Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

National Wind Technology Center-Characterization of Atmospheric Conditions

Data provided by the instrumentation located at the National Wind Technology Center (NWTC) is compiled below for the purposes of characterizing the atmospheric operating conditions at the National Renewable Energy Laboratories (NREL) wind site. Conditions are presented conditioned on month of the year to show seasonal variation, and based on characteristic quantities seen in the atmospheric flow including, bulk wind speed, direction, and atmospheric stability. All data reported and analyzed in the following document were collected from instrumentation mounted on the 135 m-tall masts erected at the NWTC near Boulder, Colorado. Each of the two met-masts (named M4 and M5) were sited specifically to measure the inflow wind to several of the utility-scale turbines at the NWTC. The construction, operation, and maintenance of the masts has been supported since their commissioning in 2011 by the Department of Energy, Office of Energy Efficiency and Renewable Energy, Wind and Water Power Program. Data from the masts are publicly available for download or basic visualization, hosted on NREL's website (https://nwtc.nrel.gov/135mData). Data from the masts have been used in the past for a wide range of projects including wind turbine power performance measurements, high fidelity model development and validation, and atmospheric science research. An interactive visualization platform has been developed on NREL's Open Energy Information platform and can be used to reproduce many of the graphics included in the current work. This report describes in detail the atmospheric conditions recorded by M5, the inflow mast for the DOE-owned GE 1.5 MW wind turbine. The report focuses on data recorded from August 2012 to May 2018 and includes: an introduction to the wind climate at the NWTC; a physical description of the met masts; a review of installed instrumentation; and data collection, processing, and quality control methods. In addition to a concise description of the instrumentation from the met masts and the data channels they provide, this report characterizes the behavior of the atmospheric resource first in a cumulative sense, discussing mainly the distributions wind speeds, flow directions and thermodynamic properties at several heights along the towers. Periodicity in atmospheric conditions is then detailed through analysis of diurnal and annual cycles of the data streams. Periods of both low turbulence and extreme atmospheric events that are of interest in terms of wind turbine operation and wind energy research are detailed in the final chapter of this report. Low turbulence events are somewhat rare at the NWTC and are of interest from the perspective of validating the operation of new wind turbine and blade designs. Similarly, the NTWC is known for a relatively higher rate of occurrence of extreme weather events.

17 WIND ENERGY↗

Wall conditioning and ELM mitigation with boron nitride powder injection in KSTAR

Results from KSTAR powder injection experiments, in which tens of milligrams of boron nitride (BN) were dropped into low-power H-mode plasmas, show an improvement in wall conditions in subsequent discharges and, in some cases, a reduction or elimination of edge-localized modes (ELMs). Injected powder is distributed by the plasma flow and is deposited on the wall and, over the course of several discharges, was observed to gradually reduce recycling by 33%, and decrease both the ELM amplitude and frequency. This is the first demonstration of the use of BN for ELM mitigation. In all of these experiments, an Impurity Powder Dropper (IPD) was used to introduce precise, controllable amounts of the materials into ELMy H-mode KSTAR discharges. The plasma duration was between 10 s and 15 s, I p = 500 kA, B T = 1 . 8 T, P NBI = 1 . 6 MW, and P ECH = 0 . 6 MW. Plasma densities were between 2 and 3 × 1 0 19 m -3 . In all cases, the pre-fill and startup gas-fueling was kept constant, suggesting that the decrease in baseline D α emission is in fact due to a reduction in recycling. The results presented herein highlight the viability of powder injection for intra-shot and between-shot wall conditioning

36 MATERIALS SCIENCE↗

Wall conditioning and ELM mitigation with boron nitride powder injection in KSTAR

Results from KSTAR powder injection experiments, in which tens of milligrams of boron nitride (BN) were dropped into low-power H-mode plasmas, show an improvement in wall conditions in subsequent discharges and, in some cases, a reduction or elimination of edge-localized modes (ELMs). Injected powder is distributed by the plasma flow and is deposited on the wall and, over the course of several discharges, was observed to gradually reduce recycling by 33%, and decrease both the ELM amplitude and frequency. This is the first demonstration of the use of BN for ELM mitigation. In all of these experiments, an Impurity Powder Dropper (IPD) was used to introduce precise, controllable amounts of the materials into ELMy H-mode KSTAR discharges. The plasma duration was between 10 s and 15 s, 𝐼𝑝 = 500 kA, 𝐵𝑇 = 1.8 T, 𝑃NBI = 1.6 MW, and 𝑃ECH = 0.6 MW. Plasma densities were between 2 and 3 × 1019 m−3. In all cases, the pre-fill and startup gas-fueling was kept constant, suggesting that the decrease in baseline D𝛼 emission is in fact due to a reduction in recycling. The results presented herein highlight the viability of powder injection for intra-shot and between-shot wall conditioning.

