Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

High frequency acoustic microscopy for the determination of porosity and Young's modulus in high burnup uranium dioxide nuclear fuel

During irradiation UO{sub 2} nuclear fuel experiences the development of a non-uniform distribution of porosity which contributes to establish varying mechanical properties along the radius of the pellet. Radial variations of the porosity and of elastic properties in high burnup UO{sub 2} pellet can be investigated via high frequency acoustic microscopy. Ultrasound waves are generated by a piezoelectric transducer and focused on the sample, after having travelled through a coupling liquid. The elastic properties of the material are related to the velocity of the generated Rayleigh surface wave (VR). A 67 MWd/kgU UO{sub 2} pellet was characterized using the acoustic microscope installed in the hot cells of the Institute of Transuranium Elements: 90 MHz frequency was applied, methanol was used as coupling liquid and VR was measured at different radial positions. By comparing the porosity values obtained via acoustic microscopy with those determined using ceramographic image analysis a good agreement was found, especially in the areas close to the centre. In addition Young's modulus was calculated and its radial profile was correlated to the corresponding burnup profile. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MS–STEM–FEM: A parallelized multi-slice fluctuation TEM simulation tool

Atomic configurations of glassy or amorphous materials containing medium-range order (MRO) may be identified by comparing fluctuation transmission electron microscopy (FTEM) measurements to FTEM simulations obtained using model configurations. Candidate model sizes have traditionally been much thinner than the samples measured experimentally, and publicly available FTEM simulation software has until now omitted microscope parameters, dynamical scattering, and the phase of the diffracted electron wave. We introduce MS–STEM–FEM, an open-source software package for simulating FTEM experiments using established multi-slice TEM simulation techniques to emulate experiment more closely by incorporating microscope parameters and simulating electron scattering and propagation as a complex valued wave. Simulations using established models are compared with results of experimental STEM–FEM to validate the software. Several statistical measures of diffraction are implemented and their responses to model features are compared. Dynamical scattering is found to be less influential than the variety of crystallite orientations which occur in thicker models. Simulations of variable resolution microscopy confirm that cumulative intensity of the FTEM signal decreases with reduced model MRO and increased coherence volume. In conclusion, advantageous model scaling characteristics and efficient processor performance scaling are demonstrated, along with a study of convergence with respect to pertinent simulation parameters to identify accuracy requirements.

36 MATERIALS SCIENCE↗

Micro-CT scouting for transmission electron microscopy of human tissue specimens

Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of the mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.

60 APPLIED LIFE SCIENCES↗

The interplay of covalency, hydrogen bonding, and dispersion leads to a long range chiral network: The example of 2-butanol

The assembly of complex structures in nature is driven by an interplay between several intermolecular interactions, from strong covalent bonds to weaker dispersion forces. Understanding and ultimately controlling the self-assembly of materials requires extensive study of how these forces drive local nanoscale interactions and how larger structures evolve. Surface-based self-assembly is particularly amenable to modeling and measuring these interactions in well-defined systems. This study focuses on 2-butanol, the simplest aliphatic chiral alcohol. 2-butanol has recently been shown to have interesting properties as a chiral modifier of surface chemistry; however, its mode of action is not fully understood and a microscopic understanding of the role non-covalent interactions play in its adsorption and assembly on surfaces is lacking. In order to probe its surface properties, we employed high-resolution scanning tunneling microscopy and density functional theory (DFT) simulations. We found a surprisingly rich degree of enantiospecific adsorption, association, chiral cluster growth and ultimately long range, highly ordered chiral templating. Firstly, the chiral molecules acquire a second chiral center when adsorbed to the surface via dative bonding of one of the oxygen atom lone pairs. This interaction is controlled via the molecule’s intrinsic chiral center leading to monomers of like chirality, at both chiral centers, adsorbed on the surface. The monomers then associate into tetramers via a cyclical network of hydrogen bonds with an opposite chirality at the oxygen atom. The evolution of these square units is surprising given that the underlying surface has a hexagonal symmetry. Our DFT calculations, however, reveal that the tetramers are stable entities that are able to associate with each other by weaker van der Waals interactions and tessellate in an extended square network. This network of homochiral square pores grows to cover the whole Au(111) surface. Our data reveal that the chirality of a simple alcohol can be transferred to its surface binding geometry, drive the directionality of hydrogen-bonded networks and ultimately extended structure. Furthermore, this study provides the first microscopic insight into the surface properties of this important chiral modifier and provides a well-defined system for studying the network’s enantioselective interaction with other molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Automated Scanning Transmission Electron Microscope Guided by Sparse Data Analytics

Abstract Artificial intelligence (AI) promises to reshape scientific inquiry and enable breakthrough discoveries in areas such as energy storage, quantum computing, and biomedicine. Scanning transmission electron microscopy (STEM), a cornerstone of the study of chemical and materials systems, stands to benefit greatly from AI-driven automation. However, present barriers to low-level instrument control, as well as generalizable and interpretable feature detection, make truly automated microscopy impractical. Here, we discuss the design of a closed-loop instrument control platform guided by emerging sparse data analytics. We hypothesize that a centralized controller, informed by machine learning combining limited a priori knowledge and task-based discrimination, could drive on-the-fly experimental decision-making. This platform may unlock practical, automated analysis of a variety of material features, enabling new high-throughput and statistical studies.

