Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Computing the Properties of Matter with Leadership Computing Resources (Closeout Report for DE-SC0018121)

In order to add more capabilities to Halide, we have designed a new framework called Tiramisu and integrated this framework into Halide. Since Tiramisu enables Halide to target heterogeneous architectures, our development efforts have been refocused on Tiramisu. Most high-performance computer systems today are complex and increasingly heterogeneous; they may have CPUs, GPUs and FPGAs. Achieving best performance requires taking full advantage of all these different architectures. To address this issue, we have designed Tiramisu, an optimization framework that enables Halide (and other DSLs) to target heterogeneous architectures. Tiramisu is an optimization framework that takes as input a high level, architecture-independent representation of code and a set of scheduling and data mapping commands that guide code transformation. The input can either be generated by a domain-specific language (DSL) compiler such as Halide or directly written by a programmer. Tiramisu then applies the user-specified code and data-layout transformations and generates an architecture-specific, low-level intermediate representation (IR) that takes advantage of modern architectural features such as multicore parallelism, non-uniform memory (NUMA) hierarchies, clusters, and accelerators like GPUs and FPGAs. We integrated Tiramisu within Halide and implemented a representative set of benchmarks to evaluate this integration. Tiramisu is now open source and is available for public use (http://tiramisu-compiler.org/). A paper about Tiramisu was published, it shows that Tiramisu extends Halide with many new capabilities and that Tiramisu can generate efficient code for multicores, GPUs, FPGAs and distributed heterogeneous systems. The performance of code generated by the Tiramisu backends matches or exceeds hand optimized reference implementations. For example, the multicore backend matches the highly optimized Intel MKL library on many kernels and shows speedups reaching 4x over the original Halide. In addition to making Tiramisu more robust, we have used Tiramisu to implement a set of representative tensor operation for constructing baryon building blocks required for multi baryon contractions in LQCD. In order to implement this code, we needed to generalize Tiramisu in two ways: first we needed to support indirect array accesses, and second, we needed to add support for complex numbers to Tiramisu. The code generated by Tiramisu is 6x faster than the reference code. Our efforts towards an MPI based multi-node version of tiramisu have matured and the resulting code scales well on multiple nodes (tests up to 512 KNL nodes have been undertaken).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D high-content screening for the identification of compounds that target cells in dormant tumor spheroid regions

Cancer cells in poorly vascularized tumor regions need to adapt to an unfavorable metabolic microenvironment. As distance from supplying blood vessels increases, oxygen and nutrient concentrations decrease and cancer cells react by stopping cell cycle progression and becoming dormant. As cytostatic drugs mainly target proliferating cells, cancer cell dormancy is considered as a major resistance mechanism to this class of anti-cancer drugs. Therefore, substances that target cancer cells in poorly vascularized tumor regions have the potential to enhance cytostatic-based chemotherapy of solid tumors. With three-dimensional growth conditions, multicellular tumor spheroids (MCTS) reproduce several parameters of the tumor microenvironment, including oxygen and nutrient gradients as well as the development of dormant tumor regions. We here report the setup of a 3D cell culture compatible high-content screening system and the identification of nine substances from two commercially available drug libraries that specifically target cells in inner MCTS core regions, while cells in outer MCTS regions or in 2D cell culture remain unaffected. We elucidated the mode of action of the identified compounds as inhibitors of the respiratory chain and show that induction of cell death in inner MCTS core regions critically depends on extracellular glucose concentrations. Finally, combinational treatment with cytostatics showed increased induction of cell death in MCTS. The data presented here shows for the first time a high-content based screening setup on 3D tumor spheroids for the identification of substances that specifically induce cell death in inner tumor spheroid core regions. This validates the approach to use 3D cell culture screening systems to identify substances that would not be detectable by 2D based screening in otherwise similar culture conditions. - Highlights: • Establishment of a novel method for 3D cell culture based high-content screening. • First reported high-content screen for the identification of compounds that target cells in dormant tumor spheroid regions. • Metabolite profiling by NMR spectroscopy on 3D tumor spheroids. • Identification of respiratory chain inhibitors to specifically induce cell death in inner tumor spheroid regions. • Respiratory chain inhibitors enhance cytostatic based therapy in vitro.

