Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Queen bees offload pesticide burden to eggs when social buffering is overwhelmed

Honey bee colonies pollinate about one-third of the world’s food crops, and their rapid decline directly threatens agricultural productivity and ecosystem stability. Understanding how colony-level social defenses influence pesticide fate and the circumstances under which they fail is therefore a crucial question in pollinator biology. We used biological accelerator mass spectrometry (BioAMS), a sensitive radiotracer technique, to track the movement of a model pesticide through a small honey bee colony under laboratory conditions. We tested the hypothesis that social buffering protects honey bees from toxic accumulation and that this protection can be overcome, leading to maternal offloading of the pesticide to developing eggs. Consistent with this hypothesis, our results identified three key mechanisms governing chemical movement within a social insect colony: (1) worker bees initially decrease dietary pesticide levels by 95% through diet filtering and deposition in honeycombs, though this declines to 86% by day 10; (2) queen bees maintain markedly lower pesticide levels than workers but, over time, they accumulate the pesticide in their ovaries and transfer it into developing eggs, revealing a previously undocumented protective mechanism in reproductive individuals; and (3) the presence of a queen bee shifts colony-wide chemical distribution by concentrating worker exposure and increasing pesticide deposition in wax. Our findings show that honey bee colonies function as integrated detoxification networks, in which chemical fate depends on complex social behaviors and caste-specific physiology. When social buffering is overwhelmed, reproductive queens may survive by transferring their chemical burden to their offspring.

Biological and medical sciences↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AutoSourceID-Classifier: Star-galaxy classification using a convolutional neural network with spatial information

Aims.Traditional star-galaxy classification techniques often rely on feature estimation from catalogs, a process susceptible to introducing inaccuracies, thereby potentially jeopardizing the classification’s reliability. Certain galaxies, especially those not manifesting as extended sources, can be misclassified when their shape parameters and flux solely drive the inference. We aim to create a robust and accurate classification network for identifying stars and galaxies directly from astronomical images. Methods.The AutoSourceID-Classifier (ASID-C) algorithm developed for this work uses 32x32 pixel single filter band source cutouts generated by the previously developed AutoSourceID-Light (ASID-L) code. By leveraging convolutional neural networks (CNN) and additional information about the source position within the full-field image, ASID-C aims to accurately classify all stars and galaxies within a survey. Subsequently, we employed a modified Platt scaling calibration for the output of the CNN, ensuring that the derived probabilities were effectively calibrated, delivering precise and reliable results. Results.We show that ASID-C, trained on MeerLICHT telescope images and using the Dark Energy Camera Legacy Survey (DECaLS) morphological classification, is a robust classifier and outperforms similar codes such as SourceExtractor. To facilitate a rigorous comparison, we also trained an eXtreme Gradient Boosting (XGBoost) model on tabular features extracted by SourceExtractor. While this XGBoost model approaches ASID-C in performance metrics, it does not offer the computational efficiency and reduced error propagation inherent in ASID-C’s direct image-based classification approach. ASID-C excels in low signal-to-noise ratio and crowded scenarios, potentially aiding in transient host identification and advancing deep-sky astronomy.

Astronomy & Astrophysics↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding ICF hohlraums using NIF gated laser-entrance-hole images

The newly available ns-gated laser-entrance-hole (LEH) imager on the National Ignition Facility provides routine, non-perturbative measurements of the x-ray emission from laser-heated plasmas inside the hohlraum as viewed at 19° to the hohlraum axis through one of its LEHs. Multiple images are acquired for a series of times and filter-selected x-ray energy bands within a single shot. The images provide time dependent data on phenomena including the effective radius of the LEH, the length of the gold-plasma “bubble” evolving off the interior wall surface heated by the outer beams, the evolving radius of the x-ray heated hohlraum wall, and the radius of the ablation front of the fusion capsule. Here, these measurements are explained and illustrated with sample data. These techniques are then applied to understand hohlraum behavior as a function of gas fill. For hohlraums with helium gas fill densities of 0.15 to 0.30 mg/cm 3 , synthetic images computed from simulations agree well with experimental gated LEH images when an inhibited heat transport model [Jones et al., Phys. Plasmas 24, 056312 (2017)] is used. This model can be adjusted to reproduce the expansion rate of the laser-heated plasma bubble in such a way as to improve agreement with the images. At the higher 0.6 mg/cc gas fill, the experimental images show more pronounced 3D features, resulting in slightly less good agreement with the 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WISE J163940.83-684738.6: A Y DWARF IDENTIFIED BY METHANE IMAGING

