Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Intrafractional Motion of the Prostate During Hypofractionated Radiotherapy

Purpose: To report the characteristics of prostate motion as tracked by the stereoscopic X-ray images of the implanted fiducials during hypofractionated radiotherapy with CyberKnife. Methods and Materials: Twenty-one patients with prostate cancer who were treated with CyberKnife between January 2005 and September 2007 were selected for this retrospective study. The CyberKnife uses a stereoscopic X-ray system to obtain the position of the prostate target through the monitoring of implanted gold fiducial markers. If there is a significant deviation, the treatment is paused while the patient is repositioned by moving the couch. The deviations calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. Results: Included in the analysis were 427 data sets and 4,439 time stamps of X-ray images. The mean duration for each data set was 697 sec. At 30 sec, a motion >2 mm exists in about 5% of data sets. The percentage is increased to 8%, 11%, and 14% at 60 sec, 90 sec, and 120 sec, respectively. A similar trend exists for other values of prostate motion. Conclusions: With proper monitoring and intervention during treatment, the prostate shifts observed among patients can be kept within the tracking range of the CyberKnife. On average, a sampling rate of {approx}40 sec between consecutive X-rays is acceptable to ensure submillimeter tracking. However, there is significant movement variation among patients, and a higher sampling rate may be necessary in some patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of recycling performance indicators: A study on collection rate in Taiwan

The Taiwan Environmental Protection Administration (Taiwan EPA) launched a national Extended Producer Responsibility (EPR) system after integrating eight private recycling organizations in 1998. After that, the environmental performance of the EPR system brought a lot of attention to policy makers. Many studies show positive environmental effects of the EPR system in Taiwan. However, there are controversial questions remained, such as whether the performance indicators used are the right choice to estimate the environmental effects of the recycling policy? Can those estimated results really reflect the performance of the system? This paper would therefore like to more accurately evaluate the performance indicators of the EPR system based on data observed over the past decade in Taiwan. In the process of evaluating the performance indicators, we have found that the collection rates for durable goods are often ignored in countries that pursue a zero waste policy. This may affect the actual recycling outcome and resource direction targeted by producers. However, in order for the collection rate to be adopted as a policy indicator, how to estimate the amounts of retired or waste products during a period is critical. In this paper, we estimate the collection rate for electrical and electronic waste by using the survival analysis and ownership data analysis approaches. We also provide a comparison of both approaches and put forward suggestions for directions in the future in solid waste management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Moving Toward Consensus on a Photovoltaic Generation Capacity Valuation Methodology

Maintaining adequate generating capacity to meet electricity demand at all times is a fundamental principle for the electric utility industry. This is accomplished through a variety of means including providing/purchasing sufficient generation capacity as well as acquiring the associated ancillary services for the electricity grid. The generation capacity of dispatchable resources is assessed based on technology design parameters. While dispatchable resources have some uncertainty in their output due to unforeseen equipment failures, their dispatch is managed around the demand for electricity and their marginal operating costs. Photovoltaic resources are non-dispatchable because their electrical output is based on both technology design parameters (technology selection, installation characteristics, and site conditions) and a solar resource that varies over a range of time periods (seasonal, daily, hourly, second to second). These solar resource variations, however, are not random and there is an intuitively positive relationship between PV system output and summer peak electricity demand for many locations throughout the U.S. This is because system demand peaks for most utilities are driven by heat-wave cooling demand, and because heat waves are indirectly fed by solar gain, i.e., by the fuel for PV generation. Despite this relationship, there is no consensus across the utility or solar industries on a method for calculating PV capacity or its practical use in electricity markets and utility planning. The U.S. Department of Energy’s Solar America Initiative has provided funding to evaluate the variety of photovoltaic capacity valuation methods and to bring the solar industry, electric utility, and research communities together with the goal of moving toward consensus on what is the most appropriate PV generation capacity valuation methodology using a consensus-oriented process. Developing a framework for accurately and appropriately calculating photovoltaic capacity, and determining the risk of variation, will provide a means for utilities and generators to calculate and innovate around the new economic propositions that an industry recognized PV capacity value calculation method would present.

14 SOLAR ENERGY↗

Long-term stability and mechanical characteristics of kV digital imaging system for proton radiotherapy

Purpose: To quantitatively evaluate the long-term image panel positioning stability and gantry angle dependence for gantry-mounted kV imaging systems. Methods: For patient setup digital imaging systems in isocentric rotating proton beam delivery facilities, physical crosshairs are commonly inserted into the snout to define the kV x-ray beam isocenter. Utilizing an automatic detection algorithm, the authors analyzed the crosshair center positions in 2744 patient setup kV images acquired with the four imagers in two treatment rooms from January 2012 to January 2013. The crosshair position was used as a surrogate for imaging panel position, and its long-term stability at the four cardinal angles and the panel flex dependency on gantry angle was investigated. Results: The standard deviation of the panel position distributions was within 0.32 mm (with the range of variation less than ± 1.4 mm) in both the X-Z plane and Y direction. The mean panel inplane rotations were not more than 0.51° for the four panels at the cardinal angles, with standard deviations ≤0.26°. The panel position variations with gantry rotation due to gravity (flex) were within ±4 mm, and were panel-specific. Conclusions: The authors demonstrated that the kV image panel positions in our proton treatment system were highly reproducible at the cardinal angles over 13 months and also that the panel positions can be correlated to gantry angles. This result indicates that the kV image panel positions are stable over time; the amount of panel sag is predictable during gantry rotation and the physical crosshair for kV imaging may eventually be removed, with the imaging beam isocenter position routinely verified by adequate quality assurance procedures and measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn out to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.

