Theory of distributed parameter systems
Lumped and distributed parameter systems, discussing transfer matrix elements, connecting lines, etc
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lumped and distributed parameter systems, discussing transfer matrix elements, connecting lines, etc
In controlling distributed parameter systems it is often desirable to obtain low-order, finite-dimensional controllers in order to minimize real-time computational requirements. Standard approaches to this problem employ model/controller reduction techniques in conjunction with LQG theory. In this paper we consider the finite-dimensional approximation of the infinite-dimensional Bernstein/Hyland optimal projection theory. This approach yields fixed-finite-order controllers which are optimal with respect to high-order, approximating, finite-dimensional plant models. The technique is illustrated by computing a sequence of first-order controllers for one-dimensional, single-input/single-output, parabolic (heat/diffusion) and hereditary systems using spline-based, Ritz-Galerkin, finite element approximation. Numerical studies indicate convergence of the feedback gains with less than 2 percent performance degradation over full-order LQG controllers for the parabolic system and 10 percent degradation for the hereditary system.
The present paper details the design of the counter rotating fans for a Turboelectric Distributed Propulsion (TeDP) system. Sixteen propulsors installed in mail-slot-shape nacelles are embedded on an aerodynamically optimized hybrid wing-body configuration. The hybrid-wing/body (HWB) configuration which was previously designed to satisfy the conditions of trim, longitudinally static stability and specific cargo space is employed as the baseline configuration in pursuing an optimal distributed propulsion system. A set of distributed propulsors is conceptually designed and the collective performance is evaluated against the target thrust mandated by the mission requirements. The concept of the distributed propulsion allows the fan pressure ratio to be around 1.27~1.32 for the target thrust. In addition, further splitting of the fan pressure ratio by using the counter-rotating fans for each slot realizes the target pressure ratio with low tip speed. In the distributed propulsion system, the nature of the flow conditions and/or the thickness of the ingested boundary layer may differ and result in different propulsive reaction of each individual propulsor. The optimization is, thus, approached from both the propulsion system and individual propulsor perspectives. An optimal distribution of the thrust and power output is determined by how the system utilizes each passage's propulsive characteristics and its interaction with the airframe. These system level analysis and optimization are conducted using an actuator disk model to account for the propulsion-airframe integration numerically. With respect to the propulsor level, aerodynamic shape optimizations of the fan blades are performed in a sequential multi-objective optimization process for various design objectives, such as mass flow rate condition, fan pressure ratio, efficiency and the exit flow angle of the fan stage by using a genetic algorithm, NSGA-II. The radial chord distribution, and meanline distribution of the rotors are designed on the circumferentially averaged axi-symmetric inlet profiles and tested on the six inlet profiles from six divided sectors to reckon flow distortion. The performances of the counter rotating fans are, thus, evaluated accordingly for obtaining distortion tolerant fan. The performance of the distributed propulsion system is evaluated by two CFD tools, i.e., a multi-stage turbo-machinery CFD code and one propulsion-airframe integration flow solver coupled with a body-force model. The optimized boundary layer ingestion propulsion system of 16 distributed slots not only reaches the system target thrust, but also delivers a close to 20% fuel saving benefit against its counterpart 12 distributed clean inlet propulsion system.
With increasing integration of distributed energy resources (DERs), distribution systems (DS) with DERs are expected to provide proactive grid services. The result is that power references, or known as dispatch signals, required for DS can become faster changing than in legacy power system. Consensus-based integral controls have been proposed for the purpose of coordinating power generations of DERs in DS to match the power references. These existing controls assume the integral control signal to be sufficiently slow or constant, and ignore the potential dynamics of the integral controller when tracking more varying power references. Therefore, in this paper we present an improvement for such controls by deriving the stability condition utilizing generalized Nyquist criterion. The stability condition is quantified by a set of integral gains that guarantee stability in closed-loop system without assuming a constant integral signal. A rule-of-thumb criterion is also derived to instruct the design of the consensus topology that can provide faster convergence rate for the closed-loop system. Here, the stability and convergence improvements developed in this paper are demonstrated and verified through numerical examples.
Severe weather, cyber-attacks, geomagnetic disturbances, and other hazards and threats have caused or have the potential to cause substantial levels of damage to electricity infrastructure and the global economy. Growth in distributed energy resources (DERs) and increasing attention to the resilience of the electric grid - its ability to "anticipate, absorb, adapt to, and/or rapidly recover" from disruptions, according to the Federal Energy Regulatory Commission (FERC, 2018) - have created an opportunity for energy stakeholders to develop and deploy "resilient DERs," resources in the distribution grid that improve the ability of a customer, critical facility, and/or the distribution system in general to anticipate, absorb, adapt to, and/or rapidly recover from disruptions. This paper explores how existing state regulations intersect with resilience and highlights opportunities where state regulators can employ DERs to advance resilience.
