Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Evaluation of Joint Cyber/Safety Risk in Nuclear Power Systems

This report presents an analysis of the Emergency Core Cooling System (ECCS) for a generic Boiling Water Reactor (BWR)-4 NPP. The Electric Power Research Institute (EPRI) developed Hazards and Consequences Analysis for Digital Systems (HAZCADS) process is applied to the ECCS and its subsystems to identify unsafe control actions (UCAs) which act as possible cyber events of concern. The analysis is performed for two design basis events: Small-break Loss of Coolant Accident (SLOCA) and general transients (TRANS), such as unintended reactor trip. In previous work, HAZCADS UCAs were combined with other cyber-attack analysis to develop a risk-informed approach; however, this was for a single system. This report explores advanced systems engineering modeling approaches to model the interactions between digital assets across multiple systems which may be targeted by cyber adversaries. The complex and interdependent design of digital systems has the potential to introduce emergent cyber properties that are generally not covered by hazard analyses nor formal nuclear Probabilistic Risk Assessment (PRA). The R&D and supporting analysis presented here explores approaches to predict and manage how interdependent system properties effect risk. To show the potential impact of a successful cyber-attack to formal PRA event tree probabilities, HAZCADS analysis was also used. HAZCADS was also used to model the automatic depressurization system (ADS) automatic actuation. This analysis extended to an integrated system analysis for common-cause failure (CCF). In this aspect, the HAZCADS analysis continued by analyzing plant design details for system connectivity in support of critical plant functions. A dependency matrix was developed to depict the integrated functionality of the interconnected systems. Areas of potential CCF are indicated. Future work could include adversary attack development to show how CCF could be caused, resulting in PRA events. Across the multiple systems that comprise the ECCS, the analysis shows that the change in such probabilities was very different between systems. This indicates that some systems have a larger potential risk impact from successful cyber-attack or digital failure, which indicates a need for these systems to have a higher priority for design and defensive measures. Furthermore, we were able to establish that a risk analysis using any arbitrary threat model establishes an ordering of components with regard to cyber-risk. This ordering can be used to influence the overall system design with an eye to lowering risk, or as a way to understand real-time risk to operational systems based on a current threat landscape. Expert knowledge of both the analysis process and the system being analyzed is required to perform a HAZCADS analysis. The need for a tiered risk analysis is demonstrated by the results of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oak Ridge D and D Plan 3515 Project - Technology Review (2007) and GammaCam Technology Demonstration for Characterizing Building 3515 at Oak Ridge (2007)

This paper presents the results from the Characterization, Decontamination and Decommissioning (CD and D) Study performed by MSE Technology Application, Inc. (MSE) to assist the U.S. Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) in the preparation of a Project Execution Plan and Remediation Plan for Building 3515 at ORNL. Primary objectives of this study were to identify innovative CD and D technologies and methodologies and recommend alternatives applicable to the CD and D of Building 3515. Building 3515 is a small heavily shielded concrete and cement block structure centrally located in the Bethel Valley portion of the ORNL. The building's interior is extensively contaminated with Cesium 137 (Cs-137), the primary contaminant of concern. A previous attempt to characterize the building was limited to general interior area radiation exposure level measurements and a few surface smears gathered by inserting monitoring equipment into the building on long poles. Consequently, the spatial distribution of the gamma radiation source inside the building was not determined. A subsequent plan for D and D of the building presented a high risk of worker radiation dose in excess of as low as reasonably achievable (ALARA) because the source of the interior gamma radiation field is not completely understood and conventional practices required workers to be in close proximity of the building. As part of an initial literature search, MSE reviewed new generation gamma source characterization technologies and identified the GammaCam{sup TM} portable gamma ray imaging system as an innovative technology applicable to locating the dominant gamma ray sources within the building. The GammaCam{sup TM} gamma-ray imaging system is a commercially available technology marketed by the EDO Corporation. This system consists of a sensor head with a co-aligned camera and a portable computer. The system is designed to provide two-dimensional spatial mappings of gamma ray emitting nuclides in real time. The gamma radiation sensor and camera can be set up within or outside of the radiation field while the system operator and PC can be located 30 to 60 m (100 to 200 ft) from the sensor head. The system has been used successfully at numerous DOE and commercial nuclear facilities to precisely locate gamma radiation sources. However, literature attesting to the ability of this technology to detect radiation sources within heavily shielded structures was not available. Consequently, MSE was not certain if this technology would be capable of locating gamma ray sources within the heavily shielded Building 3515. To overcome this uncertainty, MSE sent two individuals to the EDO Corporation for training. At completion of the training, MSE leased the GammaCam{sup TM} portable system and brought it to ORNL to evaluate the capability of the system. An overview from this evaluation is summarized in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Delivery of a Solar-Powered Forward Osmosis Seawater Desalination Plant: Trevi’s 500 m3/day Zero-Carbon FO Seawater Desalination Plant at NELHA

