Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Rheo–Electric Foundations and Engineering of Carbon Slurry Flow Electrodes

Flowable carbon slurry electrodes promise continuous, scalable electrochemical desalination and energy storage when their rheology (flow and stability) and electronic connectivity are jointly optimized. This report integrates six complementary thrusts that we executed under the Laboratory Directed Research and Development (LDRD) project: (i) a fast, ex situ, centrifuge-compatible method to quantify pellet (packed slurry) electronic conductivity, with a validated cell constant (“shape factor”) and quantitative structure–property insights for carbon mixtures; (ii) a controlled circulation study showing that peristaltic pumping can irreversibly alter particle size and morphology over laboratory-relevant durations; (iii) development of a miniature jet pump that preserves particle integrity while achieving entrainment ratios of 2–4 at practical flow rates; (iv) a comprehensive mapping of how a representative non-ionic surfactant (Tween 20) collapses the carbon gel network, separating network-percolation losses from intrinsic particle contact resistance; (v) in-situ visualization revealing how gravitational settling and flow-driven mixing compete to control charge transport, with dynamic bed layers preventing saturation while achieving 30-fold local concentration enhancement; and (vi) a simple, widely adoptable fabrication route to structured, gas-nitrided titanium nitride (TiN) titanium current collectors that dramatically lower interfacial losses and enable geometry-driven performance gains. Together, these results provide a coherent toolchain and design rules to accelerate formulation screening, de-risk device prototyping, and standardize characterization for carbon slurry electrodes in flow-electrode capacitive deionization (FCDI), electrochemical flow capacitor (EFC), and related systems.

25 ENERGY STORAGE↗

Solid State Lighting Program (Falcon)

Over the past two years, KLA-Tencor and partners successfully developed and deployed software and hardware tools that increase product yield for High Brightness LED (HBLED) manufacturing and reduce product development and factory ramp times. This report summarizes our development effort and details of how the results of the Solid State Light Program (Falcon) have started to help HBLED manufacturers optimize process control by enabling them to flag and correct identified killer defect conditions at any point of origin in the process manufacturing flow. This constitutes a quantum leap in yield management over current practice. Current practice consists of die dispositioning which is just rejection of bad die at end of process based upon probe tests, loosely assisted by optical in-line monitoring for gross process deficiencies. For the first time, and as a result of our Solid State Lighting Program, our LED manufacturing partners have obtained the software and hardware tools that optimize individual process steps to control killer defects at the point in the processes where they originate. Products developed during our two year program enable optimized inspection strategies for many product lines to minimize cost and maximize yield. The Solid State Lighting Program was structured in three phases: i) the development of advanced imaging modes that achieve clear separation between LED defect types, improves signal to noise and scan rates, and minimizes nuisance defects for both front end and back end inspection tools, ii) the creation of defect source analysis (DSA) software that connect the defect maps from back-end and front-end HBLED manufacturing tools to permit the automatic overlay and traceability of defects between tools and process steps, suppress nuisance defects, and identify the origin of killer defects with process step and conditions, and iii) working with partners (Philips Lumileds) on product wafers, obtain a detailed statistical correlation of automated defect and DSA map overlay to failed die identified using end product probe test results. Results from our two year effort have led to “automated end-to-end defect detection” with full defect traceability and the ability to unambiguously correlate device killer defects to optically detected features and their point of origin within the process. Success of the program can be measured by yield improvements at our partner’s facilities and new product orders.

Meeks, Steven↗

Practical Considerations for Optic Nerve Estimation in Telemedicine

The projected increase in diabetes in the United States and worldwide has created a need for broad-based, inexpensive screening for diabetic retinopathy (DR), an eye disease which can lead to vision impairment. A telemedicine network with retina cameras and automated quality control, physiological feature location, and lesion / anomaly detection is a low-cost way of achieving broad-based screening. In this work we report on the effect of quality estimation on an optic nerve (ON) detection method with a confidence metric. We report on an improvement of the fusion technique using a data set from an ophthalmologists practice then show the results of the method as a function of image quality on a set of images from an on-line telemedicine network collected in Spring 2009 and another broad-based screening program. We show that the fusion method, combined with quality estimation processing, can improve detection performance and also provide a method for utilizing a physician-in-the-loop for images that may exceed the capabilities of automated processing.