60 APPLIED LIFE SCIENCES↗

MPACT 4.4 Theory Manual

MPACT is a three-dimensional (3D) full-core neutron transport code capable of calculating subpin power distributions. Calculations are based on the Boltzmann transport equation for neutron fluxes for problems in which the detailed geometrical configuration of fuel components such as the pellet and cladding are explicitly retained. The cross-section data needed for the neutron transport calculation are obtained directly from a multigroup cross section library, which has traditionally been used by lattice physics codes to generate few-group homogenized cross sections for nodal core simulators. Hence, MPACT assumes neither a priori homogenization nor group condensation for the full core spatial solution. The 3D MPACT transport solution can be obtained using the method of characteristics (MOC), which employs discrete ray tracing within each fuel pin. However, for practical reactor applications, the direct application of MOC to 3D core configurations requires an excessive amount of memory and computing time due to the very large number of rays. For practical 3D full-core calculations, MPACT commonly uses an approximate “2D/1D” method that treats the radial (x and y) variables differently from the axial (z) variable. In particular, the radial dependence of the solution is calculated using transport theory, and the axial dependence is calculated using diffusion or P 3 theory. The 2D/1D method requires the core to be divided into a vertical stack of axial slices with a thickness of Δ z ≈ 5–10 cm. Each axial slice is divided radially into coarse spatial cells with boundaries that usually constitute the pin cell boundaries, for which Δ x = Δ y ≈ 1.5 cm. Then, each coarse radial cell (pin cell) is divided into 50–100 fine radial cells, which resolve the angular flux in the fuel, cladding, and moderator regions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fission Product Yield Modeling and Evaluation

Although independent and cumulative fission product yields have been a part of evaluated libraries for decades, there have been few updates over the years. The fission product yield sub-library in the ENDF/B-VIII.0 library is still largely based on the evaluation of England and Rider from the mid-90’s, with only more recent updates to the energy dependence of 239 Pu below 2 MeV and fixes to isomeric states and missing fission products. Over the past several years, there have been a wealth of new measurements of independent and cumulative fission product yields, particularly those with short half-lives, and there have been significant improvements in the modeling of prompt and delayed fission observables. Here, we describe recent progress in the improvement of fission product yield calculations, using the BeoH code and the underlying Hauser Fesh-bach Fission Fragment Decay (HF 3 D) model, developed at Los Alamos National Laboratory. We will describe our recent calculations for consistent prompt and delayed fission observables for major and minor actinides, including new work investigating isomeric ratios. We will detail the ongoing evaluation process for energy-dependent fission product yields from thermal up to 20 MeV incident neutron energy and some validation work that has been performed for these new fission product yield calculations. Additionally, we will discuss future perspectives of this work, highlighting the need for additional data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Discovery of AMPX Thermal Scattering Law Processing Issue for Solid Moderators

The 2020 edition of The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook includes a newly produced plastic-moderated evaluation, identified as PU-MET-MIXED-002 and referred to as PMM002. The 2021 edition should include another new plastic-moderated experiment, HEU-MET-THERM-004, referred to as HMT-004. These evaluations are of particular interest, as PMM-002 is moderated with polyethylene, and HMT-004 is moderated with polymethyl methacrylate (Lucite), allowing for investigation of the differences in the thermal scattering laws (TSLs) available for these materials. ENDF/B-VIII.0 includes newly produced data for 1 H-based scattering materials, including Lucite and yttrium hydride. Other available 1 H TSLs include polyethylene, light water, zirconium hydride. The unbound 1 H (free-gas) cross sections were also used. ENDF/B-VIII.0 also includes revisions made to the ENDF/B-VII.1 light water and polyethylene evaluations. Zirconium hydride was unchanged from ENDF/B-VII.1. As of this writing, there are no benchmarks included in the Verified, Archived Library of Inputs and Data (VALID) that are primarily moderated with any solid moderator, so validation that includes the PMM-002 and HMT-004 evaluations would expand the coverage to two new moderators. A study was undertaken at Oak Ridge National Laboratory with two purposes: to provide validation data based on systems that are primarily moderated with polyethylene and Lucite, and to demonstrate the reactivity changes that can result from use of different 1 H TSLs in these plastic-moderated systems. The first objective was mainly to test data and code for SCALE and AMPX, whereas the second objective was to provide useful data for practitioners on the potential variability of predicted $k_{eff}$ based on TSL changes. The use of an exactly correct TSL is often not possible given the materials involved (e.g., lubricants), but this study was intended to provide some indication of the magnitude of the changes among similar materials that can manifest through application of different TSLs in hydrogenous systems over a range of different neutron energy spectra. Unfortunately, the nominal $k_{eff}$ results exposed deviations between SCALE and Monte Carlo N-Particle (MCNP). Some of the results using different TSLs were also unexpected and difficult to explain. An investigation revealed a processing issue in AMPX that was caused by an ambiguous description of the data for incoherent elastic scattering in the ENDF manual. This issue is discussed in detail in a SCALE User Notification, and it affects some solid moderators, but it does not apply to 1 H bound in water. This issue highlights the importance of validating all TSLs used in safety analysis calculations. The remainder of this paper provides a more detailed examination of the results that triggered the investigation and a summary of the findings of that investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose Conformal Radiotherapy Reduces Prostate Cancer-Specific Mortality: Results of a Meta-analysis

