Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Atomic electron tomography in three and four dimensions

Atomic electron tomography (AET) has become a powerful tool for atomic-scale structural characterization in three and four dimensions. It provides the ability to correlate structures and properties of materials at the single-atom level. With recent advances in data acquisition methods, iterative three-dimensional (3D) reconstruction algorithms, and post-processing methods, AET can now determine 3D atomic coordinates and chemical species with sub-Angstrom precision, and reveal their atomic-scale time evolution during dynamical processes. In this work, we review the recent experimental and algorithmic developments of AET and highlight several groundbreaking experiments, which include pinpointing the 3D atom positions and chemical order/disorder in technologically relevant materials and capturing how atoms rearrange during early nucleation at four-dimensional atomic resolution.

30 DIRECT ENERGY CONVERSION↗

CZT nanoRAIDER_VFG Factsheet

Brookhaven National Laboratory (BNL) is working with FLIR System Inc., the manufacturer of the nanoRAIDER, to design a handheld device based on a position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detector array (with 1% or better energy resolution). The new device called nanoRAIDER VFG will be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER will significantly improve the accuracy while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER VFG for safeguards is anticipated. The nanoRAIDER VFG will help address several items listed in the IAEA’s Long-Term R&D Plan that could enhance the abilities to detect undeclared nuclear material and activities.

36 MATERIALS SCIENCE↗

Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3 He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3 He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron ( 10 B) and enriched lithium ( 6 Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (t g ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10 -24 cm 2 ), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

High gain, Fast Scan, Broad Spectrum Parallel Beam Wavelength Dispersive X-ray Spectrometer for SEM

During contract # DE-FG02-ER83545, Parallax Research, Inc. developed a High gain, Fast Scan Broad Spectrum Parallel beam Wavelength Dispersive X-ray Spectrometer for use on Scanning Electron Microscopes (SEM). This new spectrometer allows very fast high resolution elemental analysis of samples in an electron microscope. By comparison to previous WDS spectrometers, it can change from one energy position to another very quickly and has an extended range compared to some similar products.

47 OTHER INSTRUMENTATION↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of an Agitated Tube Reactor for use in the Reprocessing of Spent Nuclear Fuel

Aims: Convert an Agitated Tube Reactor (ATR) into a counter-current solvent extraction device. Assess effect of liquid fill level on liquid dispersion. The agitated tube reactor (ATR) is an array of connected tubes. The ATR laterally shakes in a sinusoidal path, moving the agitator bar to create mixing. Originally designed by AM Technology as a cocurrent reactor, the ATR has many features that are potentially useful in the nuclear industry: Tubes are connected by non-moving seals; Reduction in seal damage and reduced risk of expensive repairs in radioactive environments; Minimal axial dispersion within a tube; Plug flow; Narrower residence time distributions that traditional technology; Multiple tubes allow for multiple reactions in series; Converting to a counter-current design allows the ATR to be used for solvent extraction; Reprocessing or decommissioning. A 180 ml PERSPEX ATR tube with no liquid flow through was constructed and filled with a 1:1 solvent:aqueous ratio of kerosene and water. The tube was filled such that the total liquid filled 25 %, 50 %, 75 % or 100 % of the tube. A Photron Fastcam SA5, positioned at the side and the end of the tube was set to a frame rate of 5400 fps with a resolution of 1024 x 1024 and 6000 fps with a resolution of 1024 x 896 respectively. Droplets were recorded after 2 minutes of shaking to ensure good mixing. Droplet sizes are used to determine optimum fill level in the ATR. The shaking frequency follows a sinusoidal path and was set to 5 Hz. The images shown in the results section were taken at the peak of the sinusoidal motion. To convert to a counter-current design the two liquids need to be separated at the end of each tube. Liquids have been allowed to separate under gravity separation. Inclusion of baffles to reduce remixing by sloshing. Wall with height corresponding to 25 % fill volume allows kerosene to overflow into separate outlet. Increase in liquid fill level decreases the dispersion of the two liquid phases. Higher dispersion of droplets decreases surface area and therefore increases mass transfer in solvent extraction. 25 % should provide the greatest mass transfer though more work needs to completed to confirm this.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-549: Validation of a Method for in Vivo 3D Dose Reconstruction for SBRT Using a New Transmission Detector

