Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

NuSTAR observations of the magnetar 1E 2259+586

We report on new broad band spectral and temporal observations of the magnetar 1E 2259+586, which is located in the supernova remnant CTB 109. Our data were obtained simultaneously with the Nuclear Spectroscopic Telescope Array (NuSTAR) and Swift, and cover the energy range from 0.5-79 keV. We present pulse profiles in various energy bands and compare them to previous RXTE results. The NuSTAR data show pulsations above 20 keV for the first time and we report evidence that one of the pulses in the double-peaked pulse profile shifts position with energy. The pulsed fraction of the magnetar is shown to increase strongly with energy. Our spectral analysis reveals that the soft X-ray spectrum is well characterized by an absorbed double blackbody or blackbody plus power-law model in agreement with previous reports. Our new hard X-ray data, however, suggest that an additional component, such as a power law, is needed to describe the NuSTAR and Swift spectrum. We also fit the data with the recently developed coronal outflow model by Beloborodov for hard X-ray emission from magnetars. The outflow from a ring on the magnetar surface is statistically preferred over outflow from a polar cap.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

The literature on stopping powers and ranges for proton and heavier ions is vast. It includes measurements, theory, evaluations and tabulations, and software programs and routines. Electronic stopping powers are typically calculated with either the Bethe-Bloch Equation or empirically derived functions, depending on the energy regime of the ion. Nuclear stopping powers are typically calculated using a theoretical approach. Ranges are commonly calculated numerically using path length integration, stopping power data and the continuous slowing down approximation. The Stopping and Ranges of Ions in Matter (SRIM) by Ziegler et al., which provides these and other capabilities, exemplifies the integration of highly-realistic theories, evaluated data, and radiation transport capabilities. In applications where speed and simplicity are paramount considerations, analytical calculations of range offer considerable advantages over numerical methods. Range has long been calculated analytically using a simple power law known as the range-energy relationship. This provides excellent accuracy over a surprisingly wide interval of ion species (e.g. protons, carbon), ion energies (e.g. 10-200 MeV/u), absorber compositions (e.g. plastic, water, metal), and thickness (e.g. 0.5-1 10 mm). The major limitation of formulas derived from a simple power law relation was their limited interval of applicability, 1.e., 10-200 MeV for protons in water. Thus, fora projectile in a stopping length target, such as a cancer patient, the simple power law model breaks down in the biologically important interval below 10 MeV. In current standard-of-care treatment planning, this is typically not a concern because the resulting range errors are less than 1 mm (and can be accounted for) and because biological effects are not calculated based on ion stopping power. However, there is considerable interest to perform multi-scale calculations of ion beams, e.g., at dimensions corresponding to cellular DNA, with ion energies below 10 MeV. Thus, there is an increasing need for new fast and simple formulae to calculate range and stopping power across a broader energy intervals of ion energy. It was not known if simple analytical equations would meet this need and, if so, the limits of their applicability. The aim of this work was to develop a simple, non-piecewise continuous model of total stopping power which could be analytically integrated to provide a simple formula for range. More specifically, we sought to develop a model to provide stopping powers with accuracy of better than 20% and range errors less than 1 mm for hydrogen, carbon, iron, and uranium projectile ions and target materials including water, carbon, aluminum, lead, copper, iron, gadolinium, and gold. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Power system resilience through defender-attacker-defender models with uncertainty: an overview

Protecting and fortifying a power system to make it resilient is an important and hard problem to solve. The interaction between defenders and attackers, the availability of information and the complexity of power system require carefully selecting models and presenting the underlying assumptions. Trilevel defender-attacker-defender models have been developed to investigate the resilience of power systems. In this paper, we review trilevel models in power system application, with the aim of demonstrating the accessibility and applicability of these complex optimization formulations and discussing the underlying assumptions from these models. In particular, we highlight modeling choices, algorithmic details, and how operational and information uncertainty affects resilience versus the traditional complete-knowledge-based optimal solutions. We also describe other similar relevant models which lack such uncertainty and discuss insights on how to address operational, attacker, and defender related uncertainties in future research efforts.

multi-level optimization, defender-attacker-defend↗

Modeling the full-bridge series-resonant power converter

A steady state model is derived for the full-bridge series-resonant power converter. Normalized parametric curves for various currents and voltages are then plotted versus the triggering angle of the switching devices. The calculations are compared with experimental measurements made on a 50 kHz converter and a discussion of certain operating problems is presented.

King, R. J.↗

Computing the Power-Density Spectrum for an Engineering Model

Computer program for calculating of power-density spectrum (PDS) from data base generated by Advanced Continuous Simulation Language (ACSL) uses algorithm that employs fast Fourier transform (FFT) to calculate PDS of variable. Accomplished by first estimating autocovariance function of variable and then taking FFT of smoothed autocovariance function to obtain PDS. Fast-Fourier-transform technique conserves computer resources.

