Search NASA⌕ Search

SEARCH · Search NASA

Results for “Excel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integration of (208) oriented epitaxial Hf-doped Bi{sub 4}Ti{sub 3}O{sub 12} with (0002) GaN using SrTiO{sub 3}/TiO{sub 2} buffer layer

Hf-doped Bi{sub 4}Ti{sub 3}O{sub 12} (BTH) ferroelectric films with excellent electrical properties were epitaxially integrated with GaN semiconductor using (111) SrTiO{sub 3} (STO)/rutile (200) TiO{sub 2} as buffer layer. The STO/TiO{sub 2} buffer layer was deposited by laser molecular beam epitaxy. The structural characteristics of the buffer layer were in situ and ex situ characterized by reflective high energy electron diffraction, x-ray diffraction (XRD), and high resolution transmission microscopy. The overlaying SrRuO{sub 3} (SRO) and BTH films were then deposited by pulsed laser deposition. XRD spectra, including theta-2theta and PHI scans, show that the (208) BTH films were epitaxially grown on GaN, and the BTH films inherit the in-plane twin-domain of STO buffer layer. Electrical measurements demonstrate that the non-c axis BTH films possess a large remnant polarization (2P{sub r}=45 muC/cm{sup 2}), excellent fatigue endurance (10.2% degradation after 1.1x10{sup 10} switching cycles), and a low leakage current density (1.94x10{sup -7} A/cm{sup 2} at an electric field of 200 kV/cm). These results reveal that the (208) BTH films with favorable electrical performance could be epitaxially grown on GaN template using STO/TiO{sub 2} buffer layer.

36 MATERIALS SCIENCE↗

A Seeman–Bohlin geometry for high-resolution nanosecond x-ray diffraction measurements from shocked polycrystalline and amorphous materials [Shock compression measurement in a Seeman-Bohlin camera geometry developed for time-resolved x-ray diffraction studies of shocked polycrystalline and amorphous materials]

Here, we report on a focusing x-ray diffraction geometry capable of high-resolution in situ lattice probing from dynamically loaded polycrystalline and amorphous materials. The Seeman–Bohlin-type camera presented here is ideally suited for time-resolved x-ray diffraction measurements performed on high energy multibeam laser platforms. Diffraction from several lattice planes of ablatively shock-loaded 25 μm thick Cu foils was recorded on a focusing circle of diameter D=100 mm with exceptional angular resolution limited only by the spectral broadening of the x-ray source. Excellent agreement was found between the density measured using x-ray diffraction and that inferred from Doppler velocimetry and the known shock Hugoniot of Cu. In addition, x-ray diffraction signal was captured from an amorphous material under static conditions.

36 MATERIALS SCIENCE↗

Plasma enhanced chemical vapor deposition of wear resistant gradual a-Si{sub 1-x}:C{sub x}:H coatings on nickel-titanium for biomedical applications

Plasma enhanced chemical vapor deposition has been used to deposit thin films with gradual transitions from silicon to carbon on Cu, Ni, stainless steel, and NiTi. Thus show low stress, elasticity, and wear resistance with excellent adhesion on all metals under investigation. Already at low Si concentrations of 10 at. % the intrinsic stress is considerably reduced compared to pure diamondlike carbon (DLC) films. The deposition process is controlled by optical emission spectroscopy. This technique has been applied to monitor the growth precursors and to correlate them with the film composition. The compositions of the films were determined by Rutherford backscattering spectroscopy and XPS measurements. Due to the elastic properties of the gradual transition and the excellent biocompatibility of DLC, the described film systems present a useful coating for biomedical applications.

