Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Automated Software Reliability Tester for Digital I and C

Existing nuclear facilities are in the process of upgrading analog systems to new, software- based digital components; however, the qualification of these new systems has been a significant hurdle for their implementation in the United States. This paper describes the development of a Software Reliability Tester (SRT) that will provide a means to quantify the reliability and fault tolerance of digital instrumentation and control (I and C) systems used in nuclear facilities. The SRT is comprised of hardware and software that exercise digital equipment inputs and compare the outputs to expected values to quantify system reliability. Incorporation of fault injection techniques enables the SRT to evaluate the robustness of digital I and C in the presence of abnormal conditions. The integration of both quantitative reliability and fault tolerance measures will provide the nuclear industry with an automated and systematic approach to digital I and C qualification. This will enable safer, more reliable, and more cost effective implementations of a broad spectrum of digital I and C equipment in existing and next generation nuclear facilities. This paper includes a description of the design of the SRT, including software modules and the hardware interface. In addition, an example of using the SRT to automate functional testing of a digital timer relay is presented. The SRT described in this paper provides a means to conduct efficient and robust testing for a variety of digital devices. Future plans for the SRT include integrating fault injection testing so that devices can be evaluated in the presence of off-normal conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LINAC Longitudinal Simulation and Measurement of Output Energy

The Linac at Fermilab, one of the oldest accelerators on-site, plays a crucial role in delivering 400 MeV proton beams to other accelerating facilities. The beam traveling through Linac needs to be carefully monitored for better accelerator operation. One of the key factors of efficient Linac operation is its longitudinal stability. The stability can minimize Linac loss and maximize beam current. For this purpose, I examined the beam's longitudinal profile, which is crucial for proper beam transfer between its two sections. After careful monitoring of the beam through Linac, we need to ensure that it leaves with desired parameters. The beam coming out from the Linac is subsequently injected into the Booster, a synchrotron that relies on dipole magnets to bend the beam at injection. If the output energy of the beam deviates from the expected value, the beam will bend at an incorrect radius, leading to potential beam loss. Therefore, precise regulation of the output energy is critical for the efficient operation of the accelerator. To address this, I have conducted a thorough examination of the Linac longitudinal simulations and data from Beam Position Monitors (BPMs). My objective is to measure and stabilize the output energy and verify its correspondence with the predicted simulation results. All these analyses are important for efficient operation of the accelerator.

Safaryan, Milena↗

Redshifting the Cosmological Constant in Unimodular Gravity via Nonlinear Quantum Mechanics

The cosmological constant problem represents a profound conflict between quantum field theory and general relativity. Unimodular gravity offers a compelling starting point by de-gravitating the vacuum energy of the Standard Model, but this framework traditionally trades the problem of vacuum energy for a fine-tuning of initial conditions, which manifest as a ``shadow" cosmological constant. In this paper, we resolve this initial conditions problem by proposing a novel modification to gravity based on nonlinear quantum mechanics. We introduce specific state-dependent terms to the Hamiltonian, constructed from expectation values of the metric such as the average Ricci scalar. These terms alter the dynamical equations of gravity such that the shadow energy density associated with unconstrained initial conditions redshifts away with cosmic expansion, rendering it negligible at late times. The resulting cosmology is naturally dominated by matter and radiation without fine-tuning. We demonstrate that this significant infrared modification of gravity is consistent with local and cosmological tests of gravity. We comment on the possibility of testing this solution in cosmological measurements of Newton's constant.

Kaplan, David E. [Johns Hopkins U.; Tokyo U., IPMU↗

A Solution to the Hierarchy Problem with Non-Linear Quantum Mechanics

We argue that the hierarchy problem of the standard model of particle physics can be solved by adding a state-dependent term to the Higgs sector. We present an example of a scalar field with a Higgs-like potential with an additional term proportional to the expectation value of the squared Higgs field operator. We show that the mass can be parametrically lighter than the theory's energy-momentum cutoff without fine tuning. We find the Higgs mass can be technically natural, even with a Planck-scale cutoff. The simplest version of the theory may not be distinguishable from the standard model at colliders, but other versions might. In addition, some aspects of cosmological evolution can be different in this model, in some cases radically.

