Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Direct in-situ observation of early age void evolution in sustainable cement paste containing fly ash or limestone

This paper uses fast X-ray Computed Tomography (fCT) to study the change in air-filled voids during hydration of portland cement pastes of different water to cement ratios and with fly ash and limestone additives between 30 min and 12 h of hydration with deionized and de-aired water. For the deionized samples, the total volume of the air-filled voids increased during the induction period and decreased as the acceleration period began and finally stayed constant. The samples with 20% replacement of fly ash and 20% replacement of limestone showed the same trends as the OPC samples but with a reduction in the observed air-filled void formation. The air-filled void distribution in these samples changed from a limited number of large voids at the beginning of the measurements to a system with a significantly greater number of uniformly distributed smaller voids. The changes in the air-filled voids were not significant in pastes made with 50% fly ash or with de-aired water in the same testing condition. This might be explained by differences in pore solution chemistry and a reduced amount of dissolved air in the mixing water. A mechanism is proposed for a change in ionic concentration in solution to cause release of the dissolved air within the mixing water.

Cement hydration↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Reprogramming of somatic cells induced by fusion of embryonic stem cells using hemagglutinating virus of Japan envelope (HVJ-E)

In this research, hemagglutinating virus of Japan envelope (HVJ-E) was used to reprogram somatic cells by fusion with mouse embryonic stem (ES) cells. Neomycin-resistant mouse embryonic fibroblasts (MEFs) were used as somatic cells. Nanog-overexpressing puromycin-resistant EB3 cells were used as mouse ES cells. These two cells were fused by exposing to HVJ-E and the generated fusion cells were selected by puromycin and G418 to get the stable fusion cell line. The fusion cells form colonies in feeder-free culture system. Microsatellite analysis of the fusion cells showed that they possessed genes from both ES cells and fibroblasts. The fusion cells were tetraploid, had alkali phosphatase activity, and expressed stem cell marker genes such as Pou5f1, Nanog, and Sox2, but not the fibroblast cell marker genes such as Col1a1 and Col1a2. The pluripotency of fusion cells was confirmed by their expression of marker genes for all the three germ layers after differentiation induction, and by their ability to form teratoma which contained all the three primary layers. Our results show that HVJ-E can be used as a fusion reagent for reprogramming of somatic cells.

60 APPLIED LIFE SCIENCES↗

The influence of ns- and fs-LA plume local conditions on the performance of a combined LIBS/LA-ICP-MS sensor

Both laser-induced breakdown spectroscopy (LIBS) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are well-established analytical techniques with their own unique advantages and disadvantages. The combination of the two analytical methods is a very promising way to overcome the challenges faced by each method individually. We made a comprehensive comparison of local plasma conditions between nanosecond (ns) and femtosecond (fs) laser ablation (LA) sources in a combined LIBS and LA-ICP-MS system. The optical emission spectra and ICP-MS signal were recorded simultaneously for both ns- and fs-LA and figures of merit of the system were analyzed. Characterization of the plasma was conducted by evaluating temperature and density of the plume under various irradiation conditions using optical emission spectroscopy, and correlations to ns- and fs-LIBS and LA-ICP-MS signal were made. The present study is very useful for providing conditions for a multimodal system as well as giving insight into how laser ablation plume parameters are related to LA-ICP-MS and LIBS results for both ns- and fs-LA.

LaHaye, Nicole L.↗

Low Dose Radiation-Induced Epigenetic Changes in an Animal Model (Final Report)

