At least 1,243 records · Page 69

Review of biological mechanisms for application to instrument design

Biological sensors are the mechanisms which enable a living organism to monitor its environment. Ways in which the functional mechanism of biosensors can be applied to develop new concepts of instrumentation, enhance and extend the human senses, and improve the sensitivity of existing instrumentation are described in a review of these mechanisms.

Healer, J.↗

Laser-Doppler gas-velocity instrument

Three-D instrument using a laser light source measures both turbulence and mean velocity of subsonic and supersonic gas flows. This instrument is based on the measurement of the Doppler frequency shift of light waves scattered by moving particles in the gas stream.

Booth, S.↗

Compensation of pulse-rebalanced inertial instruments

Study explains the basic concept of pulse-rebalanced inertial instruments in terms of an idealized model which performs the processes of integration, prediction and quantization. An analytical model of an actual pulse-rebalanced instrument was derived in a form comparable to the idealized system.

Lory, C. B.↗

The effects of nuclear power generators upon electronic instrumentation

Radiation sensitivity of electronic instruments susceptible to neutron and gamma radiation is evaluated by means of a radioisotope thermoelectric generator /RTG/. The gamma field of the RTG affects instrument operation and requires shielding, the neutron field does not affect operation via secondary capture-gamma production.

Miller, C. G.↗

Design and development of a fast scan infrared detection and measurement instrument

Infrared microscope instrument measures and plots the infrared profile of semiconductor chips, transistors and integrated circuits. Infrared analyses yields information on electrical and physical properties, enabling manufacturing improvements in semiconductor performance and reliability. Operational performance and main sections of the instrument are given.

Dostoomian, A. S.↗

Electrical instrument measures position and velocity of shock waves

Instrument employs a sensor consisting of twin-electrode probe mounted in shock tube wall, with small dc voltage impressed across electrodes. Power supply, amplifier, and gate pulse generator complete the system. Instrument provides data for construction of wave diagrams, as well as measurement of shock velocity.

Dannenberg, R. E.↗

Instrument accurately measures stress loads in threaded bolts

Interferometric instrument response is linearly related to axial tensile stresses, and, under idealized conditions, measurement errors are within approximately plus or minus 1 percent. Ultimate accuracy of instrument depends on a number of variables, such as bolt material, dimensions, and geometry and uniformity of stresses and temperature.

Rollins, F. R., Jr.↗

A rocket borne instrument to measure electric fields inside electrified clouds

The development of a rocket borne instrument to measure electric fields in thunderstorms is described. Corona currents from a sharp needle atop a small rocket are used to sense the electric field. A high ohm resistor in series with the corona needle linearizes the relationship between corona current and electric field. The corona current feeds a relaxation oscillator, whose pulses trigger a transmitter which operates in the 395 to 410 MHz meteorological band. The instrument senses fields between 5 kV/m and 100 kV/m.

Ruhnke, L. H.↗

Development of a wideband wattmeter as a laboratory instrument

A portable, solid state, wideband wattmeter has been developed as a general purpose type of laboratory instrument. Its circuit and component investigations and evaluation data are presented. A prototype unit was used extensively, and served as the basis for a second instrument incorporating refined circuitry and improved packaging. The wattmeter provides true four quadrant operation which permits instantaneous indication of real power as an oscilloscope display. Major performance factors are: frequency bandwidth DC to 1 MHz plus or minus 1 db; current range 10 mA to 100 amperes peak; voltage range 1 volt to 1000 volts peak; accuracy plus or minus 2% of full scale reading. Oscilloscope data for typical switching transients in a transistor inverter circuit are included.

Landes, L. G.↗

Pilot dynamics for instrument approach tasks: Full panel multiloop and flight director operations

Measurements and interpretations of single and mutiloop pilot response properties during simulated instrument approach are presented. Pilot subjects flew Category 2-like ILS approaches in a fixed base DC-8 simulaton. A conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Reduced and interpreted pilot describing functions and remmant are given for pitch attitude, flight director, and multiloop (longitudinal) control tasks. The response data are correlated with simultaneously recorded eye scanning statistics, previously reported in NASA CR-1535. The resulting combined response and scanning data and their interpretations provide a basis for validating and extending the theory of manual control displays.

Weir, D. H.↗

STDN network operations procedure for Apollo range instrumentation aircraft, revision 1

The Apollo range instrumentation aircraft (ARIA) fleet which consists of four EC-135N aircraft used for Apollo communication support is discussed. The ARIA aircraft are used to provide coverage of lunar missions, earth orbit missions, command module/service module separation to spacecraft landing, and assist in recovery operations. Descriptions of ARIA aircraft, capabilities, and instrumentation are included.

Vette, A. R.↗

Effects of electrons and protons on science instruments

The radiation effects on typical science instruments according to the Jupiter trapped radiation design restraint model are described, and specific aspects of the model where an improved understanding would be beneficial are suggested. The spacecraft design used is the TOPS 12L configuration. Ionization and displacement damage are considered, and damage criteria are placed on the most sensitive components. Possible protective measures are mentioned: selecting components as radiation resistant as possible, using a difference in desired and undesired signal shapes for electronic shielding, orienting and locating the component on the spacecraft for better shielding, and adding passive shields to protect specific components. Available options are listed in decreasing order of attractiveness: attempt to lower the design restraints without compromising the success of the missions, trade off experiment objectives for increased reliability, alter the trajectory, and remove sensitive instruments from the payload.