Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hunting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,242 records · Page 69

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

Motor Control Center Design

This poster contains information dealing with the design of a Motor Control Center that drives an exhaust, heating and lighting system inside a deep well house.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag $^{214}$Pb beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each $^{214}$Pb atom up to 81 minutes after production, resulting in (63 $\pm$ 6$_{\mathrm{stat}}$ $\pm$ 7$_{\mathrm{sys}}$)% identification of $^{214}$Pb decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Presentation to State Agencies

Slides used to present roadmap to state agencies, EEI stakeholders, EPA stakeholders, and other conferences

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Workflow for Process Automation of Soil Gas Results from an Automated Soil Gas-Sampling System for Application in Carbon Storage Projects

Extended abstract for Geoconvention, Calgary, Alberta, Canada, May 12–14, 2025. The Energy & Environmental Research Center (EERC) developed an automated workflow for processing soil gas measurements collected from the automated soil gas-sampling systems deployed across the project site. Raw soil gas measurements are collected from each station every 4 hours and automatically uploaded to a cloud database. The workflow begins by writing code to download the data to a workstation automatically, then the data are published to an online dashboard that visualizes the measurements in time-series plots and a process-based decision-making framework. This automated workflow accelerates the time from data acquisition to decision-making. It supports carbon storage project operators by preparing and delivering a live, standardized dataset for quick analysis and source attribution to provide assurance of containment and overall permit compliance.

02 PETROLEUM↗

Measurement of the Muon Flux at the Sanford Underground Research Facility with the LUX-ZEPLIN Dark Matter Detector

High-energy cosmic-ray muons reaching deep underground laboratories can cause events in detectors that mimic signals expected from dark matter particles, neutrinos, or rare decays. Knowledge of the muon flux and energy spectrum is important for evaluating the background rate caused by muons and their secondaries. In this paper, we report the measurement of the cosmic-ray muon flux in the Davis Campus of the Sanford Underground Research Facility with the LUX-ZEPLIN detector. Using 366.4~days of exposure, the muon rate through the detector was measured as $10.94\pm0.17_\textrm{stat.}~\textrm{day}^{-1}$ with energy thresholds of 20~MeV in the inner xenon detector and 8 MeV in the outer liquid scintillator detector. This rate corresponds to a muon flux of $(5.09\pm0.08_\textrm{stat.}\pm0.10_\textrm{sys.})\times10^{-9}~\textrm{cm}^{-2}\textrm{s}^{-1}$ in the Davis Cavern.

Akerib, D. S. [SLAC; Stanford U., Phys. Dept.; KIP↗

Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs

The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$%, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Synthesis, Reactivity Investigation, and X-ray Diffraction Structures of New Platinum(II) Compounds Containing Redox-Active Diphosphine Ligands

Substitution of the 1,5-cyclooctadiene (cod) ligand in PtCl2(cod) (1) by the diphosphine ligand 4,5-bis(diphenylphosphino)-4-cyclopenten-1,3-dione (bpcd) yields PtCl2(bpcd) (2). Knoevenagel condensation of 2 with 9-anthracenecarboxaldehyde leads to the functionalization of the bpcd ligand and formation of the corresponding 2-(9-anthracenylidene)-4,5-bis(diphenylphosphino)-4-cyclopenten-1,3-dione (abpcd) substituted compound PtCl2(abpcd) (3), which is also obtained from the direct reaction of 1 with the abpcd ligand in near quantitative yield. The reaction of 3 with disodium maleonitriledithiolate (Na2mnt) affords the chelating dithiolate compound Pt(mnt)(abpcd) (4). Compounds 2 C4 have been fully characterized in solution by IR and NMR spectroscopies (1H and 31P), and their molecular structures established by X-ray crystallography. The electrochemical properties of 2 C4 have examined by cyclic voltammetry, and the nature of the HOMO and LUMO levels in these systems has been established by MO calculations at the extended H ckel level, the results of which are discussed with respect to electrochemical data and related diphosphine derivatives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A dynamic soil chamber system coupled with a tunable diode laser for online measurements of delta-13C, delta-18O, and efflux rate of soil respired CO2

