Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Durable Suit Bladder with Improved Water Permeability for Pressure and Environment Suits

Water vapor permeability is shown to be useful in rejecting heat and managing moisture accumulation in launch-and-entry pressure suits. Currently this is accomplished through a porous Gortex layer in the Advanced Crew and Escape Suit (ACES) and in the baseline design of the Constellation Suit System Element (CSSE) Suit 1. Non-porous dense monolithic membranes (DMM) that are available offer potential improvements for water vapor permeability with reduced gas leak. Accordingly, three different pressure bladder materials were investigated for water vapor permeability and oxygen leak: ElasthaneTM 80A (thermoplastic polyether urethane) provided from stock polymer material and two custom thermoplastic polyether urethanes. Water vapor, carbon dioxide and oxygen permeability of the DMM's was measured in a 0.13 mm thick stand-alone layer, a 0.08 mm and 0.05 mm thick layer each bonded to two different nylon and polyester woven reinforcing materials. Additional water vapor permeability and mechanical compression measurements were made with the reinforced 0.05 mm thick layers, further bonded with a polyester wicking and overlaid with moistened polyester fleece thermal underwear .This simulated the pressure from a supine crew person. The 0.05 mm thick nylon reinforced sample with polyester wicking layer was further mechanically tested for wear and abrasion. Concepts for incorporating these materials in launch/entry and Extravehicular Activity pressure suits are presented.

Bue, Grant C.↗

Hanford Double Shell Tank Integrity Inspection - Integration of Customized Robotics - 18400

28 steel, double-shell, million gallon waste storage tanks located at the Hanford site in Washington State store both radioactive and hazardous waste. To monitor their condition and ensure continued viability, these tanks are inspected periodically through a comprehensive integrity program. In 2012, the first leak in a double-shell tank at Hanford was discovered in the 241-AY tank farm (Tank AY-102) and the failure was observed to be from the primary tank bottom. However, the exact failure location and damage mechanism have not been determined. A decision was made to pursue the capability to inspect the primary tank bottom region in order to provide additional tank integrity information. This work is particularly challenging due to the confined space in the double-shell tank annulus region (i.e. the 30 inch space between the primary and secondary tank shells), the limited dimensions of the tank risers that provide access to the annulus space (risers as small as 10 inches in diameter), and also the very small dimensions of the air channels in the concrete refractory pad that the primary waste storage tank rests on (channels are approximately two inches in diameter). Veolia Nuclear Solutions, along with Key Subcontractor Inuktun, were contracted to provide the capability to conduct these tank inspections in support of Hanford's double-shell tank integrity program. The Veolia Nuclear Solutions /Inuktun team designed, built, tested and delivered a tethered miniature robotic crawler system that utilizes the marsupial approach - a larger deployment crawler positions a smaller inspection crawler. The deployment crawler is installed via the tank riser, is magnetically coupled to the side of the tank shell, and drives to the selected deployment location at the end of one of the refractory channels where the small inspection robot is subsequently deployed. Operation of the equipment is controlled from a trailer outside the tank farm (a distance of several hundred feet). The system design includes a custom mechanism that provides for positioning and cable handling as well as the controls interface (laptop connected via control cables). The solution leveraged the Veolia Nuclear Solutions/Inuktun team's experience with delivering similar modular systems for other US and international sites. This simple but innovative solution delivered on an accelerated project schedule underlines the ability to provide effective robotic solutions to the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flight Servicing of Robotic Refueling Mission 3

The Robotic Refueling Mission 3 (RRM3) payload launched aboard a SpaceX rocket en route to the International Space Station on December 5th, 2018. The Goddard Space Flight Center designed payload carried approximately 50 liters of liquid methane onboard, with a mission to demonstrate long term storage and transfer of the cryogenic fluid in microgravity. Kennedy Space Center (KSC) was tasked to design, fabricate, test, and operate a system equipped to fill an RRM3 dewar with liquid methane prior to launch. Though KSC has a rich history of fueling rockets and payloads, no such operations had previously been accomplished using liquid methane. As such, all of the hardware and processes had to be developed from scratch. The completed ground system design, along with the verification and validation testing will be outlined in this paper. Several challenges that were met and overcome during procurement of the high purity methane are described. In addition, budget restrictions prohibited fueling operations from occurring in traditional processing facilities. The unique and creative solutions which were required to maintain payload cleanliness during cryogenic servicing are also detailed.