Dunn, H. J.↗

From scale properties of physical amplitudes to a predictive formulation of the Nambu-Jona-Lasinio model

The predictive power of the Nambu-Jona-Lasinio model is considered in the light of a novel strategy to handle the divergences typical of perturbative calculations. The referred calculational strategy eliminates unphysical dependencies on the arbitrary choices for the routing of internal momenta and symmetry violating terms. In the present work we extend a previous one on the same issue by including vector interactions and performing the discussion in a more general context: the role of scale arbitrariness for the consistency of the calculations is considered. We show that the imposition of arbitrary scale independence for the consistent regularized amplitudes lead to additional properties for the irreducible divergent objects. These properties allow us to parametrize the remaining freedom in terms of a unique constant where resides all the arbitrariness involved. By searching for the best value for the arbitrary parameter we find a critical condition for the existence of an acceptable physical value for the dynamically generated quark mass. Such critical condition fixes the remaining arbitrariness turning the Nambu-Jona-Lasinio into a predictive model in the sense that its phenomenological consequences do not depend on possible choices made in intermediary steps. Numerical results are obtained for physical quantities like the vector and axial-vector masses and their coupling constants as genuine predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Expectation-Maximization Method for Calibrating Synchronous Machine Models

The accuracy of a power system dynamic model is essential to its secure and efficient operation. Lower confidence in model accuracy usually leads to conservative operation and lowers asset usage. To improve model accuracy, this paper proposes an expectation-maximization (EM) method to calibrate the synchronous machine model using phasor measurement unit (PMU) data. First, an extended Kalman filter (EKF) is applied to estimate the dynamic states using measurement data. Then, the parameters are calculated based on the estimated states using maximum likelihood estimation (MLE) method. The EM method iterates over the preceding two steps to improve estimation accuracy. The proposed EM method’s performance is evaluated using a single-machine infinite bus system and compared with a method where both state and parameters are estimated using an EKF method. Sensitivity studies of the parameter calibration using EM method are also presented to show the robustness of the proposed method for different levels of measurement noise and initial parameter uncertainty.

EM Algorithms↗

1.2.2.404 – Improving the Representation of Hydropower in Production Cost Models

This project's goal is to improve hydropower's representation in power system models by actively coupling river basin (hydrologic) models with grid operations (production cost) models. Near term, this work provides a foundation that allows improved available flexibility and operational constraints representation. Longer term, the work will provide a template that can be used by commercial production cost modeling software vendors to capture the nuances of hydropower operations in their software offerings.

HYDRO ENERGY↗

Realization of power law inflation & variants via variation of the strong coupling constant

We present a model of power law inflation generated by variation of the strong coupling constant. We then extend the model to two varying coupling constants which leads to a potential consisting of a linear combination of exponential terms. Some variants of the latter may be self-consistent and can accommodate the experimental data of the Planck 2015 and other recent experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-Ray Spectra of Young Pulsars and Their Wind Nebulae: Dependence on Spin-Down Energy Loss Rate

An observational model is presented for the spectra of young rotation-powered pulsars and their nebulae based on a study of nine bright Crab-like pulsar systems observed with the Chandra X-ray observatory. A significant correlation is discovered between the X-ray spectra of these pulsars and that of their associated pulsar wind nebulae, both of which are observed to be a function of the spin-down energy loss rate, E. The 2-10 keV spectra of these objects are well characterized by an absorbed power-law model with photon indices, Gamma, in the range of 0.6 < Gamma (sub PSR) < 2.1 and 1.3 < Gamma(sub PWN) < 2.3, for the pulsars and their nebulae, respectively. A linear regression fit relating these two sets of indexes yields Gamma(sub PWN) = 0.91 +/- 0.18 + (0.66 +/- 0.11) Gamma (sub PSR), with a correlation coefficient of r = 0.97. The spectra of these pulsars are found to steepen as Gamma = Gamma(sub max) + alpha E (exp -1/2), with Gamma(sub max) providing an observational limit on the spectral slopes of young rotation-powered pulsars. These results reveal basic properties of young pulsar systems, allow new observational constraints on models of pulsar wind emission, and provide a means of predicting the energetics of pulsars lacking detected pulsations.

