Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Light flavor-singlet scalars and walking signals in N f = 8 QCD on the lattice

Based on the highly improved staggered quark action, we perform in this paper lattice simulations of N f = 8 QCD and confirm our previous observations, both of a flavor-singlet scalar meson (denoted as σ) as light as the pion and of various “walking signals” through the low-lying spectra, with higher statistics, smaller fermion masses m f , and larger volumes. We measure M π , F π , M ρ , M a 0 , M a 1 , M b 1 , M N , M σ , F σ , (φφ) (both directly and through the Gell-Mann-Oakes-Renner relation), and the string tension. The data are consistent with the spontaneously broken phase of the chiral symmetry, in agreement with the previous results: Ratios of the quantities to M π monotonically increase in the smaller m f region towards the chiral limit similarly to N f = 4 QCD, in sharp contrast to N f = 12 QCD where the ratios become flattened. We perform fits to chiral perturbation theory, with the value of F π found in the chiral limit extrapolation reduced dramatically to roughly 2/3 of the previous result, suggesting the theory is much closer to the conformal window. In fact, each quantity obeys the respective hyperscaling relation throughout a more extensive m f region compared with earlier works. The hyperscaling relation holds with roughly a universal value of the anomalous dimension, γ m ≃ 1, with the notable exception of M π with γ m ≃ 0.6 as in the previous results, which reflects the above growing up of the ratios towards the chiral limit. This is a salient feature (walking signal) of N f = 8, unlike either N f = 4, which has no hyperscaling relation at all, or N f = 12 QCD, which exhibits universal hyperscaling. The effective γ m Ξ γ m (m f ) of M π defined for each m f region has a tendency to grow towards unity near the chiral limit, in conformity with the Nambu-Goldstone boson nature, as opposed to the case of N f = 12 QCD where it is almost constant. We further confirm the previous observation of the light σ with mass comparable to the pion in the studied m f region. In a chiral limit extrapolation of the σ mass using the dilaton chiral perturbation theory and also using the simple linear fit, we find the value consistent with the 125 GeV Higgs boson within errors. Finally, our results suggest that the theory could be a good candidate for walking technicolor model, having anomalous dimension γ m ≃ 1 and a light flavor-singlet scalar meson as a technidilaton, which can be identified with the 125 GeV composite Higgs in the N f = 8 one-family model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-C-207-07: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Phantom Study

Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing a contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.

60 APPLIED LIFE SCIENCES↗

ML Enhancements via the Calculation of Rigid Body Modes (RBMs) for Mechanics Problems Implemented within the Albany Code Base

The algebraic multigrid approach known as smoothed aggregation is very efficient at solving systems that arise from elasticity problems. In order to construct an efficient algebraic multilevel method, a multigrid solver should be provided with a small set of vectors that represent the error components that are difficult to resolve. It is well-known that for linear elasticity problems, these components correspond to the the so-called rigid body modes (RBMs). The present document summarizes some new development within the Albany code base that has enabled the application of algebraic multigrid preconditioners from the ML package of Trilinos to mechanics problems implemented within Albany via a new function that calculates the RBMs using information about the problem's underlying mesh. The performance of these preconditioners is evaluated on four problems: a 3D static elasticity problem, a 3D non-linear elasticity problem, a 3D thermo-elasticity problem, and a 3D thermo-poro-plasticity problem. The tests reveal the superiority of the ML preconditioners over ILU preconditioners from the Trilinos Ifpack package for mechanics problems in Albany.

97 MATHEMATICS AND COMPUTING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Minimum acquisition time detection

Two different methods of target detection when the return signal is contaminated with noise are discussed and compared. The first method uses Neyman-Pearson detection philosophy and selects the threshold level to give a desired false alarm probability. The maximum probability of false alarm is constrained by the target cross scan velocity component. The second method (minimum acquisition time detection), which is similar to the ideal observer, selects the threshold level to minimize the expected target acquisition time. The probabilities of false alarm and missed detection are selected so that the errors produced by these effects produce the minimum acquisition time. Three different scan techniques - linear, spiral and two-mode scan - are studied and compared.

