A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics

A new compact stilbene crystal neutron spectrometer has been investigated and applied in the neutron emission spectroscopy on the EAST tokamak. A new components analysis method is presented to study the anisotropic light output in the stilbene crystal detector. A Geant4 code was developed to simulate the neutron responses in the spectrometer. Based on both the optimal light output function and the fitted pulse height resolution function, a reliable neutron response matrix was obtained by Geant4 simulations and validated by 2.5 MeV and 14 MeV neutron measurements at a 4.5 MV Van de Graaff accelerator. The spectrometer was used to diagnose the ion temperature in plasma discharges with lower hybrid wave injection and ion cyclotron resonance heating on the EAST tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton light yield in organic scintillators using a double time-of-flight technique

Recent progress in the development of novel organic scintillators necessitates modern characterization capabilities. As the primary means of energy deposition by neutrons in these materials is n-p elastic scattering, knowledge of the proton light yield is paramount. This work establishes a new model-independent method to continuously measure the proton light yield in organic scintillators over a broad energy range. Using a deuteron breakup neutron source at the 88-in. Cyclotron at Lawrence Berkeley National Laboratory and an array of organic scintillators, the proton light yield of EJ-301 and EJ-309, commercially available organic liquid scintillators from Eljen Technology, was measured via a double time-of-flight technique. The light yield was determined using a kinematically over-constrained system in the proton energy range of 1–20 MeV. The effect of the pulse integration length on the magnitude and shape of the proton light yield relation was also explored. In conclusion, this work enables accurate simulation of the performance of advanced neutron detectors and supports the development of next-generation neutron imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of Light Water Reactor Ex-Core Calculations with VERA

The Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) is a reactor simulation software. It offers unique capabilities by combining high-fidelity in-core radiation transport with temperature feedback by using MPACT (a deterministic neutron transport code) and COBRA-TF (a thermal-hydraulic code) with follow-on, fixed-source transport calculations using the Shift Monte Carlo code to calculate ex-core quantities of interest. In these coupled calculations, MPACT provides Shift with the fission source for follow-on ex-core calculations. These ex-core simulations can be set up to calculate detector responses, as well as the flux and fluence in ex-core regions of interest, such as the reactor pressure vessel, nozzle, and irradiated capsules. A Watts Bar Nuclear Plant Unit 1 (WBN1) ex-core model was developed, as described in this paper, and this model was used to perform coupon calculations. The results for the coupon flux calculations show close agreement with the reference values for cycle 1 produced by the two-dimensional Discrete Ordinates Transport (DORT) code and presented in a BWXT Services Inc. report. However, differences in the results (10%) seen in cycles 2 and 3 and the reasons for these differences are discussed in this paper. The VERA WBN1 model was also used to perform a vessel fluence calculation for cycle 1. Additionally, a collaboration between CASL and Duke Energy led to the first code-to-code validation of VERA for reactor ex-core applications that used a model for the Shearon Harris reactor. Results from this collaboration show excellent agreement between VERA and the Monte Carlo N-Particle Transport Code for the detector response calculations. The work performed under this collaboration is also detailed in this paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spread Spectrum Symbol Detection With Blind Interference Suppression in FBMC-SS

Recent works have demonstrated Filter Bank Multicarrier Spread Spectrum (FBMC-SS) to be a robust communication scheme in the presence of high-power interferers. Existing FBMC-SS symbol detector designs based on analysis filter banks (AFB) suggest using an optimal combining scheme to suppress the interferers, necessitating some noise/interference power estimation method. In this paper, we introduce a symbol detector with blind interference suppression by extending a recently developed packet detection method. We then provide an analysis to show that the existing AFB-based symbol detector and the one proposed in this paper are equivalent in typical usage scenarios. A fully-fledged receiver design is proposed utilizing this symbol detector, with specifics presented for estimation of the channel impulse response and carrier frequency offset (CFO). We also outline a method of iterating upon the channel and CFO estimations to improve the quality of both parameters. Moreover, a modification to allow improved performance of the symbol detector at high SNR is provided. Finally, simulated performance results are presented to corroborate these findings and demonstrate the efficiency of this receiver design.