59 BASIC BIOLOGICAL SCIENCES↗

High-Performance data flows using analytical models and measurements

The combination of analytical models and measurements provide practical configurations and parameters to achieve high data transport rates: (a) buffer sizes and number of parallel streams for improved memory and file transfer rates, (b) Hamilton and Scalable TCP congestion control modules for memory transfers in place of default CUBIC, and (c) direct IO mode for Lustre file systems for wide-area transfers. Conventional parameter selection using full sweeps is impractical in many cases since it takes months. By exploiting the unimodality of throughput profiles, we developed the d-w method that significantly reduces the number of measurements needed for parameter identification. This heuristic method was effective in practice in reducing the measurements by about 90% for Lustre and XFS file transfers.

Rao, Nageswara S↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Cage effects control the mechanism of methane hydroxylation in zeolites

Catalytic conversion of methane to methanol remains an economically tantalizing but fundamentally challenging goal. Current technologies based on zeolites deactivate too rapidly for practical application. Here, we found that similar active sites hosted in different zeolite lattices can exhibit markedly different reactivity with methane, depending on the size of the zeolite pore apertures. Whereas zeolite with large pore apertures deactivates completely after a single turnover, 40% of active sites in zeolite with small pore apertures are regenerated, enabling a catalytic cycle. Detailed spectroscopic characterization of reaction intermediates and density functional theory calculations show that hindered diffusion through small pore apertures disfavors premature release of CH 3 radicals from the active site after C-H activation, thereby promoting radical recombination to form methanol rather than deactivated Fe-OCH 3 centers elsewhere in the lattice.

36 MATERIALS SCIENCE↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable oxygen standards and practices for minimum safety requirements. A summary of operational hazards, along with oxygen safety and emergency procedures, are provided.

08 HYDROGEN↗

Quantitative measurement of pebble fuel anisotropy using generalized ellipsometry

The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.

Raftery, Alicia [ORNL] (ORCID:0000000259076427)↗

Optimizing power system restoration with damaged communications

Utility procedures for power system blackstart and restoration typically assume that energization decisions can be reliably communicated across the grid. In reality, the communications and control network would likely also be affected in power outages, such as those caused by extreme weather events or cyber-attacks. This paper studies the effect of damage to the power system communications and control infrastructure on restoration operations following a blackout. We model the communications infrastructure as a graph, overlaying the power grid, and imposing the requirement that every energized element in the power grid be observable from a control center. We expand on a specialized branch-and-bound algorithm from the literature to optimize the restoration process and devise an initialization heuristic and a rounding heuristic to improve solution speed. We perform numerical experiments on synthetic systems for Illinois and Texas with outages based on a solar flare or hurricane. We compare the results of our specialized branch-and-bound algorithm to the results from (i) the initialization heuristic alone, (ii) a variation of this heuristic that we use as a baseline, and (iii) the restoration optimization for the power system without communications constraints. Here, we find that damage to the communications infrastructure significantly increases the time required to re-energize the grid. Moreover, by simultaneously optimizing communications repairs and grid energization decisions, we are able to re-energize the grid significantly faster than if communications repairs and energization decisions were made independently or with partial coordination, motivating improvements to current industry practice.

97 MATHEMATICS AND COMPUTING↗

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

Economic model predictive control of nonlinear process systems using empirical models

Economic model predictive control (EMPC) is a feedback control technique that attempts to tightly integrate economic optimization and feedback control since it is a predictive control scheme that is formulated with an objective function representing the process economics. As its name implies, EMPC requires the availability of a dynamic model to compute its control actions and such a model may be obtained either through application of first principles or through system identification techniques. In industrial practice, it may be difficult in general to obtain an accurate first‐principles model of the process. Motivated by this, in the present work, Lyapunov‐based EMPC (LEMPC) is designed with a linear empirical model that allows for closed‐loop stability guarantees in the context of nonlinear chemical processes. Specifically, when the linear model provides a sufficient degree of accuracy in the region where time varying economically optimal operation is considered, conditions for closed‐loop stability under the LEMPC scheme based on the empirical model are derived. The LEMPC scheme is applied to a chemical process example to demonstrate its closed‐loop stability and performance properties as well as significant computational advantages. © 2014 American Institute of Chemical Engineers AIChE J , 61: 816–830, 2015

Alanqar, Anas↗

Multiphase layered transition metal oxide positive electrodes for sodium ion batteries

Abstract Multiphase layered transition metal oxides (LTMOs) for sodium ion battery (SIB) positive electrodes with phase interfaces across multiple length scales are a promising avenue toward practical, high‐performance SIBs. Combinations of phases can complement each other's strengths and mitigate their weaknesses if their interfaces are carefully controlled. Intra‐ and interparticle phase interactions from nanoscale to macroscale must be carefully tuned to generate distinct effects on properties and performance. An informed design strategy must be paired with relevant synthesis techniques and complemented by spatially resolved characterization tools to manipulate different length scales and interfaces. This review examines the design, synthesis, and characterization strategies that have been demonstrated for the preparation of heterogeneous, multiphasic LTMOs with phase interfaces across varied length scales.