This paper presents an account of Trevi’s delivery of a 500 m3/day solar powered forward osmosis (FO) seawater desalination plant at the Ocean Science and Technology Park of the Natural Energy Laboratory of Hawaii Authority (NELHA). The project aimed to demonstrate the viability of solar thermal-powered desalination for agricultural applications through the integration of a 2MW micro-dish solar thermal array with a state-of-the-art FO system. Highlighted in the paper are the three distinct project phases; Planning and Design, System Construction, Installation & Testing followed finally by System Operation and Optimization. Results and decisions which led to the final plant design will be shared, highlighting how Trevi Systems succeeded in producing a zero-carbon FO seawater desalination plant with a projected Levelized Cost of Water (LCOW) estimate competitive with existing carbon-intensive RO technologies (based on some assumptions and the cost of heat which is required for FO.

14 SOLAR ENERGY↗

The Effects of Degraded Digital Instrumentation and Control Systems on Human-system Interfaces and Operator Performance: HFE Review Guidance and Technical Basis

New and advanced reactors will use integrated digital instrumentation and control (I&C) systems to support operators in their monitoring and control functions. Even though digital systems are typically highly reliable, their potential for degradation or failure could significantly affect operator performance and, consequently, impact plant safety. The U.S. Nuclear Regulatory Commission (NRC) supported this research project to investigate the effects of degraded I&C systems on human performance and plant operations. The objective was to develop human factors engineering (HFE) review guidance addressing the detection and management of degraded digital I&C conditions by plant operators. We reviewed pertinent standards and guidelines, empirical studies, and plant operating experience. In addition, we conducted an evaluation of the potential effects of selected failure modes of the digital feedwater system on human-system interfaces (HSIs) and operator performance. The results indicated that I&C degradations are prevalent in plants employing digital systems and the overall effects on plant behavior can be significant, such as causing a reactor trip or causing equipment to operate unexpectedly. I&C degradations can impact the HSIs used by operators to monitor and control the plant. For example, sensor degradations can make displays difficult to interpret and can sometimes mislead operators by making it appear that a process disturbance has occurred. We used the information obtained as the technical basis upon which to develop HFE review guidance. The guidance addresses the treatment of degraded I&C conditions as part of the design process and the HSI features and functions that support operators to monitor I&C performance and manage I&C degradations when they occur. In addition, we identified topics for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources and transacts with a regulated distribution system operator (DSO) under a generalized net energy metering tariff design. To ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, we propose an incentive-aligned community pricing mechanism under which the decentralized optimization of community members' benefit implies the optimization of overall community welfare. The proposed pricing mechanism satisfies the cost-causation principle and ensures the stability of the energy community in a coalition game setting. Numerical examples provide insights into the characteristics of the proposed pricing mechanism and quantitative measures of its performance.

distributed energy resources aggregation↗

SCUC-DER Integration Report: Integrating Distributed Energy Resources (DER) Using Advanced Unit Commitment Models and DER Aggregation Methodologies