36 MATERIALS SCIENCE↗

Nonlinear three-dimensional verification of the $\small \mathrm{SPECYL}$ and $\small \mathrm{PIXIE3D}$ magnetohydrodynamics codes for fusion plasmas

With the increasing impact of scientific discovery via advanced computation, there is presently a strong emphasis on ensuring the mathematical correctness of computational simulation tools. Such endeavor, termed verification, is now at the center of most serious code development efforts. In this study, we address a cross-benchmark nonlinear verification study between two three-dimensional magnetohydrodynamics (3D MHD) codes for fluid modeling of fusion plasmas, SPECYL [S. Cappello and D. Biskamp, Nucl. Fusion 36, 571 (1996)] and PIXIE3D [L. Chacón, Phys. Plasmas 15, 056103 (2008)], in their common limit of application: the simple viscoresistive cylindrical approximation. SPECYL is a serial code in cylindrical geometry that features a spectral formulation in space and a semi-implicit temporal advance, and has been used extensively to date for reversed-field pinch studies. PIXIE3D is a massively parallel code in arbitrary curvilinear geometry that features a conservative, solenoidal finite-volume discretization in space, and a fully implicit temporal advance. The present study is, in our view, a first mandatory step in assessing the potential of any numerical 3D MHD code for fluid modeling of fusion plasmas. Finally, excellent agreement is demonstrated over a wide range of parameters for several fusion-relevant cases in both two- and three-dimensional geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute np and pp Cross Section Determinations Aimed At Improving The Standard For Cross Section Measurements

Purpose of present research is a keeping improvement of the standard for cross section measurements of neutron-induced reactions. The cross sections for np and pp scattering below 1 GeV are determined based on partial-wave analyses (PWAs) of nucleon-nucleon scattering data. These cross sections are compared with the most recent ENDF/B-VII.0 and JENDL-4.0 data files, and the Nijmegen PWA. Also a comparison of evaluated data with recent experimental data was made to check a quality of evaluation. Excellent agreement was found between the new experimental data and our PWA predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Group velocity and pulse lengthening of mismatched laser pulses in plasma channels

Analytic solutions are presented to the non-paraxial wave equation describing an ultra-short, low-power, laser pulse propagating in a plasma channel. Expressions for the laser pulse centroid motion and laser group velocity are derived, valid for matched and mismatched propagation in a parabolic plasma channel, as well as in vacuum, for an arbitrary Laguerre-Gaussian laser mode. The group velocity of a mismatched laser pulse, for which the laser spot size is strongly oscillating, is found to be independent of propagation distance and significantly less than that of a matched pulse. Laser pulse lengthening of a mismatched pulse owing to laser mode slippage is examined and found to dominate over that due to dispersive pulse spreading for sufficiently long pulses. Analytic results are shown to be in excellent agreement with numerical solutions of the full Maxwell equations coupled to the plasma response. Implications for plasma channel diagnostics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low interfacial trap density and sub-nm equivalent oxide thickness in In{sub 0.53}Ga{sub 0.47}As (001) metal-oxide-semiconductor devices using molecular beam deposited HfO{sub 2}/Al{sub 2}O{sub 3} as gate dielectrics

We investigated the passivation of In{sub 0.53}Ga{sub 0.47}As (001) surface by molecular beam epitaxy techniques. After growth of strained In{sub 0.53}Ga{sub 0.47}As on InP (001) substrate, HfO{sub 2}/Al{sub 2}O{sub 3} high-{kappa} oxide stacks have been deposited in-situ after surface reconstruction engineering. Excellent capacitance-voltage characteristics have been demonstrated along with low gate leakage currents. The interfacial density of states (D{sub it}) of the Al{sub 2}O{sub 3}/In{sub 0.53}Ga{sub 0.47}As interface have been revealed by conductance measurement, indicating a downward D{sub it} profile from the energy close to the valence band (medium 10{sup 12} cm{sup -2}eV{sup -1}) towards that close to the conduction band (10{sup 11} cm{sup -2}eV{sup -1}). The low D{sub it}'s are in good agreement with the high Fermi-level movement efficiency of greater than 80%. Moreover, excellent scalability of the HfO{sub 2} has been demonstrated as evidenced by the good dependence of capacitance oxide thickness on the HfO{sub 2} thickness (dielectric constant of HfO{sub 2}{approx}20) and the remained low D{sub it}'s due to the thin Al{sub 2}O{sub 3} passivation layer. The sample with HfO{sub 2} (3.4 nm)/Al{sub 2}O{sub 3} (1.2 nm) as the gate dielectrics has exhibited an equivalent oxide thickness of {approx}0.93 nm.

