At least 1,243 records · Page 69

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. IV. OBSERVATIONS OF KEPLER, CoRoT, AND HIPPARCOS STARS FROM THE GEMINI NORTH TELESCOPE

We present the results of 71 speckle observations of binary and unresolved stars, most of which were observed with the DSSI speckle camera at the Gemini North Telescope in 2012 July. The main purpose of the run was to obtain diffraction-limited images of high-priority targets for the Kepler and CoRoT missions, but in addition, we observed a number of close binary stars where the resolution limit of Gemini was used to better determine orbital parameters and/or confirm results obtained at or below the diffraction limit of smaller telescopes. Five new binaries and one triple system were discovered, and first orbits are calculated for other two systems. Several systems are discussed in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Subaru SCExAO First-Light Direct Imaging of a Young Debris Disk around HD 36546

We present H-band scattered light imaging of a bright debris disk around the A0 star HD 36546 obtained from the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system with data recorded by the HiCIAO camera using the vector vortex coronagraph. SCExAO traces the disk from r approximately 0 3 to r approximately 0".3 to r approximately 1" (34-114 au). The disk is oriented in a near east west direction (PA approximately 75deg), is inclined by I approximately 70deg-75deg, and is strongly forward-scattering(g greater than 0.5). It is an extended disk rather than a sharp ring; a second, diffuse dust population extends from the disks eastern side. While HD 36546 intrinsic properties are consistent with a wide age range (t approximately 1-250 Myr), its kinematics and analysis of coeval stars suggest a young age (310 Myr) and a possible connection to Taurus-Aurigas star formation history. SCExAOs planet-to-star contrast ratios are comparable to the first-light Gemini Planet Imager contrasts; for an age of 10 Myr, we rule out planets with masses comparable to HR 8799 b beyond a projected separation of 23 au. A massive icy planetesimal disk or an unseen super-Jovian planet at r greater than 20 au may explain the disks visibility. The HD 36546 debris disk may be the youngest debris disk yet imaged, is the first newly identified object from the now-operational SCExAO extreme AO system, is ideally suited for spectroscopic follow-up with SCExAO/CHARIS in 2017, and may be a key probe of icy planet formation and planet disk interactions.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗

Ground-Based Vision Tracker for Advanced Air Mobility and Urban Air Mobility

Advanced Air Mobility (AAM) Air Mobility and Urban Air Mobility (UAM) require aircraft surveillance and monitoring for safety and security. Persistent tracking of flying objects provides Air Traffic Control (ATC) and Air Traffic Management (ATM) continuous coverage and knowledge of the national airspace system (NAS). Given the significant disparity in the number of AAM and UAM aircraft compared to commercial aircraft in the NAS, coupled with the dense AAM/UAM operations in urban environments, employing the existing ATC/ATM architectures poses considerable challenges. A first step in creating a similar ATC/ATM architecture for AAM/UAM will require ground-based and airborne-based sensors to provide monitoring, which will be difficult in urban environments due to GPS degradation. This paper proposes a vision-based tracking method with static cameras by utilizing image subtraction and blob detection, which avoids adding additional electromagnetic interferences in the environment with sensors such as radar. The ground-based vision tracker (GBVT) outputs the detected objects' azimuth and elevation angles from unmanned aerial system (UAS) flight tests. Future and ongoing work includes sending the detected objects' azimuth and elevation angles as inputs for an extended Kalman filter (EKF) to estimate the position and velocity of the detected object.

distributed sensing↗

Integral image tube-optical systems for the far UV.

Description of proposed image tube optical systems for narrow-band direct photography and broad bandpass photography from spacecraft outside the atmosphere. For narrow-band photography an f/1.5 Schmidt camera with a photocathode located on the focal surface is recommended. The photoelectrons are accelerated and magnetically focused onto a phosphor/fiber optics surface, the curvature of which partially corrects for distortions of the electric field introduced by the curved photocathode. The second stage can be any other tube, electrostatically or magnetically focused, having a fiber optics faceplate butted to the first stage. For broad bandpass a spectrograph with an f/3 all-reflecting Schmidt image tube camera is recommended.