This project sought mechanistic understanding of the epigenetic response of tissues as well as the consequences of those responses, when induced by low dose irradiation in a well-established model system (mouse). Based on solid and extensive preliminary data we investigated the molecular epigenetic mechanisms of in vivo radiation responses, particularly – effects of low, occupationally relevant radiation exposures on the genome stability and adaptive response in mammalian tissues and organisms. We accumulated evidence that low dose irradiation altered epigenetic profiles and impacted radiation target organs of the exposed animals. The main long-term goal was to dissect the epigenetic basis of induction of the low dose radiation-induced genome instability and adaptive response and the specific fundamental roles of epigenetic changes (i.e. DNA methylation, histone modifications and miRNAs) in their generation. We hypothesized that changes in global and regional DNA methylation, global histone modifications and regulatory microRNAs played pivotal roles in the generation and maintenance low-dose radiation-induced genome instability and adaptive response. We predicted that epigenetic changes influenced the levels of genetic rearrangements (transposone reactivation). We hypothesized that epigenetic responses from low dose irradiation were dependent on exposure regimes, and would be greatest when organisms are exposed in a protracted/fractionated manner: fractionated exposures > acute exposures. We anticipated that the epigenetic responses were correlated with the gene expression levels. Our immediate objectives were: • To investigate the exact nature of the global and locus-specific DNA methylation changes in the LDR exposed cells and tissues and dissect their roles in adaptive response • To investigate the roles of histone modifications in the low dose radiation effects and adaptive response • To dissect the roles of regulatory microRNAs and their targets in low dose radiation effects and adaptive response • To correlate the levels of epigenetic changes with genetic rearrangement levels and gene expression patterns. In sum, we determined the precise global and locus-specific DNA methylation patterns in the LDR-exposed cells and tissues of mice, and to correlated DNA methylation changes with the gene expression patterns and manifestations of genome instability. We also determined the alterations of global histone modification pattern in the LDR exposed tissues. Additionally, we established the nature of microRNAome changes in the LDR exposed tissue. In this study we for the first time found that LDR exposure caused profound tissue-specific epigenetic changes in the exposed tissues. We established that LDR exposure affect methylation of repetitive elements in the murine genome, causes changes in histone methylation, acetylation and phosphorylation. Importantly, we found that LDR causes profound and persistent effects on small RNA profiles and gene expression, and that miRNAs are excellent biomarkers of LDR exposure. Furthermore, we extended our analysis and studied LDR effects in rat tissues and human tissues and cell lines. There we also analyzed LDR-induced gene expression, DNA methylation and miRNA changes. Our datasets laid foundation for several new research projects aimed to understand molecular underpinnings of low dose radiation responses, and biological repercussions of low dose radiation effects and radiation carcinogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

An Investigation into the Effects of Swirl on the Performance and Emissions of an Opposed-Piston Two-Stroke Engine using Large Eddy Simulations

Opposed-piston two-stroke (OP-2S) engines have the potential to achieve higher thermal efficiency than a conventional four-stroke diesel engine. However, the uniflow scavenging process is difficult to control over a wider range of speed and loads due to its sensitivity to pressure dynamics, port timings, and port design. Specifically, the angle of the intake ports can be used to generate swirl which has implications for open and closed cycle effects. This study proposes an analysis of the effects of port angle on the in-cylinder flow distribution and combustion performance of an OP-2S using computational fluid dynamics engine. Large Eddy Simulation (LES) was used to model turbulence given its ability to predict in-cylinder mixing and cyclic variability. A three-cylinder model was validated to experimental data collected by Achates Power and the grid was verified using an LES quality approach from the literature. The model was used to simulate port angles from 12 to 29 degrees at constant pressure and temperature boundary conditions. Results indicated that the higher bulk swirl ratio generated by larger port angles tends to trap more internal residuals. This effect on the scavenging performance, combined with the larger trapped swirl ratio, also has a significant impact on the combustion performance in a two-stroke engine. It was concluded that there exists a tradeoff of efficiency and emissions that must be considered when increasing the port angle in a uniflow two-stroke engine. 1. Introduction Two-stroke engines were developed in the 1800s and are commonly used in practice today for lightweight power applications such as motorcycles or handheld power tools, as well as large-bore low speed engines for stationary power and marine applications. Two-stroke engines provide the distinct advantage of higher torque/power output but present challenges due to its coupled intake and exhaust process. Four-stroke engines have the benefit of using two full piston strokes to induct intake charge and to expel exhaust gases. Controlling the trapped charge composition in a twostroke engine via a scavenging process is crucial for reliable and efficient engine operation.

