Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Sieving Hydrogen Isotopes via Machine Learning Assisted Chemical Vapor Deposition (CVD) of High‐Quality Monolayer Hexagonal Boron Nitride (h‐BN) on Iron Foils

Atomically thin two-dimensional (2D) ceramics, such as monolayer hexagonal boron nitride (h-BN), present potential for disruptive advances in separations. However, sub-atomic scale separation of hydrogen isotopes (H + /D + ) require near pristine 2D material membranes, and scalable synthesis of such high-quality h-BN comparable to mechanically exfoliated crystals remains a significant challenge. Here, we report a scalable Fe-catalyzed chemical vapor deposition (CVD) process for bottom-up synthesis of large-area, high-quality monolayer h-BN films, overcoming key limitations of conventional ammonia-based routes. By leveraging mechanistic insights and higher CVD temperatures, we suppress multilayer formation and achieve uniform monolayer h-BN coverage on commercially available Fe foils. Machine learning enables systematic exploration of the complex, multi-dimensional CVD parameter space (growth time, temperature, precursor temperature, multilayer faction, coverage), providing data-driven approaches to visualize and identify process regimes facilitating predominantly monolayer h-BN growth with minimal secondary nuclei/ad-layers. The optimized Fe-catalyzed CVD h-BN membranes show high-quality as observed by proton/deuteron (H + /D + ) selectivity ≈8.45, approaching the highest quality benchmark of mechanically exfoliated h-BN (H + /D + selectivity ≈10) as well as significantly outperforming Cu-catalyzed CVD h-BN membranes (H + /D + selectivity ≈3.62, control selectivity ≈1.7). Our work provides a scalable cost-effective route for high-quality monolayer h-BN synthesis for sub-atomic scale separations (H + /D + ) and demonstrates the broader potential of machine learning-guided optimization of CVD for advancing synthesis of 2D materials.

36 MATERIALS SCIENCE↗

OPEN CLUSTERS IN THE MILKY WAY OUTER DISK: NEWLY DISCOVERED AND UNSTUDIED CLUSTERS IN THE SPITZER GLIMPSE-360, CYG-X, AND SMOG SURVEYS

Open stellar clusters are extremely valuable probes of Galactic structure, star formation, kinematics, and chemical abundance patterns. Near-infrared (NIR) data have enabled the detection of hundreds of clusters hidden from optical surveys, and mid-infrared (MIR) data are poised to offer an even clearer view into the most heavily obscured parts of the Milky Way. We use new MIR images from the Spitzer GLIMPSE-360, Cyg-X, and SMOG surveys to visually identify a large number of open cluster candidates in the outer disk of the Milky Way (65 Degree-Sign < l < 265 Degree-Sign ). Using NIR color-magnitude diagrams, stellar isochrones, and stellar reddening estimates, we derive cluster parameters (metallicity, distance, reddening) for those objects without previous identification and/or parameters in the literature. In total, we present coordinates and sizes of 20 previously unknown open cluster candidates; for 7 of these we also present metallicity, distance, and reddening values. In addition, we provide the first estimates of these values for nine clusters that had been previously cataloged. We compare our cluster sizes and other derived parameters to those in the open cluster catalog of Dias et al. and find strong similarities except for a higher mean reddening for our objects, which signifies our increased detection sensitivity in regions of high extinction. The results of this cluster search and analysis demonstrate the ability of MIR imaging and photometry to augment significantly the current census of open clusters in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of Transport Phenomena in Bubble Column Reactors

The production of carbon and hydrogen from methane is a viable pathway for monetizing the vast reserves of US natural gas. Liquid (metals and/or salts) bubble column reactors operating at temperatures greater than 1000° C allow the conversion of methane into hydrogen without CO 2 emission. The low-density carbon floats on top of the liquid surface, allowing an easier removal, compared to other reactor concepts for methane pyrolysis. In this current report, we present results from simulations of transport phenomena in a liquid bubble column reactor. The goal is to investigate and understand parameters that are crucial for bubble column reactor design and scale up. The report presents the formulation and numerical methods used in the multiphase direct numerical simulation software, Quilt. This software was validated for the bubbly flow using numerical and physics based test problems. Quilt was then used to perform simulations of the bubble column reactor as a parametric study, varying the bubble injection parameters. The simulations were visualized for qualitative analysis and followed up with a quantitative analysis. The effect of injection parameters on various quantitative measures of the bubble residence time, interfacial area and motion through the column are presented.