Brock, H. I.↗

Computer modeling of multiple-channel input signals and intermodulation losses caused by nonlinear traveling wave tube amplifiers

The multiple channel input signal to a soft limiter amplifier as a traveling wave tube is represented as a finite, linear sum of Gaussian functions in the frequency domain. Linear regression is used to fit the channel shapes to a least squares residual error. Distortions in output signal, namely intermodulation products, are produced by the nonlinear gain characteristic of the amplifier and constitute the principal noise analyzed in this study. The signal to noise ratios are calculated for various input powers from saturation to 10 dB below saturation for two specific distributions of channels. A criterion for the truncation of the series expansion of the nonlinear transfer characteristic is given. It is found that he signal to noise ratios are very sensitive to the coefficients used in this expansion. Improper or incorrect truncation of the series leads to ambiguous results in the signal to noise ratios.

Stankiewicz, N.↗

Effect of nonideal square-law detection on static calibration in noise-injection radiometers

The effect of nonideal square-law detection on the static calibration for a class of Dicke radiometers is examined. It is shown that fourth-order curvature in the detection characteristic adds a nonlinear term to the linear calibration relationship normally ascribed to noise-injection, balanced Dicke radiometers. The minimum error, based on an optimum straight-line fit to the calibration curve, is derived in terms of the power series coefficients describing the input-output characteristics of the detector. These coefficients can be determined by simple measurements, and detection nonlinearity is, therefore, quantitatively related to radiometric measurement error.

Hearn, C. P.↗

The evaluation of the OSGLR algorithm for restructurable controls

The detection and isolation of commercial aircraft control surface and actuator failures using the orthogonal series generalized likelihood ratio (OSGLR) test was evaluated. The OSGLR algorithm was chosen as the most promising algorithm based on a preliminary evaluation of three failure detection and isolation (FDI) algorithms (the detection filter, the generalized likelihood ratio test, and the OSGLR test) and a survey of the literature. One difficulty of analytic FDI techniques and the OSGLR algorithm in particular is their sensitivity to modeling errors. Therefore, methods of improving the robustness of the algorithm were examined with the incorporation of age-weighting into the algorithm being the most effective approach, significantly reducing the sensitivity of the algorithm to modeling errors. The steady-state implementation of the algorithm based on a single cruise linear model was evaluated using a nonlinear simulation of a C-130 aircraft. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling the linear models used by the algorithm on dynamic pressure and flap deflection was also considered. Since simply scheduling the linear models over the entire flight envelope is unlikely to be adequate, scheduling of the steady-state implentation of the algorithm was briefly investigated.

Bonnice, W. F.↗

Small-scale rotor test rig capabilities for testing vibration alleviation algorithms

A test was conducted to assess the capabilities of a small scale rotor test rig for implementing higher harmonic control and stability augmentation algorithms. The test rig uses three high speed actuators to excite the swashplate over a range of frequencies. The actuator position signals were monitored to measure the response amplitudes at several frequencies. The ratio of response amplitude to excitation amplitude was plotted as a function of frequency. In addition to actuator performance, acceleration from six accelerometers placed on the test rig was monitored to determine whether a linear relationship exists between the harmonics of N/Rev control input and the least square error (LSE) identification technique was used to identify local and global transfer matrices for two rotor speeds at two batch sizes each. It was determined that the multicyclic control computer system interfaced very well with the rotor system and kept track of the input accelerometer signals and their phase angles. However, the current high speed actuators were found to be incapable of providing sufficient control authority at the higher excitation frequencies.

Jacklin, Stephen A.↗

Permutation codes for the state assignment of fault tolerant sequential machines

A new fault-tolerant state assignment method is suggested for synchronous sequential machines. It is assumed that the inputs are fault free and that for no input it is possible to reach all or most of the states, whose number may be fairly large. Error correcting codes for the state assignment are generated by permutations of a chosen linear code. A state assignment algorithm is developed and its computational complexity is estimated. Examples are given.