47 OTHER INSTRUMENTATION↗

The relationship between local liquid density and force applied on a tip of atomic force microscope: A theoretical analysis for simple liquids

The density of a liquid is not uniform when placed on a solid. The structured liquid pushes or pulls a probe employed in atomic force microscopy, as demonstrated in a number of experimental studies. In the present study, the relation between the force on a probe and the local density of a liquid is derived based on the statistical mechanics of simple liquids. When the probe is identical to a solvent molecule, the strength of the force is shown to be proportional to the vertical gradient of ln(ρ{sub DS}) with the local liquid's density on a solid surface being ρ{sub DS}. The intrinsic liquid's density on a solid is numerically calculated and compared with the density reconstructed from the force on a probe that is identical or not identical to the solvent molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of histological sections from glass for electron microscopy - Use of Quetol 651 resin and heat

A number of approaches have been used to separate stained conventional histological sections from glass slides in preparation for a study with the electron microscope. However, in each reported case some problems were encountered with respect to the separation process. The present investigation is concerned with the use of the epoxy resin Quetol 651 as an embedding medium for this procedure, taking into account the simple application of heat (62-64 C) for performing the separation step. After the tissue has been removed from the glass by the considered technique, it is thin sectioned, and stained with uranyl acetate-lead citrate.

Kraft, L. M.↗

X-ray/EUV optics for astronomy and microscopy; Proceedings of the Meeting, San Diego, CA, Aug. 7-11, 1989

Topics included in these proceedings are on X-ray/EUV zone plates, filters, and windows; X-ray/EUV microscopes, telescopes, and monochromators; the design, characterization, and test of multilayer optics; the fabrication of X-ray/EUV multilayer optics; and the design, characterization, and test of grazing incidence X-ray optics. Other topics are on the fabrication of grazing incidence X-ray optics, X-ray/EUV space observatories and missions, the test and calibration of X-ray/EUV instruments, X-ray polarimetry, and X-ray/EUV spectroscopy and instruments. Papers are presented on 8-keV X-ray zone plates, a cylindrical X-ray multilayer monochromator, multilayer mirrors for 182 A, advanced flow polishing of exotic optical materials, and optical analysis of grazing incidence ring resonators for free-electron lasers. Attention is also given to X-ray mirrors for the European Synchrotron Radiation Facility, the XUV wide-field camera for Rosat, an optical test and alignment method for the XMM mirror module, Bragg crystal polarimeters, and a liftoff process for multilayer phase gratings.

Hoover, Richard B.↗

Structural transformation from Mn{sub 3}O{sub 4} nanorods to nanoparticles and band gap tuning via Zn doping

Highlights: Black-Right-Pointing-Pointer Successful doping of Zn in Mn{sub 3}O{sub 4} nanorod has been done by simple hydrothermal method. Black-Right-Pointing-Pointer Increase of Zn doping encouraged the formation of Mn{sub 3}O{sub 4} nanoparticle out of Mn{sub 3}O{sub 4} nanorod. Black-Right-Pointing-Pointer The energy band gap of Mn{sub 3}O{sub 4} nanorod increased continuously with the increase of Zn doping concentration. -- Abstract: Synthesis of undoped and Zn doped hausmannite Mn{sub 3}O{sub 4} nanorods was achieved through a simple hydrothermal route. Scanning electron microscopic studies showed that due to in situ Zn doping a structural deformation from Mn{sub 3}O{sub 4} nanorods to a mixture of Mn{sub 3}O{sub 4} nanorods and nanoparticles occurred. The amount of nanoparticles in the mixture increased with the increase of doping percentage. X-ray diffraction studies, transmission electron microscopy and selected area electron diffraction pattern revealed that both the nanorods and the nanoparticles were hausmannite Mn{sub 3}O{sub 4}. X-ray photoelectron spectroscopic studies confirmed successful zinc doping in Mn{sub 3}O{sub 4}. Microscopic studies revealed that the average diameters of Mn{sub 3}O{sub 4} nanorods and nanoparticles were of 200 nm and 70 nm, respectively. The possible growth mechanism and the reasons behind the formation of nanoparticles along with nanorods are discussed briefly. UV-vis spectroscopic studies showed a continuous increase in the energy bandgap of Mn{sub 3}O{sub 4} with the increase in Zn doping percentage.