Distributed energy resources (DERs) are continuing to grow due to regulatory, policy, and market shifts, and it needs to be ensured that small DERs are given a level playing field with traditional resources. Legacy market processes such as unit-commitment problems were designed for a power grid consisting largely of centralized power plants. In contrast, DERs consist of many small devices with distinct operating characteristics that may or may not be connected at the transmission interconnection points, limiting their visibility to the independent system operators (ISOs) who operate wholesale electricity markets. This report details the development and initial results from a simulation platform that integrates state-of-the-art security-constrained unit commitment software, detailed feeder models, and a DER aggregator model to quantify potential DER integration issues. Quantitative results to date illustrate potential infeasible scheduling solutions from SCUC when the DERA includes aggregations of energy-limited energy storage resources. Likewise, if aggregations are not penalized for dispatch deviations, they may have incentives to deviate from the SCUC-determined resource schedules. Assumptions about the amount of aggregated demand response resources (DRRs) and the ability of DERAs to follow profit incentives have an important impact – DRRs have significant flexibility and can typically feasibly meet their SCUC schedule, but on the other hand, their profit incentives can cause unscheduled increases in load before and after DRR dispatch. Computation time results on the SCUC solver and simulation platform only show a modest increase in SCUC solution time as the number of DERAs is increased, but results to date only reflect the RTS-GMLC test system; results may show more significant solver slowdown in larger transmission systems. The largest contribution to simulation time is attributed to the DERA offer generation method, which is suggested for future improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DEVELOPMENT OF A 4 K STIRLING-TYPE PULSE TUBE CRYOCOOLER FOR A MOBILE TERAHERTZ DETECTION SYSTEM

We discuss in this paper the design and development of a 4 K Stirling-type pulse tube cryocooler for a mobile terahertz detection system. This system integrates new heterodyne detector technology at terahertz frequencies with advancements of Stirling-type pulse tube technology that brings the advent of cooled detector sensitivities in a mobile, compact, and long duration operation system without degradation of sensitivity. To achieve this goal we reduced overall system size, input power, and temperature fluctuations and mechanical vibrations in order to maintain the detector sensitivity. The Stirling-type pulse tube cryocooler developed for this system is a hybrid design employing a He-4 pulse-tube cryocooler operating at 60 Hz and 2.5 MPa average pressure that precools a He-3 pulse tube cryocooler operating at 30 Hz and 1.0 MPa average pressure to achieve 4 K cooling for the terahertz receiver. The He-4 cryocooler employs stainless steel mesh regenerators for the first stage and ErPr spheres for the second stage, while the He-3 cryocooler employs stainless mesh for the first stage and ErPr spheres for the second stage with a layered rare-earth third stage regenerator. Design details and cooler performance goals are discussed.

42 ENGINEERING↗

Summary of operations and performance of the Utica aquifer and North Lake Basin Wetlands restoration project in December 2010-November 2011

This document summarizes the performance of the groundwater restoration systems installed by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) at the former CCC/USDA grain storage facility in Utica, Nebraska, during the seventh year of system operation, from December 1, 2010, until November 30, 2011.

LaFreniere, L. M.↗

Continuously-operable flow stream processing system and method

A continuously-operable flow stream processing system and method has two or more fluid processing media arranged in a fluid conduit network to provide alternate flow paths for a flow stream to be processed (e.g. filtered). Valves and other flow control devices, e.g. controller module and sensors, are used to redirect the flow stream from one or more service-needed fluid processing media to service-ready fluid processing media without taking the system offline to remove, repair, replace, clean in situ, or otherwise service the service-needed fluid processing media, so that the system may operate continuously to process the flow stream without stoppage. Redirection into alternative flow paths and media may be automatically implemented based on a predetermined threshold or trigger condition, such as may be detected by sensors directly or indirectly monitoring media condition.

42 ENGINEERING↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Fluid-Bed Testing of GreatPoint Energy's Direct Oxygen Injection Catalytic Gasification Process for Synthetic Natural Gas and Hydrogen Coproduction: Year 6 - Activity 1.14 - Development of a National Center for Hydrogen Technology

The GreatPoint Energy (GPE) concept for producing synthetic natural gas and hydrogen from coal involves the catalytic gasification of coal and carbon. GPE’s technology “refines” coal by employing a novel catalyst to “crack” the carbon bonds and transform the coal into cleanburning methane (natural gas) and hydrogen. The GPE mild “catalytic” gasifier design and operating conditions result in reactor components that are less expensive and produce pipeline-grade methane and relatively high purity hydrogen. The system operates extremely efficiently on very low cost carbon sources such as lignites, subbituminous coals, tar sands, petcoke, and petroleum residual oil. In addition, GPE’s catalytic coal gasification process eliminates troublesome ash removal and slagging problems, reduces maintenance requirements, and increases thermal efficiency, significantly reducing the size of the air separation plant (a system that alone accounts for 20% of the capital cost of most gasification systems) in the catalytic gasification process.