Chen, M.↗

The Wind and Temperature Spectrometer (WTS) in the Atmospheric Neutral Density Experiment (ANDE) Satellite

Miniaturization efforts in new spectrometers for ionosphere/thermosphere investigations of the ion-drifts and neutral winds and corresponding temperatures make possible very light (about 250 g) packages consuming less than 0.4 W. Previously described, our approach measures the angular and energy distributions of neutral atoms and molecules (or ions) in two perpendicular planes; using those distributions to determine the full wind vector, the temperature and the relative densities of O and N2, as required for the ANDE mission. The measurements require two separate electron impact ion sources each with its own electron beam cathode. We have developed a low-temperature thermionic emission cathode that delivers 1 mA electron current at 80 mW power, making it possible to operate neutral wind-temperature experiments for the first time with powers less than 0.5 W. Advances in the ion optics of the energy-angle spectrometer enhance the energy resolution-aperture product more than a factor of 3 to enable energy resolutions of a few percent with large apertures. With these technology improvements it is now possible to obtain the full neutral wind vector, temperature and O/N2, density ratio once per second in a 250g/0.4W package with sensitivity up to about 500 km altitude in the thermosphere. We will describe the WTS as deployed in ANDE and show simulated data with the non-linear least squares analysis to illustrate expected performance of the WTS in the estimated errors in the three components of the wind, the temperature, and the relative densities.

Herrero, F. A.↗

Orion Optical Navigation Progress Toward Exploration Mission 1

Optical navigation of human spacecraft was proposed on Gemini and implemented successfully on Apollo as a means of autonomously operating the vehicle in the event of lost communication with controllers on Earth. The Orion emergency return system utilizing optical navigation has matured in design over the last several years, and is currently undergoing the final implementation and test phase in preparation for Exploration Mission 1 (EM-1) in 2019. The software development is past its Critical Design Review, and is progressing through test and certification for human rating. The filter architecture uses a square-root-free UDU covariance factorization. Linear Covariance Analysis (LinCov) was used to analyze the measurement models and the measurement error models on a representative EM-1 trajectory. The Orion EM-1 flight camera was calibrated at the Johnson Space Center (JSC) electro-optics lab. To permanently stake the focal length of the camera a 500 mm focal length refractive collimator was used. Two Engineering Design Unit (EDU) cameras and an EDU star tracker were used for a live-sky test in Denver. In-space imagery with high-fidelity truth metadata is rare so these live-sky tests provide one of the closest real-world analogs to operational use. A hardware-in-the-loop test rig was developed in the Johnson Space Center Electro-Optics Lab to exercise the OpNav system prior to integrated testing on the Orion vehicle. The software is verified with synthetic images. Several hundred off-nominal images are also used to analyze robustness and fault detection in the software. These include effects such as stray light, excess radiation damage, and specular reflections, and are used to help verify the tuning parameters chosen for the algorithms such as earth atmosphere bias, minimum pixel intensity, and star detection thresholds.

Holt, Greg N.↗

TPSAS-NF1676L-10863-DND

One important aspect of successful climate monitoring is satellite calibration. There is at least a 25-year of operational geostationary (GEO) record available for climate studies, if properly calibrated. The Global Space-based Inter-Calibration System (GSICS) project is another effort to provide the climate community consistent calibration across multiple platforms. Also, the Clouds and the Earth's Radiant Energy System (CERES) project, provides consistent GEO retrieved cloud properties and derived broadband fluxes across multiple platforms. This year GSICS is focusing on geostationary visible channel calibration. The GSICS strategy is to use multiple approaches, such as cross-calibrating the GEO radiances against MODIS as a reference, deep convective clouds as bright stable targets, deserts, sun-glint, stars, moon and other model based calibration methods. Each of these methods is independent of each other and can assess the stability of the GEO visible instrument with differing uncertainties. This study focuses on the inter-calibration of the GEO radiances against MODIS as a reference by using collocated, and coincident ray-matched radiances. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. This presentation will focus on the technique, some error analysis, comparisons with other methods, and an approach to inter-calibrate historical GEOs before MODIS.

