Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

Plasma Waves Observed in the Cusp Turbulent Boundary Layer: An Analysis of High Time Resolution Wave and Particle Measurements from the Polar Spacecraft

The boundary layer located in the cusp and adjacent to the magnetopause is a region that is quite turbulent and abundant with waves. The Polar spacecraft's orbit and sophisticated instrumentation are ideal for studying this region of space. Our analysis of the waveform data obtained in this turbulent boundary layer shows broadband magnetic noise extending up to a few kilohertz (but less than the electron cyclotron frequency); sinusoidal bursts (a few tenths of a second) of whistler mode waves at around a few tens of hertz, a few hundreds of hertz, and just below the electron cyclotron frequency; and bipolar pulses, interpreted as electron phase-space holes. In addition, bursts of electron cyclotron harmonic waves are occasionally observed with magnetic components. We show evidence of broadband electrostatic bursts covering a range of approx. 3 to approx. 25 kHz (near but less than the plasma frequency) occurring in packets modulated at the frequency of some of the whistler mode waves. On the basis of high time resolution particle data from the Polar HYDRA instrument, we show that these bursts are consistent with generation by the resistive medium instability. The most likely source of the whistler mode waves is the magnetic reconnection site closest to the spacecraft, since the waves are observed propagating both toward and away from the Earth, are bursty, which is often the case with reconnection, and do not fit on the theoretical cold plasma dispersion relation curve.

Pickett, J. S.↗

Auroral, Ionospheric and Ground Magnetic Signatures of Magnetopause Surface Modes

Surface waves on Earth's magnetopause have a controlling effect upon global magnetospheric dynamics. Since spacecraft provide sparse in situ observation points, remote sensing these modes using ground-based instruments in the polar regions is desirable. However, many open conceptual questions on the expected signatures remain. Therefore, we provide predictions of key qualitative features expected in auroral, ionospheric, and ground magnetic observations through both magnetohydrodynamic theory and a global coupled magnetosphere-ionosphere simulation of a magnetopause surface eigenmode. These show monochromatic oscillatory field-aligned currents (FACs), due to both the surface mode and its non-resonant Alfvén coupling, are present throughout the magnetosphere. The currents peak in amplitude at the equatorward edge of the magnetopause boundary layer, not the open-closed boundary as previously thought. They also exhibit slow poleward phase motion rather than being purely evanescent. We suggest the upward FAC perturbations may result in periodic auroral brightenings. In the ionosphere, convection vortices circulate the poleward moving FAC structures. Finally, surface mode signals are predicted in the ground magnetic field, with ionospheric Hall currents rotating perturbations by approximately (but not exactly) 90° compared to the magnetosphere. Thus typical dayside magnetopause surface modes should be strongest in the East-West ground magnetic field component. Overall, all ground-based signatures of the magnetopause surface mode are predicted to have the same frequency across L-shells, amplitudes that maximize near the magnetopause's equatorward edge, and larger latitudinal scales than for field line resonance. Implications in terms of ionospheric Joule heating and geomagnetically induced currents are discussed.

M. O. Archer↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers

This paper describes the design and experimental tests of a novel neutron spin analyzer optimized for wide angle spin echo spectrometers. The new design is based on nonremanent magnetic supermirrors, which are magnetized by vertical magnetic fields created by NdFeB high field permanent magnets. The solution presented here gives stable performance at moderate costs in contrast to designs invoking remanent supermirrors. In the experimental part of this paper we demonstrate that the new design performs well in terms of polarization, transmission, and that high quality neutron spin echo spectra can be measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX central drift chamber: Design and performance

Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonuniform radiation damage in permanent magnet quadrupoles

We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL’s pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components.

36 MATERIALS SCIENCE↗

CIV VUV FPI Interferometer for Transition Region Magnetography

Much in the same way photonics harnesses light for engineering and technology applications, solar physics harnesses light for the remote sensing of the sun. In photonics the vacuum ultraviolet region offers shorter wavelength and higher energies per photon, while in solar physics the VUV allows the remote sensing of the upper levels of the solar atmosphere where magnetic fields dominate the physics. Understanding solar magnetism is a major aim for astrophysics and for understanding solar-terrestrial interaction. The poster is on our instrument development program for a high-spectral-resolution, high-finesse, Vacuum Ultraviolet Fabry-Perot Interferometer (VUV FPI) for obtaining narrow-passband images, magnetograms, and Dopplergrams of the transition region emission line of CIV (155nm). The poster will cover how the V W interferometer will allow us to understand solar magnetism, what is special about the MSFC VUV FPI, and why the University of Toronto F2 eximer has been of particular value to this program.