Gilson, Erik↗

Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Critical Experiments to Provide Validation Data for Multiphysics Coupling Methods (Final Report)

Computational simulation has become one of the most important tools in the modern toolbox for nuclear reactor design. Reactor simulations, like the reactors themselves, involve multiple physical processes including neutronics, fluid flow and heat transfer (thermal-hydraulics), thermo-mechanics, fuel behavior, chemistry, and balance of plant. Each process can affect the behavior of the others, and advanced computational tools have been developed that couple separate physics models together to simulate the feedback effects. The objective of this work is to generate experimental data to support the validation of multi-physics reactor codes. It specifically targets the SHARP toolset from the NEAMS Reactor Product Line, but it is intended to be useful in any set of coded that couples thermal-hydraulics with neutronics simulations. The project takes advantage of the inherent flexibility of the RPI Reactor Critical Facility (RCF), a low power open-pool research reactor. The standard configuration of the RCF is used to explore the effects of moderator temperature on neutronic behavior and reactivity. Because the low power of the reactor generates no appreciable temperature change in the moderator, the moderator temperature is artificially changed with two 18 kW electric immersion heaters. The temperature feedback effects can be observed by recording the change in the reactor power as the reactor goes from a supercritical state, to critical, to a subcritical state. To expand the temperature range and temperature rate of change that can be investigated, an experimental apparatus consisting of a heated water loop was designed and installed in the RCF. In this setup, water from a heated reservoir tank is pumped through a pipe placed through the center of the reactor core. The water in the reservoir can be heated to around 70 °C and pumped through the system. The pump has a variable flow rate and electronic control, so a number of scenarios can be developed. A slug of water can be pushed through the system to generate a reasonably fast change in reactivity. The pump speed can be increased or decreased over the course of a measurement, or even oscillated at different periods, to observe the response of the reactor. To complement the experimental data generated by the RCF, a set of computational models have been developed. They are intended to illustrate the usefulness of the experimental data generated in validating coupled multi-physics simulations. A model previously constructed in MCNP has been used in conjunction with safety analysis at the RCF for many years and was modified to support the design of the heated water loop experiment. This model was translated into Serpent 2, a similar Monte Carlo code, which provided the added advantage of being able to produce collapsed cross-section data files for use in the deterministic neutron transport codes that are part of the SHARP toolset. A complete reconstruction of the RCF model, both with and without the heated fluid loop experiment, were necessary for use with the SHARP codes, PROTEUS (neutronics) and Nek5000 (thermal hydraulics), as these require an unstructured mesh format to operate. The computational requirements for fully coupled three dimensional simulations are significant, and challenges to full implementation and comparison with RCF experiments remain. A wide variety of experiments have been conducted for eventual benchmarking and validation of multi-physics reactor codes. A complete database of detailed time- and temperature-dependent measurements have been generated and stored. Several examples of the experimental results are presented here, with refinement and analysis of experiments ongoing. While these experiments still only address a finite range of operating conditions, in particular being limited to water in the sub-boiling regime, they represent a unique (to date) look at the feedback between temperature and neutronic behavior suited for validation of the coupling routines in multi-physics codes. It is hoped that these will be the foundation of future benchmarks that will provide confidence in the tools that will be used to develop the next generation of nuclear reactor systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solid Oxide Fuel Cell Systems PVL Line