Kaplan, David E. [Johns Hopkins U.; Tokyo U., IPMU↗

Alcock-Paczynski Blinding Scheme for the Ly-$α$ Forest Analysis

We present and validate a blinding method for the Lyman-$α$ (Ly$α$) forest analysis based on a modification of the Alcock-Paczynski test. In order to hide the background expansion history, the method employs a geometrical shift of each quasar (QSO) forest in wavelength space, once the quasar continuum has been fitted and the fluctuation field is extracted. The redshift positions for the QSO sample are also changed in a consistent manner. We show that the method remains effective when applied to real data, where contamination from metals and Lyman-$β$ is intrinsically mixed with the Lyman-$α$ forest. This limitation is primarily visible in the 1D correlation function, where other blinding strategies can mitigate the effect. To assess its effectiveness, the prescription is tested against a series of datasets of increasing complexity: from idealized low-noise mocks, to realistic DESI year one synthetic datasets, and finally to data from DESI first data release (DR1), using both the auto (Ly$α\times$Ly$α$) and cross (Ly$α\times$ QSO) correlations. We find that the method robustly shifts the BAO peak position from the 3D correlation functions to the expected value for cosmology changes of around 5% in the matter content, without altering the shape of the posteriors in the model parameters. In conclusion, this catalog-level blinding strategy is a viable method for cosmological inference with the Lyman-$α$ forest, particularly if a cross-analysis with other tracers using the same blinding strategy is pursued.

Perez-Sanchez, G. [Guanajuato U.] (ORCID:000900096↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Element-specific study of the temperature dependent magnetization of Co-Mn-Sb thin films

Magnetron sputtered thin Co-Mn-Sb films were investigated with respect to their element-specific magnetic properties. Stoichiometric Co{sub 1}Mn{sub 1}Sb{sub 1} crystallized in the C1{sub b} structure has been predicted to be half-metallic and is therefore of interest for spintronics applications. It should show a characteristic antiferromagnetic coupling of the Mn and Co magnetic moments and a transition temperature T{sub C} of about 480K. Although the observed transition temperature of our 20nm thick Co{sub 32.4}Mn{sub 33.7}Sb{sub 33.8}, Co{sub 37.7}Mn{sub 34.1}Sb{sub 28.2} and Co{sub 43.2}Mn{sub 32.6}Sb{sub 24.2} films is in quite good agreement with the expected value, we found a ferromagnetic coupling of the Mn and Co magnetic moments which indicates that the films do not crystallize in the C1{sub b} structure and are probably not fully spin-polarized. The ratio of the Co and Mn moments does not change up to the transition temperature and the temperature dependence of the magnetic moments can be well described by the mean field theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fermi Surface Evolution Across Multiple Charge Density Wave Transitions in ErTe3

The Fermi surface (FS) of ErTe{sub 3} is investigated using angle-resolved photoemission spectroscopy (ARPES). Low temperature measurements reveal two incommensurate charge density wave (CDW) gaps created by perpendicular FS nesting vectors. A large {Delta}{sub 1} = 175 meV gap arising from a CDW with c* - q{sub CDW1} {approx} 0.70(0)c* is in good agreement with the expected value. A second, smaller {Delta}{sub 2} = 50 meV gap is due to a second CDW with a* - q{sub CDW2} {approx} 0.68(5)a*. The temperature dependence of the FS, the two gaps and possible interaction between the CDWs are examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some Considerations on Stochastic Neutron Populations