Cryogenics↗

Upstream energetic ions under radial IMF - A critical test of the Fermi model

Eight years of interplanetary magnetic field (IMF) and energetic particle observations obtained by the IMP-8 spacecraft upstream from the bow shock have been surveyed, and 63 cases when the upstream IMF remained radial for extended periods of time (greater than 1 hour) have been accumulated. Of these, two cases have been selected during which measurable fluxes of ambient solar or corotating energetic particle events were absent. These conditions provide an excellent test to the theories of the origin of upstream energetic ions. It is shown that there are extended periods with radial IMF when no upstream energetic ions were detected. It is further shown that energetic ions in the range E of between 50 keV and 1 MeV, inclusive, are not continuously present but appear in bursts of intensities varying by more than an order of magnitude under persistently radial IMF. These measurements contradict a fundamental prediction of the Fermi mechanism for the origin of the upstream energetic ions, namely that such ions should always be present on radial IMF lines. The observations are consistent with the hypothesis that energetic (greater than about 50 keV) ions leak out from, and appear in the upstream medium sporadically, following the onset of magnetic activity within the magnetosphere.

Sarris, E. T.↗

A Magnetically Coupled Cryogenic Pump

Historically, cryogenic pumps used for propellant loading at Kennedy Space Center (KSC) and other NASA Centers have a bellows mechanical seal and oil bath ball bearings, both of which can be problematic and require high maintenance. Because of the extremely low temperatures, the mechanical seals are made of special materials and design, have wearing surfaces, are subject to improper installation, and commonly are a potential leak path. The ball bearings are non-precision bearings [ABEC-1 (Annular Bearing Engineering Council)] and are lubricated using LOX compatible oil. This oil is compatible with the propellant to prevent explosions, but does not have good lubricating properties. Due to the poor lubricity, it has been a goal of the KSC cryogenics community for the last 15 years to develop a magnetically coupled pump, which would eliminate these two potential issues. A number of projects have been attempted, but none of the pumps was a success. An off-the-shelf magnetically coupled pump (typically used with corrosive fluids) was procured that has been used for hypergolic service at KSC. The KSC Cryogenics Test Lab (CTL) operated the pump in cryogenic LN2 as received to determine a baseline for modifications required. The pump bushing, bearings, and thrust rings failed, and the pump would not flow liquid (this is a typical failure mode that was experienced in the previous attempts). Using the knowledge gained over the years designing and building cryogenic pumps, the CTL determined alternative materials that would be suitable for use under the pump design conditions. The CTL procured alternative materials for the bearings (bronze, aluminum bronze, and glass filled PTFE) and machined new bearing bushings, sleeves, and thrust rings. The designed clearances among the bushings, sleeves, thrust rings, case, and case cover were altered once again using experience gained from previous cryogenic pump rebuilds and designs. The alternative material parts were assembled into the pump, and the pump was successfully operated meeting all expected operating parameters. Unique pump sub-assembly parts were designed and manufactured by the CTL using specialized materials determined to be superior for cryogenic thermal applications under the pump design conditions. This work is a proof-of-concept/proof-of-operation of the pump only. Other known internal design modifications to the pump should be accomplished for the long-term use of the pump. An upscaled version of this pump, which is under development and testing at the CTL, can be used either for current or future vehicle loading or for vehicle replenishment. Scaling of this pump can be easily accomplished.