High frequency observations of the stable isotopic composition of CO(2) effluxes from soil have been sparse due in part to measurement challenges. We have developed an open-system method that utilizes a flow-through chamber coupled to a tunable diode laser (TDL) to quantify the rate of soil CO(2) efflux and its delta(13)C and delta(18)O values (delta(13)C(R) and delta(18)O(R), respectively). We tested the method first in the laboratory using an artificial soil test column and then in a semi-arid woodland. We found that the CO(2) efflux rates of 1.2 to 7.3 micromol m(-2) s(-1) measured by the chamber-TDL system were similar to measurements made using the chamber and an infrared gas analyzer (IRGA) (R(2) = 0.99) and compared well with efflux rates generated from the soil test column (R(2) = 0.94). Measured delta(13)C and delta(18)O values of CO(2) efflux using the chamber-TDL system at 2 min intervals were not significantly different from source air values across all efflux rates after accounting for diffusive enrichment. Field measurements during drought demonstrated a strong dependency of CO(2) efflux and isotopic composition on soil water content. Addition of water to the soil beneath the chamber resulted in average changes of +6.9 micromol m(-2) s(-1), -5.0 per thousand, and -55.0 per thousand for soil CO(2) efflux, delta(13)C(R) and delta(18)O(R), respectively. All three variables initiated responses within 2 min of water addition, with peak responses observed within 10 min for isotopes and 20 min for efflux. The observed delta(18)O(R) was more enriched than predicted from temperature-dependent H(2)O-CO(2) equilibration theory, similar to other recent observations of delta(18)O(R) from dry soils (Wingate L, Seibt U, Maseyk K, Ogee J, Almeida P, Yakir D, Pereira JS, Mencuccini M. Global Change Biol. 2008; 14: 2178). The soil chamber coupled with the TDL was found to be an effective method for capturing soil CO(2) efflux and its stable isotope composition at high temporal frequency.

59 BASIC BIOLOGICAL SCIENCES↗

Upscaling of Bio-mediated Soil Improvement

As demand for soil improvement continues to increase, new, sustainable, and innocuous methods are needed to alter the mechanical properties of soils. Recent research has demonstrated the potential of bio-mediated soil improvement for geotechnical applications (DeJong et al. 2006, Whiffin et al. 2007). Upscaling the bio-mediated treatment process for in situ implementation presents a number of challenges to be addressed, including soil and pore fluid interactions, bioaugmentation versus biostimulation of microbial communities, controlled distribution of mediated calcite precipitation, and permanence of the cementation. Current studies are utilizing large-scale laboratory experiments, non-destructive geophysical measurements, and modeling, to develop an optimized and predictable bio-mediated treatment method.

54 ENVIRONMENTAL SCIENCES↗

Apparatus and method for inspecting a sealed container

An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

47 OTHER INSTRUMENTATION↗

Carbonate Thermochemical Cycle for the Production of Hydrogen

The present invention is directed to a thermochemical method for the production of hydrogen from water. The method includes reacting a multi-valent metal oxide, water and a carbonate to produce an alkali metal-multi-valent metal oxide compound, carbon dioxide, and hydrogen.

08 HYDROGEN↗

HPC top 10 InfiniBand Machine : a 3D Torus IB interconnect on Red Sky.

This presentation discusses the following topics: (1) Red Sky Background; (2) 3D Torus Interconnect Concepts; (3) Difficulties of Torus in IB; (4) New Routing Code for IB a 3D Torus; (5) Red Sky 3D Torus Implementation; and (6) Managing a Large IB Machine. Computing at Sandia: (1) Capability Computing - Designed for scaling of single large runs, Usually proprietary for maximum performance, and Red Storm is Sandia's current capability machine; (2) Capacity Computing - Computing for the masses, 100s of jobs and 100s of users, Extreme reliability required, Flexibility for changing workload, Thunderbird will be decommissioned this quarter, Red Sky is our future capacity computing platform, and Red Mesa machine for National Renewable Energy Lab. Red Sky main themes are: (1) Cheaper - 5X capacity of Tbird at 2/3 the cost, Substantially cheaper per flop than our last large capacity machine purchase; (2) Leaner - Lower operational costs, Three security environments via modular fabric, Expandable, upgradeable, extensible, and Designed for 6yr. life cycle; and (3) Greener - 15% less power-1/6th power per flop, 40% less water-5M gallons saved annually, 10X better cooling efficiency, and 4x denser footprint.

99 GENERAL AND MISCELLANEOUS↗

Advanced Head End for the Treatment of Used LWR Fuel

A novel dry head-end process is being developed. The main goals are the separation of cladding from fuel and the upfront removal of problematic fission products while facilitating the downstream processing. Cold tests using surrogate pellets and tests on a scale of tens of milligrams using actual used fuel are very promising. The initial tests showed that the process can be performed at significantly lower temperatures than those for standard voloxidation by using a mixture of NO{sub 2}/O{sub 2} or NO{sub 2}/O{sub 3} to produce a fine red powder of UO{sub 3} and to release all the tritium and iodine. This powder - containing the uranium as UO{sub 3}, transuranium actinides, and nonvolatile fission product oxides - is readily soluble in dilute acids. Alternatively, the tests showed that the UO{sub 3} powder can be contacted with NO{sub 2}(N{sub 2}O{sub 4}) gas or liquid at room temperature to produce metal nitrates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