Gary, G. A.↗

SIDE MAGNETIC RECONNECTIONS INDUCED BY CORONAL MASS EJECTIONS: OBSERVATIONS AND SIMULATIONS

Over the last few years coronagraphic and spectroscopic observations have demonstrated that small-scale eruptions, such as 'jets', 'narrow coronal mass ejections (CMEs)', 'mini CMEs', 'streamer puffs', 'streamer detachments', and others, occur ubiquitously on the Sun. Nevertheless, the origin of small-scale eruptive events and how these are interrelated with larger scale CMEs have been poorly investigated so far. In this work, we study a series of small-scale side eruptions that occurred during and after a large-scale CME. Observations show that a CME can be associated not only with a single reconnection process, leading to the large-scale phenomenon, but also with many other side reconnections occurring at different locations and times around the main flux rope, possibly induced by the CME expansion in the surrounding corona. White light and EUV observations of a slow CME acquired by the SOHO/LASCO and SOHO/UVCS instruments are analyzed here to characterize the locations of side reconnections induced by the CME. The magnetic reconnection rate M has been estimated from the UVCS data from the ratio between the inflows and outflows observed around the reconnection region, and from the LASCO data from the observed aperture angles between the slow mode shocks (SMSs) associated with the reconnection. It turns out that M {approx_equal} 0.05 at the heliocentric distance of 1.8 R{sub sun}, while between {approx}2.5 and 5.5 R{sub sun}, M values progressively decrease with time/altitude from M {approx} 1 down to M {approx} 0.3. Such large values of M are theoretically acceptable only if flux pile-up reconnection is envisaged. The observed occurrence of multiple reconnections associated with a CME is verified by numerical simulations of an eruption occurring within multiple helmet streamers. The simulations confirm that small side reconnections are a consequence of CME expansion against the surrounding coronal streamers. The simulated and observed evolution of aperture angles between the SMSs are in good agreement as well. These results demonstrate the effect of the global coronal magnetic field in the occurrence of small-scale eruptions due to lateral reconnection in a preceding CME event.

30 DIRECT ENERGY CONVERSION↗

Highly Selective Detection of Cr{sup 3+} Ion with Colorimetric & Fluorescent Response Via Chemodosimetric Approach in Aqueous Medium

So far, very few numbers of chemosensors for Cr{sup 3+} ion have been reported. However, the main drawback of reported receptors are the lack of selectivity and other trivalent cations such as Fe{sup 3+}, Al{sup 3+} and anions like F{sup −} and {sup −}OAc frequently interfere with such assays. This paper present the synthesis, characterization & sensor studies of Schiff base containing naphthalene moiety which selectively detect Cr{sup 3+} ion by chemodosimetric approach. Using FT-IR, {sup 1}H NMR, {sup 13}C NMR and ESI mass spectroscopic techniques the probe was characterized. This receptor exhibit more selectivity and sensitivity towards Cr{sup 3+} than other divalent and trivalent cations like Mn{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Cd{sup 2+}, Cu{sup 2+}, Hg{sup 2+}, Fe{sup 3+}, and Al{sup 3+} ions. After the addition of chromium ion the receptor get change from yellow to colorless in aqueous medium. But no color change was observed on the addition of other metal ions. Using UV-Vis and PL studies, it was confirmed that the selective hydrolysis of imine group of receptor by Cr{sup 3+} ions takes place with high fluorescence enhancement that is corresponding to 1-naphthylamine. Receptor acts as selective chemodosimeter for Cr{sup 3+} ions with 2:1 stoichiometry and micro molar detection limit. This chemodosimetric approach was applied successfully for bio-imaging of HeLa cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle-ray tracing through misaligned lattice elements in accelerators

Particle-ray tracing through misaligned lattice elements can be modelled by sandwiching the transfer-map for the aligned element between two transformations, one applied at the entrance and the other at the exit of the element. Here, we derive the explicit form of these two transformations for an arbitrary misalignment using elementary geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth and magnetic property of {zeta}-phase Mn{sub 2}N{sub 1{+-}x} thin films by plasma-assisted molecular beam epitaxy