99 GENERAL AND MISCELLANEOUS↗

Dose response of alanine detectors irradiated with carbon ion beams

Purpose: The dose response of the alanine detector shows a dependence on particle energy and type when irradiated with ion beams. The purpose of this study is to investigate the response behavior of the alanine detector in clinical carbon ion beams and compare the results to model predictions. Methods: Alanine detectors have been irradiated with carbon ions with an energy range of 89-400 MeV/u. The relative effectiveness of alanine has been measured in this regime. Pristine and spread out Bragg peak depth-dose curves have been measured with alanine dosimeters. The track structure based alanine response model developed by Hansen and Olsen has been implemented in the Monte Carlo code FLUKA and calculations were compared to experimental results. Results: Calculations of the relative effectiveness deviate less than 5% from the measured values for monoenergetic beams. Measured depth-dose curves deviate from predictions in the peak region, most pronounced at the distal edge of the peak. Conclusions: The used model and its implementation show a good overall agreement for quasimonoenergetic measurements. Deviations in depth-dose measurements are mainly attributed to uncertainties of the detector geometry implemented in the Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results

Purpose: The purpose of this work is to present a performance study of the digital beam attenuator (DBA) for implementing fluence field modulated CT (FFMCT) using a simulation framework developed to model the incorporation of the DBA into an existing CT system. Additionally, initial results will be presented using a prototype DBA and the realization of the prototype will be described. To our knowledge, this study represents the first experimental use of a device capable of modulating x-ray fluence as a function of fan angle using a CT geometry. Methods: To realize FFMCT, the authors propose to use a wedge design in which one wedge is held stationary and another wedge is moved over the stationary wedge. Due to the wedge shape, the composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. This design allows for the wedges to modulate the photon fluence incident onto a patient. Using a simulation environment, the effect of changing the number of wedges has on dose, scatter, detector dynamic range, and noise uniformity is explored. Experimental results are presented using a prototype DBA having ten Fe wedges and a c-arm CT system geometry. The experimental DBA results are compared to non-DBA scans using scatter and detector dynamic range as metrics. Both flat field and bowtie filtered CT acquisitions were simulated for comparison with the DBA. Results: Numerical results suggest that substantial gains in noise uniformity and scatter-to-primary ratio (SPR) can be obtained using only seven wedges. After seven wedges, the decrease in noise ununiformity and SPR falls off at a lower rate. Simulations comparing CT acquisitions between flat field, bowtie enabled, and DBA CT acquisitions suggest DBA-FFMCT can reduce dose relative to flat field CT by Almost-Equal-To 3 times. A bowtie filter under the same imaging conditions was shown to only allow a dose reduction of 1.65 times. Experimentally, a 10 wedge DBA prototype result showed a SPR reduction of Almost-Equal-To 4 times relative to flat field CT. The dynamic range for the DBA prototype was 3.7 compared to 84.2 for the flat field scan. Conclusions: Based on the results presented in this paper and the companion paper [T. Szczykutowicz and C. Mistretta, 'Design of a digital beam attenuation system for computed tomography. Part I. System design and simulation framework,' Med. Phys. 40, 021905 (2013)], FFMCT implemented via the DBA device seems feasible and should result in both a dose reduction and an improvement in image quality as judged by noise uniformity and scatter reduction. In addition, the dynamic range reduction achievable using the DBA may allow photon counting imaging to become a clinical reality. This study may allow for yet another step to be taken in the field of patient specific dose modulation.

60 APPLIED LIFE SCIENCES↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methodology of the Extraction of Multi-Differential Cross Sections of Charged-Current $\nu_\mu$-Argon Interactions in MicroBooNE Using Wire-Cell $\nu_\mu$CC Selection

Neutrino physics experiments rely on accurate nuclear-interaction models that are in part guided by experimental observations. Multi-differential cross section measurements are particularly valuable for exploring the underlying physics described in these models, making them a significant step forward in the field. This note presents methodology in preparation to unfold neutrino flux-averaged double and triple-differential cross sections of the inclusive muon neutrino charged-current interaction on Argon. This work builds upon the existing framework and methodology presented in recent energy dependent cross section measurements at MicroBooNE using the Wire-Cell tomographic event reconstruction. The signal definition, choice of binning, and handling of estimated detector uncertainties are discussed, and the MicroBooNE simulation model is validated over the multi-dimensional phase space of muon momentum, muon polar angle, and visible hadronic energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing experiment searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a sub-experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of all converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within 50 $\mu$m in three dimensions.

Rao, Shardul↗

Next Generation Sensor Development (CRADA Final Report)

B. Project Scope This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS), as manager and operator of Lawrence Livermore National Laboratory (LLNL) and The Federal Reserve Bank of San Francisco ("FRBSF" or "Participant"), to research and develop advanced processing techniques to measure the fitness and authenticity of U.S. currency. The FRBSF previously partnered with LLNL to evaluate end-of-life predictions, review sensor requirements, develop communications protocols, and perform thermal analysis. These Strategic Partnership Projects (SPP) included SPP No. L20960 - Federal Reserve Currency Technology Office Studies, SPP No. L15900 - Development of a Common Detector Interface (CDI 2.0) Specification and Hardware Simulators, and SPP No. L15610 - Limited Design Review of a Second-Generation E-Material Authentication Sensor (EMAS2).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Preliminary Comparison of Neutron Detector Sensitivities [Poster]

Nuclear data (ND) is vital to predictive simulations such as those completed with MCNP®. ND sensitivities are used to optimize the design of benchmark experiments. Diverse benchmarks (including neutron noise) are required to further our understanding of ND. Measured and simulated data of a 4.5-kg Pu sphere was used to calculate neutron noise parameters and associated ND Sensitivities

