Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have trifaceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module. Methods: That this simple collimator model can produce spatially and dosimetrically accurate microcollimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms. Results: Monte Carlo dose calculations for on-axis and off-axis fields are shown to produce good agreement with experimental values, even on close examination of the penumbrae. Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High energy electron crystal spectrometer

A spectrometer has been developed to measure relativistic electrons produced in different types of plasmas, such as tokamak plasmas and laser produced plasmas. The spectrometer consists of nine Y{sub 2}SiO{sub 5}:Ce crystals, which are shielded by stainless steel filters. The absolute calibration of the spectrometer was performed at the superconducting electron linear accelerator Electron Linac for beams with high Brilliance and low Emittance. The spectrometer can provide information about energy distribution of electrons and their numbers for the energy range between 4 and 30 MeV. The spectrum is analyzed by means of the Monte Carlo three-dimensional GEANT4 code. An energy resolution of about 10% is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-T-04: Variations in Nominally Identical Small Fields From Photon Jaw Reproducibility and Associated Effects On Small Field Dosimetric Parameters

Purpose: To investigate uncertainties in small field output factors and detector specific correction factors from variations in field size for nominally identical fields using measurements and Monte Carlo simulations. Methods: Repeated measurements of small field output factors are made with the Exradin W1 (plastic scintillation detector) and the PTW microDiamond (synthetic diamond detector) in beams from the Elekta Precise linear accelerator. We investigate corrections for a 0.6x0.6 cm{sup 2} nominal field size shaped with secondary photon jaws at 100 cm source to surface distance (SSD). Measurements of small field profiles are made in a water phantom at 10 cm depth using both detectors and are subsequently used for accurate detector positioning. Supplementary Monte Carlo simulations with EGSnrc are used to calculate the absorbed dose to the detector and absorbed dose to water under the same conditions when varying field size. The jaws in the BEAMnrc model of the accelerator are varied by a reasonable amount to investigate the same situation without the influence of measurements uncertainties (such as detector positioning or variation in beam output). Results: For both detectors, small field output factor measurements differ by up to 11 % when repeated measurements are made in nominally identical 0.6x0.6 cm{sup 2} fields. Variations in the FWHM of measured profiles are consistent with field size variations reported by the accelerator. Monte Carlo simulations of the dose to detector vary by up to 16 % under worst case variations in field size. These variations are also present in calculations of absorbed dose to water. However, calculated detector specific correction factors are within 1 % when varying field size because of cancellation of effects. Conclusion: Clinical physicists should be aware of potentially significant uncertainties in measured output factors required for dosimetry of small fields due to field size variations for nominally identical fields.

07 ISOTOPE AND RADIATION SOURCES↗

ORNL Neutron Cross Section Measurements of 90 Zr

Nuclear criticality modeling and simulations rely on the quality of the existing evaluated nuclear data libraries such as Evaluated Nuclear Data File (ENDF)/B, the Joint Evaluated Fission and Fusion (JEFF) nuclear data library, or the Japanese Evaluated Nuclear Data Library (JENDL). In some cases, the cross-section evaluations of those libraries were found to be deficient in describing criticality benchmarks accurately. More than two decades ago, the US Nuclear Criticality Safety Program (NCSP) established a Nuclear Data (ND) task which encompassed experiments and evaluations. In response to this, the Oak Ridge National Laboratory (ORNL) formed a Nuclear Criticality and Data group which performed ND experiments, data analysis, and evaluations to produce ENDF files for the ND libraries as identified in the NCSP Five-Year Plan. Before being submitted to the ENDF library, files were processed and tested for performance by running benchmark calculations. This procedure was centralized in the ORNL group and is now often referred to as the ND pipeline. NCSP collaborates with the Joint Research Center (JRC) of the European Commission in Geel, Belgium, to perform high-resolution neutron-induced cross section measurements at the Geel Linear Accelerator (GELINA). The objective is to address emerging ND problems in criticality calculations. Difficulties with ND include insufficient neutron energy range, missing covariances, and previously unrecognized inaccuracies with experiments. New neutron total and capture cross sections of 90 Zr in the neutron energy range from 100 eV to several hundred keV were recently performed. These measured data will be used, together with existing high-resolution transmission data from a metallic 90 Zr sample, to improve representation of the cross sections.

97 MATHEMATICS AND COMPUTING↗

Observations of the Askaryan Effect in Ice

We report on observations of coherent, impulsive radio Cherenkov radiation from electromagnetic showers in solid ice. This is the first observation of the Askaryan effect in ice. As part of the complete validation process for the ANITA experiment, we performed an experiment at the Stanford Linear Accelerator Center in June 2006 using a 7.5 metric ton ice target. We measure for the first time the large-scale angular dependence of the radiation pattern, a major factor in determining the solid-angle acceptance of ultrahigh-energy neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

