with several models of accelerators are matched with ‘Golden Beam’ data (VGBD) to assess treatment planning modeling and delivery. Methods: Six accelerators’ photon beams were evaluated to determine if they matched the manufacturer’s (Varian Medical Systems, Inc.) VGBD. Additional direct comparisons of the 6X and 18X beams using the manufacturer’s specification of Basic and Fine beam matching were also performed. The Cseries accelerator models were 21 EX (3), IX (2), and a IX Trilogy, ranging from three to twelve years post installation. Computerized beam scanning was performed (IBA Blue Phantom 2) with 2 CC13 ion chambers in water at 100 cm SSD. Dmax (10 cm2 field size), percentage depth dose (6 cm2, 10 cm2, 20 cm2, and 30 cm2 field sizes) and beam uniformity (10 cm2, 30 cm2 and 40 cm2 field sizes) were evaluated. Results: When comparing the beams with VGBD using the ‘Basic’ matching criteria, all beams were within the specifications ( 1.5mm at dmax, 1% PDD, and 2% Profiles). When considering the “Fine” matching criteria ( 1.5mm at dmax, 0.5% PDD, and 2% Profiles), only three of six 6MV beams and two of six high energy (five 18MV & one 15MV) beams passed. Direct comparisons between accelerators using the Clinac IX (installed 2012) as the reference beam datasets resulted in all 6 MV and 18MV beams meeting both the “Basic” and “Fine” criterion with the exception of two accelerators. Conclusion: Linear accelerators installed up to nine years apart are capable of meeting the manufacturers beam matching criteria for “Basic” matching. Without any adjustments most beams, when evaluated, may meet the “Fine” match criteria. The use of a single dataset (VGBD or designated accelerator reference data) for treatment planning commissioning is acceptable and can provide quality treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-35: An Investigation of the Accuracy of Cervical IMRT Dose Distribution Using 2D/3D Ionization Chamber Arrays System and Monte Carlo Simulation

Purpose: The purpose of this work is to compare the verification results of three solutions (2D/3D ionization chamber arrays measurement and Monte Carlo simulation), the results will help make a clinical decision as how to do our cervical IMRT verification. Methods: Seven cervical cases were planned with Pinnacle 8.0m to meet the clinical acceptance criteria. The plans were recalculated in the Matrixx and Delta4 phantom with the accurate plans parameters. The plans were also recalculated by Monte Carlo using leaf sequences and MUs for individual plans of every patient, Matrixx and Delta4 phantom. All plans of Matrixx and Delta4 phantom were delivered and measured. The dose distribution of iso slice, dose profiles, gamma maps of every beam were used to evaluate the agreement. Dose-volume histograms were also compared. Results: The dose distribution of iso slice and dose profiles from Pinnacle calculation were in agreement with the Monte Carlo simulation, Matrixx and Delta4 measurement. A 95.2%/91.3% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Pinnacle distributions within 3mm/3% gamma criteria. A 96.4%/95.6% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Monte Carlo simulation within 2mm/2% gamma criteria, almost 100% gamma pass ratio within 3mm/3% gamma criteria. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusion: It was shown that Matrixx/Delta4 and Monte Carlo simulation can be used very efficiently to verify cervical IMRT delivery. In terms of Gamma value the pass ratio of Matrixx was little higher, however, Delta4 showed more problem fields. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

60 APPLIED LIFE SCIENCES↗

Experimental investigation of the stimulated Brillouin scattering growth and saturation at 526 and 351 nm for direct drive and shock ignition

We have designed experiments to study the effect of the laser wavelength (0.527 versus 0.351 {mu}m) on the coupling efficiency in plasma conditions relevant to compression and shock ignition (SI) schemes in different intensity regimes. A difficult issue was to produce interaction conditions that are equivalent for the two wavelengths. This was obtained by using plasma preformed from a solid target with a plasma-preforming beam at the same wavelength as the interaction beam. This produced an almost exponential density profile from vacuum to the critical density of the interaction beam in which all interaction mechanisms are taken into account. The growth and saturation of stimulated Brillouin scattering (SBS) have been measured at the two wavelengths, in backward as well as in near-backward directions. We have found that the SBS intensity threshold is {approx}1.5 times higher at 3{omega} than at 2{omega} in agreement with the I{lambda} dependence of the SBS gain. The SBS behaviour is very well reproduced by the linear calculations of the postprocessor PIRANAH, giving us confidence that we have a good control of the relevance of the experimental conditions for the study of the laser wavelength effect on laser-plasma coupling. When SBS reaches the saturation regime, same levels of reflectivity are measured at 2 and 3{omega}. Numerical simulations were performed with the paraxial code HERA to study the contribution of the fluid mechanisms in the saturation of SBS, showing that pump depletion and interplay with filamentation are likely to be the most important processes in SBS saturation for these conditions. This scenario also applies to the SBS of shock ignition high-intensity beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