36 MATERIALS SCIENCE↗

Experiments and Modeling of Evaporating/Condensing Menisci

Discuss the Constrained Vapor Bubble (CVB) experiment and how it aims to achieve a better understanding of the physics of evaporation and condensation and how they affect cooling processes in microgravity using a remotely controlled microscope and a small cooling device.

microgravity↗

CVB: The Constrained Vapor Bubble 40 mm Capillary Experiment on the ISS

Discuss the Constrained Vapor Bubble (CVB) 40mm Fin experiment on the ISS and how it aims to achieve a better understanding of the physics of evaporation and condensation and how they affect cooling processes in microgravity using a remotely controlled microscope and a small cooling device

microgravity↗

Novel Focused Ion Beam Liftouts for Spatial Characterization of Spherical Biominerals With Transmission Electron Microscopy

Abstract Focused ion beam (FIB) is frequently used to prepare electron- and X-ray-beam-transparent thin sections of samples, called lamellae. Typically, lamellae are prepared from only a subregion of a sample. In this paper, we present a novel approach for FIB lamella preparation of microscopic samples, wherein the entire cross-section of the whole sample can be investigated. The approach was demonstrated using spherical, porous, and often hollow microprecipitates of biologically precipitated calcium carbonate. The microprecipitate morphology made these biogenic samples more fragile and challenging than materials commonly investigated using FIB lamellae. Our method enables the appropriate orientation of the lamellae required for further electron/X-ray analyses after attachment to the transmission electron microscopy (TEM) grid post and facilitates more secure adhesion onto the grid post. We present evidence of autofluorescence in bacterially precipitated vaterite using this lamella preparation method coupled with TEM selected area diffraction. This innovative approach allows studying biomineralization at the micro to nano scales, which can provide novel insights into bacterial responses to microenvironmental conditions.

47 OTHER INSTRUMENTATION↗

High-speed tapping-mode atomic force microscopy using a Q-controlled regular cantilever acting as the actuator: Proof-of-principle experiments

We present the proof-of-principle experiments of a high-speed actuation method to be used in tapping-mode atomic force microscopes (AFM). In this method, we do not employ a piezotube actuator to move the tip or the sample as in conventional AFM systems, but, we utilize a Q-controlled eigenmode of a cantilever to perform the fast actuation. We show that the actuation speed can be increased even with a regular cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic-resolution visualization and doping effects of complex structures in intercalated bilayer graphene

Molecules intercalating two-dimensional materials form complex structures that have been characterized primarily by spatially averaged techniques. In this work, we use aberration-corrected scanning transmission electron microscopy and density-functional-theory (DFT) calculations to study the atomic structure of bilayer graphene (BLG) and few-layer graphene (FLG) intercalated with FeC l 3 . In BLG, we discover two distinct intercalated structures that we identify as monolayer FeC l 3 and monolayer FeC l 2 . The two structures are separated by atomically sharp boundaries and induce large free-carrier densities on the order of 10 13 c m - 2 in the graphene layers. In FLG, we observe multiple FeC l 3 layers stacked in a variety of possible configurations with respect to one another. Lastly, we find that the microscope's electron beam can convert the FeC l 3 monolayer into FeOCl monolayers in a rectangular lattice. These results reveal the need for a combination of atomically resolved microscopy, spectroscopy, and DFT calculations to identify intercalated structures and study their properties.

36 MATERIALS SCIENCE↗

Three-dimensional super line-localization in low signal-to-noise microscope images via prior-apprised unsupervised learning (PAUL)

Biological processes such as processive enzyme turnover and intracellular cargo tracking involve the dynamic motion of a small "article" along a curvilinear biopolymer track. To understand these processes that occur across multiple length and time scales, one must acquire both the trajectory of the particle and the position of the track along which it moves, possibly by combining high-resolution single-particle tracking with conventional microscopy. Yet, usually there is a significant resolution mismatch between these modalities: while the tracked particle is localized with a precision of 10 nm, the image of the surroundings is limited by optical difraction, with 200 nm lateral and 500 nm axial resolutions. Compared to the particle's trajectory, the surrounding curvilinear structure appears as a blurred and noisy image. This disparity in the spatial resolutions of the particle trajectory and the surrounding curvilinear structure image makes data reconstruction, as well as interpretation, particularly challenging. Analysis is further complicated when the curvilinear structures are oriented arbitrarily in 3D space. Here, we present a prior-apprised unsupervised learning (PAUL) approach to extract information from 3D images where the underlying features resemble a curved line such as a filament or microtubule. This three-stage framework starts with a Hessian-based feature enhancement, which is followed by feature registration, where local line segments are detected on repetitively sampled subimage tiles. In the final stage, statistical learning, segments are clustered based on their geometric relationships. Principal curves are then approximated from each segment group via statistical tools including principal component analysis, bootstrap and kernel transformation. This procedure is characterized on simulated images, where sub-voxel medium deviations from true curves have been achieved. The 3D PAUL approach has also been implemented for successful line localization in experimental 3D images of gold nanowires obtained using a multifocal microscope. Lastly, this work not only bridges the resolution gap between two microscopy modalities, but also allows us to conduct 3D super line-localization imaging experiments, without using super-resolution techniques.

42 ENGINEERING↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