60 APPLIED LIFE SCIENCES↗

Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams

Purpose: For commercially available linear accelerators (Linacs), the electron energies of flattening filter free (FFF) and flattened (FF) beams are either identical or the electron energy of the FFF beam is increased to match the percentage depth dose curve (PDD) of the FF beam (in reference geometry). This study focuses on the primary dose components of FFF beams for both kinds of settings, studied on the same Linac. Methods: The measurements were conducted on a VersaHD Linac (Elekta, Crawley, UK) for both FF and FFF beams with nominal energies of 6 and 10 MV. In the clinical setting of the VersaHD, the energy of FFF{sub M} (Matched) beams is set to match the PDDs of the FF beams. In contrast the incident electron beam of the FFF{sub U} beam was set to the same energy as for the FF beam. Half value layers (HVLs) and a dual parameter beam quality specifier (DPBQS) were determined. Results: For the 6 MV FFF{sub M} beam, HVL and DPBQS values were very similar compared to those of the 6 MV FF beam, while for the 10 MV FFF{sub M} and FF beams, only %dd(10){sub x} and HVL values were comparable (differences below 1.5%). This shows that matching the PDD at one depth does not guarantee other beam quality dependent parameters to be matched. For FFF{sub U} beams, all investigated beam quality specifiers were significantly different compared to those for FF beams of the same nominal accelerator potential. The DPBQS of the 6 MV FF and FFF{sub M} beams was equal within the measurement uncertainty and was comparable to published data of a machine with similar TPR{sub 20,10} and %dd(10){sub x}. In contrast to that, the DPBQS’s two parameters of the 10 MV FFF{sub M} beam were substantially higher compared to those for the 10 MV FF beam. Conclusions: PDD-matched FF and FFF beams of both nominal accelerator potentials were observed to have similar HVL values, indicating similarity of their primary dose components. Using the DPBQS revealed that the mean attenuation coefficient was found to be the same within the uncertainty of 0.8% for 6 MV FF and 6 MV FFF{sub M} beams, while for 10 MV beams, they differed by 6.4%. This shows that the DPBQS can provide a differentiation of photon beam characteristics that would remain hidden by the use of a single beam quality specifier, such as %dd(10){sub x} or HVL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam

A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere with signals transmitted through the fiber. We determine the spectrum of the Cerenkov background signal generated in a poly(methyl methacrylate) optical fiber exposed to photon and electron therapeutic beams from a linear accelerator. This spectral measurement is relevant to discrimination of the signal from the background, as in scintillation dosimetry using optical fiber readouts. We find that the spectrum is approximated by the theoretical curve after correction for the wavelength dependent attenuation of the fiber. The spectrum does not depend significantly on the angle between the radiation beam and the axis of the fiber optic but is dependent on the depth in water at which the fiber is exposed to the beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-JeP2-04: Comparison Between Fricke-Type 3D Radiochromic Dosimeters for Real-Time Dose Distribution Measurements in MR-Guided Radiation Therapy

Purpose: To assess MR signal contrast for different ferrous ion compounds used in Fricke-type gel dosimeters for real-time dose measurements for MR-guided radiation therapy applications. Methods: Fricke-type gel dosimeters were prepared in 4% w/w gelatin prior to irradiation in an integrated 1.5 T MRI and 7 MV linear accelerator system (MR-Linac). 4 different ferrous ion (Fe2?) compounds (referred to as A, B, C, and D) were investigated for this study. Dosimeter D consisted of ferrous ammonium sulfate (FAS), which is conventionally used for Fricke dosimeters. Approximately half of each cylindrical dosimeter (45 mm diameter, 80 mm length) was irradiated to ∼17 Gy. MR imaging during irradiation was performed with the MR-Linac using a balanced-FFE sequence of TR/TE = 5/2.4 ms. An approximate uncertainty of 5% in our dose delivery was anticipated since the MR-Linac had not yet been fully commissioned. Results: The signal intensities (SI) increased between the un-irradiated and irradiated regions by approximately 8.6%, 4.4%, 3.2%, and 4.3% after delivery of ∼2.8 Gy for dosimeters A, B, C, and D, respectively. After delivery of ∼17 Gy, the SI had increased by 24.4%, 21.0%, 3.1%, and 22.2% compared to the un-irradiated regions. The increase in SI with respect to dose was linear for dosimeters A, B, and D with slopes of 0.0164, 0.0251, and 0.0236 Gy{sup −1} (R{sup 2} = 0.92, 0.97, and 0.96), respectively. Visually, dosimeter A had the greatest optical contrast from yellow to purple in the irradiated region. Conclusion: This study demonstrated the feasibility of using Fricke-type dosimeters for real-time dose measurements with the greatest optical and MR contrast for dosimeter A. We also demonstrated the need to investigate Fe{sup 2+} compounds beyond the conventionally utilized FAS compound in order to improve the MR signal contrast in 3D dosimeters used for MR-guided radiation therapy. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH- 102SPS.