Purpose: To determine in a meta-analysis whether prostate cancer-specific mortality (PCSM), biochemical or clinical failure (BCF), and overall mortality (OM) in men with localized prostate cancer treated with conformal high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT). Methods and Materials: The MEDLINE, Embase, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing conformal HDRT with CDRT for localized prostate cancer. Results: Five randomized, controlled trials (2508 patients) that met the study criteria were identified. Pooled results from these randomized, controlled trials showed a significant reduction in the incidence of PCSM and BCF rates at 5 years in patients treated with HDRT (p = 0.04 and p < 0.0001, respectively), with an absolute risk reduction (ARR) of PCSM and BCF at 5 years of 1.7% and 12.6%, respectively. Two trials evaluated PCSM with 10 years of follow up. The pooled results from these trials showed a statistical benefit for HDRT in terms of PCSM (p = 0.03). In the subgroup analysis, trials that used androgen deprivation therapy (ADT) showed an ARR for BCF of 12.9% (number needed to treat = 7.7, p < 0.00001), whereas trials without ADT had an ARR of 13.6% (number needed to treat = 7, p < 0.00001). There was no difference in the OM rate at 5 and 10 years (p = 0.99 and p = 0.11, respectively) between the groups receiving HDRT and CDRT. Conclusions: This meta-analysis is the first study to show that HDRT is superior to CDRT in preventing disease progression and prostate cancer-specific death in trials that used conformational technique to increase the total dose. Despite the limitations of our study in evaluating the role of ADT and HDRT, our data show no benefit for HDRT arms in terms of BCF in trials with or without ADT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

STAR Data Production Workflow on HPC: Lessons Learned & Best Practices

The Solenoidal Tracker at RHIC (STAR) is a multi-national supported experiment located at Brookhaven National Lab. The raw physics data captured from the detector is on the order of tens of PBytes per data acquisition campaign, which makes STAR fit well within the definition of a big data science experiment. The production of the data has typically run on standard nodes or on standard Grid computing environments. All embedding simulations (complex workflow mixing real and simulated events) have been run on standard Linux resources at the National Energy Research Scientific Computing Center (NERSC) aka PDSF. However, HPC resources such as Cori have become available for STAR's data production as well as embedding, and STAR has been the very first experiment to show feasibility of running a sustainable data production campaign on this computing resource. The use of Docker containers with Shifter is required to run on HPC @ NERSC - this approach encapsulates the environment in which a standard STAR workflow runs. From the deployment of a tailored Scientific Linux environment (requiring many of its own libraries and special configurations required to run) to the deployment of third-party software and the STAR specific software stack, it has become impractical to rely on a set of containers containing each specific software release. To this extent, solutions based on the CERN VM File System (CVMFS) for the deployment of software and services have been employed in HENP, but one needs to make careful scalability considerations when using a resource like Cori, such as not allowing all software to be deployed in containers or bare node. Additionally, CVMFS clients are not compatible on Cori nodes and one needs to rely on an indirect NFS/DVS mount scheme. In our contribution, we will discuss our strategies from the past and our current solution based on CVMFS. Furthermore, running on HPC is not a simple task as each aspect of the workflow must be enabled to scale, run efficiently, and the workflow needs to fit within the boundaries of the provided queue system (SLURM in this case). Lastly, we will also discuss what we have learned so far about what is the best method for grouping jobs to maximize a single 48 core HPC node within a specific time frame and maximize our workflow efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operational Reactor Depletion Analysis Capability