Hatfield, Walter↗

CH Packaging Program Guidance

The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evolving Applications of Aerosol Sealant

Solving the issues facing the residential building industry today requires developing not only new technologies but also new, innovative applications of existing high-performance technologies. The U.S. Department of Energy's (DOE's) Building America Program is using this approach to develop a low-cost, easy solution for whole-home envelope air sealing. Aerosol sealant is a proven method for sealing ducts quickly and efficiently, especially in hard-to-reach places. This technology, originally developed at Lawrence Berkeley National Laboratory in 1994 with support from DOE, seals 70%-90% of duct leaks (LBNL n.d.), saving $600-$850 per year in energy costs for an average household (DOE 2011). A new, innovative application takes this technology out of the duct system and into the conditioned space. Recent Building America projects have validated a method for whole-house air sealing using the aerosol sealant technology. With tighter envelope requirements in new codes and above-code programs, adequately air sealing by hand is more labor-intensive and costly than ever. The aerosol sealing method is designed to eliminate the guesswork and automate this process. The continuous measurement during installation allows builders to dial in the exact air tightness they need to meet their performance goals. Initial field testing shows that this method regularly achieves air leakage levels less than 1 ACH50 as measured by a blower door test. In a current Building America project, the Center for Energy and Environment is performing iterative field tests in 20 homes to identify the optimal integration and sequencing of this method in production home building processes to achieve a lower installation cost than traditional air sealing. This method has the potential to improve quality assurance of envelope sealing and significantly reduce labor costs compared with traditional air sealing approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rock Physics-Based Data Assimilation of Integrated Continuous Active-Source Seismic and Pressure Monitoring Data during Geological Carbon Storage

Summary There has been substantial controversy concerning the role of geological carbon storage (GCS) in sequestering anthropogenic carbon emissions to mitigate climate change and global warming. Arguments center on the inability to monitor a geological storage site precisely and continuously, especially highlighting the associated costs and spatiotemporal trade-offs when using conventional subsurface monitoring techniques (well logs, core samples, chemical tracers, and 4D seismics). Active surveillance of GCS sites is essential for managing and mitigating potential leaks but is also required by regulation. With the goal of enhancing the monitoring capability at GCS sites, we present a rock physics-based joint data assimilation model to study a popular GCS site at Cranfield, Mississippi, USA. Synthetic continuous active-source seismic monitoring (CASSM) data (in the form of Vp and Qp measurements) and wellbore pressure monitoring data are assimilated with an ensemble of reservoir realizations to monitor gas saturation and reservoir pressure changes over a period of 100 years. Synthetic seismic attributes are generated using rock physics models (RPMs) and wellbore pressure monitoring data are extracted from the ground truth. Two assimilation methods, ensemble Kalman filter (EnKF) and ensemble Kalman smoother (EnKS), are tested in an observation system simulation experiment (OSSE) environment to assess the prediction accuracy of the individual and composite observation systems. The joint monitoring system achieves more accurate estimates of gas saturation and pressure, across the time span from start of injection to end of forecast, as compared to a single type of monitoring tool and irrespective of data assimilation algorithm choice. These results indicate that jointly assimilated data from two types of sensors (in this case, crosswell seismic and downhole pressure) may lead to a more risk-reducing monitoring design. One would expect that more data, vis-à-vis inclusion of a new sensor type, will improve the accuracy of any GCS monitoring system. However, from a practical standpoint, one important question is whether such a gain in accuracy is worth the additional cost associated with the new sensor. This paper focuses on quantifying the gain in accuracy, such that a practitioner can answer this question.

Engineering↗

Shale-Gas Experience as an Analog for Potential Wellbore Integrity Issues in CO2 Sequestration

