Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Interoperability and the Federal Role

A smart grid is capable of integrating a broad array of generation resources and enables the participation of demand side resources in reliable system operation. To cost effectively realize this flexibility, the associated devices and systems need to connect and interact simply and reliably. Interoperability is the important ingredient to make this happen. Because the electric system transcends organizational boundaries between generators, electricity delivery companies, end-users, and other service providers, advancing interoperability between these organizations can be difficult to justify by individual organizations. But given the importance of a smart electric system to meet national economic, societal, and environmental objectives, a federal role is taking shape in the United States to improve the integration of automation elements and thus make smart grid a reality

99 GENERAL AND MISCELLANEOUS↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

Transactive Campus Energy Systems: An R&D Testbed for Renewables, Integration, Efficiency, and Grid Services (CRADA 356 / Amendment 1)

The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of Amendment 1 to Campus Cooperative Research and Development Agreement (CRADA) 356, the Transactive Campus CRADA with the Washington State Department of Commerce (Commerce) between the U.S. Department of Energy’s (DOE’s), Pacific Northwest National Laboratory (PNNL) and the Commerce through the Clean Energy Fund (CEF). The original project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to construct and operate the testbed as both a regional flexibility resource and as a platform for research and development (R&D) for buildings/grid integration. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for R&D on buildings/grid integration and information-based energy efficiency. The testbed supports the integration of renewables and other regional needs, using the flexibility provided by building loads, energy storage, and smart inverters for batteries and photovoltaic (PV) solar systems, at four physical scales: multiple campuses, campus, microgrid and building.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗

The added economic and environmental value of plug-in electric vehicles connected to commercial building microgrids

Connection of electric storage technologies to smartgrids or microgrids will have substantial implications for building energy systems. In addition to potentially supplying ancillary services directly to the traditional centralized grid (or macrogrid), local storage will enable demand response. As an economically attractive option, mobile storage devices such as plug-in electric vehicles (EVs) are in direct competition with conventional stationary sources and storage at the building. In general, it is assumed that they can improve the financial as well as environmental attractiveness of renewable and fossil based on-site generation (e.g. PV, fuel cells, or microturbines operating with or without combined heat and power). Also, mobile storage can directly contribute to tariff driven demand response in commercial buildings. In order to examine the impact of mobile storage on building energy costs and carbon dioxide (CO2) emissions, a microgrid/distributed-energy-resources (DER) adoption problem is formulated as a mixed-integer linear program with minimization of annual building energy costs applying CO2 taxes/CO2 pricing schemes. The problem is solved for a representative office building in the San Francisco Bay Area in 2020. By using employees' EVs for energy management, the office building can arbitrage its costs. But since the car battery lifetime is reduced, a business model that also reimburses car owners for the degradation will be required. In general, the link between a microgrid and an electric vehicle can create a win-win situation, wherein the microgrid can reduce utility costs by load shifting while the electric vehicle owner receives revenue that partially offsets his/her expensive mobile storage investment. For the California office building with EVs connected under a business model that distributes benefits, it is found that the economic impact is very limited relative to the costs of mobile storage for the site analyzed, i.e. cost reductions from electric vehicle connections are modest. Nonetheless, this example shows that some economic benefit is created because of avoided demand charges and on-peak energy. The strategy adopted by the office building is to avoid these high on-peak costs by using energy from the mobile storage in the business hours. CO2 emission reduction strategy results indicate that EVs' contribution at the selected office building are minor.

25 ENERGY STORAGE↗

Fabrication and Tests of a Resistive-Type Superconducting Fault Current Limiter Module Based on Coated Conductors

The resistivetype superconducting fault current limiter (R-SFCL) is simple in structure, near zero impedance at normal state and can be quickly triggered by the fault current. Thus, it is a possible solution to limit the fault current in the power grid. In this paper, we report the fabrication and test for an R-SFCL module The R-SFCL module consists of seven bifilar coils connected in parallel, which were wound with two parallel 2G tapes. A 5mm spacer was co-wound between adjacent turns to act as the highvoltage insulation. In the tests, we test the current distribution among the bifilar coils, and then simulated short-circuit tests were conducted on the module to obtain its performance under fault current surge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flow behavior of hydraulic fractured tight formations considering Pre-Darcy flow using EDFM

For tight reservoirs/formations, flow in fracture and matrix obey different flow patterns. Pre-Darcy flow always exists in low permeability subsurface porous media while Darcy flow can be applied in fracture. It is an outstanding challenge to understand the flow behavior coupling different flow mechanisms. As numerical simulation can predict field-scale performance so the development of efficient simulation method becomes a key issue to evaluate the flow behavior. In this paper, we develop an improved discrete fracture model based on the widely used embedded discrete facture model (EDFM) to simulate the transport both in homogenous and heterogeneous porous media in the presence of Pre-Darcy flow. The conservation equations are derived for fracture and matrix firstly and then discretized by fully implicit method. The transmissibility of different connection types is defined and the detailed calculation workflow is presented as well. The proposed model is verified through the comparison with the model using local grid refined (LGR) method. It is discovered that our simulation method exhibits good accuracy when analyzing the effect of Pre-Darcy flow. Some examples are shown including 1D scalar transport, 2D heterogeneous, 3D flow, complex fracture system and multiple well system problems with fully-coupled flow in fracture and matrix. The pressure distribution and well flux are demonstrated to analyze the Pre-Darcy flow characteristics. Results indicate that the new model works robustly for different flow problems which provide further insight into the Pre-Darcy flow in low permeability media.