We have used methane imaging techniques to identify the near-infrared counterpart of the bright Wide-field Infrared Survey Explorer (WISE) source WISE J163940.83-684738.6. The large proper motion of this source ( Almost-Equal-To 3.''0 yr{sup -1}) has moved it, since its original WISE identification, very close to a much brighter background star-it currently lies within 1.''5 of the J = 14.90 {+-} 0.04 star 2MASS 16394085-6847446. Observations in good seeing conditions using methane-sensitive filters in the near-infrared J band with the FourStar instrument on the Magellan 6.5 m Baade telescope, however, have enabled us to detect a near-infrared counterpart. We have defined a photometric system for use with the FourStar J2 and J3 filters, and this photometry indicates strong methane absorption, which unequivocally identifies it as the source of the WISE flux. Using these imaging observations we were then able to steer this object down the slit of the Folded-port Infrared Echellette spectrograph on a night of 0.''6 seeing, and so obtain near-infrared spectroscopy confirming a Y0-Y0.5 spectral type. This is in line with the object's near-infrared-to-WISE J3 - W2 color. Preliminary astrometry using both WISE and FourStar data indicates a distance of 5.0 {+-} 0.5 pc and a substantial tangential velocity of 73 {+-} 8 km s{sup -1}. WISE J163940.83-684738.6 is the brightest confirmed Y dwarf in the WISE W2 passband and its distance measurement places it among the lowest luminosity sources detected to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Selective Detection in Impulsive Low-Frequency Raman Imaging Using Shaped Probe Pulses

Impulsive stimulated Raman scattering (ISRS) using a single short femtosecond pump pulse to excite molecular vibrations offers an elegant pump-probe approach to perform vibrational imaging below 200 cm –1 . One shortcoming of ISRS is its inability to offer vibrational selectivity as all the vibrational bonds whose frequencies lie within the short pump-pulse bandwidth are excited. To date, several coherent control techniques have been explored to address this issue and selectively excite a specific molecular vibration by shaping the pump pulse. There has not been any systematic work that reports an analogous shaping of the probe pulse to implement preferential detection. In this work, we focus on vibrational imaging and report vibrational selective detection by shaping the probe pulse in time. Here, we demonstrate numerically and experimentally two pulse-shaping strategies with one functioning as a vibrational notch filter and the other functioning as a vibrational low-pass filter. This enables fast (25 μs/pixel) and selective hyperspectral imaging in the low-frequency regime (< 200 cm –1 ).

74 ATOMIC AND MOLECULAR PHYSICS↗

Automatic Detection and Evaluation of Solar Cell Micro-Cracks in Electroluminescence Images Using Matched Filters

A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potential for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.

14 SOLAR ENERGY↗

Conversion of a TEM10 beam into two nearly Gaussian beams

To achieve high output power and/or high efficiencies, laser systems are often designed to operate with either high-order or multiorder transverse modes. This comes at the expense of beam quality. Herein, a technique for converting the two lobes of a higher-order (Hermite–Gaussian TEM10) beam into two TEM00 beams is discussed. It is shown that nearly 94% of the power in a single lobe of the TEM10 beam spatially overlaps an appropriately chosen TEM00 beam. Beam quality (defined by the M2 beam quality factor) is increased by separating the two TEM10 lobes with an edge aperture. A single-mode optical fiber can be used as a spatial filter to eliminate residual higher-order mode content. This study suggests that more than 90% of the power in a TEM10 beam can be converted into two separate TEM00 beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AUTOMATIC DETECTION AND TRACKING OF CORONAL MASS EJECTIONS. II. MULTISCALE FILTERING OF CORONAGRAPH IMAGES