03 NATURAL GAS↗

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗

SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

60 APPLIED LIFE SCIENCES↗

Intense Pulse Light Annealing of Perovskite Photovoltaics Using Gradient Flashes

Perovskite solar cells (PSCs) have been fabricated through high-speed and low-cost depositions but often require long annealing. Intense pulse light (IPL) can anneal thin films in seconds after deposition by inducing very high temperatures lasting for milliseconds, and multiple flashes can be used to tune the temperature profile. In this study, a gradient flash annealing (GFA) approach is introduced and compared to uniform flash annealing (UFA) by investigating the crystallinity, morphology, and phase evolution of the CH 3 NH 3 PbI 3 perovskite films and their impact on PSC performance. Unlike UFA, low-intensity pulsed irradiation during the pre-annealing stage of GFA played a significant role on enhancing the PSC performance by forming pure-phase CH 3 NH 3 PbI 3 perovskite thin films with superior morphology and high crystallinity. To understand the kinetics, a transient thermal simulation using ANSYS was developed and confirmed with an experimental setup. The results combined with microscopy and spectrophotometry were used to visualize how duration, delay time, photon flux, and flash count parameters participated in crystallization, phase, and morphology evolution. The IPL annealing induced rapid surface temperature increase, reaching as high as 800 °C, while produced well-developed and bound perovskite grains without any surface defects in an uncontrolled ambient environment with high humidity (>60%). The study resulted in PSCs with maximum efficiency and fill factor of 9.27 and 69.92% for the UFA and 11.75 and 68% when annealed through the GFA approach, respectively. Lastly, this work utilized IPL as the sole thermal source for post-deposition annealing to rapidly fabricate efficient PSCs in only 10 s, which opens the pathway for high-speed, low-cost, and large-scale automated fabrication of perovskite photovoltaics and semiconductors.

14 SOLAR ENERGY↗

Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of H{sub {alpha}} and the H{sub {beta}} lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A proximity‐based image‐processing algorithm for colloid assignment in segmented multiphase flow datasets

Summary Colloidal transport and deposition are of both environmental and engineering importance. Easier access to x‐ray microtomography (XMT) coupled with improved imaging resolution has made XMT a unique and viable tool for visualizing and quantifying these processes. Currently, there is scant information in the literature addressing colloid segmentation and analysis in saturated and unsaturated porous media, in particular related to spatial partitioning of colloids. To support this need, an approach to assign segmented colloidal particles and aggregates to different partitioning classes based on their proximity to different phases is presented here. The method uses different markers for each attachment site (e.g. wetting‐nonwetting phase interfaces). An example XMT dataset from a drainage experiment is used to demonstrate the efficacy of the image processing algorithms. Flow conditions, and fluid and colloid properties, can thus be compared to the behaviour of colloids within the porous medium. This algorithm can help elucidate colloidal deposition mechanisms and the importance of different attachment sites, explore the importance of fluid properties, as well as the arrangement and shape of the colloids.

BRUECK, C. L.↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes of Transcatheter Arterial Embolisation for Chronic Knee Pain: Mild-to-Moderate Versus Severe Knee Osteoarthritis

Purpose: This retrospective study was conducted to compare the clinical outcomes of transcatheter arterial embolisation for chronic knee pain in patients with mild-to-moderate versus severe knee osteoarthritis. Materials and Methods: This study included patients (n = 41) who were refractory to conservative treatments and who underwent transcatheter arterial embolisation using imipenem/cilastatin sodium between June 2017 and July 2018. A total of 71 knees, including 30 bilateral cases, were treated and categorised into two groups according to the Kellgren–Lawrence grade: mild-to-moderate osteoarthritis (n = 59, Kellgren–Lawrence grade 1–3) and severe osteoarthritis (n = 12, Kellgren–Lawrence grade 4). The clinical outcomes were measured by the visual analogue scale score. Results: There were no significant differences in age, body mass index or baseline visual analogue scale scores between the two groups. The mean visual analogue scale scores in the mild-to-moderate osteoarthritis group were significantly decreased at 1 day, 1 week, 1 month, 3 months, and 6-months (5.5 at baseline vs. 3.2, 3.1, 2.9, 2.2, and 1.9, after treatment; all P = .00). These improvements were maintained at a mean of 10 ± 3 months (range 6–19 months) post-treatment. The visual analogue scale scores were significantly decreased in the severe osteoarthritis group for 1 month post-treatment (6.3 at baseline vs. 4.1, 4.1, and 4.4 at 1 day, 1 week, and 1 month; all P < .01). However, a decrease in pain was not statistically significant from 3 to 6 months (5.4 and 5.9 at 3 months and 6 months, respectively). Conclusion: Transcatheter arterial embolisation effectively relieved pain in patients with mild-to-moderate osteoarthritis. In patients with severe osteoarthritis, pain severity decreased for 1 month but gradually increased to the initial severity score within 3 months. Level of Evidence: 4, Case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