01 COAL, LIGNITE, AND PEAT↗

Stochastic pump effect and geometric phases in dissipative and stochastic systems

The success of Berry phases in quantum mechanics stimulated the study of similar phenomena in other areas of physics, including the theory of living cell locomotion and motion of patterns in nonlinear media. More recently, geometric phases have been applied to systems operating in a strongly stochastic environment, such as molecular motors. We discuss such geometric effects in purely classical dissipative stochastic systems and their role in the theory of the stochastic pump effect (SPE).

97 MATHEMATICS AND COMPUTING↗

Solutal-buoyancy-driven intertwining and rotation of patterned elastic sheets

Abstract The intertwining of strands into 3D spirals is ubiquitous in biology, enabling functions from information storage to maintenance of cell structure and directed locomotion. In synthetic systems, entwined fibers can provide superior mechanical properties and act as artificial muscle or structural reinforcements. Unlike structures in nature, the entwinement of synthetic materials typically requires application of an external stimulus, such as mechanical actuation, light, or a magnetic field. Herein, we use computational modeling to design microscale sheets that mimic biology by transducing chemical energy into mechanical action, and thereby self-organize and interlink into 3D spirals, which spontaneously rotate. These flexible sheets are immersed in a fluid-filled microchamber that encompasses an immobilized patch of catalysts on the bottom wall. The sheets themselves can be passive or active (coated with catalyst). Catalytic reactions in the solution generate products that occupy different volumes than the reactants. The resulting density variations exert a force on the fluid (solutal buoyancy force) that causes motion, which in turn drives the interlinking and collective swirling of the sheets. The individual sheets do not rotate; rotation only occurs when the sheets are interlinked. This level of autonomous, coordinated 3D structural organization, intertwining, and rotation is unexpected in synthetic materials systems operating without external controls. Using physical arguments, we identify dimensionless ratios that are useful in scaling these ideas to other systems. These findings are valuable for creating materials that act as “machines”, and directing soft matter to undergo self-sustained, multistep assembly that is governed by intrinsic chemical reactions.

Manna, Raj Kumar (ORCID:0000000322729487)↗

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Characterizing cyber tools for monitoring power grid systems: what information is available and who needs it?

Abstract—The power grid is a complex, interconnected system that requires the coordination of multiple entities ensure the reliability of the system. System operators must be aware of the impacts of various natural and man-made contingencies through telemetry from their control systems, and they must also be aware of the integrity and availability of the cyber assets on their systems. A team of researchers from PNNL and INL have conducted a series of observations and interviews at power utilities to identify what information needs to be available for both control room dispatchers and cyber security analysts to maintain situation awareness of cyber security to effectively monitor the cyber assets on utility control systems. The researchers interviewed and observed control room dispatchers and spoke with regional control system engineers and cyber security analysts to define the context in which such information would be used. The results of this work will inform the design of a tool that will enhance cyber situation awareness and help facilitate effective communication between the various roles and organizations with utility and other regional authorities during contingencies. Index Terms—

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and implementation of I/O performance prediction scheme on HPC systems through large-scale log analysis

Abstract Large-scale high performance computing (HPC) systems typically consist of many thousands of CPUs and storage units used by hundreds to thousands of users simultaneously. Applications from large numbers of users have diverse characteristics, such as varying computation, communication, memory, and I/O intensity. A good understanding of the performance characteristics of each user application is important for job scheduling and resource provisioning. Among these performance characteristics, I/O performance is becoming increasingly important as data sizes rapidly increase and large-scale applications, such as simulation and model training, are widely adopted. However, predicting I/O performance is difficult because I/O systems are shared among all users and involve many layers of software and hardware stack, including the application, network interconnect, operating system, file system, and storage devices. Furthermore, updates to these layers and changes in system management policy can significantly alter the I/O behavior of applications and the entire system. To improve the prediction of the I/O performance on HPC systems, we propose integrating information from several different system logs and developing a regression-based approach to predict the I/O performance. Our proposed scheme can dynamically select the most relevant features from the log entries using various feature selection algorithms and scoring functions, and can automatically select the regression algorithm with the best accuracy for the prediction task. The evaluation results show that our proposed scheme can predict the write performance with up to 90% prediction accuracy and the read performance with up to 99% prediction accuracy using the real logs from the Cori supercomputer system at NERSC.

97 MATHEMATICS AND COMPUTING↗