Purpose: Recently, there has been increased clinical use of stereotactic body radiation therapy (SBRT). SBRT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. In vivo dose measurements, a commercially available quality assurance platform which is able to correlate the delivered dose to the patient’s anatomy and take into account tissue inhomogeneity, is the COMPASS system (IBA Dosimetry, Germany) using a new transmission detector (Dolphin, IBA Dosimetry). In this work, we evaluate a method for in vivo 3D dose reconstruction for SBRT using a new transmission detector, which was developed for in vivo dose verification for intensity-modulated radiation therapy (IMRT). Methods: We evaluated the accuracy of measurement for SBRT using simple small fields (2×2−10×10 cm2), a multileaf collimator (MLC) test pattern, and clinical cases. The dose distributions from the COMPASS were compared with those of EDR2 films (Kodak, USA) and the Monte Carlo simulations (MC). For clinical cases, we compared MC using dose-volume-histograms (DVHs) and dose profiles. Results: The dose profiles from the COMPASS for small fields and the complicated MLC test pattern agreed with those of EDR2 films, and MC within 3%. This showed the COMPASS with Dolphin system showed good spatial resolution and can measure small fields which are required for SBRT. Those results also suggest that COMPASS with Dolphin is able to detect MLC leaf position errors for SBRT. In clinical cases, the COMPASS with Dolphin agreed well with MC. The Dolphin detector, which consists of ionization chambers, provided stable measurement. Conclusion: COMPASS with Dolphin detector showed a useful in vivo 3D dose reconstruction for SBRT. The accuracy of the results indicates that this approach is suitable for clinical implementation.

60 APPLIED LIFE SCIENCES↗

THE KEPLER FOLLOW-UP OBSERVATION PROGRAM. I. A CATALOG OF COMPANIONS TO KEPLER STARS FROM HIGH-RESOLUTION IMAGING

We present results from high-resolution, optical to near-IR imaging of host stars of Kepler Objects of Interest (KOIs), identified in the original Kepler field. Part of the data were obtained under the Kepler imaging follow-up observation program over six years (2009–2015). Almost 90% of stars that are hosts to planet candidates or confirmed planets were observed. We combine measurements of companions to KOI host stars from different bands to create a comprehensive catalog of projected separations, position angles, and magnitude differences for all detected companion stars (some of which may not be bound). Our compilation includes 2297 companions around 1903 primary stars. From high-resolution imaging, we find that ∼10% (∼30%) of the observed stars have at least one companion detected within 1″ (4″). The true fraction of systems with close (≲4″) companions is larger than the observed one due to the limited sensitivities of the imaging data. We derive correction factors for planet radii caused by the dilution of the transit depth: assuming that planets orbit the primary stars or the brightest companion stars, the average correction factors are 1.06 and 3.09, respectively. The true effect of transit dilution lies in between these two cases and varies with each system. Applying these factors to planet radii decreases the number of KOI planets with radii smaller than 2 R{sub ⊕} by ∼2%–23% and thus affects planet occurrence rates. This effect will also be important for the yield of small planets from future transit missions such as TESS.