STRONG LENS TIME DELAY CHALLENGE. II. RESULTS OF TDC1

We present the results of the first strong lens time delay challenge. The motivation, experimental design, and entry level challenge are described in a companion paper. This paper presents the main challenge, TDC1, which consisted of analyzing thousands of simulated light curves blindly. The observational properties of the light curves cover the range in quality obtained for current targeted efforts (e.g., COSMOGRAIL) and expected from future synoptic surveys (e.g., LSST), and include simulated systematic errors. Seven teams participated in TDC1, submitting results from 78 different method variants. After describing each method, we compute and analyze basic statistics measuring accuracy (or bias) A, goodness of fit χ{sup 2}, precision P, and success rate f. For some methods we identify outliers as an important issue. Other methods show that outliers can be controlled via visual inspection or conservative quality control. Several methods are competitive, i.e., give |A| < 0.03, P < 0.03, and χ{sup 2} < 1.5, with some of the methods already reaching sub-percent accuracy. The fraction of light curves yielding a time delay measurement is typically in the range f = 20%-40%. It depends strongly on the quality of the data: COSMOGRAIL-quality cadence and light curve lengths yield significantly higher f than does sparser sampling. Taking the results of TDC1 at face value, we estimate that LSST should provide around 400 robust time-delay measurements, each with P < 0.03 and |A| < 0.01, comparable to current lens modeling uncertainties. In terms of observing strategies, we find that A and f depend mostly on season length, while P depends mostly on cadence and campaign duration.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study

Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yielding 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility.

60 APPLIED LIFE SCIENCES↗

Isolation and characterization of two cellulose morphology mutants of Gluconacetobacter hansenii ATCC23769 producing cellulose with lower crystallinity

Gluconacetobacter hansenii , a Gram-negative bacterium, produces and secrets highly crystalline cellulose into growth medium, and has long been used as a model system for studying cellulose synthesis in higher plants. Cellulose synthesis involves the formation of β-1,4 glucan chains via the polymerization of glucose units by a multi-enzyme cellulose synthase complex (CSC). These glucan chains assemble into ordered structures including crystalline microfibrils. AcsA is the catalytic subunit of the cellulose synthase enzymes in the CSC, and AcsC is required for the secretion of cellulose. However, little is known about other proteins required for the assembly of crystalline cellulose. To address this question, we visually examined cellulose pellicles formed in growth media of 763 individual colonies of G. hansenii generated via Tn5 transposon insertion mutagenesis, and identified 85 that produced cellulose with altered morphologies. X-ray diffraction analysis of these 85 mutants identified two that produced cellulose with significantly lower crystallinity than wild type. The gene disrupted in one of these two mutants encoded a lysine decarboxylase and that in the other encoded an alanine racemase. Solid-state NMR analysis revealed that cellulose produced by these two mutants contained increased amounts of non-crystalline cellulose and monosaccharides associated with non-cellulosic polysaccharides as compared to the wild type. Monosaccharide analysis detected higher percentages of galactose and mannose in cellulose produced by both mutants. Field emission scanning electron microscopy showed that cellulose produced by the mutants was unevenly distributed, with some regions appearing to contain deposition of non-cellulosic polysaccharides; however, the width of the ribbon was comparable to that of normal cellulose. As both lysine decarboxylase and alanine racemase are required for the integrity of peptidoglycan, we propose a model for the role of peptidoglycan in the assembly of crystalline cellulose.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Tank 38H (HTF-38-22-91, -92) and Tank 43H (HTF-43-22-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Way to Discover Strong Gravitational Lenses: Pairwise Spectroscopic Search from DESI DR1