In July 2010, Stark State College (SSC), received Grant DE-EE0003229 from the U.S. Department of Energy (DOE), Golden Field Office, for the development of the electrical and control systems, and mechanical commissioning of a unique 20kW scale high-pressure, high temperature, natural gas fueled Stack Block Test System (SBTS). SSC worked closely with subcontractor, Rolls-Royce Fuel Cell Systems (US) Inc. (RRFCS) over a 13 month period to successfully complete the project activities. This system will be utilized by RRFCS for pre-commercial technology development and training of SSC student interns. In the longer term, when RRFCS is producing commercial products, SSC will utilize the equipment for workforce training. In addition to DOE Hydrogen, Fuel Cells, and Infrastructure Technologies program funding, RRFCS internal funds, funds from the state of Ohio, and funding from the DOE Solid State Energy Conversion Alliance (SECA) program have been utilized to design, develop and commission this equipment. Construction of the SBTS (mechanical components) was performed under a Grant from the State of Ohio through Ohio's Third Frontier program (Grant TECH 08-053). This Ohio program supported development of a system that uses natural gas as a fuel. Funding was provided under the Department of Energy (DOE) Solid-state Energy Conversion Alliance (SECA) program for modifications required to test on coal synthesis gas. The subject DOE program provided funding for the electrical build, control system development and mechanical commissioning. Performance testing, which includes electrical commissioning, was subsequently performed under the DOE SECA program. Rolls-Royce Fuel Cell Systems is developing a megawatt-scale solid oxide fuel cell (SOFC) stationary power generation system. This system, based on RRFCS proprietary technology, is fueled with natural gas, and operates at elevated pressure. A critical success factor for development of the full scale system is the capability to test fuel cell components at a scale and under conditions that can be accurately extrapolated to full system performance. This requires specially designed equipment that replicates the pressure (up to 6.5 bara), temperature (about 910 C), anode and cathode gas compositions, flows and power generation density of the full scale design. The SBTS fuel cell anode gas is produced through the reaction of pipeline natural gas with a mixture of steam, CO2, and O2 in a catalytic partial oxidation (CPOX) reactor. Production of the fuel cell anode gas in this manner provides the capability to test a fuel cell with varying anode gas compositions ranging from traditional reformed natural gas to a coal-syngas surrogate fuel. Stark State College and RRFCS have a history of collaboration. This is based upon SSCAs commitment to provide students with skills for advanced energy industries, and RRFCS need for a workforce that is skilled in high temperature fuel cell development and testing. A key to this approach is the access of students to unique SOFC test and evaluation equipment. This equipment is designed and developed by RRFCS, with the participation of SSC interns. In the near-term, the equipment will be used by RRFCS for technology development. When this stage is completed, and RRFCS has moved to commercial products, SSC will utilize this equipment for workforce training. The RRFCS fuel cell design is based upon a unique ceramic substrate architecture in which a porous, flat substrate (tube) provides the support structure for a network of solid oxide fuel cells that are electrically connected in series. These tubes are grouped into a {approx}350-tube repeat configuration, called a stack/block. Stack/block testing, performed at system conditions, provides data that can be confidently scaled to full scale performance. This is the basis for the specially designed and developed test equipment that is required for advancing and accelerating the RRFCS SOFC power system development program. All contract DE-EE0003229 objectives were achieved and deliverables completed during the period from March 1, 2010 through March 31, 2011. As a result of program completion, the Stack Block Test System was ready to support installation and electrical operation of a RRFCS solid oxide fuel cell (SOFC) stack block in the second quarter of 2011.

01 COAL, LIGNITE, AND PEAT↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

Effects of Combustion-Induced Vortex Breakdown on Flashback Limits of Syngas-Fueled Gas Turbine Combustors

