Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Multifrequency continuous wave terahertz spectroscopy for absolute thickness determination

We present a tunable multifrequency continuous wave terahertz spectrometer based on two laser diodes, photoconductive antennas, and a coherent detection scheme. The system is employed to determine the absolute thickness of samples utilizing a proposed synthetic difference frequency method to circumvent the 2pi uncertainty known from conventional photomixing systems while preserving a high spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thrust Generation with Low-Power Continuous-Wave Laser and Aluminum Foil Interaction

The micro-newton thrust generation was observed through low-power continuous-wave laser and aluminum foil interaction without any remarkable ablation of the target surface. To evaluate the thrust characteristics, a torsion-balance thrust stand capable for the measurement of the thrust level down to micro-Newton ranges was developed. In the case of an aluminum foil target with 12.5 micrometer thickness, the maximum thrust level was 15 micro-newtons when the laser power was 20 W, or about 0.75 N/MW. It was also found that the laser intensity, or laser power per unit area, irradiated on the target was significantly important on the control of the thrust even under the low-intensity level.

36 MATERIALS SCIENCE↗

Continuous distribution of defect states and band gap narrowing in neutron irradiated GaAs

We find that fast neutron irradiated n- and p-GaAs diodes both show a broad feature in deep level transient spectroscopy (DLTS) previously studied primarily in n-GaAs and termed the ''U-band.'' The high temperature edge of the broad DLTS feature cuts off at the same temperature in both n- and p-GaAs suggesting that the cut off is due to the DLTS behavior expected for a continuous density of defect states that spans midgap. The band gap implied by the DLTS midgap cut off is 1.36 eV, as compared to the bulk GaAs band gap 1.52 eV. Band gap narrowing is consistent with previous measurements of lattice expansion in neutron irradiated GaAs. This leads to a model of defect cascades that are regions of narrowed band gap with defect levels that are inhomogeneously broadened. We observe, in addition, that the damage cascades are surrounded by large Coulomb barriers that prevent the complete filling of traps in the damaged regions.

36 MATERIALS SCIENCE↗

Simulation and Experiment on Direct Continuous Casting Process of Lead Frame Copper Alloy

Direct Continuous Casting (D.C.C) is an important method in casting lead frame copper alloy. In this paper, numerical simulation is adopted to investigate the casting process in order to optimize the D.C.C technical parameters, such as the casting temperature, casting speed and cooling intensity. According to the numerical results, the reasonable parameters are that the casting temperature is between 1413 Kapprox1413 K, the casting speed is between 8 m/happrox10 m/h and the speed of cooling water is between 4.2 m/sapprox4.6 m/s. And the depth of liquid-solid boundary is measured in different casting temperature and casting speed by experiments. The results show the actual measurements have a little deviation with the numerical simulation. The results of numerical simulation provide the significant reference to the actual experiments.

36 MATERIALS SCIENCE↗

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

43 PARTICLE ACCELERATORS↗

Note: A modular and robust continuous supersonic expansion discharge source

A direct current discharge has been coupled with a continuous supersonic expansion to provide a source of rotationally cold molecular ions for gas phase spectroscopy. Constructed primarily of machinable ceramic and stainless steel, this source design is modular, customizable, and robust. Its performance has been assessed by recording transitions within the {nu}{sub 2} fundamental band of H{sub 3}{sup +} using cavity ringdown spectroscopy to determine the rotational temperature of ions produced in the free-jet expansion. Temperature and column density were recorded as a function of discharge current as the source was operated over a period of 200 h. Observed temperatures ranged between 50-110 K, and the ion column densities between 8x10{sup 10} and 2x10{sup 12} cm{sup -2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous-time random walk as a guide to fractional Schroedinger equation

We argue that the continuous-time random walk approach may be a useful guide to extend the Schroedinger equation in order to incorporate nonlocal effects, avoiding the inconsistencies raised by Jeng et al. [J. Math. Phys. 51, 062102 (2010)]. As an application, we work out a free particle in a half space, obtaining the time dependent solution by considering an arbitrary initial condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous-wave laser annealing of Si-rich oxide: A microscopic picture of macroscopic Si-SiO{sub 2} phase separation