25 ENERGY STORAGE↗

Uptake of aqueous heavy metal ions (Co2+, Cu2+ and Zn2+) by calcium-aluminium-silicate-hydrate gels

Highlights: • C-A-S-H gels containing metal ions (Co{sup 2+}, Cu{sup 2+} or Zn{sup 2+}) were precipitated by a sol-gel technique. • Uptake mechanism and immobilization capacity of divalent metal ions by C-A-S-H are elucidated. • Up to ~55–60 mol% of Zn can be incorporated in defective tobermorite-type C-A-S-H. • Metal uptake by C-A-S-H is controlled mainly by isomorphous substitution for Ca ions. • Crystal-chemical features of C-A-S-H gels and implications for practical application are discussed. Calcium-aluminium-silicate-hydrate (C-A-S-H) gels containing heavy metal ions (Me: Co{sup 2+}, Cu{sup 2+} or Zn{sup 2+}) were precipitated at different Me/Si molar ratios to study the uptake mechanism and immobilization capacity. Aqueous solution chemistry and solid-phase characterization using XRD, FTIR, ESEM-EDX, TEM-HAADF and TG-DSC methods reveal threshold values for ion substitution of ~55–60 mol% for Zn, ~30–40 mol% for Co and ~25–30 mol% for Cu in defective tobermorite-type C-A-S-H with (Ca + Me)/(Si + Al) molar ratios from 0.86 to 1.04. At higher aqueous Me concentrations, Me (chloride) hydroxides start to co-precipitate. The uptake mechanism of Me ions by C-A-S-H is based on (i) isomorphous substitution of Me for Ca in the CaO layer, (ii) ion exchange in the interlayer, (iii) tetrahedral substitution (Zn) within the dreierketten chains and (iv) surface adsorption onto the C-A-S-H gel structure. Systematics in crystal-chemistry of Me-bearing C-A-S-H and implications for application and performance in natural and man-made settings are discussed.

36 MATERIALS SCIENCE↗

Cost-constrained adaptive simulations of transient spray combustion in a gas turbine combustor

Predictive high-fidelity simulations of turbulent spray combustion must capture the combined effects of complex chemistry, multiphase evaporating flow and spray-flame interactions to achieve physical accuracy. Finite-rate chemistry (FRC) combined with a realistic chemical mechanism is a combustion model well-suited for this purpose, but has a high computational cost due to the large number and stiffness of transported chemical species. In contrast, flamelet-based models achieve lower cost by transporting a small number of quantities of reduced stiffness, but assumptions regarding local flame topology, boundary conditions and inter-phase coupling limit their physical accuracy. Recently, the Pareto-efficient combustion (PEC) framework was developed to dynamically assign combustion models based on local cost and accuracy metrics in gas-phase reacting flows. In this work, we extend this PEC framework to spray combustion through the rigorous analysis of the multiphase coupling terms in the governing equations. The derivation shows that spray evaporation causes errors in the prediction of species mass fractions for flamelet-based models due to the sensitivity of the local thermo-chemical state to changes in composition caused by fuel vaporization across combustion regimes present in practical spray combustion devices. Sub-model assignment is formulated as a multiple-choice knapsack problem, where computational cost is directly controlled through the fraction of the domain assigned to the FRC sub-model. The extended PEC formulation is applied to the simulation of a realistic rich-quench-lean gas turbine combustor at steady-state conditions, as well as transient operation resulting in lean blow-out (LBO). Analysis of transient simulations during LBO demonstrates the extended PEC formulation’s capacity to dynamically adapt to changing conditions within the combustor. Transient combustor dynamics are shown to approach convergence with limited increases in computational cost, while retaining substantial computational cost reduction compared to monolithic FRC simulations. Through PEC simulations with increasing fractions of the domain assigned to FRC, monolithic flamelet simulations are shown to over-predict flame stability during LBO. Finally, the extended PEC formulation is thus shown to overcome deficiencies of monolithic models by controlling modeling error for multiphase combustion modeling.