Turbine combustors of advanced power systems have goals to achieve very low pollutants emissions, fuel variability, and fuel flexibility. Future generation gas turbine combustors should tolerate fuel compositions ranging from natural gas to a broad range of syngas without sacrificing operational advantages and low emission characteristics. Additionally, current designs of advanced turbine combustors use various degrees of swirl and lean premixing for stabilizing flames and controlling high temperature NOx formation zones. However, issues of fuel variability and NOx control through premixing also bring a number of concerns, especially combustor flashback and flame blowout. Flashback is a combustion condition at which the flame propagates upstream against the gas stream into the burner tube. Flashback is a critical issue for premixed combustor designs, because it not only causes serious hardware damages but also increases pollutant emissions. In swirl stabilized lean premixed turbine combustors onset of flashback may occur due to (i) boundary layer flame propagation (critical velocity gradient), (ii) turbulent flame propagation in core flow, (iii) combustion instabilities, and (iv) upstream flame propagation induced by combustion induced vortex breakdown (CIVB). Flashback due to first two foregoing mechanisms is a topic of classical interest and has been studied extensively. Generally, analytical theories and experimental determinations of laminar and turbulent burning velocities model these mechanisms with sufficient precision for design usages. However, the swirling flow complicates the flashback processes in premixed combustions and the first two mechanisms inadequately describe the flashback propensity of most practical combustor designs. The presence of hydrogen in syngas significantly increases the potential for flashback. Due to high laminar burning velocity and low lean flammability limit, hydrogen tends to shift the combustor operating conditions towards flashback regime. Even a small amount of hydrogen in a fuel blend triggers the onset of flashback by altering the kinetics and thermophysical characteristics of the mixture. Additionally, the presence of hydrogen in the fuel mixture modifies the response of the flame to the global effects of stretch and preferential diffusion. Despite its immense importance in fuel flexible combustor design, little is known about the magnitude of fuel effects on CIVB induced flashback mechanism. Hence, this project investigates the effects of syngas compositions on flashback resulting from combustion induced vortex breakdown. The project uses controlled experiments and parametric modeling to understand the velocity field and flame interaction leading to CIVB driven flashback.

03 NATURAL GAS↗

A Frozen Soil Barrier to Control Groundwater Inflow into Damaged Reactors at the Fukushima Daiichi Nuclear Power Station - 16613

Reactor buildings and support facilities at the Fukushima Daiichi Nuclear Power Station (F1 Site) were damaged by a March 2011 tsunami. In response, the Tokyo Electric Power Company (TEPCO) is implementing a number of countermeasures to limit the releases and impacts of contaminated water to the surrounding environment. The diverse countermeasures work together in an integrated manner to provide different types, and several levels, of environmental protection. In general, the strategy represents an example of a 'defense in depth' concept that is used for nuclear facilities around the world. One of the key countermeasures is a frozen soil barrier encircling the damaged reactor facilities. The frozen barrier is intended to limit the flow of water into the area, reduce the amount of water entering damaged reactors, and reduce the resulting volume of contaminated water that requires treatment and storage. The frozen soil barrier was designed and installed by a team from TEPCO and Kajima Corporation. A group of scientists and engineers from US Department of Energy National Laboratories provided independent evaluation of the frozen barrier design and operational plans along with technical recommendations to the TEPCO team. The frozen soil barrier design extends to about 30 m depth; the bottom of the barrier is in a low permeability interval, and the total barrier length around the reactors is just over 1.5 km. The barrier required 1927 total boreholes: 1568 for freeze pipes plus 359 for temperature monitoring arrays. Drilling of all of the boreholes was completed November 9, 2015. Construction of the refrigeration plant is complete and all of the above ground piping/manifolds are in the final stages of construction. The DOE laboratory independent assessment of the frozen soil barrier concluded that the technical characteristics of a frozen barrier are relatively well suited to Fukushima-specific hydrogeologic conditions and the need for reducing the inflow of water into damaged reactors at the F1 Site. The scale of the Fukushima barrier is bounded by industry experience and the equipment and infrastructure proposed for the ground freezing is well understood. The on-site pilot test at Fukushima indicated predictable ground freezing and supported the full scale design parameters. These factors increase the confidence in the frozen soil barrier project underway at Fukushima. TEPCO is currently working with the Japanese Nuclear Regulatory Authority (NRA), providing operational plans/strategies for the frozen soil barrier and modeling results of the projected performance. Full scale frozen soil barrier operations are to begin after authorization from NRA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filamentary surface plasma discharge flow length and time scales

Nanosecond surface dielectric barrier discharges (ns-SDBDs) are a class of plasma actuators that utilize a high-voltage pulse of nanosecond duration between two surface-mounted electrodes to create an electrical breakdown of air, along with rapid heating. These actuators usually produce multiple filaments when operated at high pulse frequencies, and the rapid heating leads to the formation of shock waves and complex flow fields. In this work we replicate a single filament of the ns-SDBDs and characterize the induced flow using velocity measurements from particle image velocimetry and density measurements from background-oriented schlieren. The discharge is produced by a high voltage electrical pulse between two copper electrodes on an acrylic base. A hot gas kernel characterizes the flow field formed close to the electrodes that expands and cools over time and a vortex ring that propagates away from the surface while entraining cold ambient fluid. The gas density deficit inside the kernel displays a power-law decay over time. Based on the observations, we develop a simplified theoretical model based on vortex-driven cooling and perform a scaling analysis to obtain the induced flow length and time scales. The results show that the cooling process's time scales correspond to a circulation-based time scale of the vortex ring, and the length scale of the kernel corresponds to the vortex ring radius. Furthermore, these findings can guide the choice of optimal filament spacing and pulse frequencies in the design, deployment, and operation of ns-SDBDs for flow control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kosterlitz-Thouless scaling at many-body localization phase transitions

