Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monitor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Toward Monitoring and Predicting Cognitive Resilience

"Toward Monitoring and Predicting Cognitive Resilience" for IWS 2023 session DS04, Monitoring Cognitive Resilience. Definitions and characterizations of Cognitive Resilience are presented, along with other considerations for monitoring and predicting it in the context of space radiation and other stressors. This session will feature “lightning-style" talks focused on how HRP research could be used in conjunction with work from interagency partnerships to monitor or predict cognitive resilience for astronauts followed by facilitated panel discussion focused on key questions.

cognition↗

Large-Scale Groundwater Monitoring in Brazil Assisted With Satellite-Based Artificial Intelligence Techniques

Here, we develop and test an artificial intelligence (AI)-based approach to monitor major Brazilian aquifers. The approach combines Gravity Recovery and Climate Experiment (GRACE) data and ground-based hydrogeological measurements from Brazil’s Integrated Groundwater Monitoring Network at hundreds of wells distributed in twelve aquifers across the country. We tested model ensembles based on three AI approaches: Extreme Gradient Boost, Light Gradient Boosting Model and CatBoost, followed by a Linear Regression (LR) step. The approach is further boosted with wavelet and seasonal decomposition processes applied to GRACE data. To determine the AI-based model’s sensitivity to data availability, we propose four experiments combining hydrogeological measurements from different aquifers. Groundwater storage estimates from the Global Land Data Assimilation System (GLDAS) are used as benchmark. A sensitivity analysis shows that the LR-based model ensemble is the best suited and to reproduce groundwater storage change in all studied Brazilian aquifers. Results show that the proposed approach outperforms GLDAS in all experiments, with an RMSE value of 2.68cm for the experiment that covers all monitored wells in Brazil. GLDAS resulted in RMSE=6.76cm. Using our AI model outputs, we quantified the groundwater storage change of two major aquifers, Urucuia and Bauru-Caiuá, over the past two decades: -31km 3 and -6km 3 , respectively. Water loss is driven by a prolonged drought across most of the country and intensification of groundwater pumping for irrigation. This study demonstrates that combining satellite data and AI can be a cost-effective alternative to monitor poorly equipped aquifers at the continental scale, with possible global replicability.

GRACE↗

AUTOMATED RADIOANALYTICAL CHEMISTRY: APPLICATIONS FOR THE LABORATORY AND INDUSTRIAL PROCESS MONITORING

The identification and quantification of targeted α- and β-emitting radionuclides via destructive analysis in complex radioactive liquid matrices is highly challenging. Analyses are typically accomplished at on- or off-site laboratories through laborious sample preparation steps and extensive chemical separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, alpha energy spectroscopy, mass spectrometry). Analytical results may take days or weeks to report. When an industrial-scale plant requires periodic or continuous monitoring of radionuclides as an indication of the composition of its feed stream, diversion of safeguarded nuclides, or of plant operational conditions (for example), radiochemical measurements should be rapid, but not at the expense of precision and accuracy. Scientists at Pacific Northwest National Laboratory have developed and characterized a host of automated radioanalytical systems designed to perform reproducible and rapid radioanalytical processes. Platforms have been assembled for 1) automation and acceleration of sample analysis in the laboratory and 2) automated monitors for monitoring industrial scale nuclear processes on-line with near-real time results. These methods have been applied to the analysis of environmental-level actinides and fission products to high-level nuclear process fluids. Systems have been designed to integrate a number of discrete sample handling steps, including sample pretreatment (e.g., digestion and valence state adjustment) and chemical separations. The systems have either utilized on-line analyte detection or have collected the purified analyte fractions for off-line measurement applications. One PNNL system of particular note is a fully automated prototype on-line radioanalytical system designed for the Waste Treatment Plant at Hanford, WA, USA. This system demonstrated nearly continuous destructive analysis of the soft β-emitting radionuclide 99Tc in nuclear tank waste feed solutions. The system is compact, fully self-calibrating, and analytical results can be immediately transmitted to on- or off-site locations. This platform exemplifies how automation can be integrated into reprocessing facilities to support the needs of international nuclear safeguards and reprocessing plant operational monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Concepts for Environmental Radioactive Air Sampling and Monitoring

Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

emissions↗

Demonstration and Performance Monitoring of Foundation Heat Exchangers (FHX) in Ultra-High Energy Efficient Research Homes

The more widespread use of Ground Source Heat Pump (GSHP) systems has been hindered by their high first cost, which is mainly driven by the cost of the drilling and excavation for installation of ground heat exchangers (GHXs). A new foundation heat exchanger (FHX) technology was proposed to reduce first cost by placing the heat exchanger into the excavations made during the course of construction (e.g., the overcut for the basement and/or foundation and run-outs for water supply and the septic field). Since they reduce or eliminate the need for additional drilling or excavation, foundation heat exchangers have the potential to significantly reduce or eliminate the first cost premium associated with GSHPs. Since December 2009, this FHX technology has been demonstrated in two ultra-high energy efficient new research houses in the Tennessee Valley, and the performance data has been closely monitored as well. This paper introduces the FHX technology with the design, construction and demonstration of the FHX and presents performance monitoring results of the FHX after one year of monitoring. The performance monitoring includes hourly maximum and minimum entering water temperature (EWT) in the FHX compared with the typical design range, temperature difference (i.e., T) across the FHX, and hourly heat transfer rate to/from the surrounding soil.

15 GEOTHERMAL ENERGY↗

Building America Case Study: Advanced Boiler Load Monitoring Controllers, Chicago, Illinois (Fact Sheet)

Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectroscopic Online Monitoring for Process Control and Safeguarding of Radiochemical Fuel Reprocessing Streams

There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the spent nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. In addition, the ability for continuous online monitoring allows for numerous benefits. This paper reviews application of the absorption and vibrational spectroscopic techniques supplemented by physicochemical measurements for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and spectrophotometric techniques for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. Both techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Static spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. Satisfactory prediction of the analytes concentrations in these preliminary experiments warrants further development of the spectroscopy-based methods for radiochemical safeguards and process control.

spectroscopic process monitoring, Pu, U, Np↗

Cybersecurity Intrusion Detection and Monitoring for Field Area Network: Final Report

This report summarizes the key technical accomplishments, industry impact and performance of the I2-CEDS grant entitled “Cybersecurity Intrusion Detection and Monitoring for Field Area Network”. Led by Applied Communication Sciences (ACS/Vencore Labs) in conjunction with its utility partner Sacramento Municipal Utility District (SMUD), the project accelerated research on a first-of-its-kind cybersecurity monitoring solution for Advanced Meter Infrastructure and Distribution Automation field networks. It advanced the technology to a validated, full-scale solution that detects anomalies, intrusion events and improves utility situational awareness and visibility. The solution was successfully transitioned and commercialized for production use as SecureSmart™ Continuous Monitoring. Discoveries made with SecureSmart™ Continuous Monitoring led to tangible and demonstrable improvements in the security posture of the US national electric infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monte Carlo Uncertainty Quantification for an Unattended Enrichment Monitor

As a case study for uncertainty analysis, we consider a model flow monitor for measuring enrichment in gas centrifuge enrichment plants (GCEPs) that could provide continuous monitoring of all declared gas flow and provide high-accuracy gas enrichment estimates as a function of time. The monitor system could include NaI(Tl) gamma-ray spectrometers, a pressure signal-sharing device to be installed on an operator\rq{}s pressure gauge or a dedicated inspector pressure sensor, and temperature sensors attached to the outside of the header pipe, to provide pressure, temperature, and gamma-ray spectra measurements of UF$_6$ gas flow through unit header pipes. Our study builds on previous modeling and analysis methods development for enrichment monitor concepts and a software tool that was developed at Oak Ridge National Laboratory to generate and analyze synthetic data.

international safeguards↗

Advances in Online Monitoring for Measurement within Nuclear Fuel Reprocessing Streams