Chincarini, G.↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of a simultaneous dual-isotope {sup 201}Tl/{sup 123}I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Background: Dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Methods: Sixty-nine patients were prospectively enrolled after revascularization to undergo {sup 201}Tl/{sup 123}I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Results: Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Conclusions: Delayed acquisitions and scatter-corrected dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mars Science Laboratory Engineering Cameras

NASA's Mars Science Laboratory (MSL) Rover, which launched to Mars in 2011, is equipped with a set of 12 engineering cameras. These cameras are build-to-print copies of the Mars Exploration Rover (MER) cameras, which were sent to Mars in 2003. The engineering cameras weigh less than 300 grams each and use less than 3 W of power. Images returned from the engineering cameras are used to navigate the rover on the Martian surface, deploy the rover robotic arm, and ingest samples into the rover sample processing system. The navigation cameras (Navcams) are mounted to a pan/tilt mast and have a 45-degree square field of view (FOV) with a pixel scale of 0.82 mrad/pixel. The hazard avoidance cameras (Haz - cams) are body-mounted to the rover chassis in the front and rear of the vehicle and have a 124-degree square FOV with a pixel scale of 2.1 mrad/pixel. All of the cameras utilize a frame-transfer CCD (charge-coupled device) with a 1024x1024 imaging region and red/near IR bandpass filters centered at 650 nm. The MSL engineering cameras are grouped into two sets of six: one set of cameras is connected to rover computer A and the other set is connected to rover computer B. The MSL rover carries 8 Hazcams and 4 Navcams.

Maki, Justin N.↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Smart Camera Technology Increases Quality

When it comes to real-time image processing, everyone is an expert. People begin processing images at birth and rapidly learn to control their responses through the real-time processing of the human visual system. The human eye captures an enormous amount of information in the form of light images. In order to keep the brain from becoming overloaded with all the data, portions of an image are processed at a higher resolution than others, such as a traffic light changing colors. changing colors. In the same manner, image processing products strive to extract the information stored in light in the most efficient way possible. Digital cameras available today capture millions of pixels worth of information from incident light. However, at frame rates more than a few per second, existing digital interfaces are overwhelmed. All the user can do is store several frames to memory until that memory is full and then subsequent information is lost. New technology pairs existing digital interface technology with an off-the-shelf complementary metal oxide semiconductor (CMOS) imager to provide more than 500 frames per second of specialty image processing. The result is a cost-effective detection system unlike any other.

Source record↗

Integration and operation of a sUAS-based multi-modal imaging payload equipped with a novel communication system enabling autonomous platform control

Oak Ridge National Laboratory presents a new UAS-mounted multi-modal imaging payload containing five sensors. We have integrated several distinct commercially available sensors onto a large Class-1 autonomous quadcopter aircraft: a LIDAR (Light Detection and Ranging) scanner, a hyperspectral pushbroom sensor, a multispectral camera, a longwave infrared thermal camera, and an RGB camera. The system integrates our proprietary Multi-modal Autonomous Vehicle Network (MAVNet) and communication system, allowing autonomous control via multiple communication networks. Using one common Global Navigation Satellite System (GNSS) and inertial navigation system (INS/GPS), imagery from all sensors are accurately and precisely geolocated and co-registered.

Duncan, Andrew↗

Proposed Enhanced Imaging Station in the 6-GeV Booster-to-Storage Ring Transport Line for APS Upgrade

The high charge per micropulse of up to 17 nC in the booster to storage ring transport line (BTS) for APS Upgrade will necessitate changes in the imaging station used to evaluate beam emittance in this key region. The original Chromox screen has recently been replaced by a YAG:Ce single crystal for immediate screen spatial resolution improvement down to <10 µm. However, the optical system also needs an upgrade with lenses and a digital camera to take full advantage of this enhancement. In addition, at the high areal charge densities expected, the YAG:Ce scintillator mechanism will saturate, or quench, leading to images larger than the actual beam size. To circumvent this effect, optical transition radiation (OTR) screens will be implemented. A proposed longer-range goal of a non-intercepting beam-size monitor using optical diffraction radiation techniques during top-up injection will also be addressed.