The neutron population in a multiplying body containing a weak random source may depart considerably from its average or expected value. The resulting behavior of the system is then unpredictable, and a fully stochastic description of the neutron population becomes necessary. Stochastic considerations are especially important when dealing with pulsed reactors or in the case of criticality excursions in the presence of a weak source. Using the theory of discrete-state continuous-time Markov processes, and subject to some physical approximations, Bell obtained approximate solutions for the neutron number probability distributions (pdf), with and without an intrinsic random neutron source, that were valid at late times and/ large neutron populations. In recent work, we obtained exact solutions for Bell's model problem, and in this paper we use these exact probability distributions to: (I) assess the accuracy of Bell's asymptotic solutions and show how the latter follow from the exact solutions, (2) rigorously examine the probability of obtaining a divergent chain reaction, and (3) demonstrate the existence of an abrupt transition from a stochastic to a deterministic phase with increasing source strength.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements on Subscale Y-Ba-Cu-O Racetrack Coils at 77 K and Self-Field

YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) tapes carry significant amount of current at fields beyond the limit of Nb-based conductors. This makes the YBCO tapes a possible conductor candidate for insert magnets to increase the bore field of Nb{sub 3}Sn high-field dipoles. As an initial step of the YBCO insert technology development, two subscale racetrack coils were wound using Kapton-insulated commercial YBCO tapes. Both coils had two layers; one had 3 turns in each layer and the other 10 turns. The coils were supported by G10 side rails and waxed strips and not impregnated. The critical current of the coils was measured at 77 K and self-field. A 2D model considering the magnetic-field dependence of the critical current was used to estimate the expected critical current. The measured results show that both coils reached 80%-95% of the expected values, indicating the feasibility of the design concept and fabrication process.

43 PARTICLE ACCELERATORS↗

Spin and orbital Ti magnetism at LaMnO3/SrTiO3 interfaces

In systems with strong electron-lattice coupling, such as manganites, orbital degeneracy is lifted, what causes a null expectation value of the orbital moment. Magnetic structure is thus determined by spin-spin superexchange. In titanates, however, with much smaller Jahn-Teller distortions, orbital degeneracy might allow non-zero values of the orbital magnetic moment. Accordingly, novel forms of ferromagnetic superexchange interaction unique to t2g electrons systems have been theoretically predicted, although their experimental observation has remained elusive. Here we report a new kind of Ti3+ ferromagnetism at LaMnO3/SrTiO3 epitaxial interfaces. It results from charge transfer to the empty conduction band of the titanate and has spin and orbital contributions evidencing the role played by orbital degeneracy. The possibility of tuning magnetic alignment (ferromagnetic or antiferromagnetic) of Ti and Mn moments by structural parameters is demonstrated. This result will provide important clues for the understanding of the effects of orbital degeneracy in superexchange coupling.

36 MATERIALS SCIENCE↗

SU-E-J-207: Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)

Purpose: Four-dimensional-computed-tomography(4D-CT) imaging for target-volume delineation and cone-beam-tomography(CBCT) for treatment localization are widely utilized in lung-SABR.Aim of this study was to perform a quantitative-assessment and inter-comparison of Internal-targetvolumes( ITV) drawn on various phases of breathing-cycle 4D-CT-scans, Maximum-intensity-projection(MIP), average-intensity-projection(AIP)and static CT-scans of lung-motion-phantom to simulate lung-SABR patient geometry. We also analyzed and compared the ITVs drawn on freebreathing- CBCT. Materials and Methods: 4D-CT-scans were acquired on Philips big-bore 16slice CT and Bellows-respiratory monitoring-system using retrospective phase-binning method. Each respiratory cycle divided into 10-phases. Quasar-Phantom with lung-inserts and 3cm-diameter nylonball to simulate tumor and was placed on respiratory-motion-platform for 4D-CT and CBCT-acquisition. Amplitudes of motions: 0.5,1.0,2.0,3.0cm in superior-inferior direction with breathing-cycle time of 6,5,4,6sec, respectively used.4D-CTs with 10-phases(0%to90%)for each excursion-set and 3D-CT for static-phantom exported to iPlan treatment-planningsystem( TPS).Tumor-volumes delineated in all phases of 4D-CT, MIP,AIP,CBCT scans using fixed-HU-threshold(−500to1000)values automatically.For each 4D-dataset ITV obtained by unifying the tumorcontours on all phases.CBCT-ITV-volumes were drawn in Eclipse-TPS. Results: Mean volume of tumor contours for all phases compared with static 3D-CT were 0.62±0.08%, 1.67±0.26%, 4.77±0.54% and 9.27±1.23% for 0.5cm,1cm,2cm,3cm excursions respectively. Differences of mean Union-ITV with MIP-ITV were close(≤2.4%).Mean Union-ITV from expected-theoretical values differed from −4.9% to 3.8%.Union-ITV and MIP-ITV were closer within 2.3%. AIP-ITVs were underestimated from 14 to 32% compared to union-ITV for all motion datasets. Differences of −5.9% to −44% and −5% to 6.7% for CBCT-ITV from MIP-ITV and AIP-ITV respectively.Motion excursions and centroid positions were within 2mm for 4D-CT and CBCT-ITVs to that of expected values. Conclusion: 4D-CT MIP-ITV and Union-ITV showed very good agreement that validates that ITV can be fast contoured on MIP.Contouring ITV in AIP must be avoided as it significantly underestimates the volume with all excursions. Free breathing CBCT-ITV showed good agreement with AIP-ITV but underestimated the MIP-ITV. Estimation of excursions and centroid values for 4D-CT and CBCT were in good agreement with expected values.