Abstract – Significant effort has been focused on the back end of the nuclear fuel cycle including treatment and reuse of irradiated fuel. Solvent extraction reprocessing methods that have been developed often contain various steps, with each one tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper describes the application of the electronic and vibrational spectroscopic techniques for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and UV-vis spectroscopic techniques for online real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(VI/IV)/Np(VI/V/IV)/Nd(III) in solutions relevant to used nuclear fuel reprocessing. These techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved used fuel solutions. Currently this has been demonstrated on the macroscopic scale, using sample probes requiring large solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 µL or less, which is a scale reduction of over 1,000 fold in sample size. This will significantly reduce the requirements for handling hazardous materials, and greatly reduce the costs associated with worker protection from exposure to radioactive and hazardous materials, and costs due to waste disposal.

process monitoring, U, nitric acid, microfluidic, ↗

Long-Term Environmental Monitoring of an Operating Deep Geologic Nuclear Waste Repository

In the present energy dilemma in which we find ourselves, the magnitude of humanity's energy needs requires that we embrace a multitude of various energy sources and applications. Nuclear energy must be a major portion of the distribution. One often-cited strategic hurdle to the commercial production of nuclear energy is the apparent lack of an acceptable nuclear waste repository. This issue has been quietly addressed at the U. S. Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP; see http://www.wipp.energy.gov), the closest population center of significant size being Carlsbad, New Mexico. WIPP has been operating for about nine years, disposing of over 250,000 drum-equivalents of nuclear waste. From the standpoint of addressing operational and environmental risk, as well as public fear, WIPP has had extensive human health and environmental monitoring. The Carlsbad Environmental Monitoring and Research Center is in the Institute for Energy and the Environment, in the College of Engineering at New Mexico State University. Located in Carlsbad, NM, CEMRC has been the independent monitoring facility for the area around WIPP from 1993 to the present, i.e., from six years before disposal operations began to nine years of waste disposal operations (www.cemcr.org). Based on the radiological analyses of monitoring samples completed to date for area residents and site workers, and for selected aerosols, soils, sediments, drinking water and surface waters, there is no evidence of increases in radiological contaminants in the region of WIPP that could be attributed to releases from WIPP. Levels of radiological and non-radiological analytes measured since operations began in 1999 have been within the range of baseline levels measured previously, and are within the ranges measured by other entities at the State and local levels since well before disposal phase operations began in 1999. (authors)

54 ENVIRONMENTAL SCIENCES↗

Simulation and Optimization of Large Scale Subsurface Environmental Impacts; Investigations, Remedial Design and Long Term Monitoring

