Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES - ELASTICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Control design and robustness analysis of a ball and plate system by using polynomial chaos

In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field radiative heat transfer between two parallel SiO{sub 2} plates with and without microcavities

Near-to-far-field radiative heat transfer between two macroscopic SiO{sub 2} plates—with and without microcavities—was observed using a highly precise and accurate optical gap-measurement method. The experiments, conducted near 300 K, measured heat transfer as a function of gap separation from 1.0 μm to 50 μm and also as a function of temperature differences between 4.1 and 19.5 K. The gap-dependent heat flux was in excellent agreement with theoretical predictions. Furthermore, the effects of microcavities on the plate surfaces were clearly observed and significant enhancement of near-field radiative heat transfer was confirmed between gold-coated microcavities with narrow vacuum separation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High magnetic-refrigeration performance of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides sintered in high-pressure H{sub 2} atmosphere

La(Fe, Si){sub 13} hydride is regarded as one of the most promising room-temperature refrigerants. However, to use the alloys in an active magnetic regenerator machine, it is vital to prepare thin refrigerants. In this work, a high H{sub 2} gas pressure of 50 MPa was employed to suppress the desorption of hydrogen atoms during the sintering process of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides. At 330 K, a high-density sintered thin plate shows a large magnetic-entropy change ΔS{sub m} of 15.5 J/kg K (106 mJ/cm{sup 3 }K) for a field change of 2 T. The volumetric ΔS{sub m} is almost twice as large as that of bonded La(Fe,Si){sub 13} hydrides. Favorably, hysteresis is almost absent due to the existence of micropores with a porosity of 0.69% which has been analyzed with high-resolution X-ray microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mo layer thickness requirement on the ion source back plate for the HNB and DNB ion sources in ITER

All the inner surfaces of the ion sources and the upstream surface of the plasma grid of the ITER neutral beam ion sources are proposed to be coated with molybdenum. This is done to avoid sputtering of the base material (Cu or CuCrZr) by the ions in the source plasma (D{sup +}, D{sub 2}{sup +}, D{sub 3}{sup +} or H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}). The sputtering of Mo by the ions in the source plasma is low compared to that from Cu, and the threshold energy for sputtering ∼80 eV) is high compared to the energy of the ions in the source. However the D{sub 2}{sup +}, H{sub 2}{sup +} and D{sup +}, H{sup +} ions backstreaming from the accelerators will have energies that substantially exceed that threshold and it is important that the Mo layer is not eroded such that the base material is exposed to the source plasma. In the case of the HNB, the backstreaming ion power is calculated to be in the order of ∼1 MW, and the average energy of the backstreaming ions is calculated to be ∼300 keV. The ion sources in the HNB beam lines, 40 A 1 MeV D and 46 A 870 keV H beams, are supposed to operate for a period of 2 x 10{sup 7} s. For the DNB, 60 A 100 keV H beams, the corresponding number is 1.4 × 10{sup 6} s considering a beam duty cycle of 3s ON/20s OFF with 5 Hz modulation. The Mo layer on the ion source back plate should be thick enough to survive this operational time. Thickness estimation has been carried out taking into account the sputtering yields (atoms/ion), the energy spectrum of the backstreaming ions and the estimated profiles on the ion source back plate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

07 ISOTOPE AND RADIATION SOURCES↗

Magnetized sheath near positively biased wall between two permanent magnetic plates

The characteristics of magnetized electron sheath near a positively biased conducting wall parallel to magnetic field formed between two permanent magnetic plates were experimentally investigated in a double plasma device. The magnetic field strength between the magnetic plates is about 1200 G which is sufficient to magnetize the plasma such that the ion gyroradius is comparable to the electron Debye length. A virtual cathode (or potential dip) structure was found between the electron-rich sheath and bulk plasma. For a given neutral gas pressure, the potential minimum (dip position) remains almost the same for different positive biases on the wall. For a given bias on the wall, however, the electron sheath thickness and the potential drop from the bulk plasma to the dip decrease with the increase of the neutral gas pressure. In addition, the electron sheath and potential dip appear to be wider and deeper in the downstream side of the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical and acoustic sensing using Fano-like resonances in dual phononic and photonic crystal plate

We perform a theoretical study based on the transmissions of optical and acoustic waves normally impinging to a periodic perforated silicon plate when the embedded medium is a liquid and show the existence of Fano-like resonances in both cases. The signature of the resonances appears as well-defined asymmetric peaks in the phononic and photonic transmission spectra. We show that the origin of the Fano-like resonances is different with respect to the nature of the wave. In photonic, the origin comes from guided modes in the photonic plate while in phononic we show that it comes from the excitation of standing waves confined inside the cavity coming from the deformation of the water/silicon edges of the cylindrical inclusion. We finally use these features for sensing and show ultra-sensitivity to the light and sound velocities for different concentrations of analytes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heat transfer in porous medium embedded with vertical plate: Non-equilibrium approach - Part A