{zeta}-phase manganese nitride films were directly grown on sapphire substrates using plasma-assisted molecular beam epitaxy. Mn{sub 2}N{sub 1.06}, Mn{sub 2}N{sub 0.98}, and Mn{sub 2}N{sub 0.86} films were synthesized by controlling the temperature of the effusion cell filled with highly pure manganese powder. The composition, structure, and morphology of the films were identified by x-ray photoelectron spectroscopy, x-ray diffraction and atomic force microscopy, and the magnetic properties of the films were characterized by a superconducting quantum interference device magnetometer at 5 and 300 K. The magnetic measurements reveal that Mn{sub 2}N{sub 1{+-}x} exhibits weak ferromagnetism at 5 K, which is mainly ascribed to the weak interaction among the Mn cations induced by the nitrogen vacancies. Furthermore, the Mn{sub 2}N{sub 0.86} single-crystalline films are found to have room-temperature ferromagnetism, which is attributed to the strain of the Mn{sub 2}N{sub 0.86} films raised from lattice mismatch between the Mn{sub 2}N{sub 0.86} films and the substrates.

36 MATERIALS SCIENCE↗

Effect of Mn concentration and atomic structure on the magnetic properties of Ge thin films

This work reports on the magnetic properties of Ge{sub 100-x}Mn{sub x} (x=0-24 at. %) films prepared by cosputtering a Ge+Mn target and submitted to cumulative thermal annealing treatments up to 500 deg. C. Both as-deposited and annealed films were investigated by means of compositional analysis, Raman scattering spectroscopy, magnetic force microscopy, superconducting quantum interference device magnetometry, and electrical resistivity measurements. All as-deposited films (either pure or containing Mn) exhibit an amorphous structure, which changes to crystalline as the annealing treatments are performed at increasing temperatures. In fact, the magnetic properties of the present Ge{sub 100-x}Mn{sub x} films are very sensitive to the Mn content and whether their atomic structure is amorphous or crystalline. More specifically: whereas the amorphous Ge{sub 100-x}Mn{sub x} films (with high x) present a characteristic spin glass behavior at low temperature; after crystallization, the films (with moderate Mn contents) are ferromagnetic at room temperature. Moreover, the magnetic behavior of the films scales with their Mn concentration and tends to be more pronounced after crystallization. Finally, the semiconducting behavior of the films, experienced by previous optical studies, was confirmed through electrical measurements, which also indicate the dependence of the resistivity with the atomic composition of the films.

36 MATERIALS SCIENCE↗

Influence of Au capping layer on the magnetic properties of ultrathin epitaxial Fe{sub 3}O{sub 4}/GaAs(001) film

The effect of the Au capping layer on the magnetic anisotropies and molecular magnetic moment of ultrathin epitaxial Fe{sub 3}O{sub 4} films on GaAs(100) substrate was studied by MO Kerr effect, superconducting quantum interference device, and Ferromagnetic resonance, respectively. The films with and without capping layers show a predominant in-plane uniaxial magnetic anisotropy and a minor fourfold anisotropy. The Au capping layer was found to increase significantly the uniaxial magnetic anisotropy related to the magnetoelastic interactions at the Au/Fe{sub 3}O{sub 4} interface, and unexpectedly reduce saturation molecular magnetization due to the interfacial diffusion between Au layer and Fe{sub 3}O{sub 4} layer.

36 MATERIALS SCIENCE↗

Structural controlled magnetic anisotropy in Heusler L1{sub 0}-MnGa epitaxial thin films

Ferromagnetic L1{sub 0}-MnGa thin films have been epitaxially grown on GaN, sapphire, and MgO substrates using molecular beam epitaxy. Using diffraction techniques, the epitaxial relationships are determined. It is found that the crystalline orientation of the films differ due to the influence of the substrate. By comparing the magnetic anisotropy to the structural properties, a clear correlation could be established indicating that the in-plane and out-of-plane anisotropy is directly determined by the crystal orientation of the film and could be controlled via selection of the substrates. This result could be helpful in tailoring magnetic anisotropy in thin films for spintronic applications.

36 MATERIALS SCIENCE↗

Spin Seebeck devices using local on-chip heating

A micro-patterned spin Seebeck device is fabricated using an on-chip heater. Current is driven through a Au heater layer electrically isolated from a bilayer consisting of Fe{sub 3}O{sub 4} (insulating ferrimagnet) and a spin detector layer. It is shown that through this method it is possible to measure the longitudinal spin Seebeck effect (SSE) for small area magnetic devices, equivalent to traditional macroscopic SSE experiments. Using a lock-in detection technique, it is possible to more sensitively characterize both the SSE and the anomalous Nernst effect (ANE), as well as the inverse spin Hall effect in various spin detector materials. By using the spin detector layer as a thermometer, we can obtain a value for the temperature gradient across the device. These results are well matched to values obtained through electromagnetic/thermal modeling of the device structure and with large area spin Seebeck measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