Shale-gas development in Pennsylvania since 2003 has resulted in about 19 documented cases of methane migration from the deep subsurface (7,0000) to drinking water aquifers, soils, domestic water wells, and buildings, including one explosion. In all documented cases, the methane leakage was due to inadequate wellbore integrity, possibly aggravated by hydrofracking. The leakage of methane is instructive on the potential for CO{sub 2} leakage from sequestration operations. Although there are important differences between the two systems, both involve migrating, buoyant gas with wells being a primary leakage pathway. The shale-gas experience demonstrates that gas migration from faulty wells can be rapid and can have significant impacts on water quality and human health and safety. Approximately 1.4% of the 2,200 wells drilled into Pennsylvania's Marcellus Formation for shale gas have been implicated in methane leakage. These have resulted in damage to over 30 domestic water supplies and have required significant remediation via well repair and homeowner compensation. The majority of the wellbore integrity problems are a result of over-pressurization of the wells, meaning that high-pressure gas has migrated into an improperly protected wellbore annulus. The pressurized gas leaks from the wellbore into the shallow subsurface, contaminating drinking water or entering structures. The effects are localized to a few thousands of feet to perhaps two-three miles. The degree of mixing between the drinking water and methane is sufficient that significant chemical impacts are created in terms of elevated Fe and Mn and the formation of black precipitates (metal sulfides) as well as effervescing in tap water. Thus it appears likely that leaking CO{sub 2} could also result in deteriorated water quality by a similar mixing process. The problems in Pennsylvania highlight the critical importance of obtaining background data on water quality as well as on problems associated with previous (legacy) oil and gas operations. The great majority of the leakage issues in Pennsylvania are due to improperly abandoned wells, however in the media there is no clear distinction between past and present problems. In any case, significant analytical work is required to attribute differing sources of methane (or CO{sub 2} in the case of sequestration). In Pennsylvania, a relatively lax regulatory environment appears to have contributed to the problem with inadequate oversight of well design and testing to ensure well integrity. New rules were adopted at the end of 2010, and it will be interesting to observe whether methane leakage problems are significantly reduced.

ABANDONED WELLS↗

Testbed and Simulation-based Evaluation of Privacy-preserving Algorithms for Smart Grid AMI Networks

Although smart meters are deployed in a lot of countries as a result of aiming to make the power grid more resilient and efficient, the data collection process from smart meters in Smart Grid (SG) has still challenges that relate to consumer privacy. Referred to as Advanced Metering Infrastructure (AMI), the data collected and transmitted through this AMI can leak sensitive information about the consumers if it is sent as plaintext. While a number of solutions have been proposed in the past, the deployment of these solutions in real-life was not possible since the actual AMIs were not accessible to researchers. Therefore, a lot of solutions relied on simulations which may not be able to capture the performance of these solutions. In this paper, we pick a widely used homomorphic-based aggregation and implement it in a realistic testbed so that it can be compared with a simulation-based solution. Specifically, we develop a system that provides privacy with the Paillier cryptosystem and twofactor authentication with ECDSA and OpenSSL certificates. In order to test the system, an IEEE 802.11s-based SG AMI network testbed is constructed with Beaglebone Black boards that imitate the behavior of smart meters. The same network is also simulated in widely used ns-3. The results showed that ns-3 simulation and testbed results are parallel in most cases and the proposed system can perform effectively. However, there are still many differences that need to be taken into account in deploying real systems.

97 MATHEMATICS AND COMPUTING↗

Multi-Node Modeling of Cryogenic Tank Pressurization System using Generalized Fluid System Simulation Program

This paper presents a multi-node model of autogenous pressurization of cryogenic propellant in a flight tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/Marshall Space Flight Center. Tests were conducted to measure the pressure and temperatures at the various axial locations of the stratified ullage at 75% and 45% fill level. Liquid nitrogen was pressurized by gaseous nitrogen from a supply tank while the drain valve from the tank remained closed during the pressurization process. The ullage was discretized into 25 uniformly distributed nodes: 5 in the radial direction and 5 in the axial direction assuming the flow to be axisymmetric. Heat and mass transfer between the liquid and vapor has been modeled at the liquid vapor interface. Heat transfer between wall and vapor at the ullage has been accounted for by assuming heat transfer occurs by natural convection. The model also accounts for heat leak to the tank through the insulation and metal wall by heat conduction. The predicted pressures and temperatures are compared with the measured data.