The milestone for the operational reactor depletion demonstrates a cycle depletion simulation of Watt's Bar Unit 1 Cycle 1. The simulation was performed using the VERA-CS components MPACT and COBRA-TF. The simulation was performed on the Titan and Eos machines at the Oak Ridge Leadership Computing Facility. The simulation results include the critical boron concentration, the pin resolved power, temperature, and fluid density distributions, and detector responses as a function of time. These results are presented and the critical boron concentration is compared with measured data. The comparison is reasonable given the modeling approximation used at this point. Several suggestions, both near and longer term, are given for areas of future work which include improving the methods, data, models, and computational performance. For those solution results which are not compared to measurement, e.g. power and temperature distributions, their behavior coincides with analysts' expectations. An important next step in the validation of VERA-CS will be the comparison of the computational results to the measured flux data. To satisfy this L1 milestone, numerous capabilities were successfully added as a part of supporting L2 and L3 milestones. These include: full core depletion, generation of a new cross section library, coupling of neutronics and thermal hydraulic feedback, and detector response modeling. In addition to the operational reactor depletion, several 2-D core parametric studies were performed to assess the new simulation capability and to develop guidelines on model approximations and discretizations. Some of the conclusions from these studies are: • The simulation of B-10 depletion in the coolant is necessary to accurately predict critical boron concentrations, • If the end of cycle state is of primary interest in the simulation, then significant approximations may be made in the cycle history. The ability to make use of this approximation without a notable loss in accuracy will considerably accelerate multi-cycle analysis, • The new 47-group cross section library with a transport correction of the P 0 scattering can provide solutions very efficiently and which are nearly as accurate as solutions generated with explicit P 2 scattering, and • Simplified modeling of the equilibrium xenon concentration is well predicted by the existing depletion solver, and only in certain circumstances (e.g. large and "instantaneous" changes to rod position or T/H conditions) would an explicit physical model need to be included. Overall the milestone is considered a success as the objectives were met and several new and important results were produced from this work. The results and conclusions of this milestone will continue to guide future work and become the basis for addressing the CASL Challenge Problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI

Purpose: Four-dimensional computed tomography-magnetic resonance imaging (4DCT-MRI) is an image-processing technique for simulating many 4DCT data sets from a static reference CT and motions extracted from 4DMRI studies performed using either volunteers or patients. In this work, different motion extraction approaches were tested using 6 liver cases, and a detailed comparison between 4DCT-MRI and 4DCT was performed. Methods and Materials: 4DCT-MRI has been generated using 2 approaches. The first approach used motion extracted from 4DMRI as being “most similar” to that of 4DCT from the same patient (subject-specific), and the second approach used the most similar motion obtained from a motion library derived from 4DMRI liver studies of 13 healthy volunteers (population-based). The resulting 4DCT-MRI and 4DCTs were compared using scanned proton 4D dose calculations (4DDC). Results: Dosimetric analysis showed that 93% ± 8% of points inside the clinical target volume (CTV) agreed between 4DCT and subject-specific 4DCT-MRI (gamma analysis: 3%/3 mm). The population-based approach however showed lower dosimetric agreement with only 79% ± 14% points in the CTV reaching the 3%/3 mm criteria. Conclusions: 4D CT-MRI extends the capabilities of motion modeling for dose calculations by accounting for realistic and variable motion patterns, which can be directly employed in clinical research studies. We have found that the subject-specific liver modeling appears more accurate than the population-based approach. The former is particularly interesting for clinical applications, such as improved target delineation and 4D dose reconstruction for patient-specific QA to allow for inter- and/or intra-fractional plan corrections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Improved Simple Corner Balance Method and Efforts to Enhance its Computational Performance