Heat transfer in a porous medium embedded with vertical flat plate is investigated by using thermal non-equilibrium model. Darcy model is employed to simulate the flow inside porous medium. It is assumed that the heat transfer takes place by natural convection and radiation. The vertical plate is maintained at isothermal temperature. The governing partial differential equations are converted into non-dimensional form and solved numerically using finite element method. Results are presented in terms of isotherms and streamlines for various parameters such as heat transfer coefficient parameter, thermal conductivity ratio, and radiation parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Measurement of optical absorption in polycrystalline CVD diamond plates by the phase photothermal method at a wavelength of 10.6 {mu}m

A highly-efficient phase photothermal method is developed for quantitative measurements of the small optical absorption coefficient in thin plates made of highly transparent materials in which bulk losses significantly exceed surface losses. The bulk absorption coefficient at 10.6 {mu}m is estimated in polycrystalline diamond plates grown from the vapour phase (a CVD diamond). The results are compared with those for natural and synthetic diamond single crystals and with the concentrations of nitrogen and hydrogen impurities. The absorption coefficient of the best samples of the CVD diamond did not exceed 0.06 cm{sup -1}, which, taking into account the high thermal conductivity of the CVD diamond (1800-2200 W mK{sup -1} at room temperature), makes this material attractive for fabricating output windows of high-power CO{sub 2} lasers, especially for manufacturing large-size optics. (laser applications and other topics in quantum electronics)

36 MATERIALS SCIENCE↗

High-repetition-rate plate-electrode CO{sub 2} laser

A high-repetition-rate CO{sub 2} laser with the inductive-capacitive discharge stabilisation is studied for the first time. A multisection discharge gap of length 250 mm was formed by pairs of anode - cathode plates arranged in the form of a broken line. The width of the discharge region between each pair of the plates was {approx} 1.3 mm and height {approx} 12 mm. The cross section of the laser beam on the output mirror of the resonator was {approx} 6 x 8 mm. The maximum output energy of the laser using the CO{sub 2}:N{sub 2}:He=32:32:96 Torr mixture was 15.9 mJ, the lasing efficiency being 1.7%. For a relatively low gas flow rate of 19 m s{sup -1}, a CO{sub 2} laser pulse repetition rate of 3 kHz was achieved, the relative root-mean-square deviation of the pulse energy being within 5%. The average output power of the laser was {approx} 40 W. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Drilling and cutting of thin metal plates in water with radiation of a repetitively pulsed Nd : YAG laser

The conditions of drilling and cutting of 0.15-mm-thick titanium and stainless steel plates in water with the radiation of a repetitively pulsed Nd : YAG laser having the mean power up to 30 W are studied experimentally in the absence of water and gas jets. Dependences of the maximal cutting speed in water on the radiation power are obtained, the cutting efficiency is determined, and the comparison with the conditions of drilling and cutting of plates in air is carried out.

42 ENGINEERING↗

Astrometry of Pluto from 1930-1951 observations: The Lampland plate collection

We present a new analysis of 843 photographic plates of Pluto taken by Carl Lampland at Lowell Observatory from 1930–1951. This large collection of plates contains useful astrometric information that improves our knowledge of Pluto's orbit. This improvement provides critical support to the impending flyby of Pluto by New Horizons. New Horizons can do inbound navigation of the system to improve its targeting. This navigation is capable of nearly eliminating the sky-plane errors but can do little to constrain the time of closest approach. Thus the focus on this work was to better determine Pluto's heliocentric distance and to determine the uncertainty on that distance with a particular eye to eliminating systematic errors that might have been previously unrecognized. This work adds 596 new astrometric measurements based on the USNO CCD Astrograph Catalog 4. With the addition of these data the uncertainty of the estimated heliocentric position of Pluto in Developmental Ephemerides 432 (DE432) is at the level of 1000 km. This new analysis gives us more confidence that these estimations are accurate and are sufficient to support a successful flyby of Pluto by New Horizons.

79 ASTRONOMY AND ASTROPHYSICS↗

MANTLE CONVECTION, PLATE TECTONICS, AND VOLCANISM ON HOT EXO-EARTHS

Recently discovered exoplanets on close-in orbits should have surface temperatures of hundreds to thousands of Kelvin. They are likely tidally locked and synchronously rotating around their parent stars and, if an atmosphere is absent, have surface temperature contrasts of many hundreds to thousands of Kelvin between permanent day and night sides. We investigated the effect of elevated surface temperature and strong surface temperature contrasts for Earth-mass planets on the (1) pattern of mantle convection, (2) tectonic regime, and (3) rate and distribution of partial melting, using numerical simulations of mantle convection with a composite viscous/pseudo-plastic rheology. Our simulations indicate that if a close-in rocky exoplanet lacks an atmosphere to redistribute heat, a {approx}>400 K surface temperature contrast can maintain an asymmetric degree 1 pattern of mantle convection in which the surface of the planet moves preferentially toward subduction zones on the cold night side. The planetary surface features a hemispheric dichotomy, with plate-like tectonics on the night side and a continuously evolving mobile lid on the day side with diffuse surface deformation and vigorous volcanism. If volcanic outgassing establishes an atmosphere and redistributes heat, plate tectonics is globally replaced by diffuse surface deformation and volcanism accelerates and becomes distributed more uniformly across the planetary surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron nuclear double resonance study of photostimulated luminescence active centers in CsBr:Eu{sup 2+} medical imaging plates