Bandyopadhyay, Alak↗

Sensitivity Analysis of an Experimental Breeder Reactor II Fuel Assembly

The Experimental Breeder Reactor II (EBR-II) was selected as a candidate for a reactor physics benchmark evaluation due to its unique features and capabilities. In connection with the benchmark evaluation, the goal of this work was to perform a sensitivity analysis. The EBR-II was a sodium cooled, pool type, metal fueled, fast spectrum reactor. EBR-II operated from 1964 through 1994. It had a maximum heat output of 62.5 MW which could produce 20 MW of electricity. The design of EBR-II consisted of 637 hexagonal shaped, removable assemblies. The assemblies were divided into three regions: the core, an inner blanket, and an outer blanket. The core region contained assemblies with 91 fuel rods in each. The fuel was enriched uranium metal and was clad within stainless steel. The core region also included two safety assemblies and eight control assemblies with the difference being that these assemblies only contained 61 fuel rods. Additional assemblies in the core region included stainless steel dummies, half worth drivers, and experimental/instrumentation assemblies. The inner blanket region initially consisted of depleted uranium for fuel breeding, but was replaced, after proving the concept of breeding, with stainless steel reflectors for the purpose of irradiation. The outer blanket region consisted of depleted uranium. Figure 1 shows a cross section view of the EBR-II core layout. Each assembly was approximately 234 cm long with the uranium fuel section being 33 cm long. Above and below the fuel were stainless steel neutron reflectors. Additionally, orifices at the bottom of the assembly allowed for sodium coolant to flow upward, with larger holes in the subassemblies at the center where the greatest heat was produced. The core of EBR-II was enclosed by a stainless steel reactor vessel which was comprised of a radial shell, a lower grid plenum structure, and an upper reactor vessel cover that served as a neutron shield. Surrounding the reactor vessel radially were layers of graphite and borated graphite shielding. The entire assembly is submerged 3 meters in a pool of sodium. The pool contained up to 337,000 liters of sodium which was forced through the core and blanket regions using two centrifugal pumps that were also submerged within the sodium pool. The design of EBR-II included many safety features. The compatibility between the sodium and stainless steel prevented corrosion and therefore the risk of a radioactive release due to corrosion. The sodium coolant was kept at near atmospheric pressure which made any leak more controllable. The metal fuel, cladding, and coolant allowed for heat to be removed easily. The large volume of sodium allowed for heat to be absorbed without problems occurring. Lastly, the reactor would expand as temperature increased which would result in greater neutron leakage. This extra leakage caused a large negative temperature reactivity feedback which automatically shut the reactor down in case of an accident. EBR-II had unique capabilities which were proven during the Integral Fast Reactor initiative. This program lasted from 1984 to 1994. The goal of this program was to solve many of the perceived problems with nuclear energy through scientific means. The safety features of EBR-II were put to the test in April 1986. The tests simulated loss of reactor coolant flow and loss of a heat sink. For both of these tests, the reactor was at 100% power and was not scrammed. During both tests, the reactor shut itself down and achieved a safe steady state temperature all due to the design of the reactor. It was because of these tests that EBR-II was chosen for a reactor physics benchmark evaluation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report on the Initial Fundamental Sodium-CO 2 Interaction Experiment

The U.S. Department of Energy (U.S. DOE) Advanced Reactor Concepts (ARC) Program is developing the Sodium-Cooled Fast Reactor (SFR) as a reactor that could dramatically improve performance in sustainability, safety, economics, security, and proliferation resistance. The near-term Program goal is to reduce technical barriers to improve the prospects of advanced technology reactor systems. In the long-term, integrated advanced reactor system designs will be developed that implement the chosen missions and complete the testing and demonstration necessary for licensing. The supercritical carbon dioxide (S-CO 2 ) Brayton cycle, coupled with an SFR, has been identified as a new and innovative energy conversion technology that could contribute to meeting these objectives especially in terms of improving economics. One appealing feature of this energy conversion system is the smaller footprint that the hardware requires relative to the traditional superheated steam cycle, which is in part due to the use of Printed Circuit Heat Exchanger TM (PCHE TM ) compact diffusion-bonded heat exchangers as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the secondary heat exchanger cannot be ruled out, leading to discharge of high pressure CO2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO2 jet blowdown into the intermediate sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The 2012 Sodium Fast Reactor Research Plan produced by Sandia National Laboratory (Denman et al., 2012) identified the interaction between sodium and CO 2 as being among the highest priority areas of research for SFR accident initiators. In fact, the report rated both the experimental database and modeling capabilities of Na-CO 2 interactions at the lowest current state of knowledge compared with the other listed high-priority accident initiator items. In recognition of the anticipated failure mode for a PCHE sodium-to-CO 2 heat exchanger, an Argonne experiment program, called SNAKE, was initiated in FY 2010 to investigate the reaction characteristics between sodium and CO 2 under micro-leak conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Drug-Inducible Gene Therapy Effectively Reduces Spontaneous Seizures in Kindled Rats but Creates Off-Target Side Effects in Inhibitory Neurons

