Beam-assisted large elongation of in situ formed Li2O nanowires

As an important component of the solid electrolyte interface in lithium ion batteries and an effective blanket breeding material in fusion reactor, the mechanical property of Li2O is of great interest but is not well understood. Here we show that the polycrystalline Li2O nanowires were formed in situ by touching and pulling lithium hydroxide under electron beam (e-beam) illumination. The Li2O nanowires sustained an enhanced elongation (from 80% to 176%) under low dose e-beam irradiation near room temperature as compared with that (from 51% to 57%) without e-beam irradiation. The extremely high deformability could be understood by the fast Li2O diffusion under e-beam irradiation and tensile stress condition. The large elongation without e-beam irradiation implies that nano-structured Li2O is ductile near room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Fine-Adjustment Thruster For Space Vehicles

To the present time, a few laser propulsion engine devices have been developed by using dominant mechanisms of laser propulsion. Generally these mechanisms are laser ablation, laser breakdown of gases, and laser detonation waves that are induced due to extraction of the internal energy of polymer propellants. In the paper, we consider the Aero-Space Laser Propulsion Engine (ASLPE) developed earlier, in which all of these mechanisms are realized via interaction of laser radiation with polymers both in continuous wave (CW) and in repetitively pulsed modes of laser operation. The ASLPE is considered to be exploited as a unit of a laser propulsion device being arranged onboard space vehicles moving around the Earth or in interplanetary missions and intended to correct the vehicles orbits. To produce a thrust, a power of the solar pumped lasers designed to the present time is considered in the paper. The problem of increasing the efficiency of the laser propulsion device is analyzed as applied to space missions of vehicles by optimizing the laser propulsion propellant composition.

42 ENGINEERING↗

Unipolar resistive switching behavior of amorphous YCrO{sub 3} films for nonvolatile memory applications

Amorphous YCrO{sub 3} (YCO) films were prepared on Pt/TiO{sub 2}/SiO{sub 2}/Si substrate by pulsed laser deposition in order to investigate resistive switching (RS) phenomenon. The Pt/YCO/Pt device showed stable unipolar RS with resistance ratio of ∼10{sup 5} between low and high resistance states, excellent endurance and retention characteristics, as well as, non-overlapping switching voltages with narrow dispersions. Based on the x-ray photoelectron spectroscopy and temperature dependent switching characteristics, observed RS was mainly ascribed to the oxygen vacancies. Moreover, current-voltage characteristics of the device in low and high resistance states were described by Ohmic and trap controlled space–charge limited conduction mechanisms, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Growth and microstructure of columnar Y-doped SrZrO{sub 3} films deposited on Pt-coated MgO by pulsed laser deposition

Direct integration of proton conductor films on Pt-coated substrates opens the way to film-based proton transport devices. Columnar SrZr{sub 0.95}Y{sub 0.05}O{sub 3−δ} (SZY) films with dense microstructure were deposited on Pt-coated MgO(100) substrates at 830 °C by pulsed laser deposition. The optimal window of ambient O{sub 2} pressure for good crystallinity of SZY films is from 400 to 600 mTorr. The ambient O{sub 2} compresses the plasma plume of SZY and increases the deposition rate. The 10 nm thick Ti adhesion layer on MgO(100) greatly affects the orientation of the sputtered Pt layers. Pt deposited directly on MgO shows a highly (111)-preferred orientation and leads to preferentially oriented SZY films while the addition of a Ti adhesion layer makes Pt show a less preferential orientation that leads to randomly oriented SZY films. The RMS surface roughness of preferentially oriented SZY films is larger than that of randomly oriented SZY films deposited under the same ambient O{sub 2} pressure. As the O{sub 2} pressure increased, the RMS surface roughness of preferentially oriented SZY films increased, reaching 45.7 nm (2.61% of film thickness) at 600 mTorr. This study revealed the ambient O{sub 2} pressure and orientation dependent surface roughness of SZY films grown on Pt-coated MgO substrates, which provides the potential to control the surface microstructure of SZY films for electrochemical applications in film-based hydrogen devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical solutions to reduce mediastinal irradiation in young patients undergoing treatment for lymphomas: Preliminary experience

This study aims at optimizing treatment planning in young patients affected by lymphoma (Stage II to III) by using an inclined board (IB) that allows reducing doses to the organs at risk. We evaluated 19 young patients affected by stage I to III lymphomas, referred to our Department for consolidation radiotherapy (RT) treatment on the mediastinum. Patients underwent 2 planning computed tomography (CT) scans performed in different positions: flat standard position and inclined position. A direct comparison between the different treatment plans was carried out analyzing dosimetric parameters obtained from dose-volume histograms generated for each plan. Comparison was performed to evaluate the sparing obtained on breast and heart. Dosimetric evaluation was performed for the following organs at risk (OARs): mammary glands, lungs, and heart. A statistically significant advantage was reported for V{sub 5}, V{sub 20}, and V{sub 30} for the breast when using the inclined board. A similar result was obtained for V{sub 5} and V{sub 10} on the heart. No advantage was observed in lung doses. The use of a simple device, such as an inclined board, allows the optimization of treatment plan, especially in young female patients, by ensuring a significant reduction of the dose delivered to breast and heart.