79 ASTRONOMY AND ASTROPHYSICS↗

The role of general nuclear medicine in breast cancer

The rising incidence of breast cancer worldwide has prompted many improvements to current care. Routine nuclear medicine is a major contributor to a full gamut of clinical studies such as early lesion detection and stratification; guiding, monitoring, and predicting response to therapy; and monitoring progression, recurrence or metastases. Developments in instrumentation such as the high-resolution dedicated breast device coupled with the diagnostic versatility of conventional cameras have reinserted nuclear medicine as a valuable tool in the broader clinical setting. This review outlines the role of general nuclear medicine, concluding that targeted radiopharmaceuticals and versatile instrumentation position nuclear medicine as a powerful modality for patients with breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Position-sensitive change in the transition metal L-edge fine structures

Studying the structure and composition of solid-state materials on the atomic scale has become nearly routine in transmission electron microscopy with the development of novel electron optics and electron sources. In particular, with spatial resolutions better than 0.1 nm and energy resolution smaller than 100 meV, the stoichiometry, bonding, and coordination can now be examined on similar scales. Aberration-corrected scanning transmission electron microscopy and electron energy-loss spectroscopy (EELS) have played a crucial role in identifying charge ordering, valence, and as spin state transitions in transition metal perovskite oxides. In this letter, we investigate the effects of ever-decreasing electron-probe sizes on the measured near-edge fine-structure of the transition metal core-loss edge using EELS. We find that for certain transition metal perovskites, the position of the electron probe with respect to the atomic column is crucial in determining the correct valence state. Several reasons for the observed position-sensitive EELS fine-structure are discussed.

36 MATERIALS SCIENCE↗

Structure and Function of the RedJ Protein, a Thioesterase from the Prodiginine Biosynthetic Pathway in Streptomyces coelicolor

Prodiginines are a class of red-pigmented natural products with immunosuppressant, anticancer, and antimalarial activities. Recent studies on prodiginine biosynthesis in Streptomyces coelicolor have elucidated the function of many enzymes within the pathway. However, the function of RedJ, which was predicted to be an editing thioesterase based on sequence similarity, is unknown. We report here the genetic, biochemical, and structural characterization of the redJ gene product. Deletion of redJ in S. coelicolor leads to a 75% decrease in prodiginine production, demonstrating its importance for prodiginine biosynthesis. RedJ exhibits thioesterase activity with selectivity for substrates having long acyl chains and lacking a {beta}-carboxyl substituent. The thioesterase has 1000-fold greater catalytic efficiency with substrates linked to an acyl carrier protein (ACP) than with the corresponding CoA thioester substrates. Also, RedJ strongly discriminates against the streptomycete ACP of fatty acid biosynthesis in preference to RedQ, an ACP of the prodiginine pathway. The 2.12 {angstrom} resolution crystal structure of RedJ provides insights into the molecular basis for the observed substrate selectivity. A hydrophobic pocket in the active site chamber is positioned to bind long acyl chains, as suggested by a long-chain ligand from the crystallization solution bound in this pocket. The accessibility of the active site is controlled by the position of a highly flexible entrance flap. These data combined with previous studies of prodiginine biosynthesis in S. coelicolor support a novel role for RedJ in facilitating transfer of a dodecanoyl chain from one acyl carrier protein to another en route to the key biosynthetic intermediate 2-undecylpyrrole.

59 BASIC BIOLOGICAL SCIENCES↗

Leader effects on femtosecond-laser-filament-triggered discharges

Dynamics of laser filaments in strong nonuniform electric fields is studied with high temporal and spatial resolution. Considerable reduction of the breakdown potential is found and is attributed to a filament-induced leader. Two breakdown modes, fast and slow, are found in 0.4 MV positive dc-voltage discharges activated by filaments that are induced by 65 fs, 170 mJ laser pulses. In the fast mode with duration order of a few microseconds, the filament may acquire the electrode potential and temporarily maintain it, becoming a leader. This gives rise to an average electric field over the attachment instability threshold between a leader head and cathode. Ionization waves precede the breakdown with maximal voltage reduction up to 40% for this mode. The slow mode with its duration order of 1 ms appears with a considerably smaller voltage reduction when the leader decays before the secondary streamer; the breakdown delay depends on negative and positive ion mobilities in this case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broad Separation of Isomeric Lipids by High-Resolution Differential Ion Mobility Spectrometry with Tandem Mass Spectrometry