Over a third of patients with temporal lobe epilepsy (TLE) are not effectively treated with current anti-seizure drugs, spurring the development of gene therapies. The injection of adeno-associated viral vectors (AAV) into the brain has been shown to be a safe and viable approach. However, to date, AAV expression of therapeutic genes has not been regulated. Moreover, a common property of antiepileptic drugs is a narrow therapeutic window between seizure control and side effects. Therefore, a long-term goal is to develop drug-inducible gene therapies that can be regulated by clinically relevant drugs. In this study, a first-generation doxycycline-regulated gene therapy that delivered an engineered version of the leak potassium channel Kcnk2 (TREK-M) was injected into the hippocampus of male rats. Rats were electrically stimulated until kindled. EEG was monitored 24/7. Electrical kindling revealed an important side effect, as even low expression of TREK M in the absence of doxycycline was sufficient to cause rats to develop spontaneous recurring seizures. Treating the epileptic rats with doxycycline successfully reduced spontaneous seizures. Localization studies of infected neurons suggest seizures were caused by expression in GABAergic inhibitory neurons. In contrast, doxycycline increased the expression of TREK-M in excitatory neurons, thereby reducing seizures through net inhibition of firing. These studies demonstrate that drug-inducible gene therapies are effective in reducing spontaneous seizures and highlight the importance of testing for side effects with pro-epileptic stressors such as electrical kindling. These studies also show the importance of evaluating the location and spread of AAV-based gene therapies in preclinical studies.

60 APPLIED LIFE SCIENCES↗

Tank 241-AY-102 Secondary Liner Corrosion Evaluation - 14191

In October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of 241-AY-102 (AY-102) was leaking. A number of evaluations were performed after discovery of the leak which identified corrosion from storage of waste at the high waste temperatures as one of the major contributing factors in the failure of the tank. The propensity for corrosion of the waste on the annulus floor will be investigated to determine if it is corrosive and must be promptly removed or if it is benign and may remain in the annulus. The chemical composition of waste, the temperature and the character of the steel are important factors in assessing the propensity for corrosion. Unfortunately, the temperatures of the wastes in contact with the secondary steel liner are not known; they are estimated to range from 45 deg C to 60 deg C. It is also notable that most corrosion tests have been carried out with un-welded, stress-relieved steels, but the secondary liner in tank AY-102 was not stress-relieved. In addition, the cold weather fabrication and welding led to many problems, which required repeated softening of the metal to flatten secondary bottom during its construction. This flame treatment may have altered the microstructure of the steel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A global stochastic programming approach for the optimal placement of gas detectors with nonuniform unavailabilities

Optimal design of a gas detection systems is challenging because of the numerous sources of uncertainty, including weather and environmental conditions, leak location and characteristics, and process conditions. Rigorous CFD simulations of dispersion scenarios combined with stochastic programming techniques have been successfully applied to the problem of optimal gas detector placement; however, rigorous treatment of sensor failure and nonuniform unavailability has received less attention. To improve reliability of the design, this paper proposes a problem formulation that explicitly considers nonuniform unavailabilities and all backup detection levels. The resulting sensor placement problem is a large-scale mixed-integer nonlinear programming (MINLP) problem that requires a tailored solution approach for efficient solution. We have developed a multitree method which depends on iteratively solving a sequence of upper-bounding master problems and lower-bounding subproblems. The tailored global solution strategy is tested on a real data problem and the encouraging numerical results indicate that our solution framework is promising in solving sensor placement problems. This study was selected for the special issue in JLPPI from the 2016 International Symposium of the MKO Process Safety Center.

47 OTHER INSTRUMENTATION↗

Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

degradation mechanisms↗