We propose a scaling theory for the many-body localization (MBL) phase transition in one dimension, building on the idea that it proceeds via a ‘quantum avalanche’. We argue that the critical properties can be captured at a coarse-grained level by a Kosterlitz-Thouless (KT) renormalization group (RG) flow. On phenomenological grounds, we identify the scaling variables as the density of thermal regions and the lengthscale that controls the decay of typical matrix elements. Within this KT picture, the MBL phase is a line of fixed points that terminates at the delocalization transition. We discuss two possible scenarios distinguished by the distribution of rare, fractal thermal inclusions within the MBL phase. In the first scenario, these regions have a stretched exponential distribution in the MBL phase. In the second scenario, the near-critical MBL phase hosts rare thermal regions that are power-law distributed in size. This points to the existence of a second transition within the MBL phase, at which these power-laws change to the stretched exponential form expected at strong disorder. In conclusion, we numerically simulate two different phenomenological RGs previously proposed to describe the MBL transition. Both RGs display a universal power-law length distribution of thermal regions at the transition with a critical exponent α c = 2, and continuously varying exponents in the MBL phase consistent with the KT picture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Revisiting Theoretical Limits for One-Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one-degree-of-freedom wave energy converters. This paper considers the floating sphere used in the Ocean Energy Systems Task 10 Wave Energy Converter modeling and verification effort for analysis. Analytical equations are derived to determine bounds on the motion amplitude, time-averaged power, and power-take-off (PTO) force. A unique result was found that shows the time-averaged power absorbed by a wave energy converter can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force amplitude was derived that has provided upper and lower bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression can only provide a lower bound, as there is theoretically no upper bound. These bounds are used to compare the performance of a floating sphere if it were to extract energy using surge or heave motion. The analysis shows that because of the differences in hydrodynamic coefficients of each oscillating mode, there will be different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on power absorption while also utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate the time-averaged power with a nonideal PTO is modified by the mechanical-to-electrical efficiency and the ratio of the PTO spring and damping coefficients. The PTO spring and damping coefficients were separated in the expression, which allows for limits to be set on the possible values of PTO coefficients to ensure a net flow of power to the grid.

50 EE - Wind and Water Power Program - Water (EE-4↗

Revisiting Theoretical Limits for One-Degree-of-Freedom Wave Energy Converters: Preprint

This work revisits the theoretical limits of one-degree of freedom wave energy converters (WECs). This paper considers the floating sphere used in the Ocean Energy Systems (OES) Task 10 Wave Energy Converter modeling and verification effort for analysis. Analytical equations are derived to determine bounds on the motion amplitude, time-averaged power, and power take-off (PTO) force. A unique result was found that shows the time-averaged power absorbed by a WEC can be defined solely by the inertial properties and the radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force amplitude was derived which has provided upper and lower bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression can only provide a lower bound as there is theoretically no upper bound. These bounds are used to compare the performance of a floating sphere if it were to extract energy using surge or heave motion. The analysis shows that because of the differences in hydrodynamic coefficients of each oscillating mode there will be different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on power absorption while also utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate the time-averaged power with a nonideal PTO is modified by the mechanical-to-electrical efficiency and the ratio of the PTO spring and damping coefficients. These were separated in the expression which allows for limits to be set on the possible values of PTO coefficients to ensure a net flow of power to the grid.

