This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.
This paper considers a bi-level real-time algorithmic framework for networked systems, consisting of several local controllers and a central controller. The central controller issues setpoints to the local controllers to optimize their operational objectives while satisfying system-wide constraints. In this context, the paper develops an online algorithm for tracking the optimal solution of the underlying dynamic optimization problem. The design of the algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements (i.e., feedback). Optimality claims are established in terms of the dynamic regret of the algorithm; the latter is a natural performance criterion in nonstationary environments associated with real-time control problems. Finally, the application of the algorithm to real-time control of power setpoints in an electrical grid is illustrated.
An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).
Critical infrastructures such as the electricity grid can be severely impacted by cyber-attacks on its supply chain. Hence, having a robust cybersecurity infrastructure and management system for the electricity grid is a high priority. This paper proposes a cyber-security protocol for defense against man-in-the-middle (MiTM) attacks to the supply chain, which uses encryption and cryptographic multi-party authentication. A cyber-physical simulator is utilized to simulate the power system, control system, and security layers. The correctness of the attack modeling and the cryptographic security protocol against this MiTM attack is demonstrated in four different attack scenarios.
Phasor measurement units (PMUs) play a crucial role in real-time monitoring and control of power grids. They rely on a communication network to transfer measurement data to the phasor data concentrator (PDC) for further processing and analysis. In this paper, a resilient cross-domain PMU and communication link placement method for minimizing the overall installation cost of the wide-area measurement system (WAMS) is proposed. Here, the main idea is to break down the barrier between the power grid domain and the communication domain, and consider the impact of one when design the other. The PMU placement in the power grid domain takes into account the cost of communication links by generating multiple solutions with equally minimum PMU costs for communication link placement evaluation. On the other hand, the communication link placement problem reduces the cost by customizing the routing policies based on the different roles of PMUs in grid observability. The proposed WAMS design is capable of withstanding any single component failure in the power domain (PMU failure or power branch failure) or in the communication domain (communication link failure or PDC failure). Numerical study on the IEEE 57-bus system reveals that the developed cross-domain optimization framework can significantly reduce the overall installation cost of WAMS while attaining multi-domain resiliency.
Abstract not provided.
Traditionally, centralized approaches have predominantly been used for the power system operation and control. With increasing penetration of small-scale distributed energy resources (DERs) in the distribution network, especially independently owned renewable resources, distributed algorithms can serve as a potential alternative for improving scalability, resiliency and addressing privacy concerns. However, the complexity of distributed algorithms significantly increases with the integration of the legacy devices, the operation of which depend on discrete control variables. This paper aims to provide a review of the distributed optimization algorithms incorporating discrete control variables for the power distribution system. While the research in this domain is still at its nascence, an extensive comparison of the approaches in the literature for applying quadratic penalty, branch and bound,ordinal optimization and proximal operator to handle discrete variables in the framework of ADMM and dual decomposition have been addressed. Future research direction in this field have been also provided.
Inverter-based resources (IBRs) are quickly evolving into a source of reliability services to the electric grid. Penetration levels of variable generation are rapidly increasing, ranging from 60% -70% in some systems. To go further, a fundamental shift is required to address challenges associated with grid stability. Synchronous condensers (SCs) are considered an important complementary technology in such transitions. This paper provides one-of-a-kind insights into real experimental results from operating a real MW-scale system consisting of a 2.2-MVA grid-forming (GFM) and grid-following (GFL) battery energy storage system, 2.5-MVA SCs, and a 3-MVA load bank operating as a small, islanded grid. Challenges that are expected in larger systems were mimicked in this small but real system to demonstrate seamless transitions from one mode to another as well as stable operation with different combinations of GFM and GFM resources, including a "loss of last synchronous generator" case. The experimental results presented in this paper are a valuable resource to everyone involved in developing and validating models or developing controls of power systems consisting of inverters and synchronous condensers.
Abstract- The commissioning and test results of a super ferric, superconducting, quadrupole magnet, constructed by Scientific Magnetics Inc. for Thomas Jefferson National Accelerator Facility (TJNAF also known as JLAB) will be presented. The quadrupole magnet, named Q1, is the first focusing element in the Super High Momentum Spectrometer (SHMS). The SHMS, located within JLAB's experimental Hall C, consists of all superconducting magnets in a dQQQD configuration and is part of the JLAB's 12 Gev upgrade. Here "d" refers to the small horizontal bend dipole, "Q" stands for focusing quadrupole magnets and "D" is the vertical bending, momentum-selecting dipole magnet. Characterization of the magnet's cryogenic heat loads and magnetic field quality will be presented along with descriptions of the magnet's control system, power supply, and quench detection system.