43 PARTICLE ACCELERATORS↗

Integration of a real-time orientation measurement system for a real-time evaluator (RTE) to measure the position and orientation of crane-lifted components

Prefabrication of building components holds the potential to revolutionize the construction industry. Prefabrication consists of manufacturing building components, modules, and other elements in a factory to be shipped and installed on a construction site. Prefabricated components have been produced for various applications including precast concrete panels for new construction and exterior wall retrofits. The manufacturing process has seen much innovation in recent years; however, the installation process has seen minimal advancements. A real-time evaluator (RTE) was developed to reduce the installation cost of prefabricated components by reducing installation time, decreasing rework, and improving accuracy. The RTE uses off-the-shelf hardware and novel algorithms to assist erectors with component installation by measuring the real-time positions of connections and prefabricated components, providing installation guidance through a graphical user interface, and monitoring the accumulated installation errors. An overview of the RTE and the proposed workflow is presented. Previous on-site demonstrations provided valuable feedback from users on the potential areas for improvement of the system. One common request was real-time measurement of component orientation during lifting, a process that previously required that the component remain stationary while the laser tracker cycled through target prisms. This paper will present the incorporation and testing of a real-time orientation measurement system as it was implemented into the RTE, allowing for measurement of component orientation during movement.

Selvakumar, Balaji [ORNL]↗

Discovery and Early Clinical Evaluation of BMS-605339, a Potent and Orally Efficacious Tripeptidic Acylsulfonamide NS3 Protease Inhibitor for the Treatment of Hepatitis C Virus Infection

The discovery of BMS-605339 (35), a tripeptidic inhibitor of the NS3/4A enzyme, is described. This compound incorporates a cyclopropylacylsulfonamide moiety that was designed to improve the potency of carboxylic acid prototypes through the introduction of favorable nonbonding interactions within the S1' site of the protease. The identification of 35 was enabled through the optimization and balance of critical properties including potency and pharmacokinetics (PK). This was achieved through modulation of the P2* subsite of the inhibitor which identified the isoquinoline ring system as a key template for improving PK properties with further optimization achieved through functionalization. A methoxy moiety at the C6 position of this isoquinoline ring system proved to be optimal with respect to potency and PK, thus providing the clinical compound 35 which demonstrated antiviral activity in HCV-infected patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Background Attenuation for Fielded Spectroscopic Detection Systems

Radiation detectors are often placed in positions difficult to shield from the effects of terrestrial background gamma radiation. This is particularly true in the case of Radiation Portal Monitor (RPM) systems, as their wide viewing angle and outdoor installations make them susceptible to radiation from the surrounding area. Reducing this source of background can improve gross-count detection capabilities in the current generation of non-spectroscopic RPM’s as well as source identification capabilities in the next generation of spectroscopic RPM’s. To provide guidance for designing such systems, the problem of shielding a general spectroscopic-capable RPM system from terrestrial gamma radiation is considered. This analysis is carried out by template matching algorithms, to determine and isolate a set of non-threat isotopes typically present in the commerce stream. Various model detector and shielding scenarios are calculated using the Monte-Carlo N Particle (MCNP) computer code. Amounts of nominal-density shielding needed to increase the probability of detection for an ensemble of illicit sources are given. Common shielding solutions such as steel plating are evaluated based on the probability of detection for 3 particular illicit sources of interest, and the benefits are weighed against the incremental cost of shielding. Previous work has provided optimal shielding scenarios for RPMs based on gross-counting measurements, and those same solutions (shielding the internal detector cavity, direct shielding of the ground between the detectors, and the addition of collimators) are examined with respect to their utility to improving spectroscopic detection.

36 MATERIALS SCIENCE↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of low energy ion beam system for space charge compensation experiments

A low energy ion beam system for space charge compensation (SCC) experiments was developed and evaluated. This system was designed for observation of SCC of a positive ion beam with an electron beam. The system consisted of the ion source chamber and the SCC experiment chamber. The ion source chamber was equipped with the compact microwave ion source for low voltage extraction. Ion current at initial position of the analysis chamber was 84 {mu}A at extraction voltage of 500 V, and satisfied a condition to observe the SCC effect clearly. In order to evaluate the SCC, we measured the arrival ion current by supplying thermionic electrons, which were extracted from a tungsten filament driven by ac voltage. As the electron supply, the arrival ion current increased from 40 to 68 {mu}A at the potential of filament of +3 eV which produced the thermionic electron with extremely low energy extracted by space charge of the ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-160: Comparing the Setup Accuracy of Non-Ionizing Patient Localization Systems with CBCT to Reduce Imaging Dose in Prone Breast Treatments