We report on the first observation of the macroscopic (long-range) Si-SiO{sub 2} phase separation in Si-rich oxide SiO{sub x}(x<2) obtained by continuous-wave laser annealing of free-standing SiO{sub x} films. The effect is analyzed by a unique combination of microscopic methods (Raman, transmission, photoluminescence, and infrared spectroscopy, transmission electron microscopy, electron energy loss spectroscopy, and x-ray photoelectron spectroscopy). Three regions can be distinguished on a SiO{sub x} free-standing film after 488 nm laser annealing at intensities above {approx}10{sup 4} W cm{sup -2}: central spot, ring around the central spot, and pristine film outside the irradiated area. In the pristine SiO{sub x} material, small Si nanocrystals (Si-nc) (diameters of a few nanometer) are surrounded by SiO{sub 2} with an addition of residual suboxides, the Si-nc being produced by annealing at 1100 deg. C in a furnace. The central spot of the laser-annealed area (up to {approx}30 {mu}m wide in these experiments) is practically free of Si excess and mainly consists of amorphous SiO{sub 2}. The ring around the central spot contains large spherical Si-nc (diameters up to {approx}100 nm) embedded in amorphous SiO{sub 2} without the presence of suboxides. Laser-induced temperatures in the structurally modified regions presumably exceed the Si melting temperature. The macroscopic Si-SiO{sub 2} phase separation is connected with extensive diffusion in temperature gradient leading to the Si concentration gradient. The present work demonstrates the advantages of high spatial resolution for analysis in materials research.

36 MATERIALS SCIENCE↗

An accurate continuous calibration system for high voltage current transformer

A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

42 ENGINEERING↗

Machinability of Austempered Ductile Iron (ADI) Produced by Integrated Green Technology of Continuous Casting-Heat Treatment Processes

This study presents the novel processing technique known as continuous casting-heat treatment processes to produce Austempered Ductile Iron (ADI) which is a new class of ductile iron. ADI is characterized by improved mechanical properties but has low machinability as compared to other cast irons and steel of similar strength. The novel technique is developed by the integration of casting (in die casting) and heat treatment processes in foundry to save cost energy and time. Specimens just after casting were austenitized at 930 deg. C for 90 min and then austempered in fluidized bed at 380 deg. C for 90 and 120 min. Hence, the effect of austempering time on the morphology of retained austenite and mechanical properties of the material were examined and compared with conventionally produced ADI. Drilling tests were then carried out to evaluate the machinability of ADI in terms of cutting forces, chip micro-hardness, chip morphology and surface roughness. The mechanical properties of ADI austempered for 120 min have found to be better as compare to the ADI austempered for 90 min.

36 MATERIALS SCIENCE↗

Photo-induced mass transfer in metal nanocluster doped glasses under continuous wave laser irradiation

Mass transfer accompanying continuous wave optical recording in glasses with embedded silver nanoclusters has been studied using optical microscopy, STEM and AFM. Recording was carried out by two crossed laser beams (514 nm), which created a periodic intensity distribution on the illuminated surface of the glass-silver composites. The quality of the recorded gratings was found to be independent of the light polarization. It was determined that laser irradiation induces two mass transfer processes: diffusion coalescence of nanoclusters and redistribution of silver between illuminated and nonilluminated interference lines. The temperature profile under the illuminated surface has been calculated, as well as the kinetics of the mass redistribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic field gradient effects on Rayleigh-Taylor instability with continuous magnetic field and density profiles

In this paper, the effects of magnetic field gradient (i.e., the magnetic field transition layer effects) on the Rayleigh-Taylor instability (RTI) with continuous magnetic field and density profiles are investigated analytically. The transition layers of magnetic field and density with two different typical profiles are studied and the analytic expressions of the linear growth rate of the RTI are obtained. It is found that the magnetic field effects strongly reduce the linear growth rate of the RTI, especially when the perturbation wavelength is short. The linear growth rate of the RTI increases with the thickness of the magnetic field transition layer, especially for the case of small thickness of the magnetic field transition layer. When the magnetic field transition layer width is long enough, the linear growth rate of the RTI can be saturated. Thus when one increases the width of the magnetic field transition layer, the linear growth rate of the RTI increases only in a certain range, which depends on the magnetic field strength. The numerical results are compared with the analytic linear growth rates and they agree well with each other.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous-time photon-stimulated desorption spectroscopy studies on soft x-ray-induced reactions of CF{sub 3}Br adsorbed on Si(111)-7x7