Nuclear Criticality Safety Program (NCSP)↗

Refining a Novel Process Monitoring Method to Safeguard Continuously Cycling Designs Using Isotopic Ratios

In advanced reactor (AR) designs, a common feature is continuous chemical processing and circulation of the nuclear material. This work bridges a significant measurement gap in safeguarding reactors with circulating fuel or continuous refueling by leveraging and building on the isotope ratio method first developed by our team under an FY21 Advanced Reactors International Safeguards Engagement (ARISE) project (Uribe et al. 2021). In circulating fuel designs, the radioisotope inventory changes from traditional effects (e.g., radioactive decay, fission) but also includes material transport due to pressure and temperature gradients. Such designs may also require regular or continuous additions or removals during operation, which significantly increases the rate of inventory change compared to traditional pressurized water reactor (PWR)s. Thus, directly tracking the nuclear inventory is ineffective since the isotopes are continuously added and removed. The isotope ratio method instead focuses on detecting changes to the input and output flows of radioisotopes. Previous work showed that for well-chosen pairs of isotopes, the isotopic ratio provides a sensitive and lasting indicator of deviation from normal conditions (e.g., startup, shutdown, diversion). The isotope ratio method is a process monitoring method with potential for application in for forward-looking approaches to International Atomic Energy Agency (IAEA) safeguards. The original process monitoring method was developed for a specific case—the decay tank of a thorium-fueled molten salt breeder reactor. In this expanded work, we explored other types of reactors and processes with nonstationary (e.g., flowing) nuclear material, which are difficult to safeguard with traditional methods because of the transient nature of the systems. The goal of the present work is to generalize the isotope ratio method for use in processes with continuously flowing nuclear material. All continuous processes have an average time for isotopes to be replaced in the system. The isotope ratio method works by choosing radioisotopes with half-lives both above and below the processing time. The present work seeks to explore which isotopes are suitable for the method by simulating the nuclear inventory, radioisotope emissions, and detector responses for several classes of advanced reactors. While the method can in principle be applied to other processes (e.g., enrichment or reprocessing facilities), the present work limits scope to ARs with continuously flowing fuel. Section 2 details the mathematics supporting the isotope ratio method, and Section 3 introduces the representative ARs selected for this work. Section 4 discusses how each reactor was analyzed, and Section 5 showcases the results for each representative reactor. Finally, Section 6 provides concluding remarks and suggests pathways for further analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Testing methods and techniques: Testing electrical and electronic devices: A compilation

The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.

Source record↗

Gamma-hadron families and scaling violation

For three different interaction models we have simulated gamma-hadron families, including the detector (Pamir emulsion chamber) response. Rates of gamma families, hadrons, and hadron-gamma ratios were compared with experiments.

Gaisser, T. K.↗

Lidar multiple scattering: Dependence on atmospheric parameters

Backscatter lidars are very useful tools in gaining information about the atmosphere. Inversion of backscatter signals can be used to retrieve the spatial distribution of clouds and aerosols, e.g., vertical extensions of clouds and aerosol layers, detection of 'subvisible' cirrus, etc., very accurately compared to passive radiometers. To retrieve extinction coefficient profiles, in general, the so-called lidar equation is solved. This equation describes a laser pulse which propagates through an atmosphere with transmission exp(- integral of sigma(z')dz'), which is scattered singly under 180 degrees towards a receiver, and which is attenuated on its way back again by exp(- integral of sigma(z')dz'). For inversion, further information on optical properties of the scatterers are required (extinction to backscatter ratio). However, it is evident that, at least for optically thick clouds and/or large receiver's field-of-views, this approach may be erroneous because of multiply scattered photons. Several studies were performed to simulate multiple scattering in case of collimated beams or pulses including Monte Carlo, transport, and diffusion theory. Unfortunately, most of the approaches require an enormous amount of computer time. Thus, it is meaningful to elaborate approximate methods, and one such method is discussed. Our method is based on Bissonnett (1988). We have improved the numerical simulation of limited field-of-view detectors, and compared the results to Monte Carlo calculations and an exact model of Altmann (1989).

Wiegner, Matthias↗

Coronagraphic Methods for the Detection of Terrestrial Planets

I will contribute (i.e. join in writing the TPF-C Report) for the following workshop topics: 1) Science Topics (target list): I describe a new target list for the TPF-C based on General TPF target list maintained at the US Naval Observatory; 2) Science Topics (spectroscopy): I describe the need for optical, imaging, pulse-counting detectors for spectroscopy of terrestrial planets; 3) Simulation and Modeling Techniques: I describe work at Goddard Space Flight Center to simulate wide-band imagery and spectroscopic imagery that will be obtained by TPF-C.

Heap, Sally↗