Studying coronal mass ejections (CMEs) in coronagraph data can be challenging due to their diffuse structure and transient nature, and user-specific biases may be introduced through visual inspection of the images. The large amount of data available from the Solar and Heliospheric Observatory (SOHO), Solar TErrestrial RElations Observatory (STEREO), and future coronagraph missions also makes manual cataloging of CMEs tedious, and so a robust method of detection and analysis is required. This has led to the development of automated CME detection and cataloging packages such as CACTus, SEEDS, and ARTEMIS. Here, we present the development of a new CORIMP (coronal image processing) CME detection and tracking technique that overcomes many of the drawbacks of current catalogs. It works by first employing the dynamic CME separation technique outlined in a companion paper, and then characterizing CME structure via a multiscale edge-detection algorithm. The detections are chained through time to determine the CME kinematics and morphological changes as it propagates across the plane of sky. The effectiveness of the method is demonstrated by its application to a selection of SOHO/LASCO and STEREO/SECCHI images, as well as to synthetic coronagraph images created from a model corona with a variety of CMEs. The algorithms described in this article are being applied to the whole LASCO and SECCHI data sets, and a catalog of results will soon be available to the public.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction

Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.

60 APPLIED LIFE SCIENCES↗

Time domain simulations of arm locking in LISA

Arm locking is a proposed laser frequency stabilization technique for the Laser Interferometer Space Antenna (LISA), a gravitational-wave observatory sensitive in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that compose LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of a Kalman-filter-based arm-locking system that includes the expected limiting noise sources as well as the effects of imperfect a priori knowledge of the constellation geometry on which the design is based. We use the simulation to study aspects of the system performance that are difficult to capture in a steady-state frequency-domain analysis such as frequency pulling of the master laser due to errors in estimates of heterodyne frequency. We find that our implementation meets requirements on both the noise and dynamic range of the laser frequency with acceptable tolerances and that the design is sufficiently insensitive to errors in the estimated constellation geometry that the required performance can be maintained for the longest continuous measurement intervals expected for the LISA mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit

Purpose: The purpose of this work is to characterize the x-ray volume imager (XVI), the cone-beam computed tomography (CBCT) unit mounted on the Elekta Synergy linac, with F1 bowtie filter and to calculate the three-dimensional dose delivered to patients using volumetric acquisition. Methods: The XVI is modeled in detail using a new Monte Carlo (MC) code, BEAMPP, under development at the National Research Council Canada. In this investigation, a new component module is developed to accurately model the unit's bowtie filter used in conjunction with the available beam collimators at the clinical energy of 120 kV. The modeling is compared against percentage depth dose (PDD) and profile measurements. Kilovoltage radiation beams' phase space files are also analyzed. The authors also describe a method for the absolute dose calibration of the MC model of the CBCT unit when used in a clinical volumetric acquisition mode. Finally, they calculate three-dimensional patient dose from CBCT image acquisition in three clinical cases of interest: Pelvis, lung, and head and neck. Results: The agreement between measurement and MC is shown to be very good: Within {+-}2% for the PDD and within {+-}3.5% inside the radiation field for all the collimators with the F1 bowtie filter. A full account of the absolute calibration method is given and dose calculation is validated against ion chamber measurements in different locations of a plastic phantom. Calculations and experiments agree within {+-}2% or better in both at the center and the periphery of the phantom, with worst agreement of 4.5% at the surface of the phantom and for one specific combination of collimator and filter. Patient dose from CBCT scan reveals that dose to tissue is between 2 and 2.5 cGy for a pelvis or a lung full acquisition. For H and N dose to tissue is 5 cGy, with the unit presets used in this work. Dose to bony structures can be two to three times higher than dose to tissue. Conclusions: The XVI CBCT unit has been fully modeled including the F1 bowtie filter. Absolute dose distribution from the unit has been successfully validated. Full MC patient dose calculation has shown that the three-dimensional dose distribution from CBCT is complex. Patient dose from CBCT exposure cannot be completely accounted for by using a numerical factor as an estimate of the dose at the center of the body. Furthermore, additional dose to bone should be taken into account when adopting any IGRT strategy and weighed vs the unquestionable benefits of the technique in order to optimize treatment. Full three-dimensional dose calculation is recommended if patient dose from CBCT is to be integrated in any adaptive planning strategy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A method for extracting calibrated volatility information from the FIGAERO-HR-ToF-CIMS and its experimental application

The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.