02 PETROLEUM↗

Short-depth QAOA circuits and quantum annealing on higher-order ising models

Abstract We present a direct comparison between QAOA (Quantum Alternating Operator Ansatz), and QA (Quantum Annealing) on 127 qubit problem instances. QAOA with p = 1, 2 rounds is executed on the 127 qubit heavy-hex graph gate-model quantum computer ibm_washington, using on-device grid-searches for angle finding, and QA is executed on two Pegasus-chip D-Wave quantum annealers. The problems are random Ising models whose connectivity matches heavy-hex graphs and the Pegasus graph connectivity, and optionally include hardware-compatible cubic terms ( Z Z Z terms). The QAOA circuits are heavily optimized and of extremely short depth, with a CNOT depth of 6 per round, which allows whole chip usage of the heavy-hex lattice. QAOA and QA are both compared against simulated annealing and the optimal solutions are computed exactly using CPLEX. The noiseless mean QAOA expectation values for p = 1, 2 are computed using classical light-cone based simulations. We find QA outperforms QAOA on the evaluated devices.

127 qubits↗

CMS centres worldwide: A new collaborative infrastructure

The CMS Experiment at the LHC has established a network of more than fifty inter-connected 'CMS Centres' at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running 'telepresence' video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Conservation Behavior in Several Variationally Derived Implementations for Simulating Electromagnetic Plasmas

Variational techniques based on Low's Lagrangian formulation have demonstrated significant improvement in conservation properties as compared to traditional particle-in-cell (PIC) algorithms. Previous work showed that equations derived from a discretized Lagrangian preserve a discretized version of the connection between Lagrangian symmetries and conservation laws, i.e., Noether's theorem. Specifically, a thorough analysis of energy conservation within the new system explained the absence of “grid heating” phenomena. In the present work, variationally derived implementations in a gridded periodic domain were compared to analogous implementations using Fourier bases. Since the Fourier basis allows for exact momentum conservation, this approach enables us to compare the relative merits of exact and approximate momentum conservation. Furthermore, to establish a tangible comparison for numerical methods, we investigate two simple physical examples; (1) the coupling of an electrostatic and electromagnetic plasma wave and (2) an equilibrium supporting Weibel instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-optimal evaluation of centralized and distributed microgrid topologies considering voltage constraints

Optimal design of hybrid renewable mini-grids requires both economic and power quality considerations. Existing modeling approaches address these considerations via separate or loosely coupled models. Here, we extend REopt—a techno-economic optimization model developed at the National Renewable Energy Laboratory—to consider both within a single model. REopt formulates the design problem as a mixed-integer linear program that solves for a site's optimal technology mix, sizing, and operation to minimize life cycle cost. REopt has traditionally assumed a single node system. In the work presented here, we expand the REopt platform to consider multiple connected nodes with associated voltage constraints. In order to do this, we model power flow using a fixed-point linear approximation method. Additionally, we then use the model to explore design considerations of mini-grids in Sub-Saharan Africa. Specifically, we evaluate under what combinations of transmission line distance and capacity it is technically viable and economically preferable to build multiple isolated mini-grids versus an interconnected, centralized system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen ionic plasma generated using Al plasma grid

Negative hydrogen ions are produced in the apertures of a plasma grid made of aluminum under the irradiation of positive ions, generating an ionic plasma consisting of positive and negative ions. The saturation current ratio obtained using a Langmuir probe reflects the existence ratio of electrons and is found to increase in connection with the diffusion of the ionic plasma. The local increment of the current ratio suggests the collapse of negative ions and the replacement of detached electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GMLC Technical Assistance to States

This presentation provides an overview of the U.S. Department of Energy's Grid Modernization Laboratory Consortium (GMLC) efforts to provide customized technical support specific to state public utility commissions (PUCs), specifically on the integration of distributed energy resources (DERs). The goals are to increase awareness of existing materials and support to help state PUCs move forward on DER interconnection activities, to help participants make connections to colleagues with similar challenges (and solutions), and to help the GMLC/National Renewable Energy Laboratory project team understand context and implementation challenges.

DER↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

A Game-Theoretic Approach to Modeling Attacks and Defenses of Smart Grids at Three Levels

As optimization, user capabilities, and data-taking abilities are incorporated into next-generation power grids, or smart grids, they face cyber threats. The traditional electrical grid could only be damaged by physical attacks; however thesmart grid can suffer remote/cyber attacks, which have not been studied extensively in the literature. The electrical grid forms the backbone of the modern society and its security has significant implications in military settings. This paper applies game theory to model three-levels (power plants, transmission, and distribution networks) of defenses and attacks in smart grid network security. We characterize both the attacker and the defender (who interact at three network levels: distribution, transmission, and power plants) best responses and equilibrium strategies. We find that the defender's best response is not only a function of direct attacks but also of the spread from connected networks. Sensitivity analyses of the equilibrium strategies show that when success probability of an attack against power plantsreaches a threshold, the defender increases defending efforts for power plants. In contrast, the attack eort at all levels is not affected by this probability. This paper provides some novel insights to modeling and analyzing the emerging threats to the growing smart grid networks.

Rao, Nageswara S.↗