Continuous-time core-level photon-stimulated desorption (PSD) spectroscopy was used to study the soft x-ray-induced reactions of CF{sub 3}Br molecules adsorbed on Si(111)-7x7 near the Si(2p) edge (98-110 eV). The monochromatic synchrotron radiation was employed as a soft x-ray light source in the photon-induced reactions and also as a probe for investigating the produced fluorination states of the bonding surface Si atom in the positive-ion PSD spectroscopy. Several different surface coverages were investigated. The PSD spectra from the low-CF{sub 3}Br-covered surfaces show the production of surface SiF species, while those from the high-CF{sub 3}Br-covered surfaces depict the formation of surface SiF, SiF{sub 2}, and SiF{sub 3} species. The photolysis cross section of the submonolayer CF{sub 3}Br-covered surface is determined as {approx}4.3x10{sup -18} cm{sup 2}. A comparison with the results on CF{sub 3}Cl/Si(111)-7x7 surface is discussed.

36 MATERIALS SCIENCE↗

Continuous distribution model for the investigation of complex molecular architectures near interfaces with scattering techniques

Biological membranes are composed of a thermally disordered lipid matrix and therefore require non-crystallographic scattering approaches for structural characterization with x-rays or neutrons. Here we develop a continuous distribution (CD) model to refine neutron or x-ray reflectivity data from complex architectures of organic molecules. The new model is a flexible implementation of the composition-space refinement of interfacial structures to constrain the resulting scattering length density profiles. We show this model increases the precision with which molecular components may be localized within a sample, with a minimal use of free model parameters. We validate the new model by parameterizing all-atom molecular dynamics (MD) simulations of bilayers and by evaluating the neutron reflectivity of a phospholipid bilayer physisorbed to a solid support. The determination of the structural arrangement of a sparsely-tethered bilayer lipid membrane (stBLM) comprised of a multi-component phospholipid bilayer anchored to a gold substrate by a thiolated oligo(ethylene oxide) linker is also demonstrated. From the model we extract the bilayer composition and density of tether points, information which was previously inaccessible for stBLM systems. The new modeling strategy has been implemented into the ga lowbar refl reflectivity data evaluation suite, available through the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR).

60 APPLIED LIFE SCIENCES↗

Response to 'Comment on 'Continuum modes in rotating plasmas: General equations and continuous spectra for large aspect ratio tokamaks' '[Phys. Plasmas 19, 064701 (2012)]

The equations for the continuous spectra derived in our paper [V. P. Lakhin and V. I. Ilgisonis, Phys. Plasmas 18, 092103 (2011)] can be reduced to the matrix form used by Goedbloed et al.[Phys. Plasmas 11, 28 (2004)]. It is shown that the assumptions made in our paper provide the elliptic flow regime and guarantee the existence of plasma equilibrium with nested magnetic surfaces of circular cross-section. The new results on magnetohydrodynamic instabilities of such tokamak equilibria obtained in our paper but absent in the paper by Goedbloed et al. are emphasized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The AC-Stark Effect in Nitric Oxide Induced by Rapidly Swept Continuous Wave Quantum Cascade Lasers

A large AC Stark effect has been observed when nitric oxide, at low pressure in a long optical path (100 m) Herriot cell, is subjected to infrared radiation from a rapidly swept, continuous wave infrared quantum cascade laser. As the frequency sweep rate of the laser is increased, an emission signal induced by rapid passage, occurs after the laser frequency has passed through the resonance of a molecular absorption line. At very high sweep rates a laser field-induced splitting of the absorptive part of the signal is observed, due to the AC Stark effect. This splitting is related to the Autler-Townes mixing of the hyperfine transitions, which lie within the lambda doublet components of the transition, under the Doppler broadened envelope.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