The diamond difference (DD) spatial discretization has long been a work horse of the neutron transport community. For nearly as long as DD has been used in neutron transport, it has been observed that DD produces undamped, non-physical angular fluxes in spatially under resolved problems and can fail in the thick diffusion limit. A long list of alternative spatial discretizations, all with better physics properties: accuracy, robustness, and/or preservation of the thick diffusion limit, have been proposed as alternatives to DD. Unfortunately, these alternative spatial discretizations also require significantly more floating point operations (FLOPs) per unknown compared to DD. Historically, neutron transport problems of interest have been able to be resolved sufficiently that DD is accurate enough and FLOPs have been the computational performance bottleneck controlling time to solution. Thus, in practice DD has been and remains a preferred spatial discretization for neutron transport simulations. Trends in computing architecture are leading to a new paradigm where data movement, not FLOPs will control time to solution. This presents an opportunity to improve neutron transport physics by reconsidering more FLOP intensive spatial discretization than DD without incurring a time to solution penalty. In this work, we consider the improved simple corner balance (ISCB) spatial discretization, a unique alternative to DD that has the same memory footprint as DD, and detail efforts to improve its computational performance. The ISCB spatial discretization is a more FLOP intensive spatial discretization than DD with the same memory footprint as DD. Though designed to maximize FLOP intensity, third party libraries such as LAPACK are not tuned for the unique, frequent, small linear algebra needs of neutron transport problems. While hand coding a sparse Gauss elimination is likely to be faster than a dense matrix solve (CM vs. HGE), were LAPACK suitable for small linear algebra problems, we would not have seen a performance increase with decreased numbers of LAPACK calls for the Schur complement solve (SC4 vs. SC1). Significant effort has reduced the relative compute time of ISCB to DD, but on current computer architectures DD is still faster than ISCB. Future work comparing the overall efficiency of ISCB to DD may reveal that while ISCB is slower than DD on current computers, ISCB is more accurate than DD by a factor greater than the compute time slowdown. As new computer architectures become available, we will test our hypothesis that neutron transport simulations will be bandwidth limited, ideally rendering the additional FLOPs required by ISCB to be 'free' [in terms of time to solution]. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SG50 Data-format Specifications Document for the Automatically Readable, Comprehensive, and Curated Experimental Reaction Database MEDUSAL

The aim of this document is to lay out a first draft of the specifications for the MEDUSAL database (Machine-readable Experimental Data User App & Library) that is being described by OECD/NEA/WPEC SG-50. The EXFOR database (Otuka et al., 2014) has a format that is based on code-value pairs, and a significant portion of the information in the EXFOR entry is contained in free text sections. Several high-level requirements for the MEDUSAL database, as laid out in the Use Cases and Requirements Working Paper (citation), relate to the definition of the specifications

Nuclear Criticality Safety Program (NCSP)↗

Prevention of Gynecomastia and Breast Pain Caused by Androgen Deprivation Therapy in Prostate Cancer: Tamoxifen or Radiotherapy?

Purpose: To determine, in a meta-analysis, whether gynecomastia and breast pain rates in men with prostate cancer treated with androgen deprivation therapy (ADT) are reduced if treated with prophylactic radiotherapy (RT) or tamoxifen (TMX). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing RT or TMX with observation for men with prostate cancer using ADT. Results: Six RCTs (three RT trials and three TMX trials, N = 777 patients total) were identified that met the study criteria. Pooled results from these RCTs comparing RT vs. observation showed a significant reduction in the incidence of gynecomastia and breast pain rates in patients treated with RT (odds ratio [OR] = 0.21, 95% confidence interval [CI] = 0.12-0.37, p < 0.0001, and OR = 0.34, 95% CI 0.20-0.57, p < 0.0001, respectively). Use of RT resulted in an absolute risk reduction (ARR) of 29.4% and 19.9%, with a number needed to treat (NNT) of 3.4 and 5 to avoid one case of gynecomastia and breast pain, respectively. Pooled results from trials comparing TMX vs. observation showed a statistical benefit for breast pain and gynecomastia in favor of TMX arms (OR = 0.04, 95% CI = 0.02-0.08, p < 0.0001 and OR = 0.07, 95% CI = 0.0-0.14, p < 0.00001). TMX resulted in an ARR = 64.1% and 47.6%, with an NNT of 1.56 and 2.1 to avoid one case of gynecomastia and breast pain, respectively. Considering adverse effects, TMX was 6 times more adverse effects than RT. Conclusions: Our data have shown that both TMX and RT prevented gynecomastia and breast pain in patients with prostate cancer receiving ADT for prostate cancer. Although TMX was two times more effective in preventing gynecomastia, RT should represent an effective and safe treatment option, to take into account mainly in patients with cardiovascular risk factors or thrombotic diathesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliative Radiotherapy for Bone Metastases: An ASTRO Evidence-Based Guideline