60 APPLIED LIFE SCIENCES↗

Nucleon Form Factors from BLAST

The BLAST (Bates Large Acceptance Spectrometer Toroid) experiment has been carried out at the MIT-Bates Linear Accelerator Center to study spin-dependent electron scattering from protons and deuterons with small systematic uncertainties. The experiment used a longitudinally polarized, intense electron beam stored in the Bates South Hall Ring in combination with isotopically pure, highly-polarized internal targets of polarized hydrogen and vector- and tensor-polarized deuterium from an atomic beam source. The BLAST data have been used to extract precise results for the elastic form factor ratios G{sub E}/G{sub M} of the proton and the neutron at low momentum transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for B{sup 0}{yields}K*{sup +}K*{sup -}

We report the results of a search for the decay B{sup 0}{yields}K*{sup +}K*{sup -} with a sample of 454{+-}5 million BB pairs collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the Stanford Linear Accelerator Center. We obtain an upper limit at the 90% confidence level on the branching fraction for B(B{sup 0}{yields}K*{sup +}K*{sup -})<2.0x10{sup -6}, assuming the decay is fully longitudinally polarized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-D-BRD-01: Image Guided SBRT II: Challenges ' Pitfalls

Stereotactic body radiation therapy (SBRT) has been effective treatment for the management of various diseases, which often delivers high radiation dose in a single or a few fractions. SBRT therefore demands precise treatment delivery to the tumor while sparing adjacent healthy tissue. Recent developments in image guidance enable target localization with increased accuracy. With such improvements in localization, image-guided SBRT has been widely adopted into clinical practice. In SBRT, high radiation dose is generally delivered with small fields. Therefore, it is crucial to accurately measure dosimetric data for the small fields during commissioning. In addition, image-guided SBRT demands accurate image localization to ensure safety and quality of patient care. Lately, the reports of AAPM TG 142 and TG 104 have been published and added recommendations for imaging devices that are integrated with the linear accelerator for SBRT. Furthermore, various challenges and potential pitfalls lie in the clinical implementation of image-guided SBRT. In this lecture, these challenges and pitfalls of image-guided SBRT will be illustrated and discussed from dosimetric, technical and clinical perspectives.Being a promising technique, image-guided SBRT has shown great potentials, and will lead to more accurate and safer SBRT treatments. Learning Objectives: To understand dosimetric challenges and pitfalls for IGRT application in SBRT. To understand major clinical challenges and pitfalls for IGRT application in SBRT. To understand major technical challenges and pitfalls for IGRT application in SBRT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-679: Retrospective Analysis of the Sensitivity of Planar Dose Measurements To Gamma Analysis Criteria

Purpose: IMRT QA using planar dose measurements is still a widely used method for checking the accuracy of treatment plans. A pass/fail judgment is made using gamma analysis based on a single endpoint. Using more stringent criteria is a way to increase the sensitivity to planning and delivery errors. Before such implementation, it is necessary to understand how the sensitivity to different gamma criteria settings affects gamma passing rates (GPR). Methods: 752 IMRT QA measurements were re-analyzed with varying distance to agreement (DTA) and dose difference (DD) percentages using a Matlab program. Other quantifying information such as the mean dose difference in the treatment target (defined as points that are greater than 80% of maximal dose) were stored in a relational database for retrospective analysis. Results: The average and standard deviation of GPR (%) fell from 99.84 ± (0.43) to 89.61 ± (6.08) when restricting DD from 5 − 1% respectively, as compared to a drop from 99.15 ± (1.19) to 95.00 ± (4.43), when restricting the DTA from 5 − 1 mm respectively. The mean dose difference (%) in the treatment target between measured and calculated dose was −1.96 ± (0. 83), −0.09 ± (0.98), and 1.44 ± (0. 86) for each of our institution’s three matched linear accelerators (LINAC 1, 2, and 3 respectively). For plans that are approximately 2.7 sigma below the mean GPR, an average of 78.4% of those plans were measured on LINAC 1 or 3, while only 48% of the total plans were run on those machines. Conclusion: The data demonstrates that when restricting gamma criterion, such as the DD, the greatest indicator of reduced GPR in our institution is which matched LINAC the plan was measured on. While small, these differences manifest themselves to levels comparable to other treatment related differences and possibly confound the gamma analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Imaging of Radiation Dose for Stereotactic Radiosurgery

The distributions of radiation dose for stereotactic radiosurgery, using a modified linear accelerator (Philips SL-25 and SRS-200), have been studied by using three different dosimeters: (1) ferrous-agarose-xylenol orange (FAX) gels, (2) TLD, and (3) thick-emulsion GafChromic dye film. These dosimeters were loaded into a small volume of defect in a phantom head. A regular linac stereotactic radiosurgery treatment was then given to the phantom head for each type of dosimeter. The measured radiation dose and its distributions were found to be in good agreement with those calculated by the treatment planning computer.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Simple Approach to the Technical Aspects of Radiosurgery Treatments

An approach to radiosurgery treatment that can be readily adopted in most radiotherapy centers with linear accelerators is presented. In our institution, a Leksell-type of neurosurgical frame, a computed tomography scanner, locally fabricated cones, and 6 MV X-ray beams are used to perform radiosurgery treatments. Collimated arcs with dose distributions that conform to the shape of the lesion in the transverse and the sagittal planes are used. It is argued that the uncertainties in the localization of the isocenter within a lesion and the specifications of the size of the target volume do not justify high precision mechanical devices for most radiosurgery treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