47 OTHER INSTRUMENTATION↗

Method for Hot Real-Time Sampling of Pyrolysis Vapors

Biomass Pyrolysis has been an increasing topic of research, in particular as a replacement for crude oil. This process utilizes moderate temperatures to thermally deconstruct the biomass which is then condensed into a mixture of liquid oxygenates to be used as fuel precursors. Pyrolysis oils contain more than 400 compounds, up to 60 percent of which do not re-volatilize for subsequent chemical analysis. Vapor chemical composition is also complicated as additional condensation reactions occur during the condensation and collection of the product. Due to the complexity of the pyrolysis oil, and a desire to catalytically upgrade the vapor composition before condensation, online real-time analytical techniques such as Molecular Beam Mass Spectrometry (MBMS) are of great use. However, in order to properly sample hot pyrolysis vapors, many challenges must be overcome. Sampling must occur within a narrow range of temperatures to reduce product composition changes from overheating or partial condensation or plugging of lines from condensed products. Residence times must be kept at a minimum to reduce further reaction chemistries. Pyrolysis vapors also form aerosols that are carried far downstream and can pass through filters resulting in build-up in downstream locations. The co-produced bio-char and ash from the pyrolysis process can lead to plugging of the sample lines, and must be filtered out at temperature, even with the use of cyclonic separators. A practical approach for considerations and sampling system design, as well as lessons learned are integrated into the hot analytical sampling system of the National Renewable Energy Laboratory's (NREL) Thermochemical Process Development Unit (TCPDU) to provide industrially relevant demonstrations of thermochemical transformations of biomass feedstocks at the pilot scale.

09 BIOMASS FUELS↗

Real-time microstructure imaging by Laue microdiffraction: A sample application in laser 3D printed Ni-based superalloys

Synchrotron-based Laue microdiffraction has been widely applied to characterize the local crystal structure, orientation, and defects of inhomogeneous polycrystalline solids by raster scanning them under a micro/nano focused polychromatic X-ray probe. In a typical experiment, a large number of Laue diffraction patterns are collected, requiring novel data reduction and analysis approaches, especially for researchers who do not have access to fast parallel computing capabilities. In this article, a novel approach is developed by plotting the distributions of the average recorded intensity and the average filtered intensity of the Laue patterns. Visualization of the characteristic microstructural features is realized in real time during data collection. As an example, this method is applied to image key features such as microcracks, carbides, heat affected zone, and dendrites in a laser assisted 3D printed Ni-based superalloy, at a speed much faster than data collection. Such analytical approach remains valid for a wide range of crystalline solids, and therefore extends the application range of the Laue microdiffraction technique to problems where real-time decision-making during experiment is crucial (for instance time-resolved non-reversible experiments).

36 MATERIALS SCIENCE↗

Estimating luminosities and stellar masses of galaxies photometrically without determining redshifts

Large direct imaging surveys usually use a template-fitting technique to estimate photometric redshifts for galaxies, which are then applied to derive important galaxy properties such as luminosities and stellar masses. These estimates can be noisy and suffer from systematic biases because of the possible mis-selection of templates and the propagation of the photometric redshift uncertainty. We introduce an algorithm, the Direct Empirical Photometric method (DEmP), that can be used to directly estimate these quantities using training sets, bypassing photometric redshift determination. DEmP also applies two techniques to minimize the effects arising from the non-uniform distribution of training set galaxy redshifts from a flux-limited sample. First, for each input galaxy, fitting is performed using a subset of the training set galaxies with photometry and colors closest to those of the input galaxy. Second, the training set is artificially resampled to produce a flat distribution in redshift or other properties, e.g., luminosity. To test the performance of DEmP, we use a four filter-band mock catalog to examine its ability to recover redshift, luminosity, stellar mass, and luminosity and stellar mass functions. We also compare the results to those from two publicly available template-fitting methods, finding that the DEmP algorithm outperforms both. We find that resampling the training set to have a uniform redshift distribution produces the best results not only in photometric redshift, but also in estimating luminosity and stellar mass. The DEmP method is especially powerful in estimating quantities such as near-IR luminosities and stellar mass using only data from a small number of optical bands.

79 ASTRONOMY AND ASTROPHYSICS↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