D R Doelling↗

Design of a Thermal Testbed for Metrology of Active Antennas

NASA mission requirements have driven an increased interest in active phased array antennas (APAA) for space-based user communication terminals. Recent advancements in 5G technology have driven down the cost of APAA development and manufacturing all while providing a technology solution that covers many existing Ka-Band satellite communication spectrum bands. While these developments have provided ample opportunities to leverage new chips and arrays for use in space, there is also a need to evaluate these antennas in a relevant environment. Active arrays, as designed for use in 5G, require thermal management to avoid damage to the device as well as to maintain performance. Measured performance under various thermal conditions is essential both for understanding overall APAA performance and ensuring operation is within required tolerances. To address these measurement needs, the SmallSat Ka-band Operations User Terminal (SKOUT) project at the NASA Glenn Research Center (GRC) developed a test environment that combines traditional antenna and communication system metrology with a conduction cooling/heating thermal control system to simulate the space thermal environment. This paper will address the metrologysystem design and performance specifications as well as test article setup and operation. Tests that are typically performed at ambient temperature can now be performed over the typical temperature range of a Low Earth Orbit (LEO) mission. These tests include error vector magnitude (EVM), gain to noise temperature (G/T), antenna patterns, and non-linear characterization. The paper will cover the configuration for each test and provide results from a recent test campaign. Results illustrate the importance of higher fidelity environmental testing when evaluating the performance of an APAA.

active phased array↗

Analytics of Radioactive Materials Released in the Fukushima Daiichi Nuclear Accident

The 2011 Fukushima Daiichi nuclear accident in Japan resulted in the release of radioactive materials into the atmosphere, the nearby sea, and the surrounding land. Following the accident, several meteorological models were used to predict the transport of the radioactive materials to other continents such as North America and Europe. Also of high importance is the dispersion of radioactive materials locally and within Japan. Based on the International Atomic Energy Agency (IAEA) Convention on Early Notification of a nuclear accident, several radiological data sets were collected on the accident by the Japanese authorities. Among the radioactive materials monitored, are I-131 and Cs-137 which form the major contributions to the contamination of drinking water. The radiation dose in the atmosphere was also measured. It is impractical to measure contamination and radiation dose in every place of interest. Therefore, modeling helps to predict contamination and radiation dose. Some modeling studies that have been reported in the literature include the simulation of transport and deposition of I-131 and Cs-137 from the accident, Cs-137 deposition and contamination of Japanese soils, and preliminary estimates of I-131 and Cs-137 discharged from the plant into the atmosphere. In this paper, we present statistical analytics of I-131 and Cs-137 with the goal of predicting gamma dose from the Fukushima Daiichi nuclear accident. The data sets used in our study were collected from the IAEA Fukushima Monitoring Database. As part of this study, we investigated several regression models to find the best algorithm for modeling the gamma dose. The modeling techniques used in our study include linear regression, principal component regression (PCR), partial least square (PLS) regression, and ridge regression. Our preliminary results on the first set of data showed that the linear regression model with one variable was the best with a root mean square error of 0.0133 μSv/h, compared to 0.0210 μSv/h for PCR, 0.231 μSv/h for ridge regression L-curve, 0.0856 μSv/h for PLS, and 0.0860 μSv/h for ridge regression cross validation. Complete results using the full datasets for these models will also be presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The dissolution behavior of borosilicate glasses in far-from equilibrium conditions

In far-from-equilibrium conditions, the dissolution of borosilicate glasses used to immobilize nuclear waste is known to be a function of both temperature and pH. The aim of this paper is to study effects of these variables on three model waste glasses (SON68, ISG, AFCI). To do this, experiments were conducted at temperatures of 23, 40, 70, and 90 °C and pH(RT) values of 9, 10, 11, and 12 with the single-pass flow-through (SPFT) test method. The results from these tests were then used to parameterize a kinetic rate model based on transition state theory. Both the absolute dissolution rates and the rate model parameters are compared with previous results. Discrepancies in the absolute dissolution rates as compared to those obtained using other test methods are discussed. Rate model parameters for the three glasses studied here are nearly equivalent within error and in relative agreement with previous studies. The results were analyzed with a linear multivariate regression (LMR) and a nonlinear multivariate regression performed with the use of the Glass Corrosion Modeling Tool (GCMT), which is capable of providing a robust uncertainty analysis. This robust analysis highlights the high degree of correlation of various parameters in the kinetic rate model. As more data are obtained on borosilicate glasses with varying compositions, the effect of glass composition on the rate parameter values could possibly be obtained. This would allow for the possibility of predicting the forward dissolution rate of glass based solely on composition

Neeway, James J.↗