The global impact to human health and the environment from large scale chemical / radionuclide releases is well documented. Examples are the wide spread release of radionuclides from the Chernobyl nuclear reactors, the mobilization of arsenic in Bangladesh, the formation of Environmental Protection Agencies in the United States, Canada and Europe, and the like. The fiscal costs of addressing and remediating these issues on a global scale are astronomical, but then so are the fiscal and human health costs of ignoring them. An integrated methodology for optimizing the response(s) to these issues is needed. This work addresses development of optimal policy design for large scale, complex, environmental issues. It discusses the development, capabilities, and application of a hybrid system of algorithms that optimizes the environmental response. It is important to note that 'optimization' does not singularly refer to cost minimization, but to the effective and efficient balance of cost, performance, risk, management, and societal priorities along with uncertainty analysis. This tool integrates all of these elements into a single decision framework. It provides a consistent approach to designing optimal solutions that are tractable, traceable, and defensible. The system is modular and scalable. It can be applied either as individual components or in total. By developing the approach in a complex systems framework, a solution methodology represents a significant improvement over the non-optimal 'trial and error' approach to environmental response(s). Subsurface environmental processes are represented by linear and non-linear, elliptic and parabolic equations. The state equations solved using numerical methods include multi-phase flow (water, soil gas, NAPL), and multicomponent transport (radionuclides, heavy metals, volatile organics, explosives, etc.). Genetic programming is used to generate the simulators either when simulation models do not exist, or to extend the accuracy of them. The uncertainty and sparse nature of information in earth science simulations necessitate stochastic representations. For discussion purposes, the solution to these site-wide challenges is divided into three sub-components; plume finding, long term monitoring, and site-wide remediation. Plume finding is the optimal estimation of the plume fringe(s) at a specified time. It is optimized by fusing geo-stochastic flow and transport simulations with the information content of data using a Kalman filter. The result is an optimal monitoring sensor network; the decision variable is location(s) of sensor in three dimensions. Long term monitoring extends this approach concept, and integrates the spatial-time correlations to optimize the decision variables of where to sample and when to sample over the project life cycle. Optimization of location and timing of samples to meet the desired accuracy of temporal plume movement is accomplished using enumeration or genetic algorithms. The remediation optimization solves the multi-component, multiphase system of equations and incorporates constraints on life-cycle costs, maximum annual costs, maximum allowable annual discharge (for assessing the monitored natural attenuation solution) and constraints on where remedial system component(s) can be located, including management overrides to force certain solutions to be chosen are incorporated for solution design. It uses a suite of optimization techniques, including the outer approximation method, Lipchitz global optimization, genetic algorithms, and the like. The automated optimal remedial design algorithm requires a stable simulator be available for the simulated process. This is commonly the case for all above specifications sans true three-dimensional multiphase flow. Much work is currently being conducted in the industry to develop stable 3D, three-phase simulators. If needed, an interim heuristic algorithm is available to get close to optimal for these conditions. This system process provides the full capability to optimize multi-source, multiphase, and multicomponent sites. The results of applying just components of these algorithms have produced predicted savings of as much as $90,000,000(US), when compared to alternative solutions. Investment in a pilot program to test the model saved 100% of the $20,000,000 predicted for the smaller test implementation. This was done without loss of effectiveness, and received an award from the Vice President - and now Nobel peace prize winner - Al Gore of the United States. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Testing of a Solid-Liquid Interface Monitor for High-Level Waste Tanks

A high-level waste (HLW) monitor has been designed, fabricated and tested at full-scale for deployment inside a Hanford tank. The Solid-Liquid Interface Monitor (SLIM) integrates a commercial sonar system with a mechanical deployment system for deploying into an underground waste tank. The system has undergone several design modifications based upon changing requirements at Hanford. We will present the various designs of the monitor from first to last and will present performance data from the various prototype systems. We will also present modeling of stresses in the enclosure under 85 mph wind loading. The system must be able to function at winds up to 15 mph and must withstand a maximum loading of 85 mph. There will be several examples presented of engineering tradeoffs made as FIU analyzed new requirements and modified the design to accommodate. We will present our current plans for installing into the Cold Test Facility at Hanford and into a double-shelled tank at Hanford. Finally, we will present our vision for how this technology can be used at Hanford and Savannah River Site to improve the filling and emptying of high-level waste tanks. In conclusion: 1. The manually operated first-generation SLIM is a viable option on tanks where personnel are allowed to work on top of the tank. 2. The remote controlled second-generation SLIM can be utilized on tanks where personnel access is limited. 3. The totally enclosed fourth-generation SLIM, when the design is finalized, can be used when the possibility exists for wind dispersion of any HLW that maybe on the system. 4. The profiling sonar can be used effectively for real-time monitoring of the solid-liquid interface over a large area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring and evaluation of green public procurement programs

Effective procurement policies can help governments save considerable amounts of money while also reducing energy consumption. Additionally, private sector companies which purchase large numbers of energy-consuming devices can benefit from procurement policies that minimize life-cycle energy costs. Both public and private procurement programs offer opportunities to generate market-transforming demand for energy efficient appliances and lighting fixtures. In recent years, several governments have implemented policies to procure energy efficient products and services. When deploying these policies, efforts have focused on developing resources for implementation (guidelines, energy efficiency specifications for tenders, life cycle costing tools, training, etc.) rather than defining monitoring systems to track progress against the set objectives. Implementation resources are necessary to make effective policies; however, developing Monitoring and Evaluation (M and E) mechanisms are critical to ensure that the policies are effective. The purpose of this article is to provide policy makers and procurement officials with a preliminary map of existing approaches and key components to monitor Energy Efficient Procurement (EEP) programs in order to contribute to the improvement of their own systems. Case studies are used throughout the paper to illustrate promising approaches to improve the M and E of EEP programs, from the definition of the system or data collection to complementary instruments to improve both the monitoring response and program results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strategy for Long-Term Stewardship and Monitoring of Amchitka Island - 12190