50 EE - Wind and Water Power Program - Water (EE-4↗

Thermal Transients in District Heating Systems

Heat fluxes in a district heating pipeline systems need to be controlled on the scale from minutes to an hour to adjust to evolving demand. There are two principal ways to control the heat flux - keep temperature fixed but adjust velocity of the carrier (typically water) or keep the velocity flow steady but then adjust temperature at the heat producing source (heat plant). Here, we study the latter scenario, commonly used for operations in Russia and Nordic countries, and analyze dynamics of the heat front as it propagates through the system. Steady velocity flows in the district heating pipelines are typically turbulent and incompressible. Changes in the heat, on either consumption or production sides, lead to slow transients which last from tens of minutes to hours. We classify relevant physical phenomena in a single pipe, e.g. turbulent spread of the turbulent front. We then explain how to describe dynamics of temperature and heat flux evolution over a network efficiently and illustrate the network solution on a simple example involving one producer and one consumer of heat connected by “hot” and “cold” pipes. We conclude the manuscript motivating future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designer membraneless organelles sequester native factors for control of cell behavior

Subcellular compartmentalization of macromolecules increases flux and prevents inhibitory interactions to control biochemical reactions. Inspired by this functionality, we sought to build designer compartments that function as hubs to regulate the flow of information through cellular control systems. Here we report a synthetic membraneless organelle platform to control endogenous cellular activities through sequestration and insulation of native proteins. We engineer and express a disordered protein scaffold to assemble micron size condensates and recruit endogenous clients via genomic tagging with high-affinity dimerization motifs. By relocalizing up to ninety percent of a targeted enzymes to synthetic condensates, we efficiently control cellular behaviors, including proliferation, division, and cytoskeletal organization. Further, we demonstrate multiple strategies for controlled cargo release from condensates to switch cells between functional states. These synthetic organelles offer a powerful and generalizable approach to modularly control cell decision-making in a variety of model systems with broad applications for cellular engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Conductivity SiC/SiC Ceramic Composites for Fusion Blanket Flow Channel Inserts

Dual-coolant blanket designs for fusion reactors currently under development benefit from flow channel inserts that possess low electrical conductivity and low thermal conductivity. Such flow channel inserts will advance the state of fusion technology closer to producing continuous low cost, non-polluting power as is planned under DEMO. In addition to low electrical and thermal conductivity, the desired properties of the flow channel insert are compatibility with lead-lithium breeder/coolant, stability under a high neutron fluence, and mechanical robustness. Silicon carbide fiber-reinforced silicon carbide matrix composites (SiC/SiC) have been shown to meet all of these requirements with the exception of the thermal conductivity requirement. Efforts to manipulate the thermal conductivity included compositional and architectural approaches. An architecturally engineered SiC/SiC was demonstrated that met the low through-thickness thermal conductivity. An understanding of the factors controlling the through-thickness electrical conductivity was also developed and now allows engineering control of the electrical conductivity within the composite. Refinements in the design of a SiC/SiC composite flow channel insert were performed as well as identifying critical mechanical properties. Testing in molten Pb-Li was performed in a building-block manner starting with coupons and culminating in the testing of SiC/SiC flow channel insert segments at ~500ºC under 10 psig. Sections of both a simpler monocoque SiC/SiC flow channel insert and a nested flow channel insert were evaluated for compatibility and impermeability in the Pb-Li and included in situ measurements of electrical and thermal conductivity.

36 MATERIALS SCIENCE↗

NFD Methodology Report

The NetFlow Dynamics (NFD) model was developed for estimating the availability of a commodity supplied by a national- or regional-scale infrastructure following unexpected disruption of one or more of its components. The large scope of the disruptions of interest produce changes in availability lasting days to weeks. Consequently, the model does not resolve daily variations in system state and does not include the long-term processes that cause infrastructures to evolve as assets are added and removed according to owners ’planning decisions. NFD simulates fluid flow, including petroleum and other incompressible fluids, as well as natural gas and other compressible fluids, through pipeline networks characterized by limits on transmission capacity and storage. It was designed to enable efficient exploration of possible transmission system responses to large-scale disruptions lasting for days or longer. The model formulation reflects constraints on transmission and storage capacity imposed by the physical system assets. Those capacity limits are input parameters and are not derived from more basic system properties such as pipeline diameters and compressor power. A system’s response to a large disruption is controlled by operational decisions as well as damage to physical assets. The NFD model formulation allows users to efficiently consider alternative scenarios about the way remaining capacity might be used so that the analysis result appropriately reflects uncertainties about operator response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