Purpose: CBCT is the current gold standard to verify prone breast patient setup. We investigated in a phantom if non-ionizing localization systems can replace ionizing localization systems for prone breast treatments. Methods: An anthropomorphic phantom was positioned on a prone breast board. Electromagnetic transponders were attached on the left chest surface. The CT images of the phantom were imported to the treatment planning system. The isocenter was set to the center of the transponders. The positions of the isocenter and transponders transferred to the transponder tracking system. The posterior phantom surface was contoured and exported to the optical surface tracking system. A CBCT was taken for the initial setup alignment on the treatment machine. Using the electromagnetic and optical localization systems, the deviation of the phantom setup from the original CT images was measured. This was compared with the difference between the original CT and kV-CBCT images. Results: For the electromagnetic localization system, the phantom position deviated from the original CT in 1.5 mm, 0.0 mm and 0.5 mm in the anterior-posterior (AP), superior-inferior (SI) and left-right (LR) directions. For the optical localization system, the phantom position deviated from the original CT in 2.0 mm, −2.0 mm and 0.1 mm in the AP, SI and LR directions. For the CBCT, the phantom position deviated from the original CT in 4.0 mm, 1.0 mm and −1.0 mm in the AP, SI and LR directions. The measured values from the non-ionizing localization systems differed from those with the CBCT less than 3.0 mm in all directions. Conclusions: This phantom study showed the feasibility of using a combination of non-ionizing localization systems to achieve a similar setup accuracy as CBCT for prone breast patients. This could potentially eliminate imaging dose. As a next step, we are expanding this study to actual patients. This work has been in part supported by Departmental Research Award RODEPT1-JS001, Department of Radiation Oncology, UC Davis Medical Center.

60 APPLIED LIFE SCIENCES↗

Linearized modeling and optimization of shared mooring systems

Shared mooring systems, where adjacent platforms are tethered directly to each other, can reduce anchor quantities and mooring line lengths in a floating array but also introduce new modeling and design challenges. This paper presents and demonstrates a first-order approach to modeling and designing shared mooring systems that simplifies these challenges. We formulate a general, linearized model for the force-displacement response of shared mooring systems, including inter-platform couplings. Using this linearization, we realize significant simplifications to the shared mooring system design problem and propose a corresponding design optimization approach. Finally, we demonstrate the complete approach on a variety of shared-mooring floating wind farm layouts with generic design assumptions and constraints. Some fundamental observations about shared mooring systems can be made from the results. Polygonal array layouts with perpendicular anchor positions appear to maximize shared mooring system efficiency. Also, arrays with greater levels of sharing tend to exhibit larger deviations in offsets between platforms. Overall, the results show how the linearized approach can be applied to efficiently evaluate and systematically optimize preliminary shared mooring system designs.

17 WIND ENERGY↗

Mass separation of a multicomponent plasma flow in a curvilinear magnetic field

The motion of a metal plasma flow of a vacuum-arc discharge in a transportation plasma-optical system with a curvilinear magnetic field is studied experimentally and numerically. The flow position at the output of the system is shown to depend on the cathode material, which determines the mass-to-charge ratio of plasma ions. As a result, the flow with a greater ion mass-to-charge ratio moves along a trajectory with a larger radius. A similar effect is observed in the case of a multicomponent plasma flow generated by a composite cathode. The results of two-fluid MHD simulations of a plasma flow propagating in a curvilinear magnetic field agree qualitatively with the experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Clinical Trials Program at the ESRF Biomedical Beamline ID17: Status and Remaining Steps

For several years the ID17 Biomedical beamline at the ESRF has developed synchrotron radiation therapy preclinical programmes to treat aggressive brain tumours. Two techniques have been developed at the ESRF:a) The Microbeam Radiation Therapy (MRT) using spatially fractionated 'white beam' (energies 50-300 keV) irradiation (beam widths 25-100 {mu}m, spacing between beams 200-400 {mu}m ) with extremely high dose rates (up to about 20 kGy/s) and depositing very high doses (300-1000 Gy) in the targeted tissue.b) The Stereotactic Synchrotron Radiation Therapy (SSRT) using spatially homogeneous monochromatic beam with the energy closely above that of the K-edge of a contrast- or chemotherapeutical agent (iodine, gadolinium, platinum) loaded into the tumour volume for obtaining a dose-enhancement. In 2005 an International review panel of oncology experts has recommended to move to clinical trials on humans in SSRT and on large animals in MRT. The works required for this program were launched in autumn 2007 with constructing a new, dedicated experimental hutch for MRT and a major upgrade of the existing sample-positioning station to a patient-positioning station for SSRT. In parallel, safety systems are developed and progressively implemented and a patient treatment-planning system developed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-758: To Determine the Source Dwell Positions of HDR Brachytherapy Using 2D 729 Ion Chamber Array

Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on the 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly.

60 APPLIED LIFE SCIENCES↗