The Long-Term Surveillance and Maintenance Plan (LTSMP) for Amchitka details how the U.S. Department of Energy (DOE) intends to fulfill its mission to maintain protection of human health and the environment at and around the sites on Amchitka Island. The LTSMP calls for monitoring to be performed every 5 years, at least in the initial phase of the project. The purpose of the monitoring is to develop a baseline of activity concentrations for selected radionuclides in biota, water, and soil, both on Amchitka and at the reference location on Adak Island, approximately 322 km (200 miles) northeast of Amchitka. Data compiled by the Consortium for Risk Evaluation with Stakeholder Participation (CRESP, 2006) are being included as part of the baseline data set. The specific biological, water, and sediment samples collected during the 2011 sampling event were developed through close coordination with the primary stakeholders, including the Alaska Department of Environmental Conservation, the Aleutian Pribilof Island Association, and the U.S. Fish and Wildlife Service (USFWS). Amchitka is managed by the USFWS as part of the Alaska Maritime National Wildlife Refuge. Two plans were developed to address specific needs of the biological- and the terrestrial-monitoring programs. Results from these monitoring programs will help determine whether the environment is being impacted by radionuclide migration and uptake, and if subsistence and commercial-catch seafood is safe for human consumption. The RESRAD-BIOTA code is being used to evaluate ecological health relative to the radionuclide levels determined from this sampling event. The samples were sent to three laboratories for analysis. With the exception of the seawater samples, most of the samples were sent to the Center for Accelerator Mass Spectrometry at the Lawrence Livermore National Laboratory. A smaller subset of rock-weed samples, Star reindeer lichen samples, and soil samples collected from beneath the lichen were sent to UAF for cesium-137 analysis. Marine sediment samples were also collected and sent to UAF for testing. The seawater samples were sent to the University of Miami Tritium Laboratory for enriched tritium analysis. Results from the seawater samples for tritium were received in September 2011. Results from the 2011 sampling are expected to be available on the LM web site in 2012. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron Monitoring Systems for the Characterisation of Nuclear Fuel and Waste - Methodology and Applications - 12055

The most characteristic behaviour of nuclear fuel or waste contaminated by fission material or isotopes resulting from fissile processes is the emission of neutrons. At the same time because of the high penetration of the material by neutrons, they are an ideal probe for measurement by non-destructive assay. The detection and data analysis in this case is quite different compared to methods using gamma measuring techniques. Neutron detection monitors have been in routine operation for a long time, showing their excellent detection capabilities. The neutron monitors designed for different applications have demonstrated their capabilities during daily operation in the field of burned up fuel elements and for nuclear waste with alpha activity. Lately the data analysis was refined and the quality of the results was improved by using MCNP calculations. Last but not least the layout and the calibration of neutron monitors are nowadays unfeasible without support by MCNP simulations. In the field of non-destructive assay the neutron monitors are undisputed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring the Long-Term Safety Performance of a Repository for Used Nuclear Fuel - 12294

The nuclear waste management programs of several nations include plans for the design, construction and operation of deep geological repositories. Some of these programs have initiated the licensing process for their repository designs. Monitoring strategies and systems are at different levels of development in each program and there is common ground with respect to the ultimate goal of the monitoring function. In this context, the primary functions of a monitoring system are considered to be the verification of safety performance and making available information that may be required for implementation of future decisions such as the timing of repository decommissioning and closure or the possible retrieval of waste containers. This study examines some of the relevant issues and outlines a conceptual monitoring system for further study and development during implementation of Adaptive Phased Management, the method selected by the Government of Canada for long-term management of used nuclear fuel. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