Protection in distribution systems is vital for maintaining reliability and ensuring proper power quality is provided to the end-use customer. As more switching devices are deployed on distribution systems, traditional protection schemes are giving way to more advanced, and sometimes centrally coordinated, protection schemes that rely on communications infrastructure. With these communications-dependent systems, the behaviors of the protection with and without the communications infrastructure must be examined. This work has evaluated the impacts of loss of communication in centrally coordinated protection schemes. Two test cases were examined: a sequence of similar faults on a feeder before and after a topology reconfiguration, and a feeder with a photovoltaic (PV) fault current contribution. Both simulations are run in the GridLAB-D™ simulation environment. A simple connectivity model is used to represent communication status. The results reveal that a failure of the communication system can cause significantly different protection behavior. This analysis can be used as a basis for utility engineers to make an informed decision on the impacts of communication losses on their system, as well as evaluating ways to mitigate its impact on the resiliency of the system.
In recent years, distributed energy systems (DES) have attracted worldwide attention. Distributed generation unit (DG) in DES usually works under part load during night, which results in low efficiency and the waste heat of DG cannot be fully utilized. This study proposes a novel absorption thermal energy storage system together with electric energy storage for distributed energy systems. The proposed absorption thermal energy storage system which is a combination of absorption chiller and liquid storage tanks, has a higher energy storage density. During off-peak hours, the extra electricity of DG can be used by electric chillers (EC) and the extra waste heat of DG is stored by the proposed absorption thermal energy storage system. The stored thermal energy is released in peak hours to meet the cooling loads of buildings. A case study of DES in a campus under cooling-dominated climate is conducted to evaluate the performance of the proposed system. The results in a typical summer day indicate that the DG utilization rate increases from 80% to 92.9%, meanwhile the required capacities of electric chillers can be obviously reduced. The operating cost of DES also reduces by 12.9% compared with the DES without energy storage. Through appropriate operation strategy, off-the-grid operation for DES can be achieved without energy waste by applying the proposed energy storage method.
A simulation model of the NASA Huntsville Operational Support Center (HOSC) was developed. This simulation model emulates the HYPERchannel Local Area Network (LAN) that ties together the various computers of HOSC. The HOSC system is a large installation of mainframe computers such as the Perkin Elmer 3200 series and the Dec VAX series. A series of six simulation exercises of the HOSC model is described using data sets provided by NASA. The analytical analysis of the ETHERNET LAN and the video terminals (VTs) distribution system are presented. An interface analysis of the smart terminal network model which allows the data flow requirements due to VTs on the ETHERNET LAN to be estimated, is presented.
A methodology for building interfaces of resident database management systems to a heterogeneous distributed database management system under development at NASA, the DAVID system, was developed. The feasibility of that methodology was demonstrated by construction of the software necessary to perform the interface task. The interface terminology developed in the course of this research is presented. The work performed and the results are summarized.
A Turboelectric Distributed Propulsion (TeDP) system differs from other propulsion systems by the use of electrical power to transmit power from the turbine to the fan. Electrical power can be efficiently transmitted over longer distances and with complex topologies. Also the use of power inverters allows the generator and motors speeds to be independent of one another. This decoupling allows the aircraft designer to place the core engines and the fans in locations most advantageous for each. The result can be very different installation environments for the different devices. Thus the installation effects on this system can be quite different than conventional turbofans where the fan and core both see the same installed environments. This paper examines a propulsion system consisting of two superconducting generators, each driven by a turboshaft engine located so that their inlets ingest freestream air, superconducting electrical transmission lines, and an array of superconducting motor driven fan positioned across the upper/rear fuselage area of a hybrid wing body aircraft in a continuous nacelle that ingests all of the upper fuselage boundary layer. The effect of ingesting the boundary layer on the design of the system with a range of design pressure ratios is examined. Also the impact of ingesting the boundary layer on off-design performance is examined. The results show that when examining different design fan pressure ratios it is important to recalculate of the boundary layer mass-average Pt and MN up the height for each inlet height during convergence of the design point for each fan design pressure ratio examined. Correct estimation of off-design performance is dependent on the height of the column of air measured from the aircraft surface immediately prior to any external diffusion that will flow through the fan propulsors. The mass-averaged Pt and MN calculated for this column of air determine the Pt and MN seen by the propulsor inlet. Since the height of this column will change as the amount of air passing through the fans change as the propulsion system is throttled, and since the mass-average Pt and MN varies by height, this capture height must be recalculated as the airflow through the propulsor is varied as the off-design performance point is converged.