We present a new method to search for strong gravitational-lensing systems by pairing spectra that are close together on the sky in a spectroscopic survey. We visually inspect 26,621 spectra in the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 that are selected in this way. We further inspect the 11,848 images corresponding to these spectra in the DESI Legacy Imaging Surveys Data Release 10, and obtain 2046 conventional strong gravitational lens candidates, of which 1906 are new. This constitutes the largest sample of lens candidates identified to date in spectroscopic data. Besides the conventional candidates, we identify a new class of systems that we term “dimple lenses.” These systems have a low-mass foreground galaxy as a lens, typically smaller in angular extent and fainter compared with the lensed background source galaxy, producing subtle surface brightness indentations in the latter. We report the discovery of 318 of these “dimple lens” candidates. We suspect that these represent dwarf galaxy lensing. With follow-up observations, they could offer a new avenue to test the cold dark matter model by probing their mass profiles, stellar mass–halo mass relation, and halo mass function for M Halo ≲ 10 13 M ⊙ . Thus, in total, we report 2164 new lens candidates. Our method demonstrates the power of pairwise spectroscopic analysis and provides a pathway complementary to imaging-based and single-spectrum lens searches.

Hsu, Yuan-Ming 許淵明 [National Taiwan University, Ta↗

Unravelling Magnetic Nanochain Formation in Dispersion for In Vivo Applications

Self-assembly of iron oxide nanoparticles (IONPs) into 1D chains is appealing, because of their biocompatibility and higher mobility compared to 2D/3D assemblies while traversing the circulatory passages and blood vessels for in vivo biomedical applications. In this work, parameters such as size, concentration, composition, and magnetic field, responsible for chain formation of IONPs in a dispersion as opposed to spatially confining substrates, are examined. In particular, the monodisperse 27 nm IONPs synthesized by an extended LaMer mechanism are shown to form chains at 4 mT, which are lengthened with applied field reaching 270 nm at 2.2 T. The chain lengths are completely reversible in field. Using a combination of scattering methods and reverse Monte Carlo simulations the formation of chains is directly visualized. The visualization of real-space IONPs assemblies formed in dispersions presents a novel tool for biomedical researchers. This allows for rapid exploration of the behavior of IONPs in solution in a broad parameter space and unambiguous extraction of the parameters of the equilibrium structures. Additionally, it can be extended to study novel assemblies formed by more complex geometries of IONPs.

36 MATERIALS SCIENCE↗

Nanoparticle-embedded nanofibers in highly permselective thin-film nanocomposite membranes for forward osmosis

Here we report a scalable approach to fabricate osmotic membranes with high permselectivity based on nanocomposite of mesoporous silica nanoparticles and nanofibers by electrospinning. Transmission electron microscopy (TEM) images provide visualization of dispersed and clustered nanoparticles embedding within or at the surface of nanofibers. Energy-dispersive X-ray (EDX) point analysis confirms the chemical identity of the nanocomposite structure. Brunauer-Emmett-Teller (BET) analyses show a 75-fold increase in specific surface area when 15% of silica nanoparticles were integrated into polyacrylonitrile nanofibrous mats. Mechanical strength tests show that even at high load of silica nanoparticles, e.g. 15 wt%, the mechanical integrity of the membranes was maintained. Incorporating nanoparticles into nanofibrous mats enhanced their water uptake up to two times. In osmotic transport studies, we observed an outstanding permselectivity of our membranes compared to ones reported in literature. Our membranes show a remarkable 7-fold and 3.5-fold enhancements in osmotic water permeability and water/sodium chloride selectivity, respectively, compared to standard commercial forward osmosis membranes. These results suggest a pathway to develop scalable, high performance osmotic membranes and to further study the predominant mechanism governing transport behaviors of water and solute across nanomaterials interfaces.

42 ENGINEERING↗

Technical overview of the millimeter-wave imaging reflectometer on the DIII-D tokamak (invited)

The two-dimensional mm-wave imaging reflectometer (MIR) on DIII-D is a multi-faceted device for diagnosing electron density fluctuations in fusion plasmas. Its multi-channel, multi-frequency capabilities and high sensitivity permit visualization and quantitative diagnosis of density perturbations, including correlation length, wavenumber, mode propagation velocity, and dispersion. The two-dimensional capabilities of MIR are made possible with 12 vertically separated sightlines and four-frequency operation (corresponding to four radial channels). The 48-channel DIII-D MIR system has a tunable source that can be stepped in 500 μs increments over a range of 56 to 74 GHz. An innovative optical design keeps both on-axis and off-axis channels focused at the cutoff surface, permitting imaging over an extended poloidal region. The integrity of the MIR optical design is confirmed by comparing Gaussian beam calculations to laboratory measurements of the transmitter beam pattern and receiver antenna patterns. Measurements are presented during the density ramp of a plasma discharge to demonstrate unfocused and focused MIR signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