Purpose: To present guidance for patients and physicians regarding the use of radiotherapy in the treatment of bone metastases according to current published evidence and complemented by expert opinion. Methods and Materials: A systematic search of the National Library of Medicine's PubMed database between 1998 and 2009 yielded 4,287 candidate original research articles potentially applicable to radiotherapy for bone metastases. A Task Force composed of all authors synthesized the published evidence and reached a consensus regarding the recommendations contained herein. Results: The Task Force concluded that external beam radiotherapy continues to be the mainstay for the treatment of pain and/or prevention of the morbidity caused by bone metastases. Various fractionation schedules can provide significant palliation of symptoms and/or prevent the morbidity of bone metastases. The evidence for the safety and efficacy of repeat treatment to previously irradiated areas of peripheral bone metastases for pain was derived from both prospective studies and retrospective data, and it can be safe and effective. The use of stereotactic body radiotherapy holds theoretical promise in the treatment of new or recurrent spine lesions, although the Task Force recommended that its use be limited to highly selected patients and preferably within a prospective trial. Surgical decompression and postoperative radiotherapy is recommended for spinal cord compression or spinal instability in highly selected patients with sufficient performance status and life expectancy. The use of bisphosphonates, radionuclides, vertebroplasty, and kyphoplasty for the treatment or prevention of cancer-related symptoms does not obviate the need for external beam radiotherapy in appropriate patients. Conclusions: Radiotherapy is a successful and time efficient method by which to palliate pain and/or prevent the morbidity of bone metastases. This Guideline reviews the available data to define its proper use and provide consensus views concerning contemporary controversies or unanswered questions that warrant prospective trial evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ENDF/B-VII.0 Data Testing Using 1,172 Critical Assemblies

In order to test the ENDF/B-VII.0 neutron data library [1], 1,172 critical assemblies from [2] have been calculated using the Monte Carlo transport code TART [3]. TART's 'best' physics was used for all of these calculations; this included continuous energy cross sections, delayed neutrons in their spectrum that is slower than prompt neutrons, unresolved resonance region self-shielding, the thermal scattering (free atom for all materials plus thermal scattering law data S({alpha},{beta}) when available). In this first pass through the assemblies the objective was to 'quickly' test the validity of the ENDF/B-VII.0 data [1], the assembly models as defined in [2] and coded for use with TART, and TART's physics treatment [3] of these assemblies. With TART we have the option of running criticality problems until K-eff has been calculated to an acceptable input accuracy. In order to 'quickly' calculate all of these assemblies K-eff was calculated in each case to +/- 0.002. For these calculations the assemblies were divided into ten types based on fuel (mixed, Pu239, U233, U235) and median fission energy (Fast, Midi, Slow). A table is provided that shows a summary of these results. This is followed be details for every assembly, and statistical information about the distribution of K-eff for each type of assembly. After a review of these results to eliminate any obvious errors in ENDF/B data, assembly models, or TART physics, all assemblies will be run again to a higher precision. Only after this second run is finished will we have highly precise results. Until then the results presently here should only be interpreted as approximate values of K-eff with a standard deviation of +/- 0.002; for such a large number of assemblies we expected the results to be approximately normal, with a spread out to several times the standard deviation; see the calculated statistical distributions and their comparisons to a normal distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

4D XCAT phantom for multimodality imaging research

Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environment-based pin-power reconstruction method for homogeneous core calculations

Core calculation schemes are usually based on a classical two-step approach associated with assembly and core calculations. During the first step, infinite lattice assemblies calculations relying on a fundamental mode approach are used to generate cross-sections libraries for PWRs core calculations. This fundamental mode hypothesis may be questioned when dealing with loading patterns involving several types of assemblies (UOX, MOX), burnable poisons, control rods and burn-up gradients. This paper proposes a calculation method able to take into account the heterogeneous environment of the assemblies when using homogeneous core calculations and an appropriate pin-power reconstruction. This methodology is applied to MOX assemblies, computed within an environment of UOX assemblies. The new environment-based pin-power reconstruction is then used on various clusters of 3x3 assemblies showing burn-up gradients and UOX/MOX interfaces, and compared to reference calculations performed with APOLLO-2. The results show that UOX/MOX interfaces are much better calculated with the environment-based calculation scheme when compared to the usual pin-power reconstruction method. The power peak is always better located and calculated with the environment-based pin-power reconstruction method on every cluster configuration studied. This study shows that taking into account the environment in transport calculations can significantly improve the pin-power reconstruction so far as it is consistent with the core loading pattern. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