60 APPLIED LIFE SCIENCES↗

A combined droplet train and ambient pressure photoemission spectrometer for the investigation of liquid/vapor interfaces

We describe a combined ambient pressure photoelectron spectroscopy/droplet train apparatus for investigating the nature and heterogeneous chemistry of liquid/vapor interfaces. In this instrument a liquid droplet train with typical droplet diameters from 50...150 {micro}m is produced by a vibrating orifice aerosol generator (VOAG). The droplets are irradiated by soft X-rays (100...1500 eV) in front of the entrance aperture of a differentially pumped electrostatic lens system that transfers the emitted electrons into a conventional hemispherical electron analyzer. The photoemission experiments are performed at background pressures of up to several Torr, which allows the study of environmentally important liquid/vapor interfaces, in particular aqueous solutions, under equilibrium conditions. The exposure time of the droplet surface to the background gases prior to the XPS measurement can be varied, which will allow future kinetic measurements of gas uptake on liquid surfaces. As an example, a measurement of the surface composition of a {chi} = 0.21 aqueous methanol solution is presented. The concentration of methanol at the vapor/liquid interface is enhanced by a factor of about 3 over the bulk value, while the expected bulk value is recovered at depths larger than about 1.5 nm.

54 ENVIRONMENTAL SCIENCES↗

System and method for energy reduction based on history of reliability of a system

A system and method for managing operating parameters within a system for optimal power and reliability are described. A device includes a functional unit and a corresponding reliability evaluator. The functional unit provides reliability information to one or more reliability monitors, which translate the information to reliability values. The reliability evaluator determines an overall reliability level for the system based on the reliability values. The reliability monitor compares the actual usage values and the expected usage values. When system has maintained a relatively high level of reliability for a given time interval, the reliability evaluator sends an indication to update operating parameters to reduce reliability of the system, which also reduces power consumption for the system.

Sadowski, Greg↗

EXPERIMENTAL INVESTIGATION OF THE ORTHO/PARA RATIO OF NEWLY FORMED MOLECULAR HYDROGEN ON AMORPHOUS SOLID WATER

Several astronomical observations have shown that the ortho/para ratio (OPR) of H{sub 2} can differ from the expected statistical value of 3 or the local thermodynamic equilibrium (LTE) value at the gas or dust temperature. It is thus important to know the OPR of H{sub 2} newly formed on dust grain surfaces, in order to clarify the dependence of the observed OPR in space on the formation process. Using an experimental setup designed to mimic interstellar medium environments, we measured the OPR of H{sub 2} and D{sub 2} formed on the surface of porous amorphous water ice held at 10 K. We report for the first time the OPR value for newly formed D{sub 2}, consistent with the expected LTE value at the high-temperature limit found by previous theoretical and experimental works on the determination of the OPR upon H{sub 2} formation on surfaces at low temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