33 ADVANCED PROPULSION SYSTEMS↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring stages of resilience maturity as communities confront climate risks

Coastal communities are facing increased risks due to climate change, as evidenced by heightened shocks such as hurricanes and wildfires, and stressors including sea-level rise and drought. To confront these risks, many coastal communities are planning and designing their built environments in new ways, with the overall goal of increasing their resilience. However, resilience practices have been widely guided by an event-based timeframe, which may not be sufficient to confront the multiple and overlapping threats expected over the coming decades. To address this concern, this study investigated a long-term perspective on resilience progression, termed resilience maturity. To better understand resilience maturity in practice, this study drew directly on community perspectives, thereby identifying common challenges. Furthermore, variation in resilience maturity across communities provided an opportunity to identify existing successful strategies. Inductive qualitative analysis was used to examine perspectives from 15 interviews with local practitioners across 12 coastal communities. The analysis revealed that communities in early stages of resilience maturity often struggle with local stakeholder alignment and minimal dedicated resilience resources. In contrast, those further along the maturity path often face technology barriers and challenges in aligning regional stakeholders. Few examples of a fully mature resilience culture were found within the communities studied, underscoring systemic barriers to achieving advanced resilience maturity. Overall, these findings supported development of a practical framework for classifying community resilience efforts, identifying common obstacles, and informing localized resilience advancement.

Resilience maturity↗

Optical emission spectroscopy and imaging of low-pressure N2 plasmas generated by intense fast-pulsed electron beams

An optical emission spectroscopic (OES) and imaging characterization is conducted on N2 plasmas generated by a 100 keV fast-pulsed electron beam. The electron beams are injected into an N2 gas filled volume with a current of 4.5 kA (300 A/cm2) and a 100 ns pulse width. The characterization is conducted at the pressures, 1 Torr and 0.1 Torr, corresponding to two distinct regimes that exhibit significantly different plasma dynamics. Beam impact ionization is shown to be a primary mechanism for producing low temperature plasmas at 1 Torr during beam output. After beam termination, ionization by an inductive electric field becomes the primary mechanism for plasma formation later in time for both pressures. OES and plasma imaging are used in this work as a diagnostic tool to track the distribution of electronic, vibrational, and rotational state transitions and ionized species. This is achieved with the use of a multi-resolution suite of spectrometers capable of acquiring time-resolved spectra. Vibrational and rotational bands of the N2 second positive system (C3Πu→B3Πg) and the N2+ first negative system (B2Σu+→X2Σg+) are identified in both regimes as well as N+ states exclusively in the lower pressure regime. Vibrational and rotational spectra are shown to track the evolution of the time-varying plasma current. Plasma imaging also reveals spatially nonuniform plasma emission at 0.1 Torr. A few hundred shots are recorded to fully characterize the emissions, and results are shown to be highly reproducible (≤±1% with 2σ confidence).

Kaiser, E. R. (ORCID:0000000336493938)↗

Implications of NSTX Lithium Results for Magnetic Fusion Research

Lithium wall coating techniques have been experimentally explored on NSTX for the last five years. The lithium experimentation on NSTX started with a few milligrams of lithium injected into the plasma as pellets and it has evolved to a lithium evaporation system which can evaporate up to ~ 100 g of lithium onto the lower divertor plates between lithium reloadings. The unique feature of the lithium research program on NSTX is that it can investigate the effects of lithium in H-mode divertor plasmas. This lithium evaporation system thus far has produced many intriguing and potentially important results; the latest of these are summarized in a companion paper by H. Kugel. In this paper, we suggest possible implications and applications of the NSTX lithium results on the magnetic fusion research which include electron and global energy confinement improvements, MHD stability enhancement at high beta, ELM control, H-mode power threshold reduction, improvements in radio frequency heating and non-inductive plasma start-up performance, innovative divertor solutions and improved operational efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chromatin Changes in Phytochrome Interacting Factor-Regulated Genes Parallel Their Rapid Transcriptional Response to Light