36 MATERIALS SCIENCE↗

LaCrO3 heteroepitaxy on SrTiO3(001) by molecular beam epitaxy

Stoichiometric, epitaxial LaCrO3 films have been grown on TiO2-terminated SrTiO3(001) substrates by molecular beam epitaxy using O2 as the oxidant. Film growth occurred in a layer-by-layer fashion, giving rise to structurally excellent films and surfaces which preserve the step-terrace structure of the substrate. The critical thickness is in excess of 500 Å. Near-surface Cr(III) is highly susceptible to further oxidation to Cr(V), leading to the formation of a disordered phase upon exposure to atomic oxygen. Recovery of the original epitaxial LaCrO3 phase is readily achieved by vacuum annealing.

36 MATERIALS SCIENCE↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

Nanostructured ion beam-modified Ge films for high capacity Li ion battery anodes

Nanostructured ion beam-modified Ge electrodes fabricated directly on Ni current collector substrates were found to exhibit excellent specific capacities during electrochemical cycling in half-cell configuration with Li metal for a wide range of cycling rates. Structural characterization revealed that the nanostructured electrodes lose porosity during cycling but maintain excellent electrical contact with the metallic current collector substrate. These results suggest that nanostructured Ge electrodes have great promise for use as high performance Li ion battery anodes.

36 MATERIALS SCIENCE↗

A dark-field microscope for background-free detection of resonance fluorescence from single semiconductor quantum dots operating in a set-and-forget mode

Optically active quantum dots, for instance self-assembled InGaAs quantum dots, are potentially excellent single photon sources. The fidelity of the single photons is much improved using resonant rather than non-resonant excitation. With resonant excitation, the challenge is to distinguish between resonance fluorescence and scattered laser light. We have met this challenge by creating a polarization-based dark-field microscope to measure the resonance fluorescence from a single quantum dot at low temperature. We achieve a suppression of the scattered laser exceeding a factor of 10{sup 7} and background-free detection of resonance fluorescence. The same optical setup operates over the entire quantum dot emission range (920–980 nm) and also in high magnetic fields. The major development is the outstanding long-term stability: once the dark-field point has been established, the microscope operates for days without alignment. The mechanical and optical designs of the microscope are presented, as well as exemplary resonance fluorescence spectroscopy results on individual quantum dots to underline the microscope's excellent performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Furthermore, surface event rejection capabilities were tested with two 210 Pb sources producing ~130 beta decays/hr. We found that in ~800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 x 10 -5 at 90% C.L., corresponding to<0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy photon search experiment at JLAB

The Heavy Photon Search (HPS) experiment in Hall-B at Jefferson Lab will search for new heavy vector boson(s), aka 'heavy photons', in the mass range of 20 MeV/c{sup 2} to 1000 MeV/c{sup 2} using the scattering of high energy, high intensity electron beams off a high Z target. The proposed measurements will cover the region of parameter space favored by the muon g-2 anomaly, and will explore a significant region of parameter space, not only at large couplings (α′/α > 10{sup −7}), but also in the regions of small couplings, down to α′/α∼10{sup −10}. The excellent vertexing capability of the Si-tracker uniquely enables HPS to cover the small coupling region. Also, HPS will search for heavy photons in an alternative to the e{sup +}e{sup −} decay mode, in the heavy photon's decay to μ{sup +}μ−.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dielectric property of NiTiO{sub 3} doped substituted ortho-chloropolyaniline composites