Maturation of metabolomics has brought a deeper appreciation for the importance of isomeric identity of lipids to their biological role, mirroring that for proteoforms in proteomics. However, full characterization of the lipid isomerism has been thwarted by paucity of rapid and effective analytical tools. A novel approach is ion mobility spectrometry (IMS) and particularly differential or field asymmetric waveform IMS (FAIMS) at high electric fields, which is more orthogonal to mass spectrometry. Here we broadly explore the power of FAIMS to separate lipid isomers, and find a ~75% success rate across the four major types of glycero- and phospho- lipids (sn, chain length, double bond position, and cis/trans). The resolved isomers were identified using standards, and (for the first two types) tandem mass spectrometry. These results demonstrate the general merit of incorporating high-resolution FAIMS into lipidomic analyses. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and mechanistic analysis of trans-3-chloroacrylic acid dehalogenase activity

Trans-3-chloroacrylic acid dehalogenase (CaaD) is a critical enzyme in the trans-1,3-dichloropropene (DCP) degradation pathway in Pseudomonas pavonaceae 170. This enzyme allows bacteria to use trans-DCP, a common component in commercially produced fumigants, as a carbon source. CaaD specifically catalyzes the fourth step of the pathway by cofactor-independent dehalogenation of a vinyl carbon-halogen bond. Previous studies have reported an X-ray structure of CaaD under acidic conditions with a covalent modification of the catalytic {beta}Pro1 residue. Here, the 1.7 {angstrom} resolution X-ray structure of CaaD under neutral (pH 6.5) conditions is reported without the presence of the covalent adduct. In this new structure, a substrate-like acetate molecule is bound within the active site in a position analogous to the putative substrate-binding site. Additionally, a catalytically important water molecule was identified, consistent with previously proposed reaction schemes. Finally, flexibility of the catalytically relevant side chain {alpha}Glu52 is observed in the structure, supporting its role in the catalytic mechanism.

59 BASIC BIOLOGICAL SCIENCES↗

AN ALMA SURVEY OF SUBMILLIMETER GALAXIES IN THE EXTENDED CHANDRA DEEP FIELD SOUTH: SOURCE CATALOG AND MULTIPLICITY

We present an Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 0 survey of 126 submillimeter sources from the LABOCA ECDFS Submillimeter Survey (LESS). Our 870 {mu}m survey with ALMA (ALESS) has produced maps {approx}3 Multiplication-Sign deeper and with a beam area {approx}200 Multiplication-Sign smaller than the original LESS observations, doubling the current number of interferometrically-observed submillimeter sources. The high resolution of these maps allows us to resolve sources that were previously blended and accurately identify the origin of the submillimeter emission. We discuss the creation of the ALESS submillimeter galaxy (SMG) catalog, including the main sample of 99 SMGs and a supplementary sample of 32 SMGs. We find that at least 35% (possibly up to 50%) of the detected LABOCA sources have been resolved into multiple SMGs, and that the average number of SMGs per LESS source increases with LESS flux density. Using the (now precisely known) SMG positions, we empirically test the theoretical expectation for the uncertainty in the single-dish source positions. We also compare our catalog to the previously predicted radio/mid-infrared counterparts, finding that 45% of the ALESS SMGs were missed by this method. Our {approx}1.''6 resolution allows us to measure a size of {approx}9 kpc Multiplication-Sign 5 kpc for the rest-frame {approx}300 {mu}m emission region in one resolved SMG, implying a star formation rate surface density of 80 M{sub Sun} yr{sup -1} kpc{sup -2}, and we constrain the emission regions in the remaining SMGs to be <10 kpc. As the first statistically reliable survey of SMGs, this will provide the basis for an unbiased multiwavelength study of SMG properties.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