The efficiency of distributed energy systems can be significantly increased through waste heat recovery from industry or power generation. The technologies used for this process are typically dependent on the quality and temperature grades of waste heat. To maximize the efficiency of cascade heat utilization, it is important to optimize the choice of waste heat recovery technologies and their operation. Here, a detailed mixed integer linear programming optimization model is proposed for waste heat recovery in a district-scale microgrid. The model can distinguish waste heat quality for planning and operation optimization of distributed energy systems. Heat utilization technologies are formulated in this developed model and categorized in different temperature grades. The developed model is validated using four typical cases under different settings of system operation and business models. It is found that the optimization model, by distinguishing waste heat temperature, can increase energy cost savings by around 5%, compared to models that do not consider waste heat temperature grades. Additionally, the results indicate that the developed model can provide more realistic configuration and technologies dispatch.
Embedded distributed systems have become an integral part of safety-critical computing applications, necessitating system designs that incorporate fault tolerant clock synchronization in order to achieve ultra-reliable assurance levels. Many efficient clock synchronization protocols do not, however, address Byzantine failures, and most protocols that do tolerate Byzantine failures do not self-stabilize. Of the Byzantine self-stabilizing clock synchronization algorithms that exist in the literature, they are based on either unjustifiably strong assumptions about initial synchrony of the nodes or on the existence of a common pulse at the nodes. The Byzantine self-stabilizing clock synchronization protocol presented here does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The proposed protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period. Proofs of the correctness of the protocol as well as the results of formal verification efforts are reported.
Embedded distributed systems have become an integral part of safety-critical computing applications, necessitating system designs that incorporate fault tolerant clock synchronization in order to achieve ultra-reliable assurance levels. Many efficient clock synchronization protocols do not, however, address Byzantine failures, and most protocols that do tolerate Byzantine failures do not self-stabilize. Of the Byzantine self-stabilizing clock synchronization algorithms that exist in the literature, they are based on either unjustifiably strong assumptions about initial synchrony of the nodes or on the existence of a common pulse at the nodes. The Byzantine self-stabilizing clock synchronization protocol presented here does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The proposed protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period. Proofs of the correctness of the protocol as well as the results of formal verification efforts are reported.
Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.
Specifically, a class of distributed parameter systems is defined using Hilbert space methods based on a partial differential equation model of a structure. In this space a simple, easy to check definition of underdamping is constructed based on the well known single degree of freedom concept of critical damping. It is then shown that if a given distributed parameter system satisfies this definition, each mode of the modal expansion of the solution is in fact an underdamped function of time. It is noted that a distributed parameter system which is underdamped is also uniformly exponentially stable. By appealing to the work of Gibson, a finite dimensional model of the system will yield satisfactory control laws. Furthermore, it is shown that the assumption of the underdamping also allows straightforward computation of rough bounds on the magnitude of the unmodeled or residual modes for a modal truncation scheme. Hence, underdamped systems are precisely that class of distributed parameter systems which are not likely to have spillover problems and which will yield convergence of finite dimensional control laws to control laws which are optimal for the full distributed parameter model of the system.
A significant increase in photovoltaic (PV) system installations is expected to come on line in the near future and as the penetration level of PV increases, the effect of PV may no longer be considered minimal. One of the most important attributions of additional PV is what effect this may have on protection systems. Protection engineers design protection systems to safely eliminate faults from the electric power system. One of the new technologies recently introduced into the electric power system are distributed energy resources (DER). Currently, inverter-based DER contributes very little to the power balance on all but a few utility distribution systems. As DER become prevalent in the distribution system, equipment rating capability and coordination of protection systems merit a closer investigation. A collaborative research effort between the National Renewable Energy Laboratory (NREL) and Southern California Edison (SCE) involved laboratory short-circuit testing single-phase (240 VAC) residential type (between 1.5 and 7kW) inverters. This paper will reveal test results obtained from these short-circuit tests.
This paper presents the results obtained in a continuing investigation of real-time distributed processing systems which is being conducted at the Jet Propulsion Laboratory. A distributed processor architecture has been developed for control and data handling on a planetary spacecraft. This system, designated the Unified Data System, has been implemented in a feasibility breadboard. The following aspects of the Unified Data System are described: (1) standardized building block elements and their configuration into microprocessor modules, (2) a highly redundant bus structure which connects the various modules and facilitates intercommunications with minimal software support, (3) the structure of software within the individual modules and its coordination between modules, and (4) the mechanisms by which fault-tolerance can be implemented within the network. Through the attributes of multilevel standardization, simplicity, and flexibility, this system is expected to result in significant cost savings to future spacecraft missions.