61 RADIATION PROTECTION AND DOSIMETRY↗

An impedance-based diameter gauge for in-pile fuel deformation measurements

During irradiation, the fuel-cladding interface of a nuclear fuel rod can experience significant mechanical and chemical interaction. In-situ measurement of the radial deformation of the cladding can quantify the extent of this interaction and the state of the cladding. Existing capabilities to perform in-pile diameter measurements are limited by required contact and an intrusive presence of a device near to a specimen. To overcome these limitations, researchers have developed and evaluated an electrical impedance based diameter gauge using a benchtop system. The sensor consists of an electrically conductive concentric ring around the fuel cladding such that the electrical impedance between the ring and cladding is measured. Additionally, the cladding diameter is determined through a measurement of the electrical impedance between the electrodes with a known ring electrode diameter. Analytic and 3-D finite element analyses (FEA) were used to quantify the measurement sensitivity, uncertainty, and off-design conditions. The experimental sensor measured diameters with <20 µm of error, and had a measurement resolution of <1 µm for diameters ranging from 9.5 to 9.6 mm. Lastly, the uncertainty analysis for the experimental setup estimated an uncertainty of 20 µm, consistent with the experimentally measured results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Solar‐Thermal Distillation Desalination Device by Light Absorptive Carbon Composite Porous Foam

Abstract Solar‐thermal driven desalination based on porous carbon materials has promise for fresh water production. Exploration of high‐efficiency solar desalination devices has not solved issues for practical application, namely complicated fabrication, cost‐effectiveness, and scalability. Here, direct solar‐thermal carbon distillation (DS‐CD) tubular devices are introduced that have a facile fabrication process, are scalable, and use an inexpensive but efficient microporous graphite foam coated with carbon nanoparticle and superhydrophobic materials. The “black” composite foam serving as a solar light absorber heats up salt water effectively to produce fresh water vapor, and the superhydrophobic surface of the foam traps the liquid feed in the device. Two proof‐of‐principle distillation systems are adopted, i.e., solar still and membrane distillation and the fabricated devices are evaluated for direct solar desalination efficiency. For the solar still, nanoparticle and fluorosilane coatings on the porous surface increase the solar energy absorbance, resulting in a solar‐steam generation efficiency of 64% from simulated seawater at 1 sun. The membrane distillation demonstrates excellent vapor production (≈6.6 kg m ‐2 h ‐1 ) with >99.5% salt rejection under simulated 3 sun solar‐thermal irradiation. Unlike traditional solar desalination, the adaptable DS‐CD can easily be scaled up to larger systems such as high‐temperature tubular modules, presenting a promising solution for solar‐energy‐driven desalination.

42 ENGINEERING↗

Pulsed laser deposition of high-quality thin films of the insulating ferromagnet EuS

High-quality thin films of the ferromagnetic insulator europium(II) sulfide (EuS) were fabricated by pulsed laser deposition on Al{sub 2}O{sub 3} (0001) and Si (100) substrates. A single orientation was obtained with the [100] planes parallel to the substrates, with atomic-scale smoothness indicates a near-ideal surface topography. The films exhibit uniform ferromagnetism below 15.9 K, with a substantial component of the magnetization perpendicular to the plane of the films. Optimization of the growth condition also yielded truly insulating films with immeasurably large resistance. This combination of magnetic and electric properties opens the gate for future devices that require a true ferromagnetic insulator.

36 MATERIALS SCIENCE↗

Electric field dependence of junction magnetoresistance in magnetite/semiconductor heterostructure at room temperature

We have fabricated Fe{sub 3}O{sub 4}/p-Si heterojunction using pulsed laser deposition technique and explored its electro-magnetic transport properties. The heterojunction exhibits backward rectifying property at all temperatures, and appraisal of giant junction magnetoresistance (JMR) is observed at room temperature (RT). Conspicuously, the variation and sign change of JMR as a function of electric field is observed at RT. The backward rectifying behavior of the device is ascribed to the highly doped p-type (p{sup ++}) semiconducting nature of Fe{sub 3}O{sub 4}, and the origin of electric field (voltage) dependence of magnetoresistance is explained proposing electronic band diagram of Fe{sub 3}O{sub 4}/SiO{sub 2}/p-Si heterojunction. This interesting result may have importance to integrate Si-based magnetoresistance sources in multifunctional spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An easy method to account for light scattering dose dependence in radiochromic films

Purpose: To date no detector can offer the unbeatable characteristics of film dosimetry in terms of spatial resolution and this is why it has been chosen by many institutions for treatment verification and, in that respect, radiochromic films are becoming increasingly popular due to their advantageous properties. It is the aim of this work to suggest an easy method to overcome one of the drawbacks in radiochromic film dosimetry associated with the scanning device, namely, the non-uniform dose dependent response, mainly due to the light scattering effect. Methods: The suggested procedure consists of building four correction matrices by sequentially scanning one, two, three, and four unexposed blank films. The color level of these four matrices is compatible with four points in the calibration curve dose range. Therefore, the dose dependent correction to the scanned irradiated film will be obtained by interpolating between the four correction matrices. Results: The validity of the suggested method is checked against an ion chamber 2D array. The use of the proposed flattening correction improves considerably the dose agreement when compared with the cases in which no correction is applied. Conclusions: The method showed to be fast and easy and practically overcomes the dependence on the dose of light scattering of flatbed scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-D-BRA-03: Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device

Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLC closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.