Power consumption and demand continues to grow around the world. As the electric power grid continues to be put under more stress, the conditions of instability are more likely to occur. One cause of such instabilities is intearea oscillations, such as the oscillation that resulted in the August 10, 1996 blackout of the WECC. This paper explores different potential operations of different devices on the power system to improve the damping of these interarea oscillations using two different simulation models
Inclusion of power electronics allows increased controllability and stability in power systems. The simulation of such systems on a large-scale is challenging due to the presence of a large number of switches and nonlinear devices. This paper presents an advanced simulation algorithm to solve the aforementioned problem. The algorithm considers separation of differential algebraic equations (DAEs) on the basis of numerical stiffness and applies hybrid discretization algorithms to simulate the DAEs. The DAEs, in this paper, represent the nonlinear nonautonomous switched system dynamics of power systems. Stability analysis is performed on a general class of nonlinear nonautonomous switched systems to show the constraints under which the proposed algorithm is stable. To show the validity of the proposed algorithm, two case studies are considered: single high-voltage direct current (HVdc) substation based on the modular multilevel converter (MMC); and an example three-terminal MMC-HVdc system. Furthermore, relaxation techniques are introduced to create a stable interface for the separated DAEs. The developed algorithms are also validated with PSCAD/EMTDC-detailed reference models.
Abstract not provided.
A motor-driven, high-current switch is being designed by Stäubli Electrical Connectors in collaboration with Princeton Plasma Physics Laboratory to reverse the DIII-D Toroidal field coil current. The existing field reversing procedure requires approximately 4 h of labor performed between run days to reconfigure the bus work, thus requiring a separate run day to complete experimental scans with both field directions. This typically results in different wall conditions which complicate the results or make them invalid. The proposed switch will complete the reversal process in approximately 4-5 min, between shots, so that wall conditions are not a factor, and easily fits within the 10-12 min DIII-D shot cycle. The switch is a compact design fitting into a 157.5 × 41 cm envelope. The switch uses two copper pins that slide between Stäubli MULTILAM contacts. The switch is rated for total current of 180-kA dc for 10 s with a 12-min repetition rate; the maximum operating coil current is 124-kA dc. The switch diagnostics include: voltage drop, current monitor, thermal monitors, position sensors, and motor torque. Here, the switch is rated for 300 cycles per year, and 3000 cycles overall before contact replacement, with contact inspection yearly. The design details and operation of the switch are covered in this article.
In a regulated business environment a utility must be able to validate that deployed technologies provide quantifiable benefits to the end-use customers. For traditional technologies there are well established procedures for determining what benefits will be derived from the deployment. But for many emerging technologies procedures for determining benefits are less clear and completely absent in some cases. Volt-VAR Optimization is a technology that is being deployed across the nation, but there are still numerous discussions about potential benefits and how they are achieved. This paper will present a method for the evaluation, and quantification of benefits, for field deployments of Volt-VAR Optimization technologies. In addition to the basic methodology, the paper will present a summary of results, and observations, from two separate Volt-VAR Optimization field evaluations using the proposed method.
Explore the source record for details and available documents.
This paper presents a longitudinal study of an Enterprise System (ES) implementation by critically examining the discursive context in which an ES implementation unfolds. The findings show that users strongly supported the ES in the earlier stage of implementation when the technology was an imaginary phenomenon. However, in later stages, when the technology is in use, user support was not consistent. In this phase the ES produces loss of control and an inability to function as an arbiter of fairness (in allocating resources associated with the system) thereby directly challenging existing professional identities and roles. These outcomes, in turn, generate acts of resistance on the part of workers. Users reach inside the technology and reshape it by devising creative workarounds that produce a sense of reskilling to counter the deskilling produced by the loss of control and power. The analysis also shows that an ES is a complex social phenomenon that is intricately linked to and complicit in shaping organizational structure and identity. In particular this study shows how technology, structure, and identity are in a mutually constitutive relationship.
RAVEN has 3 major functionalities: 1. Provides a Graphical User Interface for the pre- and post-processing of the RELAP-7 input and output. 2. Provides the capability to model nuclear power plants control logic for the RELAP-7 code and dynamic control of the accident scenario evolution. This capability is based on a software structure that realizes a direct connection between the RELAP-7 solver engine (MOOSE) and a python environment where the variables describing the plant status are accessible in a scripting environment. RAVEN support the generation of the probabilistic scenario control by supplying a wide range of probability and cumulative distribution functions and their inverse functions. 3. Provides a general environment to perform probability risk analysis for RELAP-7, RELAP-5 and any generic MOOSE based applications. The probabilistic analysis is performed by sampling the input space of the coupled code parameters and it is enhanced by using modern artificial intelligence algorithms that accelerate the identification of the areas of major risk (in the input parameter space). This environment also provides a graphical visualization capability to analyze the outcomes. Among other approaches, the classical Monte Carlo and Latin Hypercube sampling algorithms are available. For the acceleration of the convergence of the sampling methodologies, Support Vector Machines, Bayesian regression, and collocation stochastic polynomials chaos are implemented. The same methodologies here described could be used to solve optimization and uncertainties propagation problems using the RAVEN framework.