CsBr:Eu{sup 2+} needle image plates exhibit an electron-paramagnetic-resonance (EPR) spectrum at room temperature (RT), whose intensity is correlated with the photostimulated luminescence sensitivity of the plate. This EPR spectrum shows a strong temperature dependence: At RT it is owing to a single Eu{sup 2+} (S =7/2) center with axial symmetry, whereas at T<35 K the spectra can only be explained when two distinct centers are assumed to be present, a minority axial center and a majority center with nearly extremely rhombic symmetry. In this paper these low-temperature centers are studied with electron nuclear double resonance (ENDOR) spectroscopy, which reveals the presence of {sup 1}H nuclei close to the central Eu{sup 2+} ions in the centers. Analysis of the angular dependence of the ENDOR spectra allows to propose models for these centers, providing an explanation for the observed difference in intensity between the spectral components and for their temperature dependence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Casimir interaction between holes in a plate

We study the leading long-distance attractive force between two holes in a plate arising from a scalar field with Dirichlet boundary conditions on the plate. We use a formalism in which the interaction is governed by a nonlocal field theory which lives on the two holes. The interaction energy is proportional to Q{sub 1}Q{sub 2}/r{sup 7} at large separation r, where Q{sub 1} and Q{sub 2} are certain charges associated with the holes. We compute these charges for round and rectangular holes. We show that the 1/r{sup 7} behavior is universal for separations large compared to the linear dimensions of the holes, irrespective of the spin or interactions of the bosonic field. We also study the interaction between two long thin slits, for which the energy falls off as 1/r{sup 6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Curved Image-Plate Detector System for High-Resolution Synchrotron X-ray Diffraction

The developed curved image plate (CIP) is a one-dimensional detector which simultaneously records high-resolution X-ray diffraction (XRD) patterns over a 38.7 2{theta} range. In addition, an on-site reader enables rapid extraction, transfer and storage of X-ray intensity information in {le}30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X-ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X-ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high-temperature XRD.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams

Purpose: The electron fluence inside a parallel-plate ionization chamber positioned in a water phantom and exposed to a clinical electron beam deviates from the unperturbed fluence in water in absence of the chamber. One reason for the fluence perturbation is the well-known “inscattering effect,” whose physical cause is the lack of electron scattering in the gas-filled cavity. Correction factors determined to correct for this effect have long been recommended. However, more recent Monte Carlo calculations have led to some doubt about the range of validity of these corrections. Therefore, the aim of the present study is to reanalyze the development of the fluence perturbation with depth and to review the function of the guard rings. Methods: Spatially resolved Monte Carlo simulations of the dose profiles within gas-filled cavities with various radii in clinical electron beams have been performed in order to determine the radial variation of the fluence perturbation in a coin-shaped cavity, to study the influences of the radius of the collecting electrode and of the width of the guard ring upon the indicated value of the ionization chamber formed by the cavity, and to investigate the development of the perturbation as a function of the depth in an electron-irradiated phantom. The simulations were performed for a primary electron energy of 6 MeV. Results: The Monte Carlo simulations clearly demonstrated a surprisingly large in- and outward electron transport across the lateral cavity boundary. This results in a strong influence of the depth-dependent development of the electron field in the surrounding medium upon the chamber reading. In the buildup region of the depth-dose curve, the in–out balance of the electron fluence is positive and shows the well-known dose oscillation near the cavity/water boundary. At the depth of the dose maximum the in–out balance is equilibrated, and in the falling part of the depth-dose curve it is negative, as shown here the first time. The influences of both the collecting electrode radius and the width of the guard ring are reflecting the deep radial penetration of the electron transport processes into the gas-filled cavities and the need for appropriate corrections of the chamber reading. New values for these corrections have been established in two forms, one converting the indicated value into the absorbed dose to water in the front plane of the chamber, the other converting it into the absorbed dose to water at the depth of the effective point of measurement of the chamber. In the Appendix, the in–out imbalance of electron transport across the lateral cavity boundary is demonstrated in the approximation of classical small-angle multiple scattering theory. Conclusions: The in–out electron transport imbalance at the lateral boundaries of parallel-plate chambers in electron beams has been studied with Monte Carlo simulation over a range of depth in water, and new correction factors, covering all depths and implementing the effective point of measurement concept, have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