33 ADVANCED PROPULSION SYSTEMS↗

Bootstrap-based confidence interval estimation for thermal security region of bulk power grid

Thermal security region (TSR) is a powerful tool for monitoring and controlling the thermal security of bulk power grid with high penetration of renewable energy. One of the major challenges of TSR in practical application is to obtain the exact analytical expression of the TSR boundary (TSRB) because TSRB is a nonlinear hypersurface described by an implicit function. For this reason, the TSRB is usually approximated by hyperplane instead of getting the exact analytical expression. Traditionally, the coefficients of the hyperplane are estimated with a set of original TSRB points using least square estimation (LSE). However, LSE is a point estimation method, which is incapable of evaluating the quality of the estimation. In addition, the accuracy and computational efficiency of the hyperplane approximation are influenced by the number of TSRB points significantly. Here, a bootstrap based confidence interval estimation is proposed to estimate not only the coefficients of TSRB approximation hyperplane, but also the standard deviations and confidence intervals of the coefficients for evaluating the quality and reliability of the approximation results. First, empirical distribution functions (EDFs) of the coefficients of TSRB approximation hyperplane are approximated from a set of original TSRB points by using residual resampling bootstrap method. Then, the EDFs of the coefficients are employed to estimate the coefficients of the approximation hyperplane. Meanwhile, the standard deviations and confidence intervals of the estimated coefficients of the hyperplanes are also calculated for evaluating the quality and reliability of the approximation. The proposed approach is tested on the China Southern Power Grid (CSG). Results of simulations validate the accuracy and efficiency of the proposed approach in approximating the TSRB.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term Outcomes in Treatment of Invasive Bladder Cancer With Concomitant Boost and Accelerated Hyperfractionated Radiation Therapy

Purpose: The aim of this study was to evaluate the long-term clinical efficacy and toxicity of concomitant boost and accelerated hyperfractionated radiation therapy (CBAHRT) in patients with invasive bladder cancer. Methods and Materials: Between October 1997 and September 2012, 334 patients with diagnoses of invasive bladder cancer were selected. These patients received CBAHRT as a bladder-conserving approach. The treatment consisted of a dose of 45 Gy/1.8 Gy to the whole pelvis with a daily concomitant boost of 1.5 Gy to the tumor. Total dose was 67.5 Gy in 5 weeks. A total of 32 patients (10.3%) had a diagnosis of stage T1, 202 (64.3%) were at stage T2, 46 (14.6%) were at stage T3a, 22 (7%) were at stage T3b, and 12 (3.8%) were at stage T4a. Results: The follow-up period was 33.1 months (range, 4.3-223.3 months). Grade 3 late intestinal toxicity was observed in 9 patients (2.9%), whereas grade 3 late urinary toxicity was observed in 8 patients (2.5%). The median overall survival (OS) was 26.3 months (95% confidence interval [CI]: 21.4-31.2). The 5-, 10, and 15-year OS rates were 32.1% (standard error [SE], ± 0.027), 17.9% (SE, ± 0.025) and 12.5% (SE, ± 0.028), respectively. The median cause-specific survival (CSS) was 42.1 months (95% CI: 28.7-55.5). The 5-, 10-, and 15-year CSS rates were 43.2% (SE, ± 0.03), 30.3% (SE, ± 0.03), and 28% (SE, ± 0.04), respectively. The median relapse-free survival (RFS) was 111.8 months (95% CI: 99.6-124). The 5-, 10-, and 15-year RFS rates were 61.9% (SE, ± 0.03), 57.6% (SE, ± 0.04), and 48.2% (SE, ± 0.07), respectively. Conclusions: The CBAHRT technique demonstrated acceptable toxicity and local control rates in patients with invasive bladder cancer, and this therapy facilitated bladder conservation. In selected patients, the CBAHRT technique is a practical alternative treatment option with acceptable 5-, 10-, and 15-year results in patients undergoing cystectomy as well as concurrent chemoradiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-design of a wave energy converter through bi-conjugate impedance matching

As with other oscillatory power conversion systems, the design of wave energy converters can be understood as an impedance matching problem. By representing the wave energy converter as a multi-port network, two separate but related impedance matching conditions can be established. Satisfying these conditions maximizes power transfer to the load. In practice, these impedance matching conditions may be used to influence the design of the system (including the hull, power take-off, controller, mooring, etc.). To this end, this paper considers some example applications of wave energy converter design with the help of the impedance matching framework.

WEC↗