Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extrinsic calibration of a single-point laser rangefinder and single camera

We present a new method for calibrating a single-point laser rangefinder and single camera because the combination of a cheap single-point laser range finder (LRF) and a camera has become increasingly helpful in recent industrial applications. In order to effectively use the date from the camera and LRF, it is important to know their relative position and orientation from each other. In this paper, a robust extrinsic calibration method for determining the position and direction of the LRF with respect to the camera is proposed. Due to the spot of the single-point LRF we commonly use is mostly invisible, infrared camera is utilized to detect laser spot and then establish the position relationship between visible light camera and infrared camera to calibrate the extrinsic parameters. Experimental results demonstrate that the proposed method can calibrate the extrinsic parameters with high precision and effectively.

42 ENGINEERING↗

The on-orbit calibration of the Fermi Large Area Telescope

The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope began its on-orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization of trigger signals, optimization of delays for latching data, determination of detector thresholds, gains and responses, evaluation of the perimeter of the South Atlantic Anomaly (SAA), measurements of live time, of absolute time, and internal and spacecraft boresight alignments. Here in this work, we describe on-orbit calibration results obtained using known astrophysical sources, galactic cosmic rays, and charge injection into the front-end electronics of each detector. Instrument response functions will be described in a separate publication. This paper demonstrates the stability of calibrations and describes minor changes observed since launch. Lastly, these results have been used to calibrate the LAT datasets to be publicly released in August 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic Modeling of Overtime Occupancy and Its Application in Building Energy Simulation and Calibration

Overtime is a common phenomenon around the world. Overtime drives both internal heat gains from occupants, lighting and plug-loads, and HVAC operation during overtime periods. Overtime leads to longer occupancy hours and extended operation of building services systems beyond normal working hours, thus overtime impacts total building energy use. Current literature lacks methods to model overtime occupancy because overtime is stochastic in nature and varies by individual occupants and by time. To address this gap in the literature, this study aims to develop a new stochastic model based on the statistical analysis of measured overtime occupancy data from an office building. A binomial distribution is used to represent the total number of occupants working overtime, while an exponential distribution is used to represent the duration of overtime periods. The overtime model is used to generate overtime occupancy schedules as an input to the energy model of a second office building. The measured and simulated cooling energy use during the overtime period is compared in order to validate the overtime model. A hybrid approach to energy model calibration is proposed and tested, which combines ASHRAE Guideline 14 for the calibration of the energy model during normal working hours, and a proposed KS test for the calibration of the energy model during overtime. The developed stochastic overtime model and the hybrid calibration approach can be used in building energy simulations to improve the accuracy of results, and better understand the characteristics of overtime in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A truncated Levenberg-Marquardt algorithm for the calibration of highly parameterized nonlinear models

We propose a modification to the Levenberg-Marquardt minimization algorithm for a more robust and more efficient calibration of highly parameterized, strongly nonlinear models of multiphase flow through porous media. The new method combines the advantages of truncated singular value decomposition with those of the classical Levenberg-Marquardt algorithm, thus enabling a more robust solution of underdetermined inverse problems with complex relations between the parameters to be estimated and the observable state variables used for calibration. The truncation limit separating the solution space from the calibration null space is re-evaluated during the iterative calibration process. In between these re-evaluations, fewer forward simulations are required, compared to the standard approach, to calculate the approximate sensitivity matrix. Truncated singular values are used to calculate the Levenberg-Marquardt parameter updates, ensuring that safe small steps along the steepest-descent direction are taken for highly correlated parameters of low sensitivity, whereas efficient quasi-Gauss-Newton steps are taken for independent parameters with high impact. The performance of the proposed scheme is demonstrated for a synthetic data set representing infiltration into a partially saturated, heterogeneous soil, where hydrogeological, petrophysical, and geostatistical parameters are estimated based on the joint inversion of hydrological and geophysical data.

54 ENVIRONMENTAL SCIENCES↗

Calibrating uncertain parameters in melt pool simulations of additive manufacturing

Melt pool scale numerical modeling of additive manufacturing (AM) processes can provide predictive capabilities and theoretical insight into the process-property-structure-performance relationships for AM parts. Despite capabilities of numerical models to solve complex multi-physics problems, it is often important to consider a tradeoff between detailed physics and computational cost. Therefore, sources of uncertainty in both experimental conditions and the parameters needed for modeling require models to be validated against empirical evidence. Here, a method is proposed to calibrate uncertain parameters used in continuum-scale melt pool models for powder bed fusion (PBF) AM. Both a simplified heat transfer model and a heat transfer and fluid flow model were investigated. A surrogate model and Markov chain-based optimization algorithm calibrated melt pool geometry for models within experimental variation of the target melt pool width and depth from the NIST AM-Bench 2018-02 dataset. The melt pool temperature distributions, solidification parameters, and simulated multi-layer solidification microstructures were compared between the two models. Similar results from both models indicate that calibrated, lower fidelity numerical models may be used in place of higher fidelity models to generate melt pool solidification data. Finally, these calibrated models therefore enable lower computational cost melt pool simulations without a noticeable decrease in simulation accuracy for grain-scale microstructure simulations.