60 APPLIED LIFE SCIENCES↗

Single event upset vulnerability of selected 4K and 16K CMOS static RAM's

Upset thresholds for bulk CMOS and CMOS/SOS RAMS were deduced after bombardment of the devices with 140 MeV Kr, 160 MeV Ar, and 33 MeV O beams in a cyclotron. The trials were performed to test prototype devices intended for space applications, to relate feature size to the critical upset charge, and to check the validity of computer simulation models. The tests were run on 4 and 1 K memory cells with 6 transistors, in either hardened or unhardened configurations. The upset cross sections were calculated to determine the critical charge for upset from the soft errors observed in the irradiated cells. Computer simulations of the critical charge were found to deviate from the experimentally observed variation of the critical charge as the square of the feature size. Modeled values of series resistors decoupling the inverter pairs of memory cells showed that above some minimum resistance value a small increase in resistance produces a large increase in the critical charge, which the experimental data showed to be of questionable validity unless the value is made dependent on the maximum allowed read-write time.

Kolasinski, W. A.↗

Accelerated Partial Breast Irradiation: What is Dosimetric Effect of Advanced Technology Approaches?

Purpose: The present treatment planning study compared whole breast radiotherapy (WBRT) to accelerated partial breast irradiation (APBI) for different external beam techniques and geometries (e.g., free breathing [FB] and deep inspiration breath hold [DIBH]). Methods and Materials: After approval by our institutional review board, a treatment planning study was performed of 10 patients with left-sided Stage 0-I breast cancer enrolled in a Phase I-II study of APBI using intensity-modulated radiotherapy (IMRT). After lumpectomy, patients underwent planning computed tomography scans during FB and using an active breathing control device at DIBH. For the FB geometry, standard WBRT and three-dimensional conformal radiotherapy (3D-CRT) APBI plans were created. For the DIBH geometry with active breathing control, WBRT, 3D-CRT, and IMRT APBI plans were created. Results: All APBI techniques had excellent planning target volume coverage. The maximal planning target volume dose was reduced from 116% of the prescription dose to 108% with the IMRT(DIBH) APBI plan. The maximal heart dose was >30 Gy for the WBRT techniques, 8.2 Gy for 3D-CRT(FB), and <5.0 Gy for 3D-CRT(DIBH) and IMRT(DIBH) techniques. The mean left anterior descending artery dose was significantly reduced from 11.4 Gy with WBRT(FB) to 4.2 with WBRT(DIBH) and <2.0 Gy with all APBI techniques. Conclusion: Although planning target volume coverage was acceptable with all techniques, the plans using the DIBH geometry resulted in a marked reduction in the normal tissue dose compared with WBRT planned in the absence of cardiac blocking. Additional study is needed to determine whether these techniques result in clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

Note: A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic lattice-matched 0.74 eV InGaAs thermophotovoltaic (TPV) power converter under 980 C blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 cm(exp 2) chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. The power efficiency of this TPV device is 16% for that part of the blackbody spectrum above the material bandgap. The device is shown to deliver about 1 watt of output power when driven with enough light. This is the first report of such a multijunction TPV device. This is not a traditional tandem cell in which the junctions are stacked vertically. Eight 1 mm long by 1 cm wide junctions are laterally connected across the device area. This multijunction design has the potential for lower I(exp 2)R power loss since the smaller PN junction area limits the current to one eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(exp 2)R loss, analogous to the way power utilities avoid I(exp 2)R loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

Displacement Damage Induced Dark Current and Random Telegraph Signal in P-Type Deep-Trench Pinned Photogates

This study focuses on displacement damage induced dark current and Random Telegraph Signal (RTS) in STMicroelectronics P-Type photogate, a device moving away from the 4T Pinned-Photodiode, with a sensitive volume exclusively made of boron-doped P-type epitaxy, and collecting holes instead of electrons. Results show a typical trend for the shape of dark current and RTS degradation in CMOS Image Sensors with the exception that the measured generation rates seem 2 times smaller than typical literature values in irradiated silicon. Different hypothesis on the origin of this discrepancy are explored.

displacement damage dose↗

SU-F-T-520: Dosimetric Comparison of Radiation Treatment Plans for Whole Breast Irradiation Between 3D Conformal in Prone and Supine Positions Vs. VMAT and IMRT in Supine Positions

Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boards and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.