43 PARTICLE ACCELERATORS↗

MISR Level 1B2 Ellipsoid Data (MI1B2E_V2)

The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The Ellipsoid product is referenced to the World Geodetic System 1984 (WGS84) ellipsoid, which approximates the Earth's shape at sea level. In this product, the radiances and associated altitudes are projected to the ellipsoid, so that higher elevation data appear displaced from their true location for non-nadir camera views, much as they are seen by the instrument. (A cloud at location F, or a mountain top at location T in the image below appears as if it is at location E.) The more oblique the camera view, or the higher in altitude the feature, the more displaced the elevated data will appear. This displacement is used to advantage in MISR stereo retrievals, and this product is the primary input to Level 2 top-of-atmosphere/cloud processing. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=563.2 km (cross-track); Longitude_Resolution=140.8 km (along-track); Horizontal_Resolution_Range=500 meters - < 1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].

EOSDIS↗

LED Intensity Decay Particle Tracking Velocimetry

A particle tracking velocimetry (PTV) system is demonstrated that eliminates the need for expensive lasers and cameras, and encodes the particle tracks with a known intensity variation which allows for high-resolution particle velocity and directionality determination. Using a light-emitting diode (LED) as the light source significantly reduces cost and allows for eye-safe operation, in comparison to traditional laser systems. The intensity variation control is passive, being dictated by the capacitance discharge rate in the LED pulsing circuit. The decay rate can be adjusted with the LED circuit capacitors/resistors, while the duration of the decay can be adjusted with the LED trigger pulse width. Because the intensity decay illumination is controlled by the LED, a single long exposure camera image is used to acquire images of the particle streaks, and there is no need for a more complicated and costly double-pulsing camera. With the intensity coding of the light, a single-camera/ single-LED system can identify particles entering of leaving the illumination plane, but cannot discern the direction toward or away from the camera. By using a two-color system, three-dimensionality of the particle tracks can be determined.

Joshua M Weisberger↗

A High-Sensitivity Fast Neutron Imager

A wide range of NSC (Neutron Scatter Camera) activities were conducted under this lifecycle plan. This document outlines the highlights of those activities, broadly characterized as system improvements, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

47 OTHER INSTRUMENTATION↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Red nuggets grow inside-out: evidence from gravitational lensing

Here, we present a new sample of strong gravitational lens systems where both the foreground lenses and background sources are early-type galaxies. Using imaging from Hubble Space Telescope (HST)/Advanced Camera for Studies (ACS) and Keck/NIRC2, we model the surface brightness distributions and show that the sources form a distinct population of massive, compact galaxies at redshifts 0.4 ≲ z ≲ 0.7, lying systematically below the size–mass relation of the global elliptical galaxy population at those redshifts. These may therefore represent relics of high-redshift red nuggets or their partly evolved descendants. We exploit the magnifying effect of lensing to investigate the structural properties, stellar masses and stellar populations of these objects with a view to understanding their evolution. We model these objects parametrically and find that they generally require two Sérsic components to properly describe their light profiles, with one more spheroidal component alongside a more envelope-like component, which is slightly more extended though still compact. This is consistent with the hypothesis of the inside-out growth of these objects via minor mergers. Lastly, we also find that the sources can be characterized by red-to-blue colour gradients as a function of radius which are stronger at low redshift – indicative of ongoing accretion – but that their environments generally appear consistent with that of the general elliptical galaxy population, contrary to recent suggestions that these objects are pre-dominantly associated with clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment D015: Night image intensification

A performance test of a night image intensification system for use as a visual aid by the crewmen in Gemini is reported. The equipment package consisted of (1) image intensification camera; (2) camera control unit; (3) viewing monitor; (4) recording monitor and photographic recorder; and (5) monitor electronics and equipment control unit. Representative photographs are predominantly of lights and clouds. Photographs of three different sections of coastline reveal a contrast between the images of land and ocean. These images range in quality from good to poor.

Shopple, T. J.↗