36 MATERIALS SCIENCE↗

Using Willingness to Pay to Forecast the Adoption of Solar Photovoltaics: A ''Parameterization + Calibration'' Approach

Distributed energy resources, such as rooftop solar photovoltaics (PV), are likely to comprise a substantial fraction of new generation capacity in the United States. However, forecasting technology adoption based on people's willingness to pay (WTP) faces two major challenges: the stated-intention and omitted-variable biases. Previous solar adoption literature has neglected to address these two biases altogether. Here, we adopt a 'parameterization + calibration' approach to address both biases and estimate customers' WTP for PV. After collecting survey data on respondents' WTP for adopting PV, we characterize its empirical cumulative density function using a gamma distribution. We further calibrate the gamma distribution parameters using a national distributed PV adoption simulation model, finding the parameters that produce the best fit between simulated and historic solar adoption. We then show that the calibrated gamma distribution improves the raw WTP data after correcting for the two biases. Finally, we use our optimally-calibrated WTP to forecast market demand for residential PV at the county-level of the United States in 2020. Improving estimates of customer willingness to pay has significant implications for policy directly, e.g. estimating the effect of a proposed policy on technology adoption, and other regulatory processes that use forecasting, e.g. integrated resource planning.

14 SOLAR ENERGY↗

Model calibration and optimization of a post-combustion CO 2 WAG pilot in a mature oil field

A carbon dioxide (CO 2 ) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO 2 flood in the West Ranch Field as part of the Petra Nova project, the world's largest postcombustion CO 2 capture and utilization initiative. With a fluvial formation geology, this is a challenging and novel application of CO 2 enhanced oil recovery. The aim of this study is two-fold. First, to build a predictive dynamic model that incorporates the data acquired during the pilot operation. Second, to utilize this model to provide guidance for optimal design for a field-wide CO 2 EOR operation. Our study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. Next, local permeability field is fine-tuned using a streamline-based method to match CO 2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO 2 recovery as a fraction of the injected CO 2 . Sensitivity studies were conducted using the calibrated pilot model to evaluate the effects of various operational parameters. Finally, we performed a Design of Experiment based multi-objective optimization of the CO 2 WAG processes using the influential operational parameters identified from the sensitivity analysis.

02 PETROLEUM↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

The detector calibration system for the CUORE cryogenic bolometer array

The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of 130 Te and other rare events. The CUORE detector consists of 988 TeO 2 bolometers operated underground at 10 mK in a dilution refrigerator at the Laboratori Nazionali del Gran Sasso. Candidate events are identified through a precise measurement of their energy. The absolute energy response of the detectors is established by the regular calibration of each individual bolometer using gamma sources. The close-packed configuration of the CUORE bolometer array combined with the extensive shielding surrounding the detectors requires the placement of calibration sources within the array itself. The CUORE Detector Calibration System is designed to insert radioactive sources into and remove them from the cryostat while respecting the stringent heat load, radiopurity, and operational requirements of the experiment. In conclusion, this paper describes the design, commissioning, and performance of this novel source calibration deployment system for ultra-low-temperature environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Majorana Demonstrator calibration system

The Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-ton 76 Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this study, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration technique for rotating PCB coil magnetic field sensors

A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without main field suppression are compared in order to simultaneously determine both the PCB rotation radius and the transverse offset of its plane from rotation center. The accuracy of planar wire placement on the PCB boards is exploited to create loops highly precise in area which rotate at different radii. Such an area reproducibility and circuit geometry allow the suppression of the fundamental field, enabling the calibration, as well as improving signal resolution and mitigating vibration effects. Lastly, the calibration can be performed dynamically, in-situ during measurements. Calibration accuracy is validated experimentally by referencing the PCB positions with a Coordinate Measuring Machine (CMM).