Gotthelf, E. V.↗

Integrated Process Model Development and Systems Analyses for the LIFE Power Plant

We have developed an integrated process model (IPM) for a Laser Inertial Fusion-Fission Energy (LIFE) power plant. The model includes cost and performance algorithms for the major subsystems of the plant, including the laser, fusion target fabrication and injection, fusion-fission chamber (including the tritium and fission fuel blankets), heat transfer and power conversion systems, and other balance of plant systems. The model has been developed in Visual Basic with an Excel spreadsheet user interface in order to allow experts in various aspects of the design to easily integrate their individual modules and provide a convenient, widely accessible platform for conducting the system studies. Subsystem modules vary in level of complexity; some are based on top-down scaling from fission power plant costs (for example, electric plant equipment), while others are bottom-up models based on conceptual designs being developed by LLNL (for example, the fusion-fission chamber and laser systems). The IPM is being used to evaluate design trade-offs, do design optimization, and conduct sensitivity analyses to identify high-leverage areas for R&D. We describe key aspects of the IPM and report on the results of our systems analyses. Designs are compared and evaluated as a function of key design variables such as fusion target yield and pulse repetition rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Optimization-Based Model Reduction Scheme for Renewable Energy Power Plants Using Standardized Testing Scenarios

This paper presents an optimization-based model reduction scheme for renewable energy (RE) power plants consisting of inverter-based resources (IBRs) operating in grid-following (GFL) or grid-forming (GFM) modes. More importantly, the datasets feeding the optimization-based model reduction scheme are generated and re-used through the standardized grid-interactive testing scenarios. Particularly, the proposed scheme makes use of the power plant point of common coupling (PCC) measurements of various quantities specified by standardized tests (e.g., voltage and frequency ride through) as per IEEE 2800, to estimate the parameters of the reduced-order model such that its dynamic performance aligns with the original detailed power plant model. The proposed model reduction approach does not require the parameters of individual IBRs and using standardized test data as input to the formulated optimization problem simplifies the reduced-order modelling scheme. Extensive case studies following standardized test scenarios verified the remarkable accuracy of the proposed approach.

Yallamilli, Ram S. [Purdue University]↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate-Induced Tradeoffs in Planning and Operating Costs of a Regional Electricity System

Electricity grid planners design the system in order to supply electricity to end users reliably and affordably. Climate change threatens both objectives through potentially compounding supply- and demand-side climate-induced impacts. Uncertainty surrounds each of these future potential impacts. Given long planning horizons, system planners must weigh investment costs against operational costs under this uncertainty. Here, we developed a comprehensive and coherent integrated modeling framework combining physically-based models with cost-minimizing optimization models in the power system. We applied this modeling framework to analyze potential tradeoffs in planning and operating costs in the power grid due to climate change in the Southeast U.S. in 2050. We find that planning decisions that do not account for climate-induced impacts would result in a substantial increase in social costs associated with loss of load. These social costs are a result of under-investment in new capacity and capacity deratings of thermal generators when we included climate change impacts in the operation stage. Finally, these results highlight the importance of including climate change effects in the planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Verification of a 2 kWe Closed-Brayton-Cycle Power Conversion System Mechanical Dynamics Model

Vibration test data from an operating 2 kWe closed-Brayton-cycle (CBC) power conversion system (PCS) located at the NASA Glenn Research Center was used for a comparison with a dynamic disturbance model of the same unit. This effort was performed to show that a dynamic disturbance model of a CBC PCS can be developed that can accurately predict the torque and vibration disturbance fields of such class of rotating machinery. The ability to accurately predict these disturbance fields is required before such hardware can be confidently integrated onto a spacecraft mission. Accurate predictions of CBC disturbance fields will be used for spacecraft control/structure interaction analyses and for understanding the vibration disturbances affecting the scientific instrumentation onboard. This paper discusses how test cell data measurements for the 2 kWe CBC PCS were obtained, the development of a dynamic disturbance model used to predict the transient torque and steady state vibration fields of the same unit, and a comparison of the two sets of data.

Ludwiczak, Damian R.↗

8760-Based Method for Representing Variable Generation Capacity Value in Capacity Expansion Models

Capacity expansion models (CEMs) are widely used to evaluate the least-cost portfolio of electricity generators, transmission, and storage needed to reliably serve load over many years or decades. CEMs can be computationally complex and are often forced to estimate key parameters using simplified methods to achieve acceptable solve times or for other reasons. In this paper, we discuss one of these parameters -- capacity value (CV). We first provide a high-level motivation for and overview of CV. We next describe existing modeling simplifications and an alternate approach for estimating CV that utilizes hourly '8760' data of load and VG resources. We then apply this 8760 method to an established CEM, the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) model (Eurek et al. 2016). While this alternative approach for CV is not itself novel, it contributes to the broader CEM community by (1) demonstrating how a simplified 8760 hourly method, which can be easily implemented in other power sector models when data is available, more accurately captures CV trends than a statistical method within the ReEDS CEM, and (2) providing a flexible modeling framework from which other 8760-based system elements (e.g., demand response, storage, and transmission) can be added to further capture important dynamic interactions, such as curtailment.

14 SOLAR ENERGY↗