As sessile organisms, plants must adapt to a changing environment, sensing variations in resource availability and modifying their development in response. Light is one of the most important resources for plants, and its perception by sensory photoreceptors (e.g., phytochromes) and subsequent transduction into long-term transcriptional reprogramming have been well characterized. Chromatin changes have been shown to be involved in photomorphogenesis. However, the initial short-term transcriptional changes produced by light and what factors enable these rapid changes are not well studied. Here, we define rapidly light-responsive, Phytochrome Interacting Factor (PIF) direct-target genes (LRP-DTGs). We found that a majority of these genes also show rapid changes in Histone 3 Lysine-9 acetylation (H3K9ac) in response to the light signal. Detailed time-course analysis of transcript and chromatin changes showed that, for light-repressed genes, H3K9 deacetylation parallels light-triggered transcriptional repression, while for light-induced genes, H3K9 acetylation appeared to somewhat precede light-activated transcript accumulation. However, direct, real-time imaging of transcript elongation in the nucleus revealed that, in fact, transcriptional induction actually parallels H3K9 acetylation. Collectively, the data raise the possibility that light-induced transcriptional and chromatin-remodeling processes are mechanistically intertwined. Histone modifying proteins involved in long term light responses do not seem to have a role in this fast response, indicating that different factors might act at different stages of the light response. This work not only advances our understanding of plant responses to light, but also unveils a system in which rapid chromatin changes in reaction to an external signal can be studied under natural conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Development of In-Can Melting Process Applied to Vitrification of High Activity Waste Solutions (HAWS): Glass characterizations and process tests results - 12442

The CEA has selected vitrification for specific High-Activity nuclear Waste Solutions (HAWS) containing large quantities of salts. This choice has led the CEA Marcoule to develop a compact 'in-can' batch melting process in which the melting pot is disposable and serves as the primary canister for the solidified glass. This process is particularly suitable for the treatment of small waste quantities (less than 10 m{sup 3} per year) and low flow rates (5 to 10 L/h) which do not justify the use of a Cold Crucible Induction Melter. The unit capacity is approximately one hundred kilograms of glass a week operating alternately between feeding during the day and surveillance at night. In order to be fully representative of the glove box to be implemented, a new nonradioactive pilot-scale unit in which the core process (furnace and dust scrubber) is completely enclosed with glove box simulation was built at CEA Marcoule in 2008. The equipment includes all the systems and components necessary to perform full-scale tests: feed system, furnace and complete off-gas treatment system. The nominal tests were performed in 2009 and 2010 to verify that no problems arose in vitrifying solutions under the specified conditions. Two different liquid feeds representatives of the current HAWS stored and future solutions were used. The transient runs were carried out in this facility in 2010. Their objectives were to validate the glass product with different operating conditions and to determine optimum parameters for transient phases such as decreased volatility during standby phases. Finally, all the material obtained under nominal conditions or different operating conditions (e.g. initial glass frit quantity, standby temperature or restart procedure of feeding after night surveillance) have been characterized and described. The impact of transient phases on the process is then discussed in terms of volatility, thermal balance, etc., and compared with nominal tests results. Off-gas treatment system (OGTS) assessments determined preliminary decontamination factors for the OGTS components and allowed comparison between the two types of solutions and for different operating parameters. Since 2005 CEA Marcoule has been developing an 'in-can melting' vitrification process for specific High Activity Nuclear Waste Solutions. The tests carried out to date have validated the feasibility of this process and confirmed the direct vitrification option in which the liquid and solid feed streams are supplied directly to a disposable melting pot. CEA Marcoule began process qualification testing in 2009 in a new facility using equipment representative of the devices that will be installed in a glove box. The nominal mode tests performed in 2009 and 2010 were used to determine nominal operating conditions for the process: - a nominal process temperature of 1100 deg. C; - a maximum glass production rate of 5 kg/h; - a liquid feed solution flow rate of 5 L/h or less if the glass production rate exceeds the preceding maximum value; - a liquid recycle rate of 0.5 L/h for a nominal solution feed rate 5 L/h. They also produced glass samples generally meeting our expectations, and allowed us to measure the characteristic properties (viscosity, density, thermal conductivity, chemical durability). The first test of transient operation in 2010 yielded glass consistent with expectations and showed that reducing the temperature had no significant effect on the volatility of the constituent elements. However, a significant impact on the release of elements at the beginning of the test was observed with a larger initial quantity of glass frit on startup. The process qualification program will now continue with tests of degraded operating modes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