Ortho-chloropolyaniline (OCP)-NiTiO{sub 3} composites have been synthesized via in-situ polymerization of ortho-chloroaniline with various weight percentages of NiTiO{sub 3.} Fourier Transform Infrared spectroscopic studies of Ortho-chloropolyaniline and its composites indicated the formation of composites as a result of Vander Waal's interaction between OCP and NiTiO{sub 3} particles. Surface morphology of OCP and OCP-NiTiO{sub 3} composites were studied using Scanning Electron Microscope (SEM). The SEM micrographs indicated a modified morphology after the composite formation. Dielectric properties and electric modulus of OCP and OCP-NiTiO{sub 3} composites have been investigated in the frequency range of 50 Hz – 5 MHz. It has been noticed that electrical resistance decreases with increase in weight percentage of NiTiO{sub 3} particles in polymer matrix as well as with applied frequency. The display of semicircular arcs in Cole-Cole plots indicates the formation of series resistor and capacitor in network causing a decrease in the relaxation time and as a result conductivity enhances in these composites. The facile and cost effective synthesis process and excellent dielectric and conductivity response of these materials makes them promising materials for practical applications.

36 MATERIALS SCIENCE↗

Rotational spectroscopy of pyridazine and its isotopologs from 235–360 GHz: Equilibrium structure and vibrational satellites

The rotational spectrum of pyridazine (o-C{sub 4}H{sub 4}N{sub 2}), the ortho disubstituted nitrogen analog of benzene, has been measured and analyzed in the gas phase. For the ground vibrational state of the normal isotopolog, over 2000 individual rotational transitions have been identified between 238 and 360 GHz and have been fit to 13 parameters of a 6th-order centrifugal distortion Hamiltonian. All transitions in this frequency region can now be predicted from this model to near experimental accuracy, i.e., well enough for the purpose of any future radio-astronomical search for this species. Three isotopologs, [3-{sup 13}C]-C{sub 4}H{sub 4}N{sub 2}, [4-{sup 13}C]-C{sub 4}H{sub 4}N{sub 2}, and [1-{sup 15}N]-C{sub 4}H{sub 4}N{sub 2}, have been detected in natural abundance, and several hundred lines have been measured for each of these species and fit to 6th-order Hamiltonians. Ten additional isotopologs were synthesized with enhanced deuterium substitution and analyzed to allow for a complete structure determination. The equilibrium structure (R{sub e}) of pyridazine was obtained by correcting the experimental rotational constants for the effects of vibration-rotation coupling using interaction constants predicted from CCSD(T) calculations with an ANO0 basis set and further correcting for the effect of electron mass. The final R{sub e} structural parameters are determined with excellent accuracy, as evidenced by their ability to predict 28 independent moments of inertia (I{sub a} and I{sub b} for 14 isotopologs) very well from 9 structural parameters. The rotational spectra of the six lowest-energy fundamental vibrational satellites of the main isotopolog have been detected. The rotational spectra of the five lowest-energy vibrational satellites have been assigned and fit to yield accurate rotational and distortion constants, while the fit and assignment for the sixth is less complete. The resultant vibration-rotation interaction (α) constants are found to be in excellent agreement with ones predicted from coupled-cluster calculations, which proved to be the key to unambiguous assignment of the satellite spectra to specific vibration modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New experimental approaches to search for neutrino mass

In order to obtain high sensitivity in the study of the neutrino mass it is necessary to design experiments able to optimize all the sensitivity parameters. One of the most promising techniques to achieve this goal is the bolometric technique because of its intrinsic characteristics: high detection efficiency, excellent energy resolution, low intrinsic background and the possibility to study many different compounds. The bolometric technique has already obtained excellent results on the neutrino mass study with Cuoricino. The Cuoricino experiment has also shown that surface contaminations of materials facing the detectors would be the limiting factor for the sensitivity of next generation experiments with bolometers. Mainly for this reason scintillating bolometers have been developed allowing a very efficient discrimination of alpha particles thanks to their double readout. Tests performed on these crystals showed moreover the possibility to discriminate the interacting particles through a pulse shape analysis. This feature is very promising because it allows to reach the same results on the background reduction obtained with the hybrid detectors but without complicating the experimental assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