43 PARTICLE ACCELERATORS↗

High vacuum measurements and calibrations, molecular flow fluid transient effects

High vacuum pressure measurements and calibrations below 1 × 10 -8 Torr are problematic. Specifically, measurement accuracies change drastically for vacuum gauges when pressures are suddenly lowered in vacuum systems. How can gauges perform like this? A brief system description is first required to answer this question. Calibrations were performed using a vacuum calibration chamber with attached vacuum gauges. To control chamber pressures, vacuum pumps decreased the chamber pressure while nitrogen tanks increased the chamber pressure. By balancing these opposing pressures, equilibrium in the chamber was maintained at selected set point pressures to perform calibrations. When pressures were suddenly decreased during set point adjustments, a sudden rush of gas from the chamber also caused a surge of gas from the gauges to decrease the pressures in those gauges. Gauge pressures did not return to equilibrium as fast as chamber pressures due to the sparse distribution of gas molecules in the system. This disparity in the rate of pressure changes caused the pressures in different gauges to be different than expected. This discovery was experimentally proven to show that different gauge designs return to equilibrium at different rates, and that gauge accuracies vary for different gauge designs due to fluid transients in molecular flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model calibration and validation for OFMSW and sewage sludge co-digestion reactors

Highlights: > Disintegration is the limiting step of the anaerobic co-digestion process. > Disintegration kinetic constant does not depend on the waste particle size. > Disintegration kinetic constant depends only on the waste nature and composition. > The model calibration can be performed on organic waste of any particle size. - Abstract: A mathematical model has recently been proposed by the authors to simulate the biochemical processes that prevail in a co-digestion reactor fed with sewage sludge and the organic fraction of municipal solid waste. This model is based on the Anaerobic Digestion Model no. 1 of the International Water Association, which has been extended to include the co-digestion processes, using surface-based kinetics to model the organic waste disintegration and conversion to carbohydrates, proteins and lipids. When organic waste solids are present in the reactor influent, the disintegration process is the rate-limiting step of the overall co-digestion process. The main advantage of the proposed modeling approach is that the kinetic constant of such a process does not depend on the waste particle size distribution (PSD) and rather depends only on the nature and composition of the waste particles. The model calibration aimed to assess the kinetic constant of the disintegration process can therefore be conducted using organic waste samples of any PSD, and the resulting value will be suitable for all the organic wastes of the same nature as the investigated samples, independently of their PSD. This assumption was proven in this study by biomethane potential experiments that were conducted on organic waste samples with different particle sizes. The results of these experiments were used to calibrate and validate the mathematical model, resulting in a good agreement between the simulated and observed data for any investigated particle size of the solid waste. This study confirms the strength of the proposed model and calibration procedure, which can thus be used to assess the treatment efficiency and predict the methane production of full-scale digesters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Simulation of the motional Stark effect diagnostic gas-filled torus calibration

Many motional Stark effect diagnostics around the world make use of a calibration procedure in which the observed neutral beam is injected into a gas-filled torus with known vacuum fields. The instrument is calibrated by reconciling measured angles with vacuum magnetic reconstructions through a range of pitch angles. This in situ gas-filled torus calibration most closely approximates the working conditions of the diagnostic and includes effects such as beam and viewing geometries, beam voltages, Faraday and stress induced birefringence (in most cases) of the transmissive optics, as well as the polarimeter response. However, secondary neutrals, produced after ionization then reneutralization of a beam neutral, have been found to contaminate measured angles by emitting Balmer alpha with similar Doppler shifts and Stark polarizations as beam neutrals, but with different polarization angles. Simulation results that show spectral and angle behavior versus calibration parameters such as fill gas pressure will be presented. Data from NSTX and C-Mod will be compared to simulations results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated system for the calibration of magnetometers

A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical University. There are three axes of rotation in this design (compared to two axes in the previous version). The addition of the third axis allows us to calibrate more complex devices. An electronic compass based on a vector fluxgate magnetometer and micro electro mechanical systems (MEMS) accelerometer is one example. The new platform can also be used to evaluate the parameters of the compass in all possible variations in azimuth, pitch, and roll. The system is based on piezoelectric motors, which are placed on a platform made of aluminum, brass, plastic, and glass. Position sensing is accomplished through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A direct micropipette-based calibration method for atomic force microscope cantilevers

In this report, we describe a direct method for calibrating atomic force microscope (AFM) cantilevers with the micropipette aspiration technique (MAT). A closely fitting polystyrene bead inside a micropipette is driven by precisely controlled hydrostatic pressures to apply known loads on the sharp tip of AFM cantilevers, thus providing a calibration at the most functionally relevant position. The new method is capable of calibrating cantilevers with spring constants ranging from 0.01 to hundreds of newtons per meter. Under appropriate loading conditions, this new method yields measurement accuracy and precision both within 10%, with higher performance for softer cantilevers. Furthermore, this method may greatly enhance the accuracy and precision of calibration for colloidal probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